Fabric and elastic principal directions of cancellous bone are closely related

Open access
Odgaard, Anders, Kabel, Jesper, van Rietbergen, Bert, Dalstra, Michel, Huiskes, Rik · 1997 · Journal of Biomechanics

Abstract

Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much effort has been spent in expressing these relations, but the techniques and variables necessary for this have not been fully identified. It is obvious, however, that some measure of architectural anisotropy (fabric) is needed. Within the last few years, volume-based measures of fabric have been introduced as alternatives to the mean intercept length method, which has some theoretical problems. This paper seeks to answer which of four different fabric measures best predicts finite element calculated mechanical anisotropy directions. Twenty-nine cancellous bone specimens were three-dimensionally reconstructed using the automated serial sectioning technique. A series of large-scale finite-element analyses were performed on each of the three-dimensional reconstructions to calculate the compliance matrix for each specimen, from which the mechanical principal directions were derived. The architectural anisotropy was determined in three-dimensional space for each specimen using mean intercept length (MIL), volume orientation (VO), star volume distribution (SVD) and star length distribution (SLD). Each of the architectural anisotropy results were expressed by a fabric tensor. Architectural main directions were determined from the fabric tensors and compared with the FE-calculated mechanical anisotropy directions. All architectural measures predicted the mechanical main directions rather well, which supports the assumption that mechanical anisotropy directions are aligned with fabric directions. MIL showed a significant, though very small (1.4 degrees), deviation from the primary mechanical direction. VO had difficulty in determining secondary and tertiary mechanical directions; its mean deviation was 8.9 degrees. SVD and SLD provided marginally better predictors of mechanical anisotropy directions than MIL and VO.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9290(96)00177-7

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Research works printed but not linked: 6

  1. Goulet, 1988, The effects of architecture and morphology on the mechanical properties of trabecular bone, Trans. Orthop. Res. Soc., 13, 73
  2. Goulet, 1992, Quantification of the architecture of cancellous bone by surface and volume orientation methods, Trans. Orthop. Res. Soc., 17, 159
  3. Goulet, 1996, Determination of minimum microstructural analysis volumes for trabecular bone using 3-D stereology and FFT analysis, Trans. Orthop. Res. Soc., 21, 715
  4. Jacobs, 1993, A comparative study of automatic finite element mesh generation techniques in orthopaedic biomechanics, ASME/BED, 24, 512
  5. van Rietbergen, 1996, Fabric and density accurately predict the elastic properties of trabecular bone architecture, J. orthop. Res.
  6. Whitehouse, 1981, Irregularities and asymmetrics in trabecular bone in the innominate and elsewhere, Metab. Bone Dis. Rel. Res., S2, 271

Cited by

See all 377

Metadata

Authors
Odgaard, A., Kabel, J., van Rietbergen, B., Dalstra, M., & Huiskes, R.
Affiliations
  • Aarhus University Hospital (DK)
  • Radboud University Nijmegen (NL)
Corresponding author
Odgaard, Anders
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
1997-05
Volume
30
Issue
5
Pages
487-495
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2042695653
Cited by
338
References
32
Citations by year
2026: 10 · 2025: 3 · 2024: 6 · 2023: 5 · 2022: 4 · 2021: 9 · 2020: 10 · 2019: 5 · 2018: 31 · 2017: 16 · 2016: 11 · 2015: 9 · 2014: 22 · 2013: 14 · 2012: 14
FWCI
9.39
Type
journal article
Language
en
Open access
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Biomechanics (publishedVersion)
  • PubMed (publishedVersion)
  • TU/e Research Portal (publishedVersion, other-oa)
  • TU/e Research Portal (submittedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
  • Radboud Repository (Radboud University) (submittedVersion, other-oa)
  • TU/e Research Portal (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
Keywords
trabecular bone, trabecular bone microarchitecture, fabric tensor, mean intercept length, compliance matrix, finite element analysis, 3D reconstruction, Wolff's law, bone mechanics
MeSH terms
Animals, Biomechanical Phenomena, Bone and Bones, Elasticity, Image Processing, Computer-Assisted, Models, Biological, Whales, Anisotropy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fabric and elastic principal directions of cancellous bone are closely related. https://app.cochat.ai/papers/10.1016/s0021-9290(96)00177-7
The paper
Odgaard, A., Kabel, J., van Rietbergen, B., Dalstra, M., & Huiskes, R. (1997). Fabric and elastic principal directions of cancellous bone are closely related. Journal of Biomechanics. https://doi.org/10.1016/s0021-9290(96)00177-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.