The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
The force exerted by a single kinesin molecule against a viscous load
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle Structure and Theories of Contraction
Huxley, A. F. (1957) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30128-8 · Cited by 2,318
Three-dimensional structure of myosin subfragment-1: a molecular motor
Rayment, I., Rypniewski, W., Schmidt-Base, K., Smith, R., Tomchick, D., Benning, M., Winkelmann, D., Wesenberg, G., & Holden, H. (1993) · Science · doi:10.1126/science.8316857 · Cited by 2,070
Single myosin molecule mechanics: piconewton forces and nanometre steps
Finer, J. T., Simmons, R. M., & Spudich, J. A. (1994) · Nature · doi:10.1038/368113a0 · Cited by 1,915
Flexural rigidity of microtubules and actin filaments measured from thermal fluctuations in shape.
Gittes, F., Mickey, B., Nettleton, J., & Howard, J. (1993) · The Journal of cell biology · doi:10.1083/jcb.120.4.923 · Cited by 1,817
Self-citationBead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Movement of microtubules by single kinesin molecules
Howard, J., Hudspeth, A. J., & Vale, R. D. (1989) · Nature · doi:10.1038/342154a0 · Cited by 885
Self-citationFluorescent actin filaments move on myosin fixed to a glass surface.
Kron, S. J., & Spudich, J. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6272 · Cited by 853
[39] Preparation of modified tubulins
Hyman, A., Drechsel, D., Kellogg, D., Salser, S., Sawin, K., Steffen, P., Wordeman, L., & Mitchison, T. (1991) · Methods in Enzymology · doi:10.1016/0076-6879(91)96041-o · Cited by 732
A novel brain ATPase with properties expected for the fast axonal transport motor
Brady, S. T. (1985) · Nature · doi:10.1038/317073a0 · Cited by 618
Arrangement of subunits in flagellar microtubules
Amos, L. A., & Klug, A. (1974) · Journal of Cell Science · doi:10.1242/jcs.14.3.523 · Cited by 514
Cited by
Brownian motors: noisy transport far from equilibrium
Reimann, P. (2002) · Physics Reports · doi:10.1016/s0370-1573(01)00081-3 · Cited by 2,589
Direct observation of the rotation of F1-ATPase
Noji, H., Yasuda, R., Yoshida, M., & Kinosita, K. (1997) · Nature · doi:10.1038/386299a0 · Cited by 2,236
Jülicher, F., Ajdari, A., & Prost, J. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.1269 · Cited by 1,870
Regulation of Contraction in Striated Muscle
Gordon, A. M., Homsher, E., & Regnier, M. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.853 · Cited by 1,737
Force and Velocity Measured for Single Molecules of RNA Polymerase
Wang, M. D., Schnitzer, M. J., Yin, H., Landick, R., Gelles, J., & Block, S. M. (1998) · Science · doi:10.1126/science.282.5390.902 · Cited by 892
Metadata
- Authors
- Hunt, A. J., Gittes, F., & Howard, J.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1994-08
- Volume
- 67
- Issue
- 2
- Pages
- 766-781
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1986790570
- Cited by
- 349
- References
- 31
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The force exerted by a single kinesin molecule against a viscous load. https://app.cochat.ai/papers/10.1016/s0006-3495(94)80537-5
- The paper
- Hunt, A. J., Gittes, F., & Howard, J. (1994). The force exerted by a single kinesin molecule against a viscous load. Biophysical Journal. https://doi.org/10.1016/s0006-3495(94)80537-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.