The force exerted by a single kinesin molecule against a viscous load
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle Structure and Theories of Contraction
Huxley, A. F. (1957) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30128-8 · Cited by 2,318
Three-dimensional structure of myosin subfragment-1: a molecular motor
Rayment, I., Rypniewski, W., Schmidt-Base, K., Smith, R., Tomchick, D., Benning, M., Winkelmann, D., Wesenberg, G., & Holden, H. (1993) · Science · doi:10.1126/science.8316857 · Cited by 2,070
Single myosin molecule mechanics: piconewton forces and nanometre steps
Finer, J. T., Simmons, R. M., & Spudich, J. A. (1994) · Nature · doi:10.1038/368113a0 · Cited by 1,915
Flexural rigidity of microtubules and actin filaments measured from thermal fluctuations in shape.
Gittes, F., Mickey, B., Nettleton, J., & Howard, J. (1993) · The Journal of cell biology · doi:10.1083/jcb.120.4.923 · Cited by 1,817
Self-citationBead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Movement of microtubules by single kinesin molecules
Howard, J., Hudspeth, A. J., & Vale, R. D. (1989) · Nature · doi:10.1038/342154a0 · Cited by 885
Self-citationFluorescent actin filaments move on myosin fixed to a glass surface.
Kron, S. J., & Spudich, J. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6272 · Cited by 853
[39] Preparation of modified tubulins
Hyman, A., Drechsel, D., Kellogg, D., Salser, S., Sawin, K., Steffen, P., Wordeman, L., & Mitchison, T. (1991) · Methods in Enzymology · doi:10.1016/0076-6879(91)96041-o · Cited by 732
A novel brain ATPase with properties expected for the fast axonal transport motor
Brady, S. T. (1985) · Nature · doi:10.1038/317073a0 · Cited by 618
Arrangement of subunits in flagellar microtubules
Amos, L. A., & Klug, A. (1974) · Journal of Cell Science · doi:10.1242/jcs.14.3.523 · Cited by 514
Cited by
Brownian motors: noisy transport far from equilibrium
Reimann, P. (2002) · Physics Reports · doi:10.1016/s0370-1573(01)00081-3 · Cited by 2,589
Direct observation of the rotation of F1-ATPase
Noji, H., Yasuda, R., Yoshida, M., & Kinosita, K. (1997) · Nature · doi:10.1038/386299a0 · Cited by 2,236
Jülicher, F., Ajdari, A., & Prost, J. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.1269 · Cited by 1,870
Regulation of Contraction in Striated Muscle
Gordon, A. M., Homsher, E., & Regnier, M. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.853 · Cited by 1,737
Probing the Relation Between Force—Lifetime—and Chemistry in Single Molecular Bonds
Evans, E. (2001) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.30.1.105 · Cited by 1,325
Force and Velocity Measured for Single Molecules of RNA Polymerase
Wang, M. D., Schnitzer, M. J., Yin, H., Landick, R., Gelles, J., & Block, S. M. (1998) · Science · doi:10.1126/science.282.5390.902 · Cited by 892
Self-organization of microtubules and motors
Ndlec, F. J., Surrey, T., Maggs, A. C., & Leibler, S. (1997) · Nature · doi:10.1038/38532 · Cited by 884
Kinbara, K., & Aida, T. (2005) · Chemical Reviews · doi:10.1021/cr030071r · Cited by 865
F1-ATPase Is a Highly Efficient Molecular Motor that Rotates with Discrete 120° Steps
Yasuda, R., Noji, H., Kinosita, K., & Yoshida, M. (1998) · Cell · doi:10.1016/s0092-8674(00)81456-7 · Cited by 798
Carter, N. J., & Cross, R. A. (2005) · Nature · doi:10.1038/nature03528 · Cited by 743
Okada, Y., Yamazaki, H., Sekine-Aizawa, Y., & Hirokawa, N. (1995) · Cell · doi:10.1016/0092-8674(95)90538-3 · Cited by 686
Kinesin and Dynein Move a Peroxisome in Vivo: A Tug-of-War or Coordinated Movement?
Kural, C., Kim, H., Syed, S., Goshima, G., Gelfand, V. I., & Selvin, P. R. (2005) · Science · doi:10.1126/science.1108408 · Cited by 613
Transcription Against an Applied Force
Yin, H., Wang, M. D., Svoboda, K., Landick, R., Block, S. M., & Gelles, J. (1995) · Science · doi:10.1126/science.270.5242.1653 · Cited by 591
Measurement of the Force-Velocity Relation for Growing Microtubules
Dogterom, M., & Yurke, B. (1997) · Science · doi:10.1126/science.278.5339.856 · Cited by 579
Force Generation by Microtubule Assembly/Disassembly in Mitosis and Related Movements
Inoué, S., & Salmon, E. D. (1995) · Molecular Biology of the Cell · doi:10.1091/mbc.6.12.1619 · Cited by 532
Molecular motors: structural adaptations to cellular functions
Howard, J. (1997) · Nature · doi:10.1038/39247 · Cited by 494
Self-citationThe design plan of kinesin motors
Vale, R. D., & Fletterick, R. J. (1997) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.13.1.745 · Cited by 474
Microtubules and microtubule-associated proteins
Mandelkow, E., & Mandelkow, E.-M. (1995) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(95)80047-6 · Cited by 458
Mechanical Rotation of the c Subunit Oligomer in ATP Synthase (F 0 F 1 ): Direct Observation
Sambongi, Y., Iko, Y., Tanabe, M., Omote, H., Iwamoto-Kihara, A., Ueda, I., Yanagida, T., Wada, Y., & Futai, M. (1999) · Science · doi:10.1126/science.286.5445.1722 · Cited by 446
Cooperative cargo transport by several molecular motors
Klumpp, S., & Lipowsky, R. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507363102 · Cited by 406
Kinesin Takes One 8-nm Step for Each ATP That It Hydrolyzes
Coy, D. L., Wagenbach, M., & Howard, J. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.6.3667 · Cited by 390
Self-citationIntermediate filaments mediate cytoskeletal crosstalk
Chang, L., & Goldman, R. D. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1438 · Cited by 386
Hunter, A. W., Caplow, M., Coy, D. L., Hancock, W. O., Diez, S., Wordeman, L., & Howard, J. (2003) · Molecular Cell · doi:10.1016/s1097-2765(03)00049-2 · Cited by 386
Self-citationRigidity of microtubules is increased by stabilizing agents.
Mickey, B., & Howard, J. (1995) · The Journal of cell biology · doi:10.1083/jcb.130.4.909 · Cited by 328
Self-citationFlexural rigidity of microtubules measured with the use of optical tweezers
Felgner, H., Frank, R., & Schliwa, M. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.2.509 · Cited by 301
Nishizaka, T., Oiwa, K., Noji, H., Kimura, S., Muneyuki, E., Yoshida, M., & Kinosita, K. (2004) · Nature Structural & Molecular Biology · doi:10.1038/nsmb721 · Cited by 277
Friedrich, B. M., Riedel-Kruse, I. H., Howard, J., & Jülicher, F. (2010) · Journal of Experimental Biology · doi:10.1242/jeb.039800 · Cited by 276
Self-citationThe load dependence of kinesin’s mechanical cycle
Coppin, C. M., Pierce, D. W., Hsu, L., & Vale, R. D. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.16.8539 · Cited by 256
Intermediate filaments are dynamic and motile elements of cellular architecture
Helfand, B. T., Chang, L., & Goldman, R. D. (2004) · Journal of Cell Science · doi:10.1242/jcs.00936 · Cited by 252
Spontaneous Oscillations of Collective Molecular Motors
Jülicher, F., & Prost, J. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.4510 · Cited by 248
Mechanochemical coupling of the motion of molecular motors to ATP hydrolysis
Astumian, R. D., & Bier, M. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79605-4 · Cited by 245
Ultrastructural Changes in Axons Following Exposure to Pulsed Radiofrequency Fields
Erdine, S., Bilir, A., Cosman, E. R., & Cosman Jr., E. R. (2009) · Pain Practice · doi:10.1111/j.1533-2500.2009.00317.x · Cited by 245
Molecular Sorting by Electrical Steering of Microtubules in Kinesin-Coated Channels
van den Heuvel, M. G. L., de Graaff, M. P., & Dekker, C. (2006) · Science · doi:10.1126/science.1124258 · Cited by 243
Kinesin Assembly and Movement in Cells
Verhey, K. J., Kaul, N., & Soppina, V. (2011) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-042910-155310 · Cited by 231
The force generated by a single kinesin molecule against an elastic load.
Meyhöfer, E., & Howard, J. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.2.574 · Cited by 222
Self-citationBiological applications of multifunctional magnetic nanowires (invited)
Reich, D. H., Tanase, M., Hultgren, A., Bauer, L. A., Chen, C. S., & Meyer, G. J. (2003) · Journal of Applied Physics · doi:10.1063/1.1558672 · Cited by 216
Assembly and positioning of microtubule asters in microfabricated chambers
Holy, T. E., Dogterom, M., Yurke, B., & Leibler, S. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6228 · Cited by 211
Levi, V., Serpinskaya, A. S., Gratton, E., & Gelfand, V. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.067843 · Cited by 202
“(30) assayed the motion of microtubules of different lengths moving across high-density kinesin-coated glass surfaces through a medium of viscosity similar to that of the cytoplasm.”
BackgroundComputer simulations reveal motor properties generating stable antiparallel microtubule interactions
Nédélec, F. (2002) · The Journal of Cell Biology · doi:10.1083/jcb.200202051 · Cited by 194
“To yield more accurate drag forces, the factor H loge(2 m/25 nm) 4.38 corrects for the tubular shape of the microtubule (Hunt et al., 1994).”
BackgroundInfluentialF‐ATPase: specific observation of the rotating c subunit oligomer of EFoEF1
Pänke, O., Gumbiowski, K., Junge, W., & Engelbrecht, S. (2000) · FEBS Letters · doi:10.1016/s0014-5793(00)01436-8 · Cited by 189
Direct Observation of the Rotation of ε Subunit in F1-ATPase
Kato-Yamada, Y., Noji, H., Yasuda, R., Kinosita, K., & Yoshida, M. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.31.19375 · Cited by 183
Rotation of F1-ATPase: How an ATP-Driven Molecular Machine May Work
Kinosita, K., Adachi, K., & Itoh, H. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.110502.132716 · Cited by 178
“is higher than the estimate in Equations 2 and 3 (20).”
MethodResultAlternating Site Mechanism of the Kinesin ATPase
Gilbert, S. P., Moyer, M. L., & Johnson, K. A. (1998) · Biochemistry · doi:10.1021/bi971117b · Cited by 172
A Bending Mode Analysis for Growing Microtubules: Evidence for a Velocity-Dependent Rigidity
Janson, M. E., & Dogterom, M. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.038877 · Cited by 170
“The drag coefficient, which determines the force applied, depends on experimental details such as the distance between microtubule and coverslip (Gittes et al., 1993; Hunt et al., 1994; Mickey and Howard, 1995).”
BackgroundThe C-Terminus of Tubulin Increases Cytoplasmic Dynein and Kinesin Processivity
Wang, Z., & Sheetz, M. P. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76743-9 · Cited by 162
“Motion analysis of moving beads or microtubules has also clarified the magnitude of the force generated and important aspects of the motor movement on the filament (Coppin et al., 1996, 1997; Gelles et al., 1988; Svoboda et al., 1994; Hunt et al., 1994).”
BackgroundDiffusible Crosslinkers Generate Directed Forces in Microtubule Networks
Lansky, Z., Braun, M., Lüdecke, A., Schlierf, M., ten Wolde, P. R., Janson, M. E., & Diez, S. (2015) · Cell · doi:10.1016/j.cell.2015.01.051 · Cited by 161
“The viscous drag exerted by the solution was neglected due to its small contribution at low velocities (Hunt et al., 1994; Tawada and Sekimoto, 1991).”
BackgroundTracking Single Kinesin Molecules in the Cytoplasm of Mammalian Cells
Cai, D., Verhey, K. J., & Meyhöfer, E. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.100206 · Cited by 158
“KHC(1-891) was genetically tagged with a monomeric version of the fluorescent protein (FP) Citrine (mCit), a brighter and more photostable version of EYFP (18).”
BackgroundMethodInfluentialAnalysis of the migration behaviour of single microtubules in electric fields
Stracke, R., Böhm, K. J., Wollweber, L., Tuszynski, J. A., & Unger, E. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00251-6 · Cited by 147
Electrophoresis of individual microtubules in microchannels
van den Heuvel, M. G. L., de Graaff, M. P., Lemay, S. G., & Dekker, C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608316104 · Cited by 62
Kinesin’s backsteps under mechanical load
Hyeon, C., Klumpp, S., & Onuchic, J. N. (2009) · Physical Chemistry Chemical Physics · doi:10.1039/b903536b · Cited by 51
Single Fungal Kinesin Motor Molecules Move Processively along Microtubules
Lakämper, S., Kallipolitou, A., Woehlke, G., Schliwa, M., & Meyhöfer, E. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74991-1 · Cited by 44
“Moreover, later work showed that single conventional kinesin molecules are even capable of moving processively, albeit slower, when challenged by substantial elastic force up to 5–7 pN (Hunt et al., 1994; Kojima et al., 1997; Meyhöfer and Howard, 1995; Svoboda et al., 1993; Visscher et al., 1999).”
BackgroundYoshida, M. W., Hakozaki, M., & Goshima, G. (2023) · Nature Plants · doi:10.1038/s41477-023-01397-x · Cited by 20
Metadata
- Authors
- Hunt, A. J., Gittes, F., & Howard, J.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1994-08
- Volume
- 67
- Issue
- 2
- Pages
- 766-781
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1986790570
- Cited by
- 349
- References
- 33
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.