The pathologic measurement of polyp size is preferable to the endoscopic estimate
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The evolution of cancer of the colon and rectum
Muto, T., Bussey, H. J. R., & Morson, B. C. (1975) · Cancer · doi:10.1002/cncr.2820360944 · Cited by 2,118
Long-Term Risk of Colorectal Cancer after Excision of Rectosigmoid Adenomas
Atkin, W. S., Morson, B. C., & Cuzick, J. (1992) · New England Journal of Medicine · doi:10.1056/nejm199203053261002 · Cited by 1,073
Winawer, S. J., Zauber, A. G., O'Brien, M. J., Ho, M. N., Gottlieb, L., Sternberg, S. S., Waye, J. D., Bond, J., Schapiro, M., Stewart, E. T., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304013281301 · Cited by 971
A Clinical Trial of Antioxidant Vitamins to Prevent Colorectal Adenoma
Greenberg, E. R., Baron, J. A., Tosteson, T. D., Freeman, D. H., Beck, G. J., Bond, J. H., Colacchio, T. A., Coller, J. A., Frankl, H. D., Haile, R. W., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199407213310301 · Cited by 762
Prevention of colorectal cancer by once-only sigmoidoscopy
Atkin, W. S., Northover, J. M. A., Cuzick, J., & Whynes, D. K. (1993) · The Lancet · doi:10.1016/0140-6736(93)90499-7 · Cited by 342
Practical Gastrointestinal Endoscopy: The Fundamentals
(2003) · Wiley eBooks · doi:10.1002/9780470987032 · Cited by 268
Endoscopic measurement of lesion size: Improved accuracy with image processing
Vakil, N. B., Smith, W. E., Bourgeois, K. A., Everbach, E. C., & Knyrim, K. (1994) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(94)70163-6 · Cited by 68
How reliable is determination of ulcer size by endoscopy?
Sonnenberg, A., Giger, M., Kern, L., Noll, C., Study, K. T., Weber, K., & Blum, A. L. (1979) · BMJ · doi:10.1136/bmj.2.6201.1322 · Cited by 67
Cited by
Polyp Miss Rate Determined by Tandem Colonoscopy: A Systematic Review
van Rijn, J. C., Reitsma, J. B., Stoker, J., Bossuyt, P. M., van Deventer, S. J., & Dekker, E. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00390.x · Cited by 1,344
Imperiale, T. F., Wagner, D. R., Lin, C. Y., Larkin, G. N., Rogge, J. D., & Ransohoff, D. F. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007203430302 · Cited by 1,060
Colonoscopic Screening of Average-Risk Women for Colorectal Neoplasia
Schoenfeld, P., Cash, B., Flood, A., Dobhan, R., Eastone, J., Coyle, W., Kikendall, J. W., Kim, H. M., Weiss, D. G., Emory, T., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042990 · Cited by 489
Lieberman, D., Moravec, M., Holub, J., Michaels, L., & Eisen, G. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.06.083 · Cited by 461
Results of Screening Colonoscopy among Persons 40 to 49 Years of Age
Imperiale, T. F., Wagner, D. R., Lin, C. Y., Larkin, G. N., Rogge, J. D., & Ransohoff, D. F. (2002) · New England Journal of Medicine · doi:10.1056/nejm200206063462304 · Cited by 317
Next-Generation Stool DNA Test Accurately Detects Colorectal Cancer and Large Adenomas
Ahlquist, D. A., Zou, H., Domanico, M., Mahoney, D. W., Yab, T. C., Taylor, W. R., Butz, M. L., Thibodeau, S. N., Rabeneck, L., Paszat, L. F., et al. (2012) · Gastroenterology · doi:10.1053/j.gastro.2011.10.031 · Cited by 315
Noshirwani, K. C., van Stolk, R. U., Rybicki, L. A., & Beck, G. J. (2000) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(00)70444-5 · Cited by 231
Atkin, W., Valori, R., Kuipers, E., Hoff, G., Senore, C., Segnan, N., Jover, R., Schmiegel, W., Lambert, R., & Pox, C. (2012) · Endoscopy · doi:10.1055/s-0032-1309821 · Cited by 221
Lieberman, D. A. (2008) · JAMA · doi:10.1001/jama.300.12.1417 · Cited by 210
“Estimates of polyp size at endoscopy could be subject to error, based on prior work.(21,22) It is possible that some individuals may have had prior screening examinations, which if negative, could bias the sample toward a lower rate of polyps sized more than 9 mm.”
Rutter, M. D., Chattree, A., Barbour, J. A., Thomas-Gibson, S., Bhandari, P., Saunders, B. P., Veitch, A. M., Anderson, J., Rembacken, B. J., Loughrey, M. B., et al. (2015) · Gut · doi:10.1136/gutjnl-2015-309576 · Cited by 206
Prevalence of advanced histological features in diminutive and small colon polyps
Gupta, N., Bansal, A., Rao, D., Early, D. S., Jonnalagadda, S., Wani, S. B., Edmundowicz, S. A., Sharma, P., & Rastogi, A. (2012) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2012.01.020 · Cited by 204
Pineau, B. C., Paskett, E. D., Chen, G. J., Espeland, M. A., Phillips, K., Han, J. P., Mikulaninec, C., & Vining, D. J. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00885-0 · Cited by 192
Predicting Advanced Proximal Colonic Neoplasia With Screening Sigmoidoscopy
Levin, T. R. (1999) · JAMA · doi:10.1001/jama.281.17.1611 · Cited by 186
“Polyp size was measured using the open biopsy forceps technique, a potentially inaccurate measurement.(27,28) However, distal adenoma size was unrelated to the prevalence of advanced proximal adenomas in multiple analyses (treating size as a continuous variable, excluding lesions smaller than 6 mm, or comparing lesion…”
MethodWide variation in adenoma detection rates at screening flexible sigmoidoscopy
Atkin, W., Rogers, P., Cardwell, C., Cook, C., Cuzick, J., Wardle, J., & Edwards, R. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.01.023 · Cited by 175
Metadata
- Authors
- Schoen, R. E., Gerber, L. D., & Margulies, C.
- Venue
- Gastrointestinal Endoscopy
- Publisher
- Elsevier BV
- Published
- 1997-12
- Volume
- 46
- Issue
- 6
- Pages
- 492-496
- ISSN
- 0016-5107 (ISSN-L)
- OpenAlex
- W2035395994
- Cited by
- 184
- References
- 8
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.