The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Abstract
The ability to determine trabecular bone tissue elastic and failure properties has biological and clinical importance. To date, trabecular tissue yield strains remain unknown due to experimental difficulties, and elastic moduli studies have reported controversial results. We hypothesized that the elastic and tensile and compressive yield properties of trabecular tissue are similar to those of cortical tissue. Effective tissue modulus and yield strains were calibrated for cadaveric human femoral neck specimens taken from 11 donors, using a combination of apparent-level mechanical testing and specimen-specific, high-resolution, nonlinear finite element modeling. The trabecular tissue properties were then compared to measured elastic modulus and tensile yield strain of human femoral diaphyseal cortical bone specimens obtained from a similar cohort of 34 donors. Cortical tissue properties were obtained by statistically eliminating the effects of vascular porosity. Results indicated that mean elastic modulus was 10% lower (p<0.05) for the trabecular tissue (18.0+/-2.8 GPa) than for the cortical tissue (19.9+/-1.8 GPa), and the 0.2% offset tensile yield strain was 15% lower for the trabecular tissue (0.62+/-0.04% vs. 0.73+/-0.05%, p<0.001). The tensile-compressive yield strength asymmetry for the trabecular tissue, 0.62 on average, was similar to values reported in the literature for cortical bone. We conclude that while the elastic modulus and yield strains for trabecular tissue are just slightly lower than those of cortical tissue, because of the cumulative effect of these differences, tissue strength is about 25% greater for cortical bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [142]
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Cowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263 · Cited by 1,456
Zysset, P. K., Guo, X.-D. E., Hoffler, C. E., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,001
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationAging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Cited by
Sorted by citations
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
Self-citationWoodard, J. R., Hilldore, A. J., Lan, S. K., Park, C. J., Whittington, A. R., Eurell, J. A. C., Clark, S. G., Wheeler, M. B., Jamison, R. D., & Johnson, A. J. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.021 · Cited by 829
“0 10–26 [37–43]”
BackgroundResultInfluentialBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez‐Viloria, M., Villa‐Camacho, J. C., Vaziri, A., & Nazarian, A. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 616
Mechanical basis of bone strength: influence of bone material, bone structure and muscle action.
Hart, N. H., Nimphius, S., Rantalainen, T., Ireland, A., Siafarikas, A., & Newton, R. U. (2017) · Europe PMC (PubMed Central) · Cited by 451
MacNeil, J. A., & Boyd, S. K. (2008) · Bone · doi:10.1016/j.bone.2008.01.017 · Cited by 440
“6 which is similar to values reported for cortical and trabecular bone [30,31].”
Prediction of strength and strain of the proximal femur by a CT-based finite element method
Bessho, M., Ohnishi, I., Matsuyama, J., Matsumoto, T., Imai, K., & Nakamura, K. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.08.003 · Cited by 408
“To allow for the nonlinear phase, the mechanical properties of the elements were assumed to be bi-linear elastoplastic, and the post-yield modulus was set as 5% of E (where E is the pre-yield Young’s modulus) (Bayraktar et al., 2004; Reilly and Burstein, 1975).”
BackgroundExtracellular Matrix Alterations in Metastatic Processes
Paolillo, M., & Schinelli, S. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20194947 · Cited by 392
“Cortical bone is formed by densely packed collagen type I fibrils and is highly mineralized to strengthen the bone structure thus providing a steady support for the skeleton [96], while trabecular bone is a porous matrix organized in a broader structural network [97].”
BackgroundSchileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 375
“…(Nalla et al., 2003; Taylor, 2003), there is a growing consensus on the substantial isotropy of yield strain and on its invariance to density (Bayraktar et al., 2004b; Chang et al., 1999; Cowin and He, 2005; Currey, 2004; Kopperdahl and Keaveny, 1998), and a strain-based criteria managed to…”
BackgroundMethodInfluentialSubject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 332
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
“This is in line with earlier findings [28,97,20,119,3,24,39,118].”
ResultHip Fractures and the Contribution of Cortical Versus Trabecular Bone to Femoral Neck Strength
Holzer, G., von Skrbensky, G., Holzer, L. A., & Pichl, W. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081108 · Cited by 319
The use of digital image correlation in the biomechanical area: a review
Palanca, M., Tozzi, G., & Cristofolini, L. (2015) · International Biomechanics · doi:10.1080/23335432.2015.1117395 · Cited by 306
“For instance, the stiffness is computed as the ratio between the load and the displacement; bone remodelling is a well-known stress/ strain-driven process (Wolff’s law); bone fracture is governed by a strain-based failure criterion (Bayraktar et al. 2004).”
BackgroundMontazerian, H., Davoodi, E., Asadi‐Eydivand, M., Kadkhodapour, J., & Solati‐Hashjin, M. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.04.009 · Cited by 286
Zhang, X.-Y., Fang, G., Leeflang, M. A., ZADPOOR, A. A., & Zhou, J. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.12.013 · Cited by 280
Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
ORWOLL, E. S., Marshall, L. M., Nielson, C. M., Cummings, S. R., Lapidus, J., Cauley, J. A., Ensrud, K. E., Lane, N. E., Hoffmann, P. R., Kopperdahl, D. L., et al. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081201 · Cited by 266
Self-citationYoung’s modulus of trabecular bone at the tissue level: A review
Wu, D., Isaksson, P., Ferguson, S. J., & Persson, C. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.001 · Cited by 265
Adult Stem Cells for Bone Regeneration and Repair
Iaquinta, M. R., Mazzoni, E., Bononi, I., Rotondo, J. C., Mazziotta, C., Montesi, M., Sprio, S., Tampieri, A., Tognon, M. G., & Martini, F. (2019) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2019.00268 · Cited by 271
Management and Prevention of Bone Stress Injuries in Long-Distance Runners
Warden, S. J., Davis, I. S., & Fredericson, M. (2014) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2014.5334 · Cited by 277
Dragomir‐Daescu, D., den Buijs, J. O., McEligot, S., Dai, Y., Entwistle, R. C., Salas, C., Melton, L. J., Bennet, K. E., Khosla, S., & Amin, S. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0196-y · Cited by 232
“Before potential clinical implementation, however, the robustness and convergence of such models must be determined with respect to ( 1 ) meshing technique and element size, (2) bone tissue segmentation from the CT scans, and (3) assignment of material properties .I n addition, the models need to be validated by compa…”
InfluentialLimmahakhun, S., Oloyede, A., Sitthiseripratip, K., Xiao, Y., & Yan, C. (2016) · Materials & Design · doi:10.1016/j.matdes.2016.11.090 · Cited by 229
Trabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220
“6MPa (Bayraktar et al., 2004).”
Keaveny, T. M., Hoffmann, P., Singh, M., Palermo, L., Bilezikian, J. P., Greenspan, S. L., & Black, D. M. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080805 · Cited by 218
Self-citationTissue mimicking materials for imaging and therapy phantoms: a review
McGarry, C. K., Grattan, L. J., Ivory, A. M., et al. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abbd17 · Cited by 216
Ahmadi, S. M., Hedayati, R., Li, Y., Lietaert, K., Tümer, N., Fatemi, A., Rans, C. D., Pouran, B., Weinans, H., & ZADPOOR, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.014 · Cited by 210
Dumas, M., Terriault, P., & Braïlovski, V. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.02.021 · Cited by 207
Compressive behaviour of child and adult cortical bone
Öhman‐Mägi, C., Baleani, M., Pani, C., Taddei, F., Alberghini, M., Viceconti, M., & Manfrini, M. (2011) · Bone · doi:10.1016/j.bone.2011.06.035 · Cited by 183
“2%) reported [37] or estimated [20] from the literature.”
BackgroundDall’Ara, E., Luisier, B., Schmidt, R., Kainberger, F. M., Zysset, P. K., & Pahr, D. H. (2012) · Bone · doi:10.1016/j.bone.2012.09.006 · Cited by 176
“Therefore, a nonlinear scalar function (tissue function TF, Appendix A) for both compression and tension was defined to provide, once extrapolated for poreless bone (BV/TV=ρ=1), an elastic modulus equal to 24 GPa (Emax), a compression ultimate stress equal to 266 MPa and a tension ultimate stress equal to 200 MPa.”
BackgroundMethodLoad distribution in the healthy and osteoporotic human proximal femur during a fall to the side
Verhulp, E. E., van Rietbergen, B., & Huiskes, R. (2007) · Bone · doi:10.1016/j.bone.2007.08.039 · Cited by 174
“The yield strains of cortical bone in tension and compression were taken as 0.73% and �1.12%, respectively [ 14 ].”
BackgroundInfluentialOnal, E., Frith, J. E., Jurg, M., Wu, X., & Molotnikov, A. (2018) · Metals · doi:10.3390/met8040200 · Cited by 173
“, Ti6Al4V and 316 L stainless steel have a modulus of around 110 GPa and 210 GPa [4] respectively, whereas the modulus of cortical bone is in the range of 3–20 GPa [5].”
BackgroundGleadall, A., Visscher, D. O., Yang, J., et al. (2018) · Burns & Trauma · doi:10.1186/s41038-018-0121-4 · Cited by 172
“3 to 20 MPa for cartilage [40, 41], 100 to 500 MPa for cancellous bone [42], and 12,000 to 20,000 MPa for cortical bone [42, 43].”
BackgroundAge-dependence of femoral strength in white women and men
Keaveny, T. M., Kopperdahl, D. L., Melton, L. J., Hoffmann, P., Amin, S., Riggs, B. L., & Khosla, S. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091033 · Cited by 171
Self-citationZohar Yosibash, A., Trabelsi, N., & Milgrom, C. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.06.017 · Cited by 170
“In Alho et al. (1988), Esses et al. (1989), Heismann et al. (2003), Bayraktar et al. (2004) the trabecular bone is associated with HUo2002500 and r app o0:7520:97 g=cm 3 .”
BackgroundChevalier, Y., Pahr, D. H., Allmer, H., Charlebois, M., & Zysset, P. K. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.004 · Cited by 169
Recent advancements in Fe-based biodegradable materials for bone repair
Gorejová, R., Haverová, L., Oriňáková, R., Oriňák, A., & Oriňak, M. (2018) · Journal of Materials Science · doi:10.1007/s10853-018-3011-z · Cited by 167
Zhang, X., Yan, X., Fang, G., et al. (2019) · Additive manufacturing · doi:10.1016/j.addma.2019.101015 · Cited by 157
Kiani, F., Wen, C., & Li, Y. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.12.023 · Cited by 156
Cordell, J. M., Vogl, M. L., & Johnson, A. J. W. (2009) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2009.01.009 · Cited by 155
Surmeneva, M. A., Анатольевич, С. Р., Chudinova, E., Koptioug, A., Tkachev, M. S., Gorodzha, S. N., & Rännar, L. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.07.059 · Cited by 155
Implant positioning in reverse shoulder arthroplasty has an impact on acromial stresses
Wong, M. T., Langohr, G. D. G., Athwal, G. S., et al. (2016) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2016.04.011 · Cited by 153
Schileo, E., Balistreri, L., Grassi, L., Cristofolini, L., & Taddei, F. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.024 · Cited by 151
Finite Element Analysis of Fracture Fixation
Lewis, G. S., Mischler, D., Wee, H., Reid, J. S., & Varga, P. (2021) · Current Osteoporosis Reports · doi:10.1007/s11914-021-00690-y · Cited by 152
Bevill, G. R., Eswaran, S. K., Gupta, A. K., Papadopoulos, P., & Keaveny, T. M. (2006) · Bone · doi:10.1016/j.bone.2006.06.016 · Cited by 148
“81%) were calibrated for 12 of the femoral neck specimens following an iterative algorithm [29].”
MethodSelf-citationRazfar, N., Reeves, J. M., Langohr, G. D. G., Willing, R. T., Athwal, G. S., & Johnson, J. A. (2016) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2015.11.011 · Cited by 149
Bessho, M., Ohnishi, I., Matsumoto, T., et al. (2009) · Bone · doi:10.1016/j.bone.2009.04.241 · Cited by 148
“Young's modulus of each triangular shell element was set as equivalent to that of the adjacent tetrahedral element located underneath the shell element, while the minimum Young's modulus of the shell element was set as 10 GPa.”
Öhman‐Mägi, C., Dall’Ara, E., Baleani, M., Jan, S. V. S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.07.007 · Cited by 145
Karre, R., Niranjan, M. K., & Dey, S. R. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.01.061 · Cited by 145
Mechanisms governing the inelastic deformation of cortical bone and application to trabecular bone
Mercer, C., He, M. Y., Wang, R., et al. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.08.004 · Cited by 145
Abdelwahab, A. A., Maligno, A. R., & Silberschmidt, V. V. (2011) · Computational Materials Science · doi:10.1016/j.commatsci.2011.01.021 · Cited by 144
Biomechanical Computed Tomography analysis (BCT) for clinical assessment of osteoporosis
Keaveny, T. M., Clarke, B. L., Cosman, F., ORWOLL, E. S., Siris, E. S., Khosla, S., & Bouxsein, M. (2020) · Osteoporosis International · doi:10.1007/s00198-020-05384-2 · Cited by 148
Self-citationBiomechanics of Femoral Neck Fractures and Implications for Fixation
Augat, P., Bliven, E. K., & Hackl, S. (2018) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000001365 · Cited by 142
Trabecular plates and rods determine elastic modulus and yield strength of human trabecular bone
Wang, J., Zhou, B., Liu, X. S., Fields, A. J., Sanyal, A., Shi, X., Adams, M. F., Keaveny, T. M., & Guo, X.-D. E. (2014) · Bone · doi:10.1016/j.bone.2014.11.006 · Cited by 139
“81% of strain in tension and compression [24].”
Self-citationBiological basis of bone strength: anatomy, physiology and measurement.
Hart, N. H., Newton, R. U., Tan, J., Rantalainen, T., Chivers, P., Siafarikas, A., & Nimphius, S. (2020) · PubMed Central · Cited by 137
Influence of boundary conditions on computed apparent elastic properties of cancellous bone
Pahr, D. H., & Zysset, P. K. (2007) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-007-0109-7 · Cited by 136
“The most accurate, but also computationally most expensive models, are digital finite element models (Hollister and Kikuchi 1994; Van Rietbergen et al. 1996; Niebur et al. 2000; Bayraktar et al. 2004 ).”
BackgroundAdams, M. F., Bayraktar, H. H., Keaveny, T. M., & Papadopoulos, P. (2005) · ACM/IEEE Conference on Supercomputing (SC) · doi:10.1109/sc.2004.62 · Cited by 136
“The biomechanics component of our research primarily involves nonlinear micro-FE analyses [31, 29, 10, 9], for which an inexact Newton method is used.”
BackgroundMethodSelf-citationCarbon plasma immersion ion implantation of nickel–titanium shape memory alloys
Poon, R. W. Y., Yeung, K., Liu, X. Y., et al. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.056 · Cited by 134
“Moreover, its elastic modulus [1] is closer to that of cortical bones [2] as compared to that of other implantable materials such as stainless steels [1,3] and titanium alloys [3,4].”
BackgroundHedayati, R., Sadighi, M., Aghdam, M. M., et al. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.11.001 · Cited by 132
Koivumäki, J., Thevenot, J., Pulkkinen, P., Kühn, V., Link, T. M., Eckstein, F., & Jämsä, T. J. (2012) · Bone · doi:10.1016/j.bone.2012.01.012 · Cited by 131
Micro-CT finite element model and experimental validation of trabecular bone damage and fracture
Hambli, R. (2013) · Bone · doi:10.1016/j.bone.2013.06.028 · Cited by 129
“Nevertheless, cohesive FE methods are restricted to the problem of idealized planar cracks with a cohesive zone [10] and these methods are based on a limited number of simple uncoupled crack initiation criteria (principal stress or strain) which are unable to describe complex bone damage and fracture behavior or to di…”
BackgroundMethodPoint-of-care antimicrobial coating protects orthopaedic implants from bacterial challenge
Xi, W., Hegde, V. V., Zoller, S. D., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25383-z · Cited by 128
Trabecular scaffolds created using micro CT guided fused deposition modeling
Tellis, B. C., Szivek, J. A., Bliss, C. L., et al. (2007) · Materials Science and Engineering C · doi:10.1016/j.msec.2006.11.010 · Cited by 125
Standardizing compression testing for measuring the stiffness of human bone
Zhao, S., Arnold, M. C. A., Ma, S., Abel, R., Cobb, J. P., Hansen, U., & Boughton, O. R. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.78.bjr-2018-0025.r1 · Cited by 122
Thurner, P. J., Erickson, B. W., Jungmann, R., Schriock, Z., Weaver, J. C., Fantner, G. E., Schitter, G., Morse, D. E., & Hansma, P. K. (2006) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2006.05.024 · Cited by 121
“Mechanical testing of trabecular bone is a vast experimental field [3,6,11–14,31].”
BackgroundLee, D. C., Hoffmann, P. F., Kopperdahl, D. L., & Keaveny, T. M. (2017) · Bone · doi:10.1016/j.bone.2017.07.029 · Cited by 124
Self-citationResorbable bone fixation alloys, forming, and post-fabrication treatments
Ibrahim, H., Esfahani, S. N., Poorganji, B., Dean, D., & Elahinia, M. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.09.069 · Cited by 118
“It is desirable that the maximum Von Mises (VM) stress of cortical bone is lower than its maximum yield strength (108 MPa) for sufficient fixation hardware biomechanical stability [78, 79].”
BackgroundKeaveny, T. M., McClung, M. R., Genant, H. K., Zanchetta, J., Kendler, D. L., Brown, J. P., Goemaere, S., Recknor, C. P., Brandi, M. L., Eastell, R., et al. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2024 · Cited by 117
Self-citationBartolomeu, F., Costa, M. M., Alves, N. M., et al. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106208 · Cited by 116
Plant Tissues as 3D Natural Scaffolds for Adipose, Bone and Tendon Tissue Regeneration
Negrini, N. C., Toffoletto, N., Farè, S., & Altomare, L. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00723 · Cited by 119
A novel design, analysis and 3D printing of Ti-6Al-4V alloy bio-inspired porous femoral stem
Mehboob, H., Tarlochan, F., Mehboob, A., et al. (2020) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-020-06420-7 · Cited by 114
Mechanisms of uniformity of yield strains for trabecular bone
Bayraktar, H. H., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.045 · Cited by 112
“Recently these models have also been used to obtain values of tissue-level yield strains for human trabecular bone using a combined experimental–computational protocol (Bayraktar et al., 2004).”
BackgroundMethodResultInfluentialSelf-citationSansalone, V., Naili, S., Bousson, V., Bergot, C., Peyrin, F., Zarka, J., Laredo, J. D., & Haïat, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.034 · Cited by 109
“However, a critical issue consists in the anisotropy and heterogeneity (the assumption of isotropy and homogeneity has often been made (Bayraktar et al., 2004; Chevalier et al., 2007; Haı̈at et al., 2009a, 2009b)) of the bone material properties.”
BackgroundA Biomechanical Analysis of the Effects of Resorption Cavities on Cancellous Bone Strength
Hernandez, C. J., Gupta, A. K., & Keaveny, T. M. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060514 · Cited by 111
Self-citationQasim, M., Farinella, G., Ju, Z., Li, X., Yang, L., Eastell, R., & Viceconti, M. (2016) · Osteoporosis International · doi:10.1007/s00198-016-3597-4 · Cited by 110
Association of hip strength estimates by finite-element analysis with fractures in women and men
Amin, S., Kopperdhal, D. L., Melton, L. J., Achenbach, S. J., Therneau, T. M., Riggs, B. L., Keaveny, T. M., & Khosla, S. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.347 · Cited by 111
Self-citationAdvanced CT based In Vivo Methods for the Assessment of Bone Density, Structure, and Strength
Engelke, K., Libanati, C. R., Fuerst, T. P., et al. (2013) · Current Osteoporosis Reports · doi:10.1007/s11914-013-0147-2 · Cited by 107
Xiong, Y., Wang, W., Gao, R.-N., et al. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.108994 · Cited by 107
Analysis of fracture processes in cortical bone tissue
Li, S., Abdelwahab, A. A., & Silberschmidt, V. V. (2012) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2012.11.020 · Cited by 106
“6% [22, 23] in this case.”
Comparison of non-invasive assessments of strength of the proximal femur
Jóhannesdóttir, F., Thrall, E., Muller, J. A., Keaveny, T. M., Kopperdahl, D. L., & Bouxsein, M. (2017) · Bone · doi:10.1016/j.bone.2017.07.023 · Cited by 105
Self-citationFalcinelli, C., Schileo, E., Balistreri, L., Baruffaldi, F., Bordini, B., Viceconti, M., Albisinni, U., Ceccarelli, F., Milandri, L., Toni, A., et al. (2014) · Bone · doi:10.1016/j.bone.2014.06.038 · Cited by 104
“04% compressive) in the ROI external surface [28].”
BackgroundDall’Ara, E., Fernández, M. P., Palanca, M., et al. (2017) · Frontiers in Materials · doi:10.3389/fmats.2017.00031 · Cited by 102
“This would be feasible, for example, when strain measurements are used to classify between bone strained below or above yield [7,000–10,000με (Bayraktar et al., 2004)].”
BackgroundVarga, P., Hesse, B., Langer, M., Schrof, S., Männicke, N., Suhonen, H., Pacureanu, A., Pahr, D. H., Peyrin, F., & Raum, K. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0601-9 · Cited by 101
A comparison of cortical and trabecular bone from C57 Black 6 mice using Raman spectroscopy
Goodyear, S. R., Gibson, I. R., Skakle, J. M. S., Wells, R. P. K., & Aspden, R. M. (2009) · Bone · doi:10.1016/j.bone.2009.01.008 · Cited by 99
“The elastic properties of both bone types have been measured using nanoindentation [15,16], acoustic microscopy [17] or both [18], or back-calculated by comparing experimental results with finite element predictions [19].”
MethodVerhulp, E. E., van Rietbergen, B., Müller, R., & Huiskes, R. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.032 · Cited by 99
“A tissue Young’s modulus of 20GPa, as suggested by several recent studies (Niebur et al., 2000; Bayraktar et al., 2004), would have resulted in yield strains that are about a factor 3 less than reported here and bring it in the same range as reported in these earlier studies.”
BackgroundMethodResultInfluentialChen, Y., Dall’Ara, E., Sales, E., Manda, K., Wallace, R. J., Pankaj, P., & Viceconti, M. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.09.014 · Cited by 99
The Modified Super-Ellipsoid Yield Criterion for Human Trabecular Bone
Bayraktar, H. H., Gupta, A. K., Kwon, R. Y., Papadopoulos, P., & Keaveny, T. M. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1763177 · Cited by 99
“83%) were assigned to all specimens [24].”
MethodInfluentialSelf-citationMicrostructural Failure Mechanisms in the Human Proximal Femur for Sideways Fall Loading
Nawathe, S., Akhlaghpour, H., Bouxsein, M., et al. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2033 · Cited by 98
Self-citationWolfram, U., Wilke, H., & Zysset, P. K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.02.026 · Cited by 95
Chen, T. L., Wong, D. W., Wang, Y. S., et al. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.12.007 · Cited by 95
Dopico-González, C., New, A., & Browne, M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.039 · Cited by 95
“…and hence it was neglected for the present study; some studies have suggested the use of strainbased failure criteria as fracture predictors (Wong et al., 2001; Kopperdahl, 1999; Schileo et al., 2007; Morgan and Keaveny, 2001; Bayraktar et al., 2004), similar to that adopted in the present work.”
ResultGraphene oxide as a scaffold for bone regeneration
Holt, B. D., Wright, Z. M., Arnold, A. M., & Sydlik, S. A. (2016) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1437 · Cited by 94
“It is estimated that cortical bone is up to 25% stronger than less dense, more porous cancellous bone.(22) Seemingly, the mineral component of bone provides stiffness while the more compliant collagen assemblies give bone viscoelasticity(23) and improves its toughness.”
BackgroundA survey of micro-finite element analysis for clinical assessment of bone strength: The first decade
van Rietbergen, B., & Ito, K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.024 · Cited by 94
Mechanics of additively manufactured porous biomaterials based on the rhombicuboctahedron unit cell
Hedayati, R., Sadighi, M., Aghdam, M. M., et al. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.07.013 · Cited by 94
Palanca, M., Tozzi, G., Cristofolini, L., et al. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4030174 · Cited by 92
“Such an error is one order of magnitude lower than the failure strain of bone tissue (7000 microstrain in tension, 10000 microstrain in compression, [26]).”
BackgroundMicro finite element analysis of dental implants under different loading conditions
Marcián, P., Wolff, J., Horáčková, L., et al. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.03.012 · Cited by 91
Hedayati, R., Sadighi, M., Aghdam, M. M., et al. (2015) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2015.11.033 · Cited by 90
Post-yield and failure properties of cortical bone
Wolfram, U., & Schwiedrzik, J. J. (2016) · BoneKEy Reports · doi:10.1038/bonekey.2016.60 · Cited by 95
“Repetitive loading experiments11 showed that a previous compressive overload deteriorates the tensile elastic and post-elastic properties, Table 1 Macroscopic strength values for human cortical bone Source d n Age Range in years Test condition Test direction Loading mode ey in % sy in MPa eu in % su in MPa Post-yield…”
InfluentialMulti-scale modelling of elastic moduli of trabecular bone
Hamed, E., Jasiuk, I., Yoo, A. C., Lee, Y., & Liszka, T. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0814 · Cited by 90
Liu, X. S., Bevill, G. R., Keaveny, T. M., Sajda, P., & Guo, X.-D. E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.035 · Cited by 89
“…in computational simulations on a whole vertebral body that vertical trabeculae generally carry most of the load compared to the transverse ones (Bayraktar et al., 2004a; Homminga et al., 2004), and quantitatively confirmed by a recent study that the axially aligned trabeculae play an essential…”
BackgroundMethodInfluentialSelf-citationFemoral shaft strains during daily activities: Implications for atypical femoral fractures
Martelli, S., Pivonka, P., & Ebeling, P. R. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.08.001 · Cited by 88
“Therefore, the combination of tensile loads, to which bone is most susceptible (Bayraktar et al., 2004), and increased bone fragility that may be associated with long-term anti-resorptive therapy (Shane et al., 2013) may be an important co-factor in creating a favorable environment for AFFs.”
BackgroundEvaluation of macrostructural bone biomechanics
Beaupied, H., Lespessailles, É., & Benhamou, C.-L. (2007) · Joint Bone Spine · doi:10.1016/j.jbspin.2007.01.019 · Cited by 93
Anisotropic mode-dependent damage of cortical bone using the extended finite element method (XFEM)
Feerick, E. M., Liu, X., & McGarry, P. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.12.004 · Cited by 86
“Additionally, the present study implements alternate strengths in tension and compression, as motivated by previous experimental results for cortical bone (Bayraktar et al., 2004; Mercer et al., 2006).”
Result
Metadata
- Authors
- Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of Notre Dame (US)
- Corresponding author
- Bayraktar, Harun H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 37
- Issue
- 1
- Pages
- 27-35
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2089968363
- Cited by
- 1,142
- References
- 36
- Citations by year
- 2026: 60 · 2025: 62 · 2024: 68 · 2023: 51 · 2022: 55 · 2021: 74 · 2020: 90 · 2019: 75 · 2018: 67 · 2017: 56 · 2016: 68 · 2015: 59 · 2014: 62 · 2013: 50 · 2012: 49
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- University of California, San Francisco
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784, AR41481)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- trabecular bone, cortical bone, femoral neck, elastic modulus, yield strain, tensile yield strength, compressive yield strength, finite element analysis
- MeSH terms
- Aged, Aged, 80 and over, Cadaver, Computer Simulation, Elasticity, Femur Head, Humans, Male, Middle Aged, Models, Biological, Sensitivity and Specificity, Statistics as Topic, Stress, Mechanical, Tensile Strength, Reproducibility of Results, Weight-Bearing, Compressive Strength, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›