How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact.
Huberti, H. H., & Hayes, W. C. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00010 · Cited by 840 · cited 1×
“Orientation of the film on the tibial plateau was recorded by placing registration marks on the film in regions that supported only minimal load (Huberti and Hayes, 1984).”
Baratz, M. E., Fu, F. H., & Mengato, R. (1986) · The American Journal of Sports Medicine · doi:10.1177/036354658601400405 · Cited by 830
The strength of the anterior cruciate ligament in humans and Rhesus monkeys
Noyes, F., & Grood, E. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658080-00006 · Cited by 826 · cited 1×
“Therefore, using the modulus of 111726MPa (Noyes and Grood, 1976), the initial stiffness value for the transverse ligament was approximated to be 200 N/mm.”
Fukubayashi, T., & Kurosawa, H. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990887 · Cited by 813
Basic orthopaedic biomechanics
Mow, V. C., & Hayes, W. C. (1991) · Medical Entomology and Zoology · Cited by 655
Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci.
Kurosawa, H., Fukubayashi, T., & Nakajima, H. (1980) · PubMed · Cited by 528
Articular contact in a three-dimensional model of the knee
Blankevoort, L., Kuiper, J. H., Huiskes, R., & Grootenboer, H. J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90019-j · Cited by 520
Butler, D. L., Kay, M. D., & Stouffer, D. C. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90019-9 · Cited by 513 · cited 1×
“D nonlinear relationship was employed: where el is the nonlinear strain level parameter assumed to be 0.03 as in previous studies (Butler et al., 1986; Li et al., 1999; Pandy et al., 1997).”
InfluentialA Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
Haut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1470171 · Cited by 493 · cited 6×
“This digitizing system attempts to minimize the effects of dehydration of the exposed tissue (Haut et al., 1997).”
InfluentialSelf-citationLoad-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint with or Without Menisci
KUROSAWA, H., FUKUBAYASHI, T., & NAKAJIMA, H. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198006000-00039 · Cited by 469
Late degenerative changes after meniscectomy. Factors affecting the knee after operation
Allen, P., Denham, R., & Swan, A. (1984) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.66b5.6548755 · Cited by 468
Homologous meniscus transplantation: Experimental and clinical results
Milachowski, K. A., Weismeier, K., & Wirth, C. J. (1989) · International Orthopaedics · doi:10.1007/bf00266715 · Cited by 448 · cited 2×
“PII: S 0 0 2 1 - 9 2 9 0 ( 0 2 ) 0 0 3 0 5 - 6 1993; Milachowski et al., 1989).”
Injury and Repair of the Musculoskeletal Soft Tissues
Woo, S. L.-Y., Buckwalter, J. A., & Fung, Y. C. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168347 · Cited by 426
A three-dimensional mathematical model of the knee-joint
Wismans, J., Veldpaus, F., Janssen, J., Huson, A., & Struben, P. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90354-1 · Cited by 351 · cited 8×
“Gry ¼ Gzy ¼ 57:7MPa (range 27.7–77.7 MPa), 2. stiffness of transverse ligament=200 N/mm (1 spring) (range 50–900N/mm), 3. total stiffness of horn attachment=2000 N/mm (10 springs/horn 200 N/mm) (range 500–30,000 N/ mm), 4. nonlinear stiffness of medial collateral ligament bundles=2000 N (range 500–5000 N; from Blankev…”
InfluentialPaletta, G. A., Manning, T., Snell, E., Parker, R., & Bergfeld, J. (1997) · The American Journal of Sports Medicine · doi:10.1177/036354659702500519 · Cited by 339 · cited 3×
“Peak contact pressures on the lateral and medial articular surfaces of the tibia increase over 300% in the meniscectomized knee (Baratz et al., 1986; Kurosawa et al., 1980; Paletta et al., 1997; Seedhom and Hargreaves, 1979), and contact areas decrease by 50% (Baratz et al.”
Seedhom, B. B., & Hargreaves, D. J. (1979) · Engineering in Medicine · doi:10.1243/emed_jour_1979_008_051_02 · Cited by 334 · cited 1×
“Peak contact pressures on the lateral and medial articular surfaces of the tibia increase over 300% in the meniscectomized knee (Baratz et al., 1986; Kurosawa et al., 1980; Paletta et al., 1997; Seedhom and Hargreaves, 1979), and contact areas decrease by 50% (Baratz et al.”
Basic Orthopaedic Biomechanics
&NA; (1991) · Journal of Clinical Engineering · doi:10.1097/00004669-199111000-00020 · Cited by 307
Osteoarthritis After Arthroscopic Partial Meniscectomy
Rangger, C., Klestil, T., Gloetzer, W., Kemmler, G., & Benedetto, K. P. (1995) · The American Journal of Sports Medicine · doi:10.1177/036354659502300219 · Cited by 285 · cited 3×
“Nevertheless, some perspective can be gained by recognizing that a 5% difference in contact variables still represents a significant reduction from the changes in the contact variables seen for the meniscectomized knee (Allen et al., 1984; Baratz et al., 1986; Bolano and Grana, 1993; Kurosawa et al., 1980; Rangger et…”
A Validated Three-Dimensional Computational Model of a Human Knee Joint
Li, G., Gil, J., Kanamori, A., & Woo, S. L.-Y. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800871 · Cited by 264
Is it important to secure the horns during lateral meniscal transplantation? A cadaveric study
Chen, M., Branch, T. P., & Hutton, W. (1996) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(96)90007-9 · Cited by 254
Knee meniscus basic and clinical foundations
Bollen, S. (1993) · Current Orthopaedics · doi:10.1016/0268-0890(93)90031-l · Cited by 198
Seedhom, B. B. (1979) · Engineering in Medicine · doi:10.1243/emed_jour_1979_008_050_02 · Cited by 180
Arthroscopic partial meniscectomy: A long-term follow-up
Faunø, P., & Nielsen, A. B. (1992) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/0749-8063(92)90066-k · Cited by 175 · cited 1×
“In an effort to prevent degeneration of the articular cartilage caused by meniscectomies (Bolano and Grana, 1993; Fauno and Nielson, 1992; Rangger et al., 1995), both meniscal allografts (De Boer and Koudstaal, 1991; Siegel and Roberts, 1993; Stone, 1993;Veltri et al., 1994) and synthetic…”
Knee Meniscus: Basic and Clinical Foundations
Mow, V. C., ARNOCZKY, S. P., & Jackson, D. W. (1992) · Cited by 175
A Correlative Study of the Geometry and Anatomy of the Distal Femur
ELIAS, S. G., FREEMAN, M. A. R., & GOKCAY, E. I. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199011000-00018 · Cited by 173
Isolated arthroscopic partial meniscectomy: Functional radiographic evaluation at five years
Bolano, L., & Grana, W. A. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100318 · Cited by 172
Meniscal transplantation in the human knee: A preliminary report
Garrett, J. C., & Stevensen, R. N. (1991) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/0749-8063(91)90079-d · Cited by 167 · cited 1×
“However, the clinical success of meniscal allografts has been varied (Arnoczky et al., 1990; De Boer and Koudstaal, 1991; Garrett and Stevensen, 1991; Jackson et al., 1992; Kohn et al., 1992; Mikic et al., *Corresponding author.”
Meniscal replacement using a cryopreserved allograft. An experimental study in the dog.
ARNOCZKY, S. P., Warren, R. F., & McDevitt, C. A. (1990) · PubMed · Cited by 166
Donzelli, P. S., Spilker, R. L., Ateshian, G. A., & Mow, V. C. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00106-2 · Cited by 160
Ateshian, G. A., Kwak, S. D., Soslowsky, L. J., & Mow, V. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90038-8 · Cited by 149 · cited 3×
“, 1994), and shear artifact (Ateshian et al., 1994), care was taken to ensure that these sources of error were controlled during the experiment.”
Schaldach, M., & Furman, S. (1975) · Springer eBooks · doi:10.1007/978-3-642-66187-7 · Cited by 137
Meniscal Replacement Using a Cryopreserved Allograft
ARNOCZKY, S. P., Warren, R. F., & McDevitt, C. A. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199003000-00017 · Cited by 134 · cited 2×
“However, the clinical success of meniscal allografts has been varied (Arnoczky et al., 1990; De Boer and Koudstaal, 1991; Garrett and Stevensen, 1991; Jackson et al., 1992; Kohn et al., 1992; Mikic et al., *Corresponding author.”
A Three-Dimensional Musculoskeletal Model of the Human Knee Joint. Part 1: Theoretical Construction
Pandy, M. G., SASAKI, K., & KIM, S. (1997) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/01495739708936697 · Cited by 131
Injury and repair of the musculoskeletal soft tissues
Viidik, A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90253-9 · Cited by 101
A New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee Joint
Bach, J. M., & Hull, M. L. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2794195 · Cited by 67 · cited 1×
“The knee was then aligned in a specialized load application system for the testing of joints (Bach and Hull, 1995).”
Self-citationThe spatial and pressure resolution of fuji pressure-sensitive film
Liggins, A. B., Hardie, W. R., & Finlay, J. B. (1995) · Experimental Mechanics · doi:10.1007/bf02326476 · Cited by 58 · cited 1×
“To convert the intensity of the film stain to a pressure value, calibration curves were generated for both the super-low-range film, and the low-range film using a previously established procedure (Alhalki et al., 1999; Liggins et al., 1995; Liggins et al., 1992; Martens et al., 1997).”
MethodHaut, T. L., Hull, M. L., & Howell, S. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00049-9 · Cited by 35
Self-citationMorphometrical studies of human femoral condyles
Röstlund, T., Carlsson, L. V., Albrektsson, B., & Albrektsson, T. O. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90037-x · Cited by 34 · cited 1×
“Furthermore, the size and shape of both the femur and tibia vary between specimens as well (Elias et al., 1990; Kurosawa et al., 1980; Mensch and Amstutz, 1975; Reostlund et al., 1989).”
Cited by
Muscle and Joint Function in Human Locomotion
Pandy, M. G., & Andriacchi, T. P. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105259 · Cited by 325
Validation of computational models in biomechanics
Henninger, H. B., Reese, S. P., Anderson, A. E., & Weiss, J. A. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim649 · Cited by 204
Orsi, A. D., Canavan, P. K., Vaziri, A., Goebel, R., Kapasi, O. A., & Nayeb-Hashemi, H. (2017) · The Knee · doi:10.1016/j.knee.2017.02.010 · Cited by 41
Orsi, A. D., Chakravarthy, S., Canavan, P. K., Peña, E., Goebel, R., Vaziri, A., & Nayeb-Hashemi, H. (2016) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2015.1043626 · Cited by 24
“Bone was modeled as rigid, as it is much stiffer than the soft tissue it interacts with (Fung and Zhang 2003; Haut Donahue et al. 2003; Yang et al. 2010a; Homyk et al. 2012).”
Influential
Metadata
- Authors
- Haut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-01
- Volume
- 36
- Issue
- 1
- Pages
- 19-34
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2103051705
- Cited by
- 247
- References
- 38
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.