Global Analysis of Fluorescence Lifetime Imaging Microscopy Data
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Global analysis techniques are described for frequency domain fluorescence lifetime imaging microscopy (FLIM) data. These algorithms exploit the prior knowledge that only a limited number of fluorescent molecule species whose lifetimes do not vary spatially are present in the sample. Two approaches to implementing the lifetime invariance constraint are described. In the lifetime invariant fit method, each image in the lifetime image sequence is spatially averaged to obtain an improved signal-to-noise ratio. The lifetime estimations from these averaged data are used to recover the fractional contribution to the steady-state fluorescence on a pixel-by-pixel basis for each species. The second, superior, approach uses a global analysis technique that simultaneously fits the fractional contributions in all pixels and the spatially invariant lifetimes. In frequency domain FLIM the maximum number of lifetimes that can be fit with the global analysis method is twice the number of lifetimes that can be fit with conventional approaches. As a result, it is possible to discern two lifetimes with a single-frequency FLIM setup. The algorithms were tested on simulated data and then applied to separate the cellular distributions of coexpressed green fluorescent proteins in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Handbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
The Differentiation of Pseudo-Inverses and Nonlinear Least Squares Problems Whose Variables Separate
Golub, G. H., & Pereyra, V. (1973) · SIAM Journal on Numerical Analysis · doi:10.1137/0710036 · Cited by 1,430
Fluorescence lifetime imaging of free and protein-bound NADH.
Lakowicz, J. R., Szmacinski, H., Nowaczyk, K., & Johnson, M. L. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.4.1271 · Cited by 766 · cited 1×
“…resonance energy transfer (FRET) or collisional quenching, properties that have been exploited for resolving physiological parameters in the cell (Lakowicz et al., 1992, 1994; Gadella et al., 1993, 1999; Gadella and Jovin, 1995; Sanders et al., 1995; Szmancinski and Lakowicz, 1995; Bastiaens and…”
BackgroundGOLUBf, G. H., & Pereyra, V. L. (1973) · Cited by 732
Fluorescence lifetime imaging microscopy: spatial resolution of biochemical processes in the cell
Bastiaens, P. (1999) · Trends in Cell Biology · doi:10.1016/s0962-8924(98)01410-x · Cited by 716 · cited 1×
“The fluorescence lifetime is sensitive to environmental conditions such as pH, and excited state reactions such as fluorescence resonance energy transfer (FRET) or collisional quenching, properties that have been exploited for resolving physiological parameters in the cell (Lakowicz et al., 1992, 1994; Gadella et al.,…”
BackgroundSelf-citationSimultaneous analysis of multiple fluorescence decay curves: A global approach
Knutson, J. R., Beechem, J. M., & Brand, L. (1983) · Chemical Physics Letters · doi:10.1016/0009-2614(83)87454-5 · Cited by 571 · cited 3×
“In this paper these problems are solved by applying a global analysis method to frequency domain FLIM image sequences in a fashion similar to techniques used for the analysis of fluorescence measurements in cuvettes (Knutson et al., 1983; Beechem et al., 1983, 1985; Beechem and Brand, 1986; Beechem, 1992; Gratton et a…”
MethodAnalysis of fluorescence decay kinetics from variable-frequency phase shift and modulation data
Lakowicz, J. R., Laczkó, G., Cherek, H., Gratton, E., & Limkeman, M. (1984) · Biophysical Journal · doi:10.1016/s0006-3495(84)84043-6 · Cited by 466 · cited 8×
“However, fitting more than two components is a far more complex problem than fitting a two-component model (Gratton et al., 1984; Lakowicz et al., 1984).”
BackgroundMethodInfluentialGadella, T. W., & Jovin, T. M. (1995) · The Journal of cell biology · doi:10.1083/jcb.129.6.1543 · Cited by 438
Cited by
The Phasor Approach to Fluorescence Lifetime Imaging Analysis
Digman, M. A., Caiolfa, V. R., Zamai, M., & Gratton, E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120154 · Cited by 1,145
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Spectral imaging and its applications in live cell microscopy
Zimmermann, T., Rietdorf, J., & Pepperkok, R. (2003) · FEBS Letters · doi:10.1016/s0014-5793(03)00521-0 · Cited by 536
Xia, Z., & Liu, Y. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75886-9 · Cited by 518
Stringari, C., Cinquin, A., Cinquin, O., Digman, M. A., Donovan, P. J., & Gratton, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108161108 · Cited by 427
Imaging biochemistry inside cells
Wouters, F. S., Verveer, P. J., & Bastiaens, P. I. H. (2001) · Trends in Cell Biology · doi:10.1016/s0962-8924(01)01982-1 · Cited by 395
Self-citationQuantitative Imaging of Lateral ErbB1 Receptor Signal Propagation in the Plasma Membrane
Verveer, P. J., Wouters, F. S., Reynolds, A. R., & Bastiaens, P. I. H. (2000) · Science · doi:10.1126/science.290.5496.1567 · Cited by 351
Self-citationFit-free analysis of fluorescence lifetime imaging data using the phasor approach
Ranjit, S., Malacrida, L., Jameson, D. M., & Gratton, E. (2018) · Nature Protocols · doi:10.1038/s41596-018-0026-5 · Cited by 326
Ng, T. (2001) · The EMBO Journal · doi:10.1093/emboj/20.11.2723 · Cited by 291
Fereidouni, F., Bader, A. N., & Gerritsen, H. C. (2012) · Optics Express · doi:10.1364/oe.20.012729 · Cited by 257
Sun, Y., Day, R. N., & Periasamy, A. (2011) · Nature Protocols · doi:10.1038/nprot.2011.364 · Cited by 240
Rapid Global Fitting of Large Fluorescence Lifetime Imaging Microscopy Datasets
Warren, S. C., Margineanu, A., Alibhai, D., Kelly, D. J., Talbot, C., Alexandrov, Y., Munro, I., Katan, M., Dunsby, C., & French, P. M. W. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070687 · Cited by 234
EGFR activation coupled to inhibition of tyrosine phosphatases causes lateral signal propagation
Reynolds, A. R., Tischer, C., Verveer, P. J., Rocks, O., & Bastiaens, P. I. H. (2003) · Nature Cell Biology · doi:10.1038/ncb981 · Cited by 234
“We analysed FLIM data by global analysis software as describe”
MethodSelf-citationClayton, A. H. A., Hanley, Q. S., & Verveer, P. J. (2004) · Journal of Microscopy · doi:10.1111/j.1365-2818.2004.01265.x · Cited by 231
“These cells were stimulated with epidermal growth factor and then fixed and incubated with a Cy3-labelled antibody against phosphotyrosine (PY72-Cy3, for more information about the assay and applications, see Verveer et al ., 2000b).”
MethodResultSelf-citationDynamic Fluorescence Anisotropy Imaging Microscopy inthe Frequency Domain (rFLIM)
Clayton, A. H. A., Hanley, Q. S., Arndt-Jovin, D. J., Subramaniam, V., & Jovin, T. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)73932-5 · Cited by 202
“…implemented with time-domain (Wang et al., 1991; Ghiggino et al., 1992; Scully et al., 1997; Cole et al., 2000) and frequency-domain (Marriot et al., 1991; Lakowicz et al., 1992; Piston et al., 1992; Gadella et al., 1993; Squire et al., 2000; Verveer et al., 2000; Hanley et al., 2001) techniques.”
BackgroundInfluentialPeter, M., Ameer-Beg, S. M., Hughes, M. K. Y., Keppler, M. D., Prag, S., Marsh, M., Vojnovic, B., & Ng, T. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.050153 · Cited by 196
“…invariant fluorescence lifetime components and calculation over all available data sets, or pixels) to data obtained using either time-domain (Beechem and Brand, 1986; Beechem and Haas, 1989) or frequency domain-based methodology (Verveer and Bastiaens, 2003; Verveer et al., 2000a,b, 2001).”
BackgroundMethodChorvat, D., & Chorvatova, A. (2009) · Laser Physics Letters · doi:10.1002/lapl.200810132 · Cited by 182
Multiplexing molecular tension sensors reveals piconewton force gradient across talin-1
Ringer, P., Weißl, A., Cost, A.-L., Freikamp, A., Sabass, B., Mehlich, A., Tramier, M., Rief, M., & Grashoff, C. (2017) · Nature Methods · doi:10.1038/nmeth.4431 · Cited by 180
TIMP: An R Package for Modeling Multi-Way Spectroscopic Measurements
Mullen, K. M., & Stokkum, I. H. M. V. (2007) · Journal of Statistical Software · doi:10.18637/jss.v018.i03 · Cited by 169
“The large memory requirements of the standard variable projection algorithm complicate its application, and sometimes pro-hibit its use entirely (as e.g., in the experience of Verveer, Squire, and Bastiaens (2000)).”
BackgroundFluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
Sparks, H., Kondo, H., Hooper, S., Munro, I., Kennedy, G., Dunsby, C., French, P., & Sahai, E. (2018) · Nature Communications · doi:10.1038/s41467-018-04820-6 · Cited by 54
Metadata
- Authors
- Verveer, P. J., Squire, A., & Bastiaens, P. I. H.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2000-04
- Volume
- 78
- Issue
- 4
- Pages
- 2127-2137
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1980759701
- Cited by
- 221
- References
- 32
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.