Simulations of the Erythrocyte Cytoskeleton at Large Deformation. II. Micropipette Aspiration
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Coarse-grained molecular models of the erythrocyte membrane's spectrin cytoskeleton are presented in Monte Carlo simulations of whole cells in micropipette aspiration. The nonlinear chain elasticity and sterics revealed in more microscopic cytoskeleton models (developed in a companion paper; Boey et al., 1998. Biophys. J. 75:1573-1583) are faithfully represented here by two- and three-body effective potentials. The number of degrees of freedom of the system are thereby reduced to a range that is computationally tractable. Three effective models for the triangulated cytoskeleton are developed: two models in which the cytoskeleton is stress-free and does or does not have internal attractive interactions, and a third model in which the cytoskeleton is prestressed in situ. These are employed in direct, finite-temperature simulations of erythrocyte deformation in a micropipette. All three models show reasonable agreement with aspiration measurements made on flaccid human erythrocytes, but the prestressed model alone yields optimal agreement with fluorescence imaging experiments. Ensemble-averaging of nonaxisymmetrical, deformed structures exhibiting anisotropic strain are thus shown to provide an answer to the basic question of how a triangulated mesh such as that of the red cell cytoskeleton deforms in experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reversible Unfolding of Individual Titin Immunoglobulin Domains by AFM
Rief, M., Gautel, M., Oesterhelt, F., Fernandez, J. M., & Gaub, H. E. (1997) · Science · doi:10.1126/science.276.5315.1109 · Cited by 3,077
Dynamic strength of molecular adhesion bonds
Evans, E., & Ritchie, K. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78802-7 · Cited by 2,549
Marko, J. F., & Siggia, E. D. (1995) · Macromolecules · doi:10.1021/ma00130a008 · Cited by 2,307
Elasticity of Semiflexible Biopolymer Networks
MacKintosh, F. C., Käs, J., & Janmey, P. A. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4425 · Cited by 1,068
Mechanics and Thermodynamics of Biomembranes
Evans, E. A., Skalak, R., & Weinbaum, S. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138234 · Cited by 954
Mohandas, N., & Evans, E. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.004035 · Cited by 560
Thermoelasticity of red blood cell membrane
Waugh, R., & Evans, E. A. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85239-x · Cited by 427
Mechanical Properties of the Red Cell Membrane
Rand, R. P., & Burton, A. C. (1964) · Biophysical Journal · doi:10.1016/s0006-3495(64)86773-4 · Cited by 403
Visualization of the hexagonal lattice in the erythrocyte membrane skeleton.
Liu, S. C., Derick, L. H., & Palek, J. (1987) · The Journal of cell biology · doi:10.1083/jcb.104.3.527 · Cited by 401
Visualization of the protein associations in the erythrocyte membrane skeleton.
Byers, T. J., & Branton, D. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.18.6153 · Cited by 395
Cited by
Micropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284
Tensegrity I. Cell structure and hierarchical systems biology
Ingber, D. E. (2003) · Journal of Cell Science · doi:10.1242/jcs.00359 · Cited by 1,265
Mechanics of the human red blood cell deformed by optical tweezers
Dao, M., Lim, C. T., & Suresh, S. (2003) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2003.09.019 · Cited by 812
Mechanical behavior in living cells consistent with the tensegrity model
Wang, N., Naruse, K., Stamenović, D., Fredberg, J. J., Mijailovich, S. M., Tolić-Nørrelykke, I. M., Polte, T., Mannix, R., & Ingber, D. E. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.141199598 · Cited by 741
Mechanical models for living cells—a review
Lim, C. T., Zhou, E. H., & Quek, S. T. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.008 · Cited by 719
Cell prestress. I. Stiffness and prestress are closely associated in adherent contractile cells
Wang, N., Tolić-Nørrelykke, I. M., Chen, J., Mijailovich, S. M., Butler, J. P., Fredberg, J. J., & Stamenović, D. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00269.2001 · Cited by 669
“Common stress-supported models of cell deformability include the cortical membrane model (15, 16, 24, 59), the cable nets model (44), and the tensegrity model (10, 27, 46).”
BackgroundA Multiscale Red Blood Cell Model with Accurate Mechanics, Rheology, and Dynamics
Fedosov, D. A., Caswell, B., & Karniadakis, G. E. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.02.002 · Cited by 618
Shape and Biomechanical Characteristics of Human Red Blood Cells in Health and Disease
Diez-Silva, M., Dao, M., Han, J., Lim, C.-T., & Suresh, S. (2010) · MRS Bulletin · doi:10.1557/mrs2010.571 · Cited by 595
Shape transitions of fluid vesicles and red blood cells in capillary flows
Noguchi, H., & Gompper, G. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504243102 · Cited by 580
Tensegrity, cellular biophysics, and the mechanics of living systems
Ingber, D. E., Wang, N., & Stamenović, D. (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/4/046603 · Cited by 485
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Materialia · doi:10.1016/j.actamat.2007.04.022 · Cited by 467
(2009) · JuSER (Forschungszentrum Jülich) · Cited by 465
Spectrin-Level Modeling of the Cytoskeleton and Optical Tweezers Stretching of the Erythrocyte
Li, J., Dao, M., Lim, C. T., & Suresh, S. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.047332 · Cited by 426
Dahl, K. N., Kahn, S. M., Wilson, K. L., & Discher, D. E. (2004) · Journal of Cell Science · doi:10.1242/jcs.01357 · Cited by 424
Self-citationMicroengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Accurate Coarse-Grained Modeling of Red Blood Cells
Pivkin, I. V., & Karniadakis, G. E. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.118105 · Cited by 391
Cancer cell detection in tissue sections using AFM
Lekka, M., Gil, D., Pogoda, K., Dulińska-Litewka, J., Jach, R., Gostek, J., Klymenko, O., Prauzner-Bechcicki, S., Stachura, Z., Wiltowska-Zuber, J., et al. (2012) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2011.12.013 · Cited by 367
Numerical Simulation of Flowing Blood Cells
Freund, J. B. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141349 · Cited by 323
The biomechanics toolbox: experimental approaches for living cells and biomolecules
Van Vliet, K. J., Bao, G., & Suresh, S. (2003) · Acta Materialia · doi:10.1016/j.actamat.2003.09.001 · Cited by 306
Flow-induced clustering and alignment of vesicles and red blood cells in microcapillaries
McWhirter, J. L., Noguchi, H., & Gompper, G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0811484106 · Cited by 300
Multiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
Blood Flow and Cell-Free Layer in Microvessels
FEDOSOV, D. A., CASWELL, B., POPEL, A. S., & KARNIADAKIS, G. E. (2010) · Microcirculation · doi:10.1111/j.1549-8719.2010.00056.x · Cited by 277
Dissipative Particle Dynamics (DPD): An Overview and Recent Developments
Liu, M. B., Liu, G. R., Zhou, L. W., & Chang, J. Z. (2015) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9124-x · Cited by 273
Cytoskeletal dynamics of human erythrocyte
Li, J., Lykotrafitis, G., Dao, M., & Suresh, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700257104 · Cited by 270
Simulating tissue mechanics with agent-based models: concepts, perspectives and some novel results
Van Liedekerke, P., Palm, M. M., Jagiella, N., & Drasdo, D. (2015) · Computational Particle Mechanics · doi:10.1007/s40571-015-0082-3 · Cited by 262
Introductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
Gompper, G., Ihle, T., Kroll, D. M., & Winkler, R. G. (2009) · Advanced Computer Simulation Approaches for Soft Matter Sciences III · doi:10.1007/978-3-540-87706-6_1 · Cited by 229
Optical Measurement of Cell Membrane Tension
Popescu, G., Ikeda, T., Goda, K., Best-Popescu, C. A., Laposata, M., Manley, S., Dasari, R. R., Badizadegan, K., & Feld, M. S. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.218101 · Cited by 223
Molecularly based analysis of deformation of spectrin network and human erythrocyte
Dao, M., Li, J., & Suresh, S. (2006) · Materials Science and Engineering: C · doi:10.1016/j.msec.2005.08.020 · Cited by 221
Honda, H., Tanemura, M., & Nagai, T. (2004) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2003.10.001 · Cited by 216
Lipid bilayer and cytoskeletal interactions in a red blood cell
Peng, Z., Li, X., Pivkin, I. V., Dao, M., Karniadakis, G. E., & Suresh, S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1311827110 · Cited by 194
Deformation and dynamics of red blood cells in flow through cylindrical microchannels
Fedosov, D. A., Peltomäki, M., & Gompper, G. (2014) · Soft Matter · doi:10.1039/c4sm00248b · Cited by 190
Adhesively-Tensed Cell Membranes: Lysis Kinetics and Atomic Force Microscopy Probing
Hategan, A., Law, R., Kahn, S., & Discher, D. E. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74697-9 · Cited by 187
“…undoubtedly follow very similar physics as suggested by FIGURE 5 Sketch representing the extension and dilation of the cytoskeleton in an intact red cell during either AFM indentation ( A ) or micropipette aspiration ( B ) (Discher et al., 1994). network simulations (e.g., Discher et al., 1998).”
Self-citationDenais, C., & Lammerding, J. (2014) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4899-8032-8_20 · Cited by 182
More Than a Leak Sealant. The Mechanical Properties of Callose in Pollen Tubes
Parre, E., & Geitmann, A. (2005) · Plant Physiology · doi:10.1104/pp.104.050773 · Cited by 180
“These studies used, in particular, mammalian cells such as fibroblasts and erythrocytes (Discher et al., 1988; Sokabe et al., 1991; Nash and Gratzer, 1993; Knowles et al., 1994; Yuan et al., 1995).”
BackgroundOpposing views on tensegrity as a structural framework for understanding cell mechanics
Ingber, D. E., Heidemann, S. R., Lamoureux, P., & Buxbaum, R. E. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1663 · Cited by 173
Simulations of the Erythrocyte Cytoskeleton at Large Deformation. I. Microscopic Models
Boey, S. K., Boal, D. H., & Discher, D. E. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74075-5 · Cited by 169
“Although a comparison with networks of Hookean springs proves useful in the neighborhood of zero stress, such distinguishing model features as a constant shear modulus under network compression and a limiting contour area appear to be captured more effectively by balancing worm-like chain elasticity (Marko and Siggia,…”
BackgroundResultSelf-citationA fluorescence energy transfer‐based mechanical stress sensor for specific proteins in situ
Meng, F., Suchyna, T. M., & Sachs, F. (2008) · The FEBS Journal · doi:10.1111/j.1742-4658.2008.06461.x · Cited by 166
Microcapsule mechanics: From stability to function
Neubauer, M. P., Poehlmann, M., & Fery, A. (2014) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2013.11.016 · Cited by 165
Nmezi, B., Xu, J., Fu, R., Armiger, T. J., Rodriguez-Bey, G., Powell, J. S., Ma, H., Sullivan, M., Tu, Y., Chen, N. Y., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1810070116 · Cited by 165
“To confirm the strain-dependent localization of the A- and Btype lamins, we used micropipette aspiration to induce and increase strain and visualize lamin intensity at the tip in the pipette, which is the region of highest strain (22) (Fig.”
MethodThe Fluid Mechanics of Cancer and Its Therapy
Koumoutsakos, P., Pivkin, I., & Milde, F. (2013) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120710-101102 · Cited by 129
“Various modeling approaches have been used for them (Boal et al. 1992; Discher et al. 1998; Eggleton & Popel 1998; Fedosov et al. 2010; Freund & Orescanin 2011; Hansen et al. 1997; Li et al. 2005, 2007; Liu & Liu 2006; Noguchi & Gompper 2005; Pozrikidis 2005; Skotheim & Secomb 2007; Wu & Aidun…”
MethodRed blood cell dynamics: from cell deformation to ATP release
Wan, J., Forsyth, A. M., & Stone, H. A. (2011) · Integrative Biology · doi:10.1039/c1ib00044f · Cited by 88
Metadata
- Authors
- Discher, D. E., Boal, D. H., & Boey, S. K.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-09
- Volume
- 75
- Issue
- 3
- Pages
- 1584-1597
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2139020009
- Cited by
- 354
- References
- 18
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.