The DOI matches its Crossref record.
Global Analysis of Fluorescence Lifetime Imaging Microscopy Data
Open accessAbstract
Global analysis techniques are described for frequency domain fluorescence lifetime imaging microscopy (FLIM) data. These algorithms exploit the prior knowledge that only a limited number of fluorescent molecule species whose lifetimes do not vary spatially are present in the sample. Two approaches to implementing the lifetime invariance constraint are described. In the lifetime invariant fit method, each image in the lifetime image sequence is spatially averaged to obtain an improved signal-to-noise ratio. The lifetime estimations from these averaged data are used to recover the fractional contribution to the steady-state fluorescence on a pixel-by-pixel basis for each species. The second, superior, approach uses a global analysis technique that simultaneously fits the fractional contributions in all pixels and the spatially invariant lifetimes. In frequency domain FLIM the maximum number of lifetimes that can be fit with the global analysis method is twice the number of lifetimes that can be fit with conventional approaches. As a result, it is possible to discern two lifetimes with a single-frequency FLIM setup. The algorithms were tested on simulated data and then applied to separate the cellular distributions of coexpressed green fluorescent proteins in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imaging biochemistry inside cells
Wouters, F. S., Verveer, P. J., & Bastiaens, P. I. H. (2001) · Trends in Cell Biology · doi:10.1016/s0962-8924(01)01982-1 · Cited by 395
Self-citationQuantitative Imaging of Lateral ErbB1 Receptor Signal Propagation in the Plasma Membrane
Verveer, P. J., Wouters, F. S., Reynolds, A. R., & Bastiaens, P. I. H. (2000) · Science · doi:10.1126/science.290.5496.1567 · Cited by 351
Self-citationFereidouni, F., Bader, A. N., & Gerritsen, H. C. (2012) · Optics Express · doi:10.1364/oe.20.012729 · Cited by 257
Fluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
Sparks, H., Kondo, H., Hooper, S., Munro, I., Kennedy, G., Dunsby, C., French, P., & Sahai, E. (2018) · Nature Communications · doi:10.1038/s41467-018-04820-6 · Cited by 54
Metadata
- Authors
- Verveer, P. J., Squire, A., & Bastiaens, P. I. H.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2000-04
- Volume
- 78
- Issue
- 4
- Pages
- 2127-2137
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1980759701
- Cited by
- 221
- References
- 0
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Global Analysis of Fluorescence Lifetime Imaging Microscopy Data. https://app.cochat.ai/papers/10.1016/s0006-3495(00)76759-2
- The paper
- Verveer, P. J., Squire, A., & Bastiaens, P. I. H. (2000). Global Analysis of Fluorescence Lifetime Imaging Microscopy Data. Biophysical Journal. https://doi.org/10.1016/s0006-3495(00)76759-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.