Non-invasive assessment of the atrial cycle length during atrial fibrillation in man: introducing, validating and illustrating a new ECG method
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Atrial fibrillation (AF) in man has previously been shown to include a wide variety of atrial activity. Assessment of the characteristics of this arrhythmia with a commonly applicable tool may therefore be important in the choice and evaluation of different therapeutic strategies. As the AF cycle length has been shown to correlate locally with atrial refractoriness and globally with the degree of atrial organization, with, in general, shorter cycle length during apparently random AF compared to more organized AF, we have developed a new method for non-invasive assessment of the AF cycle length using the surface and the esophagus (ESO) ECG. METHODS AND RESULTS: From the frequency spectrum of the residual ECG, created by suppression of the QRST complexes, the dominant atrial cycle length (DACL) was derived. By comparison with multiple intracardiac simultaneously acquired right and left AF cycle lengths in patients with paroxysmal AF, we found that the DACL in lead V1, ranging from 130 to 185 ms, well represented a spatial average of the right AF cycle lengths, whereas the DACL in the ESO ECG, ranging from 140 to 185 ms, reflected both the right and the left AF cycle length, where the influence from each structure depended on the atrial anatomy of the individual, as determined by MRI. In patients with chronic AF, the method was capable of following changes in the AF cycle length due to administration of D,L-sotalol and 5 min of ECG recording was sufficient for the DACL to be reproducible. CONCLUSIONS: We conclude that this new non-invasive method, named 'Frequency Analysis of Fibrillatory ECG' (FAF-ECG), is capable of assessing both the magnitude and the dynamics of the atrial fibrillation cycle length in man.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The surgical treatment of atrial fibrillation
Cox, J. L., Schuessler, R. B., D’Agostino, H. J., Stone, C. M., Chang, B.-C., Cain, M. E., Corr, P. B., & Boineau, J. P. (1991) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36684-x · Cited by 1,464
A Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency Ablation
Jai¨s, P., Hai¨ssaguerre, M., Shah, D. C., Chouairi, S., Gencel, L., Hocini, M., & Cle´menty, J. (1997) · Circulation · doi:10.1161/01.cir.95.3.572 · Cited by 1,117
High-density mapping of electrically induced atrial fibrillation in humans.
Konings, K. T., Kirchhof, C. J., Smeets, J. R., Wellens, H. J., Penn, O. C., & Allessie, M. A. (1994) · Circulation · doi:10.1161/01.cir.89.4.1665 · Cited by 962
Cox, J. L., Canavan, T. E., Schuessler, R. B., CAIN, M. E., Lindsay, B. D., Stone, C. M., Smith, P. K., Corr, P. B., & Boineau, J. P. (1991) · PubMed · Cited by 682
Rensma, P. L., Allessie, M. A., Lammers, W. J., Bonke, F. I., & Schalij, M. J. (1988) · Circulation Research · doi:10.1161/01.res.62.2.395 · Cited by 640
High-density mapping of electrically induced atrial fibrillation in humans
Konings, K. T. S., Kirchhof, C. J. H. J., Smeets, J. R. L. M., Wellens, H. J. J., Penn, O. C., & Allessie, M. A. (2000) · Professor Hein J.J. Wellens: 33 Years of Cardiology and Arrhythmology · doi:10.1007/978-94-011-4110-9_54 · Cited by 560
Konings, K. T. S., Smeets, J. L. R. M., Penn, O. C., Wellens, H. J. J., & Allessie, M. A. (1997) · Circulation · doi:10.1161/01.cir.95.5.1231 · Cited by 452
Characterization of Atrial Fibrillation in Man: Studies Following Open Heart Surgery*
WELLS, J. L., KARP, R. B., KOUCHOUKOS, N. T., MACLEAN, W. A. H., JAMES, T. N., & WALDO, A. L. (1978) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1978.tb03504.x · Cited by 291
Kumagai, K., Khrestian, C., & Waldo, A. L. (1997) · Circulation · doi:10.1161/01.cir.95.2.511 · Cited by 236
Slocum, J., Sahakian, A., & Swiryn, S. (1992) · Journal of Electrocardiology · doi:10.1016/0022-0736(92)90123-h · Cited by 191
Atrial activation during chronic atrial fibrillation in patients with isolated mitral valve disease
Harada, A., Sasaki, K., Fukushima, T., Ikeshita, M., Asano, T., Yamauchi, S., Tanaka, S., & Shoji, T. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00824-1 · Cited by 163
STEINHAUS, B. M. (1989) · Circulation Research · doi:10.1161/01.res.64.3.449 · Cited by 154
Atrial Flutter Mapping and Ablation I: Studying Atrial Flutter Mechanisms by Mapping and Entrainment
COSIO, F. G., ARRIBAS, F., LÓPEZ‐GIL, M., & PALACIOS, J. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03368.x · Cited by 111
Holm, M., Johansson, R., Brandt, J., Lührs, C., & Olsson, S. B. (1997) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a015233 · Cited by 104
Self-citationRelationship of atrial fibrillatory wave amplitude to left atrial size and etiology of heart disease
Morganroth, J., Horowitz, L. N., Josephson, M. E., & Kastor, J. A. (1979) · American Heart Journal · doi:10.1016/0002-8703(79)90354-5 · Cited by 58
Origin of the atrial electrogram recorded from the esophagus.
Prystowsky, E. N., Pritchett, E. L. C., & Gallagher, J. J. (1980) · Circulation · doi:10.1161/01.cir.61.5.1017 · Cited by 40
Clinical Significance of Fibrillatory Wave Amplitude
Li, Y., Hwang, J., Tseng, Y.-Z., Kuan, P., & Lien, W.-P. (1995) · CHEST Journal · doi:10.1378/chest.108.2.359 · Cited by 32
Relation between QT and RR intervals during exercise testing in atrial fibrillation
EHLERT, F. A., Goldberger, J. J., Rosenthal, J. E., & Kadish, A. H. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90614-5 · Cited by 30
Biatrial electrograms during coarse atrial fibrillation and flutter-fibrillation
Leier, C. V., & Schaal, S. F. (1980) · American Heart Journal · doi:10.1016/0002-8703(80)90348-8 · Cited by 21
Cited by
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
Principal Component Analysis in ECG Signal Processing
Castells, F., Laguna, P., Sörnmo, L., Bollmann, A., & Roig, J. M. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/74580 · Cited by 371
Petrutiu, S., Sahakian, A. V., & Swiryn, S. (2007) · EP Europace · doi:10.1093/europace/eum096 · Cited by 221
Bollmann, A., Husser, D., Mainardi, L., Lombardi, F., Langley, P., Murray, A., Rieta, J. J., Millet, J., Olsson, S. B., Stridh, M., et al. (2006) · EP Europace · doi:10.1093/europace/eul113 · Cited by 219
“1%.(16) In persistent AF, there is minor short-term rate variability within 30 min,(16,17,39) whereas repeated daily frequency measurements on identical medication at the same time under similar conditions disclose an insignificant fibrillatory rate variability.”
BackgroundMethodResultMatsuo, S., Lellouche, N., Wright, M., Bevilacqua, M., Knecht, S., Nault, I., Lim, K.-T., Arantes, L., O'Neill, M. D., Platonov, P. G., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.01.081 · Cited by 205
“The bsolute difference between the surface AFCL and the ntracardiac CL (both LAA CL and RAA CL) was similar o that of a previous study using digital signal processing (6).”
Result
Metadata
- Authors
- Holm, M.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-04
- Volume
- 38
- Issue
- 1
- Pages
- 69-81
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2013074517
- Cited by
- 275
- References
- 19
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.