We investigated high-precision Pb isotope ratio analysis by multi-collector-inductively coupled plasma-mass spectrometry (MC-ICP-MS) using added thallium as an internal isotopic standard to correct for mass dependent isotopic fractionation. We compared MC-ICP-MS analysis of both an inter-laboratory standard, NBS 981, and geological samples to conventional thermal ionization mass spectrometry (TIMS). As expected, we found that analytical error in the latter was dominated by mass fractionation. In MC-ICP-MS, we found that fractionation appears to follow the exponential law, but that the fractionation coefficients, f, of Tl and Pb were not identical. This difference in fractionation coefficients cannot be compensated for by renormalizing to a different Tl isotopic composition as done in other studies. We found, however, that the fPb/fTl ratio was constant over the course of an analytical session, allowing fPb to be calculated from fTl. An exponential law correction was then applied to the Pb isotope measurements which effectively eliminates errors associated with mass fractionation. Precision for the MC-ICP-MS analyses ranged from a factor of 2 to a factor of 6 better than for TIMS analyses for the 206Pb/204Pb and 208Pb/206Pb ratios respectively. Residual error in the MC-ICP-MS analyses was dominated by error in the analysis of 204Pb, perhaps in part due to random errors introduced by correcting for a 204Hg isobaric interference. We also found systematic errors in the MC-ICP-MS analyses compared to TIMS determinations that may be due to uneven background and collector biases in the instrument used. We found that these systematic errors were the same for both NBS 981 and the geological samples, so accurate correction factors could be generated from the standard analyses to correct the sample analyses. MC-ICP-MS has the additional advantages of requiring less preparative chemistry, less instrument time, and considerably less labor overall.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Lu-Hf isotope geochemistry of chondrites and the evolution of the mantle-crust system
Blichert-Toft, J., & Albarède, F. (1997) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(97)00040-x · Cited by 3,225
Self-citationThe thermodynamic properties of isotopic substances
Urey, H. C. (1947) · Journal of the Chemical Society (Resumed) · doi:10.1039/jr9470000562 · Cited by 2,544
Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry
Maréchal, C. N., Télouk, P., & Albarède, F. (1999) · Chemical Geology · doi:10.1016/s0009-2541(98)00191-0 · Cited by 1,360
Self-citationCa isotope fractionation on the Earth and other solar system materials
Russell, W. A., Papanastassiou, D. A., & Tombrello, T. A. (1978) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(78)90105-9 · Cited by 1,055
Janne Blichert-toft, B., Chauvel, C., & Albarède, F. (1997) · Contributions to Mineralogy and Petrology · doi:10.1007/s004100050278 · Cited by 934
Self-citationEvaluation of a 202 Pb- 205 Pb Double Spike for High - Precision Lead Isotope Analysis. *
Todt, W., Cliff, R. A., Hanser, A., & Hofmann, A. W. (2013) · Geophysical monograph · doi:10.1029/gm095p0429 · Cited by 685
Hirata, T., & Nesbitt, R. W. (1995) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(95)00144-1 · Cited by 371
Belshaw, N. S., Freedman, P. A., O’Nions, R. K., Frank, M., & Guo, Y. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14150-7 · Cited by 332
Walder, A. J., & Freedman, P. A. (1992) · Journal of Analytical Atomic Spectrometry · doi:10.1039/ja9920700571 · Cited by 255
Hafnium–tungsten chronometry and the timing of terrestrial core formation
Lee, D.-C., & Halliday, A. N. (1995) · Nature · doi:10.1038/378771a0 · Cited by 251
Cited by
Chu, N.-C., Taylor, R. N., Chavagnac, V., Nesbitt, R. W., Boella, R. M., Milton, J. A., German, C. R., Bayon, G., & Burton, K. (2002) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b206707b · Cited by 1,253
High‐precision isotopic characterization of USGS reference materials by TIMS and MC‐ICP‐MS
Weis, D., Kieffer, B., Maerschalk, C., Barling, J., de Jong, J., Williams, G. A., Hanano, D., Pretorius, W., Mattielli, N., Scoates, J. S., et al. (2006) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2006gc001283 · Cited by 1,118
Fore‐arc basalts and subduction initiation in the Izu‐Bonin‐Mariana system
Reagan, M. K., Ishizuka, O., Stern, R. J., Kelley, K. A., Ohara, Y., Blichert‐Toft, J., Bloomer, S. H., Cash, J., Fryer, P., Hanan, B. B., et al. (2010) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2009gc002871 · Cited by 826
Vervoort, J. D., Patchett, P. J., Söderlund, U., & Baker, M. (2004) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2004gc000721 · Cited by 579
Precise and accurate isotopic measurements using multiple-collector ICPMS
Albarède, F., Telouk, P., Blichert-Toft, J., Boyet, M., Agranier, A., & Nelson, B. (2004) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2003.11.024 · Cited by 570
Self-citationSiebert, C., Nägler, T. F., & Kramers, J. D. (2001) · Geochemistry Geophysics Geosystems · doi:10.1029/2000gc000124 · Cited by 456
Tracing Source Pollution in Soils Using Cadmium and Lead Isotopes
Cloquet, C., Carignan, J., Libourel, G., Sterckeman, T., & Perdrix, E. (2006) · Environmental Science & Technology · doi:10.1021/es052232+ · Cited by 336
Thirlwall, M. F. (2002) · Chemical Geology · doi:10.1016/s0009-2541(01)00365-5 · Cited by 325
Present Trends and the Future of Zircon in Geochronology: Laser Ablation ICPMS
Kosler, J. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530243 · Cited by 324
Accurate and precise determination of isotopic ratios by MC‐ICP‐MS: A review
Yang, L. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20251 · Cited by 285
Wombacher, F., Rehkämper, M., Mezger, K., & Münker, C. (2003) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(03)00389-2 · Cited by 266
Archer, C., & Vance, D. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b315853e · Cited by 265
Schoenberg, R., & von Blanckenburg, F. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.11.025 · Cited by 230
The origin of atmospheric particles in Paris: a view through carbon and lead isotopes
Widory, D., Roy, S., Le Moullec, Y., Goupil, G., Cocherie, A., & Guerrot, C. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.11.001 · Cited by 219
Deng, J., Liu, X., Wang, Q., Dilek, Y., & Liang, Y. (2017) · GSA Bulletin · doi:10.1130/b31609.1 · Cited by 215
Gasperini, D., Blichert‐Toft, J., Bosch, D., Del Moro, A., Macera, P., & Albarède, F. (2002) · Journal of Geophysical Research: Solid Earth · doi:10.1029/2001jb000418 · Cited by 213
Self-citationSims, K. W. W., Goldstein, S. J., Blichert-toft, J., Perfit, M. R., Kelemen, P., Fornari, D. J., Michael, P., Murrell, M. T., Hart, S. R., DePaolo, D. J., et al. (2002) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(02)00909-2 · Cited by 212
Iron isotopes in hot springs along the Juan de Fuca Ridge
Sharma, M., Polizzotto, M., & Anbar, A. D. (2001) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(01)00538-6 · Cited by 202
Deschamps, F., Guillot, S., Godard, M., Chauvel, C., Andreani, M., & Hattori, K. (2010) · Chemical Geology · doi:10.1016/j.chemgeo.2009.10.002 · Cited by 196
“Pb isotopic ratios weremeasured on a NU 500MC-ICP-MS in static multicollection mode, using the Tl normalization described by White et al. (2000).”
MethodArnold, G. L., Weyer, S., & Anbar, A. D. (2004) · Analytical Chemistry · doi:10.1021/ac034601v · Cited by 194
Rehkämper, M., & Mezger, K. (2000) · J. Anal. At. Spectrom. · doi:10.1039/b005262k · Cited by 186
Pearson, N. J., Alard, O., Griffin, W. L., Jackson, S. E., & O’Reilly, S. Y. (2002) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(01)00823-7 · Cited by 180
Cloquet, C., Carignan, J., & Libourel, G. (2006) · Environmental Science & Technology · doi:10.1021/es0609654 · Cited by 172
Nielsen, S. G., Rehkämper, M., Baker, J., & Halliday, A. N. (2004) · Chemical Geology · doi:10.1016/j.chemgeo.2003.11.006 · Cited by 167
“Similar observations have since been made for a number of other element pairs (Anbar et al., 2001; White et al., 2000; Wombacher et al., 2003; Woodhead, 2002).”
ResultAnbar, A. D., Knab, K. A., & Barling, J. (2001) · Analytical Chemistry · doi:10.1021/ac000829w · Cited by 159
Comprehensive Chemical and Isotopic Analyses of Basalt and Sediment Reference Materials
Chauvel, C., Bureau, S., & Poggi, C. (2011) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2010.00086.x · Cited by 158
“Lead isotopic ratios were measured using the thallium addition technique for mass bias correction (White et al. 2000; see results in Table 2) and further normalised to the NIST SRM 981 value recommended by Galer and Abouchami (1998).”
Method
Metadata
- Authors
- White, W. M., Albarède, F., & Télouk, P.
- Venue
- Chemical Geology
- Publisher
- Elsevier BV
- Published
- 2000-06
- Volume
- 167
- Issue
- 3-4
- Pages
- 257-270
- ISSN
- 0009-2541 (ISSN-L)
- OpenAlex
- W1972359411
- Cited by
- 568
- References
- 16
- FWCI
- 16.89
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.