The Effects of Intense Submicrosecond Electrical Pulses on Cells
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
A simple electrical model for living cells predicts an increasing probability for electric field interactions with intracellular substructures of both prokaryotic and eukaryotic cells when the electric pulse duration is reduced into the sub-microsecond range. The validity of this hypothesis was verified experimentally by applying electrical pulses (durations 100 micros-60 ns, electric field intensities 3-150 kV/cm) to Jurkat cells suspended in physiologic buffer containing propidium iodide. Effects on Jurkat cells were assessed by means of temporally resolved fluorescence and light microscopy. For the longest applied pulses, immediate uptake of propidium iodide occurred consistent with electroporation as the cause of increased surface membrane permeability. For nanosecond pulses, more delayed propidium iodide uptake occurred with significantly later uptake of propidium iodide occurring after 60 ns pulses compared to 300 ns pulses. Cellular swelling occurred rapidly following 300 ns pulses, but was minimal following 60 ns pulses. These data indicate that submicrosecond pulses achieve temporally distinct effects on living cells compared to microsecond pulses. The longer pulses result in rapid permeability changes in the surface membrane that are relatively homogeneous across the cell population, consistent with electroporation, while shorter pulses cause surface membrane permeability changes that are temporally delayed and heterogeneous in their magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Intracellular effect of ultrashort electrical pulses
Schoenbach, K. H., Beebe, S. J., & Buescher, E. S. (2001) · Bioelectromagnetics · doi:10.1002/bem.71 · Cited by 548 · cited 2×
“…suspensions have yielded information on the electrical parameters of cellular substructures (Polevaya et al., 1999), cell models which take intracellular responses to external electric fields into account are still based on relatively crude assumptions (Foster, 2000; Schoenbach et al., 2001).”
BackgroundSelf-citationBeebe, S. J., Fox, P. M., Rec, L. J., Somers, K., Stark, R. H., & Schoenbach, K. H. (2002) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2002.1003872 · Cited by 420
Self-citationInteractions between electromagnetic fields and cells
Chiabrera, A., Nicolini, C. A., & Schwan, H. P. (1985) · Medical Entomology and Zoology · Cited by 389
Bioelectrics-new applications for pulsed power technology
Schoenbach, K. H., Katsuki, S., Stark, R. H., Buescher, E. S., & Beebe, S. J. (2002) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2002.1003873 · Cited by 366 · cited 2×
“We currently hypothesize (Schoenbach et al., 2002) that the dramatically increased energy deposition into intracellular structures that occurs with submicrosecond, compared to multimicrosecond, pulses plays a major role in the effects observed.”
BackgroundSelf-citationElectropermeabilization of Mammalian Cells to Macromolecules: Control by Pulse Duration
Rols, M.-P., & Teissié, J. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74060-3 · Cited by 347 · cited 1×
“membrane integrity in living cells (Rols and Teissie, 1998).”
Electroporation of Cells and Tissues
Weaver, J. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.ch94 · Cited by 299
Time domain dielectric spectroscopy study of human cells
Polevaya, Y., Ermolina, I., Schlesinger, M., Ginzburg, B.-Z., & Feldman, Y. (1999) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(99)00072-3 · Cited by 234 · cited 1×
“…based on time domain dielectric spectroscopy of cell suspensions have yielded information on the electrical parameters of cellular substructures (Polevaya et al., 1999), cell models which take intracellular responses to external electric fields into account are still based on relatively…”
BackgroundMedical applications of electroporation
Dev, S. B., Rabussay, D. P., Widera, G., & Hofmann, G. A. (2000) · IEEE Transactions on Plasma Science · doi:10.1109/27.842905 · Cited by 225
Gabriel, B., & Teissié, J. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78292-4 · Cited by 206 · cited 1×
“This asymmetric permeabilization of the cell membrane has been observed by others (Gabriel and Teissie, 1997; Djuzenova et al., 1996) and is assumed to be due to the increased potential at this location due to the contribution of the resting potential to the external field-induced potential.”
BackgroundThermal and nonthermal mechanisms of interaction of radio-frequency energy with biological systems
Foster, K. R. (2000) · IEEE Transactions on Plasma Science · doi:10.1109/27.842819 · Cited by 201 · cited 3×
“…suspensions have yielded information on the electrical parameters of cellular substructures (Polevaya et al., 1999), cell models which take intracellular responses to external electric fields into account are still based on relatively crude assumptions (Foster, 2000; Schoenbach et al., 2001).”
BackgroundThe Biomedical Engineering Handbook: Second Edition.
Kun, L. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.sec18 · Cited by 198
Gabriel, B., & Teissié, J. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77370-4 · Cited by 181
Djuzenova, C. S., Zimmermann, U., Frank, H., Sukhorukov, V. L., Richter, E., & Führ, G. (1996) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(96)00119-8 · Cited by 173 · cited 1×
“This asymmetric permeabilization of the cell membrane has been observed by others (Gabriel and Teissie, 1997; Djuzenova et al., 1996) and is assumed to be due to the increased potential at this location due to the contribution of the resting potential to the external field-induced potential.”
BackgroundMüller, K. J., Sukhorukov, V. L., & Zimmermann, U. (2001) · The Journal of Membrane Biology · doi:10.1007/s00232-001-0084-3 · Cited by 119 · cited 1×
“Information on the cellular effects of submicrosecond pulsed electric fields is limited (Müller et al., 2001).”
BackgroundMillisecond measurement of transport during and after an electroporation pulse
Prausnitz, M. R., Corbett, J. D., Gimm, J. A., Golan, D. E., Langer, R., & Weaver, J. C. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80363-2 · Cited by 69 · cited 2×
“A similar set-up has been used by Prausnitz et al. (1995) to perform millisecond measurements of transport during and after millisecond duration electroporation pulses.”
MethodIn Vitro and Ex Vivo Gene Delivery to Cells by Electroporation
Hui, S. W., & Li, L. H. (2003) · Humana Press eBooks · doi:10.1385/1-59259-080-2:157 · Cited by 20 · cited 1×
“The increase in cell size seen with pulses longer than 60 ns likely represents colloid osmotic swelling of cells in physiologic buffer, and as such, would be typical of electroporation with delayed resealing of the pores (Hui and Li, 2000).”
Background
Cited by
Plasma medicine: an introductory review
Kong, M. G., Kroesen, G., Morfill, G., Nosenko, T., Shimizu, T., van Dijk, J., & Zimmermann, J. L. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/11/115012 · Cited by 1,601
Tumor Ablation with Irreversible Electroporation
Al-Sakere, B., André, F., Bernat, C., Connault, E., Opolon, P., Davalos, R. V., Rubinsky, B., & Mir, L. M. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001135 · Cited by 490
Ultrashort electrical pulses open a new gateway into biological cells
Schoenbach, K. H., Joshi, R. P., Kolb, J. F., Chen, N., Stacey, M., Blackmore, P. F., Buescher, E. S., & Beebe, S. J. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2004.829009 · Cited by 404
Self-citationCalcium bursts induced by nanosecond electric pulses
Vernier, P. T., Sun, Y., Marcu, L., Salemi, S., Craft, C. M., & Gundersen, M. A. (2003) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2003.08.140 · Cited by 400
Bioelectric Effects of Intense Nanosecond Pulses
Schoenbach, K., Hargrave, B., Joshi, R., Kolb, J., Nuccitelli, R., Osgood, C., Pakhomov, A., Stacey, M., Swanson, R., White, J., et al. (2007) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2007.4339468 · Cited by 330
Self-citation
Metadata
- Authors
- Deng, J., Schoenbach, K. H., Stephen Buescher, E., Hair, P. S., Fox, P. M., & Beebe, S. J.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2003-04
- Volume
- 84
- Issue
- 4
- Pages
- 2709-2714
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1979444189
- Cited by
- 239
- References
- 17
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.