The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Abstract
The ability to determine trabecular bone tissue elastic and failure properties has biological and clinical importance. To date, trabecular tissue yield strains remain unknown due to experimental difficulties, and elastic moduli studies have reported controversial results. We hypothesized that the elastic and tensile and compressive yield properties of trabecular tissue are similar to those of cortical tissue. Effective tissue modulus and yield strains were calibrated for cadaveric human femoral neck specimens taken from 11 donors, using a combination of apparent-level mechanical testing and specimen-specific, high-resolution, nonlinear finite element modeling. The trabecular tissue properties were then compared to measured elastic modulus and tensile yield strain of human femoral diaphyseal cortical bone specimens obtained from a similar cohort of 34 donors. Cortical tissue properties were obtained by statistically eliminating the effects of vascular porosity. Results indicated that mean elastic modulus was 10% lower (p<0.05) for the trabecular tissue (18.0+/-2.8 GPa) than for the cortical tissue (19.9+/-1.8 GPa), and the 0.2% offset tensile yield strain was 15% lower for the trabecular tissue (0.62+/-0.04% vs. 0.73+/-0.05%, p<0.001). The tensile-compressive yield strength asymmetry for the trabecular tissue, 0.62 on average, was similar to values reported in the literature for cortical bone. We conclude that while the elastic modulus and yield strains for trabecular tissue are just slightly lower than those of cortical tissue, because of the cumulative effect of these differences, tissue strength is about 25% greater for cortical bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [142]
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Cowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263 · Cited by 1,456
Zysset, P. K., Guo, X.-D. E., Hoffler, C. E., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,001
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationAging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 534
Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 430
Self-citationSystematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100150115 · Cited by 377
Self-citationSilva, M. J., & Gibson, L. J. (1997) · Bone · doi:10.1016/s8756-3282(97)00100-2 · Cited by 355
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationHollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322
Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques
Ulrich, D., van Rietbergen, B., Weinans, H., & Ruegsegger, P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00118-3 · Cited by 280
A comparison of the fatigue behavior of human trabecular and cortical bone tissue
Choi, K., & Goldstein, S. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90051-2 · Cited by 247
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 226
Human vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 196
Hughes, T. J. R., Ferencz, R. M., & Hallquist, J. O. (1987) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(87)90005-3 · Cited by 184
The Accuracy of Digital Image-Based Finite Element Models
Guldberg, R. E., Hollister, S. J., & Charras, G. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798314 · Cited by 180
Ladd, A. J. C., Kinney, J. H., Haupt, D. L., & Goldstein, S. A. (1998) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100160516 · Cited by 171
Convergence Behavior of High-Resolution Finite Element Models of Trabecular Bone
Niebur, G. L., Yuen, J. C., Hsia, A. C., & Keaveny, T. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800865 · Cited by 165
Self-citationWhite, K. L., Murnaghan, J. H., & Gaus, C. R. (1972) · New England Journal of Medicine · doi:10.1056/nejm197212142872404 · Cited by 158
Biomechanical effects of intraspecimen variations in tissue modulus for trabecular bone
Jaasma, M. J., Bayraktar, H. H., Niebur, G. L., & Keaveny, T. M. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00193-2 · Cited by 126
Self-citationTrabecular bone's mechanical properties are affected by its non-uniform mineral distribution
van der Linden, J. C., Birkenhäger-Frenkel, D. H., Verhaar, J. A. N., et al. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00146-4 · Cited by 126
The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing.
Ulrich, D., Hildebrand, T., van Rietbergen, B., Müller, R., & Ruegsegger, P. (1997) · PubMed · Cited by 113
Micro-compression: a novel technique for the nondestructive assessment of local bone failure
Müller, R., Gerber, S. C., & Hayes, W. C. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-616 · Cited by 112
Yeh, O. C., & Keaveny, T. M. (1999) · Bone · doi:10.1016/s8756-3282(99)00092-7 · Cited by 112
Self-citationIs there a role for bone quality in fragility fractures?
Heaney, R. P. (1993) · Calcified Tissue International · doi:10.1007/bf01673394 · Cited by 90
Jacobs, C. R., Davis, B. R., Rieger, C. J., et al. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00115-3 · Cited by 72
Farè, S., Petrini, P., Motta, A., Cigada, A., & Tanzi, M. C. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199904)45:1 · Cited by 58
Beck, J. D., Canfield, B. L., Haddock, S. M., Chen, T. J., Kothari, M., & Keaveny, T. M. (1997) · Bone · doi:10.1016/s8756-3282(97)00122-1 · Cited by 58
Self-citationCowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263-14 · Cited by 40
Variation of Young’s Modulus and Hardness in Human Lumbar Vertebrae Measured by Nanoindentation
Roy, M. E., Rho, J. Y., Tsui, T. Y., et al. (1996) · Advances in Bioengineering · doi:10.1115/imece1996-1276 · Cited by 14
Cited by
Sorted by citations
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
Self-citationWoodard, J. R., Hilldore, A. J., Lan, S. K., Park, C. J., Whittington, A. R., Eurell, J. A. C., Clark, S. G., Wheeler, M. B., Jamison, R. D., & Johnson, A. J. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.021 · Cited by 829
“0 10–26 [37–43]”
BackgroundResultInfluentialBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez‐Viloria, M., Villa‐Camacho, J. C., Vaziri, A., & Nazarian, A. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 616
Mechanical basis of bone strength: influence of bone material, bone structure and muscle action.
Hart, N. H., Nimphius, S., Rantalainen, T., Ireland, A., Siafarikas, A., & Newton, R. U. (2017) · Europe PMC (PubMed Central) · Cited by 451
MacNeil, J. A., & Boyd, S. K. (2008) · Bone · doi:10.1016/j.bone.2008.01.017 · Cited by 440
“6 which is similar to values reported for cortical and trabecular bone [30,31].”
Metadata
- Authors
- Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of Notre Dame (US)
- Corresponding author
- Bayraktar, Harun H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 37
- Issue
- 1
- Pages
- 27-35
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2089968363
- Cited by
- 1,142
- References
- 36
- Citations by year
- 2026: 60 · 2025: 62 · 2024: 68 · 2023: 51 · 2022: 55 · 2021: 74 · 2020: 90 · 2019: 75 · 2018: 67 · 2017: 56 · 2016: 68 · 2015: 59 · 2014: 62 · 2013: 50 · 2012: 49
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- University of California, San Francisco
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784, AR41481)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- trabecular bone, cortical bone, femoral neck, elastic modulus, yield strain, tensile yield strength, compressive yield strength, finite element analysis
- MeSH terms
- Aged, Aged, 80 and over, Cadaver, Computer Simulation, Elasticity, Femur Head, Humans, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Stress, Mechanical, Tensile Strength, Reproducibility of Results, Weight-Bearing, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review