Fabric and elastic principal directions of cancellous bone are closely related
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much effort has been spent in expressing these relations, but the techniques and variables necessary for this have not been fully identified. It is obvious, however, that some measure of architectural anisotropy (fabric) is needed. Within the last few years, volume-based measures of fabric have been introduced as alternatives to the mean intercept length method, which has some theoretical problems. This paper seeks to answer which of four different fabric measures best predicts finite element calculated mechanical anisotropy directions. Twenty-nine cancellous bone specimens were three-dimensionally reconstructed using the automated serial sectioning technique. A series of large-scale finite-element analyses were performed on each of the three-dimensional reconstructions to calculate the compliance matrix for each specimen, from which the mechanical principal directions were derived. The architectural anisotropy was determined in three-dimensional space for each specimen using mean intercept length (MIL), volume orientation (VO), star volume distribution (SVD) and star length distribution (SLD). Each of the architectural anisotropy results were expressed by a fabric tensor. Architectural main directions were determined from the fabric tensors and compared with the FE-calculated mechanical anisotropy directions. All architectural measures predicted the mechanical main directions rather well, which supports the assumption that mechanical anisotropy directions are aligned with fabric directions. MIL showed a significant, though very small (1.4 degrees), deviation from the primary mechanical direction. VO had difficulty in determining secondary and tertiary mechanical directions; its mean deviation was 8.9 degrees. SVD and SLD provided marginally better predictors of mechanical anisotropy directions than MIL and VO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Trabecular bone often exhibits orthotropic symmetry (94, 95), although in some cases, such as in the vertebrae, transverse isotropy has been reported (93).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [93]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Indeed, the principal directions of the mechanical anisotropy of trabecular bone are very closely aligned with the principal directions (eigenvectors) of the fabric tensor (93).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [93]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaling: Why is Animal Size so Important?
Schmidt-Nielsen, K. (1984) · doi:10.1017/cbo9781139167826 · Cited by 2,677
Scaling Why is animal size so important?
Schmidt‐Nielsen, K. (1984) · Cited by 2,654
Statistics of Directional Data.
Gokhale, D. V., & Mardia, K. V. (1973) · Biometrics · doi:10.2307/2529189 · Cited by 2,442 · cited 1×
“In parametric distribution models, the orientation matrix also plays an important role in statistical inference (Fisher et al., 1987: Mardia, 1972; Woodcock, 1977), and the orientation matrix is the first element in the fabric tensor expansion described by Kanatani (1984).”
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865 · cited 1×
“The reason for the spread around secondary and tertiary directions is probably relatively transverse isotropy. to a relatively large element size, jagged boundaries, and a mesh convergence study (van Rietbergen et al., 1995b), incorrect boundary conditions.”
Self-citationThe relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741 · cited 3×
“Several multiple regression analyses based on Cowin’s relations have been published (Goulet et al., 1994; Snyder and Hayes, 1990; Turner et al., 1990; van Rietbergen et al., 1996b). but none of these have allowed an isolated study of alignment.”
InfluentialStatistical Analysis of Spherical Data.
Jupp, P. E., Fisher, N. I., Lewis, T., & Embleton, B. J. J. (1988) · Biometrics · doi:10.2307/2531880 · Cited by 704
Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions
Odgaard, A., & Gundersen, H. J. G. (1993) · Bone · doi:10.1016/8756-3282(93)90245-6 · Cited by 680 · cited 1×
“Previously described segmentation (Odgaard et al., 1994) and purification (Odgaard and Gundersen, 1993) methods were used.”
MethodSelf-citationDistribution of directional data and fabric tensors
Ken-Ichi, K. (1984) · International Journal of Engineering Science · doi:10.1016/0020-7225(84)90090-9 · Cited by 663
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603 · cited 3×
“The mean intercept length (MIL) method (Harrigan and Mann, 1984; Whitehouse, 1974) quantifies the anisotropy of trabecular sur faces.”
The quantitative morphology of anisotropic trabecular bone
Whitehouse, W. J. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03878.x · Cited by 579 · cited 4×
“The mean intercept length (MIL) method (Harrigan and Mann, 1984; Whitehouse, 1974) quantifies the anisotropy of trabecular surfaces.”
Influential
Research works printed but not linked: 7
- Fisher. N. I.. Lewis, T. L. and Embleton, B. J. (1987) Statisrical Analysis qfSpherica/ Data. Cambridge University Press, Cambridge.
- Goulet, R. W., Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Feldkamp, L. A., Kruger, D.. Viviano, D.. Champlain, F. and Matthews. L. S. (1988) The effects of architecture and morphology on the mechanical properties of trabecular bone. Trans. Orthop. Res. Sot. 13, 73.
- Goulet, R. W., Feldkamp, L. A. and Goldstein, S. A. (1992) Quantifica- tion of the architecture of cancellous bone by surface and volume orientation methods. Tmns. Orthop. Res. Sot. 17. 159.
- Goulet, 1996, Determination of minimum microstructural analysis volumes for trabecular bone using 3-D stereology and FFT analysis, Trans. Orthop. Res. Soc., 21, 715
- Jacobs, 1993, A comparative study of automatic finite element mesh generation techniques in orthopaedic biomechanics, ASME/BED, 24, 512
- van Rietbergen, 1996, Fabric and density accurately predict the elastic properties of trabecular bone architecture, J. orthop. Res.
- Whitehouse, 1981, Irregularities and asymmetrics in trabecular bone in the innominate and elsewhere, Metab. Bone Dis. Rel. Res., S2, 271
Cited by
Items 201–300 of 377
Effect of including damage at the tissue level in the nonlinear homogenisation of trabecular bone
Levrero-Florencio, F., Manda, K., Margetts, L., & Pankaj, P. (2017) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-017-0913-7 · Cited by 15
“However, bone mineral density alone is not enough to accurately predict the stiffness of trabecular bone at the macroscale since it is known to be anisotropic, mostly because of its heavily directional microstructure (Odgaard et al. 1997; Turner et al. 1990).”
BackgroundMethodElastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra
Unnikrishnan, G. U., Gallagher, J. A., Hussein, A. I., Barest, G. D., & Morgan, E. F. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4031415 · Cited by 13
“Prior studies of trabecular anisotropy have concluded that the specimens examined exhibit orthotropy and, in some cases such as vertebral trabecular bone, transverse isotropy in their elastic behavior [1].”
BackgroundResultTortuosity and the Averaging of Microvelocity Fields in Poroelasticity
Souzanchi, M. F., Cardoso, L., & Cowin, S. C. (2012) · Journal of Applied Mechanics · doi:10.1115/1.4007923 · Cited by 13
Boehm, H. F., Lutz, J., Körner, M., Mutschler, W., Reiser, M. F., & Pfeifer, K. J. (2008) · Osteoporosis International · doi:10.1007/s00198-008-0663-6 · Cited by 13
“[36] are key features that determine the strength of trabecular bone.”
BackgroundEffects of damage on the orthotropic material symmetry of bovine tibial trabecular bone
Liu, X., Wang, X., & Niebur, G. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00217-3 · Cited by 13
High-Resolution Imaging Techniques for Bone Quality Assessment
Burghardt, A. J., Krug, R., & Majumdar, S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809965-0.00055-0 · Cited by 13
Impact of vaginal synthetic prolapse meshes on the mechanics of the host tissue response
Feola, A. (2011) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 11
An image-based approach for structure investigation and 3D numerical modelling of polymeric foams
Tagliabue, S., Andena, L., Nacucchi, M., & Pascalis, F. D. (2021) · Journal of Polymer Research · doi:10.1007/s10965-021-02438-9 · Cited by 11
3D histomorphometric quantification from 3D computed tomography
de Oliveira, L. F., & Lopes, R. T. (2004) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2004.03.105 · Cited by 11
da Silva, A. M. H. (2009) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.82.2009.tde-29062010-112929 · Cited by 11
Trabecular architecture of the distal femur in extant hominids
Lukova, A., Dunmore, C. J., Bachmann, S., Synek, A., Pahr, D. H., Kivell, T. L., & Skinner, M. M. (2024) · Journal of Anatomy · doi:10.1111/joa.14026 · Cited by 10
“To create a canonical bone, we used 15 humans, 14 gorillas, 15 chimpanzees DA was calculated using the mean intercept length method (Odgaard et al., 1997; Whitehouse, 1974).”
MethodLuo, C., Yang, X., & Yuan, H. (2022) · Materials Science and Engineering A · doi:10.1016/j.msea.2022.143286 · Cited by 10
Cole, J. H., & van der Meulen, M. C. H. (2009) · Humana Press eBooks · doi:10.1007/978-1-59745-459-9_7 · Cited by 10
Micromechanics of Bone Modeled as a Composite Material
Jasiuk, I. (2017) · Springer eBooks · doi:10.1007/978-3-319-52794-9_10 · Cited by 10
Quantification of trabecular spatial orientation from low-resolution images
Lenaerts, L., Wirth, A. J., & van Lenthe, H. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.908856 · Cited by 9
“The distribution patterns of the second principal direction (SPD) and third principal direction (TPD) calculated using GLD were more or less identical, but displayed a less dense pattern as FPD.”
BackgroundResultInfluentialLevrero-Florencio, F., & Pankaj, P. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00545 · Cited by 9
“It is well- recognized that the cellular microstructure of trabecular bone renders it anisotropic (Turner et al., 1990; Odgaard et al., 1997), i.e., properties at a point in space vary in different directions.”
BackgroundImage-Based Computational Biomechanics of the Musculoskeletal System
Chao, E. Y. S., Inoue, N., Elias, J. J., & Frassica, F. J. (2000) · Elsevier eBooks · doi:10.1016/b978-012077790-7/50023-0 · Cited by 9
Sierpowska, J. (2007) · UEF eRepo (University of Eastern Finland) · Cited by 9
Microarchitecture of cetacean vertebral trabecular bone among swimming modes and diving behaviors
Ingle, D. N., & Porter, M. E. (2020) · Journal of Anatomy · doi:10.1111/joa.13329 · Cited by 8
“Previous research has described bone volume fraction (BV/TV) and degree of anisotropy (DA) as two of the most biomechanically informative aspects of microarchitecture (Goldstein et al., 1993; Odgaard et al., 1997; van Rietbergen et al., 1998).”
BackgroundAgnelli, J., Colombo, M., Morroni, M., Bignotti, F., & Baldi, F. (2023) · Biomedical Engineering Advances · doi:10.1016/j.bea.2023.100073 · Cited by 8
Imposing thermodynamic restrictions on the elastic constant-fabric tensor relationship
Cowin, S. C. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00078-5 · Cited by 8
Long range node‐strut analysis of trabecular bone microarchitecture
Schmah, T., Marwan, N., Thomsen, J. S., & Saparin, P. I. (2011) · Medical Physics · doi:10.1118/1.3622600 · Cited by 8
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Wroński, S., Wit, A., Tarasiuk, J., & Lipiński, P. (2022) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-022-01678-y · Cited by 7
Haque, E., Xiao, P., Ye, K., & Wang, X. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105254 · Cited by 7
Lukova, A., Dunmore, C. J., Tsegai, Z. J., Bachmann, S., Synek, A., & Skinner, M. M. (2024) · American Journal of Biological Anthropology · doi:10.1002/ajpa.25023 · Cited by 7
“…assess the impact of scan resolution and downsampling on material maps of BV/TV and DA, which are some of the most biomechanically informative aspects of trabecular architecture and are widely reported in the literature (Goldstein et al., 1993; Odgaard et al., 1997; Van Rietbergen et al., 1998).”
Towards modelling of a trabecular bone
Brožovský, J., & Pankaj, P. (2006) · Computers & Structures · doi:10.1016/j.compstruc.2006.08.037 · Cited by 7
Novel magnetic resonance technique for characterizing mesoscale structure of trabecular bone
Nguyen, C., Schlesinger, K. J., James, T. W., James, K. M., Sah, R. L., Masuda, K., & Carlson, J. M. (2018) · Royal Society Open Science · doi:10.1098/rsos.180563 · Cited by 7
“The anisotropy of the trabecular structure has also been shown to be predictive of bone mechanics [18].”
BackgroundLim, D., Seliktar, R., Wee, J., Tom, J. A., & Nunes, L. W. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2165698 · Cited by 7
A bionic approach for topology optimization for tension-only or compression-only design
Cai, K., & Shi, J. (2010) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(10)60272-7 · Cited by 7
Rieger, R. (2011) · theses.fr (ABES) · doi:10.70675/ad781ab0z43b9z43a4zaf69z46aed5ebab0c · Cited by 8
Trabecular Architecture of the Proximal Tibia in Extant Hominids
Lukova, A., Bachmann, S., Synek, A., Pahr, D. H., Kilbourne, B. M., Dunmore, C. J., Kivell, T. L., & Skinner, M. M. (2025) · American Journal of Biological Anthropology · doi:10.1002/ajpa.70084 · Cited by 6
“DA was calculated using the mean- intercept-length method (Odgaard et al. 1997; Whitehouse 1974) cHMA was used to quantitatively analyze the rBV/TV and DA values in the meshes of each proximal tibia following published protocols (Bachmann et al. 2022).”
Webb, N. M. (2021) · Evolutionary Biology · doi:10.1007/s11692-021-09543-z · Cited by 6
“…standardize the VOI placement and the VOI in situ with transparency set to 60% and d the resultant VOI and the subsequent filtering steps used to generate the binarized stacks used in calculating the mean intercept length 1 3 as these measures are more biomechanically informative (Odgaard, 1997).”
MethodMicro-modelling and Analysis of Actual and Idealised Cancellous Structure
Kadir, M. R. A., Syahrom, A., Yusof, M. A. R., & Kamsah, N. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69139-6_110 · Cited by 6
“Several experimental studies have been carried out and confirmed the orthotropic and transversely isotropic nature of cancellous bone [7,10,11].”
BackgroundCardoso, L., & Schaffler, M. B. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029179 · Cited by 6
Moshage, S. G., McCoy, A. M., & Kersh, M. E. (2023) · Journal of Biomechanical Engineering · doi:10.1115/1.4062488 · Cited by 6
Correlations between fabric tensors computed on cone beam and micro computed tomography images
Moreno, R., Borga, M., Klintström, E., Brismar, T. B., & Smedby, Ö. (2013) · CRC Press eBooks · doi:10.1201/b15810-73 · Cited by 6
“From the clinical point of view, it seems more relevant to track changes in anisotropy than in the orientation of trabecular bone under treatment, since osteoporosis can have more effect on its anisotropy than on its orientation (Odgaard et al. 1997, Huiskes 2000).”
BackgroundHigh-Resolution Imaging Techniques for Bone Quality Assessment
Burghardt, A. J., Krug, R., & Majumdar, S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-381978-9.10050-2 · Cited by 6
Topology Optimization of Continuum Structures Based on a New Bionics Method
Cai, K., Chen, B., & Zhang, H. W. (2007) · International Journal for Computational Methods in Engineering Science and Mechanics · doi:10.1080/15502280701375494 · Cited by 6
Prediction of distal radius fracture load using HR-pQCT-based finite element analysis
Varga, P. (2009) · reposiTUm (TU Wien) · Cited by 6
Topology Optimization for Human Proximal Femur Considering Bi-modulus Behavior of Cortical Bones
Cai, K., Luo, Z., & Wang, Y. (2014) · Springer proceedings in mathematics & statistics · doi:10.1007/978-3-319-08377-3_26 · Cited by 5
Trabecular Anisotropy in the Primate Mandibular Condyle Is Associated with Dietary Toughness
Coiner‐Collier, S., Vogel, E. R., & Scott, R. S. (2018) · The Anatomical Record · doi:10.1002/ar.23810 · Cited by 5
“Packages APE (Paradis et al., 2004) and caper (Orme et al., 2013) were used for PGLS. Body size was not included in analyses for two reasons.”
MethodBernard, D., Léonard, F., Plougonven, E., & Bruno, G. (2020) · The Philosophical Magazine A Journal of Theoretical Experimental and Applied Physics · doi:10.1080/14786435.2020.1798532 · Cited by 5
Bennison, M. B. L., Pilkey, A. K., & Lievers, W. B. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047679 · Cited by 5
Biomechanical Behavior Characterization and Constitutive Models of Porcine Trabecular Tibiae
Quintana-Barcia, C., Rodríguez, C., Álvarez, G., & Maestro, A. (2021) · Biology · doi:10.3390/biology10060532 · Cited by 5
“The lack of biological material prompted the decision of using only transverse for loading, since this direction is likely to show lower values of stiffness and strength [35,36].”
BackgroundInfluence of hydration on fiber geometry in electrospun scaffolds
Ebersole, G. C., Paranjape, H. M., Anderson, P. M., & Powell, H. M. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.07.028 · Cited by 5
Turunen, M. J. (2013) · UEF eRepo (University of Eastern Finland) · Cited by 5
Fractures of the proximal femur: correlates of radiological evidence of osteoporosis
Cristofolini, L. (2007) · Skeletal Radiology · doi:10.1007/s00256-007-0299-1 · Cited by 5
Influence de l’hétérogénéité des propriétés mécaniques sur la résistance de l’os trabéculaire humain
Dépalle, B. (2011) · theses.fr (ABES) · doi:10.70675/bf4d472cz0dd4z4d20za7f2zd8806f663dd6 · Cited by 5
“D’un point de vue mécanique, on considère généralement l’os comme orthotrope [462, 446], voire, dans certain cas, comme isotrope transverse [312].”
Does cortical bone thickness in the last sacral vertebra differ among tail types in primates?
Nishimura, A. C., & Russo, G. A. (2017) · American Journal of Physical Anthropology · doi:10.1002/ajpa.23167 · Cited by 4
Klatt, M. A., Schröder‐Turk, G. E., & Mecke, K. R. (2017) · Medical Physics · doi:10.1002/mp.12281 · Cited by 4
“Therefore, we intersect the one-dimensional test line LðuÞ with the d-dimensional realization of the Boolean model B 1⁄4 Si KðriÞ: Bð1Þ u :1⁄4 LsðuÞ \ B: (8)”
Moreno, R., Borga, M., Klintström, E., Brismar, T. B., & Smedby, Ö. (2015) · Lecture notes in computational vision and biomechanics · doi:10.1007/978-3-319-13407-9_13 · Cited by 4
Elastic Properties of Bone Tissue
Cowin, S. C. (2001) · Elsevier eBooks · doi:10.1016/b978-012443341-0/50106-x · Cited by 4
Architectural 3-D Parameters and Anisotropic Elastic Properties of Cancellous Bone
Odgaard, A., Kabel, J., van Rietbergen, B., & Huiskes, R. (1999) · Solid mechanics and its applications · doi:10.1007/0-306-46939-1_4 · Cited by 4
Self-citationYang, S. (2006) · ThinkIR: The University of Louisville's Institutional Repository (University of Louisville) · doi:10.18297/etd/1612 · Cited by 4
BONE PROPERTIES - A REVIEW FOR DRILLING APPLICATION
Hussein, R., Landon, Y., & Araújo, A. C. (2023) · Brazilian Congress on Manufacturing Engineering (COBEF) · doi:10.26678/abcm.cobef2023.cof23-0563 · Cited by 3
Volume-Based Fabric Tensors through Lattice-Boltzmann Simulations
Moreno, R., & Smedby, Ö. (2014) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2014.548 · Cited by 3
“For example, the tensor scale [10], the star volume and length distributions [11] and the tortuosity tensor proposed in [12] compute directional statistics from intercepting lines traced from the sampled points.”
BackgroundOptimal Mass Distribution Prediction for Human Proximal Femur with Bi-modulus Property.
Shi, J., Cai, K., & Qin, Q. (2014) · PubMed · Cited by 3
Boyd, S. K., & Müller, R. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814841-9.00079-8 · Cited by 3
Quantifying the Directional Parameter of Structural Anisotropy in Porous Media
Chiang, M. Y. M., Wang, X., Landis, F. A., Dunkers, J. P., & Snyder, C. R. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.ft-117 · Cited by 3
Apparent stiffness tensors for porous solids using symmetric Galerkin boundary elements
Elmabrouk, B., Berger, J. R., Phan, A. ‐., & Gray, L. J. (2011) · Computational Mechanics · doi:10.1007/s00466-011-0650-1 · Cited by 3
“It has been shown in previous studies [24,31,32] that the principal axes of the fabric tensor are coincident with the principal axes of the material.”
BackgroundNATALI, A. N., & Hart, R. T. (2005) · Kluwer Academic Publishers eBooks · doi:10.1007/0-306-47583-9_15 · Cited by 3
“They have been shown to be highly correlated to one another, and highly correlated to the elastic anisotropy of trabecular bone (Odgaard et al., 1997).”
BackgroundSimulation of Osteoporosis Bone Changes: Effects on the Degree of Anisotropy
Pothuaud, L., Levitz, P., & Benhamou, C. L. (2001) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0651-5_12 · Cited by 3
Mechanical Behavior of Trabecular Bone
Mostakhdemin, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804634-0.00003-3 · Cited by 3
Pinos-Vélez, E. G., Pintado, M. S. B., Cabrera, M. A. C., & Serpa-Andrade, L. J. (2017) · IEEE International Symposium on Systems Engineering · doi:10.1109/syseng.2017.8088267 · Cited by 3
van Lenthe, H., & Huiskes, R. (1999) · Solid mechanics and its applications · doi:10.1007/0-306-46939-1_30 · Cited by 3
Self-citationTommy, K. A. (2018) · Cited by 3
A 2D stochastic micromechanical homogenization framework for trabecular bone
Luppino, F., Bellis, M. L. D., Falcinelli, C., Recrosi, F., & Vasta, M. (2026) · Meccanica · doi:10.1007/s11012-026-02114-6 · Cited by 3
Computer Simulations of Cancellous Bone Remodeling
van der Linden, J. C., Weinans, H., & Verhaar, J. A. N. (2004) · Humana Press eBooks · doi:10.1007/978-1-59259-736-9_17 · Cited by 2
Chen, H., Wang, D., Li, J. K., Yao, Q., Pugno, N. M., Li, Z., & Chen, Q. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03162-4 · Cited by 2
Elmabrouk, B., & Berger, J. R. (2012) · Computational Mechanics · doi:10.1007/s00466-012-0753-3 · Cited by 2
Badiei, A., Bottema, M. J., & Fazzalari, N. L. (2005) · International Conference on Digital Image Computing: Techniques and Applications (DICTA) · doi:10.1109/dicta.2005.35 · Cited by 2
“Since the LFD, SLD and SVD shift focus of measurement away from surface to the material itself [1, 9, 22] any changes to the distribution of material will be characterised.”
BackgroundMethodAPPROXIMATIONS OF STIFFNESS TENSOR OF BONE - DETERMINING AND ACCURACY
Piekarski, J., Kowalczyk-Gajewska, K., Waarsing, E., & Ma, M. (2004) · Cited by 2
Honda, K., Watari, I., Takei, M., & Ono, T. (2011) · Orthodontic Waves · doi:10.1016/j.odw.2011.07.001 · Cited by 2
“[23] Odgard A, Kabel J, van Rietbergen B, Dalstra M, Huiskes R.”
BackgroundBadiei, A., Bottema, M. J., & Fazzalari, N. L. (2006) · PubMed · Cited by 2
Multiscale simulation of bone regeneration in ti ssue engineering processes
Castellano, M. D. (2008) · Cited by 2
Cole, J. H., & van der Meulen, M. C. H. (2020) · Contemporary Endocrinology · doi:10.1007/978-3-319-69287-6_10 · Cited by 2
Wang, X., Nyman, J. S., Dong, X., Leng, H., & Reyes, M. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02579-2_4 · Cited by 2
da Silva, A. M. H. (2014) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.82.2014.tde-30102014-160356 · Cited by 2
Gudde, A. N. (2018) · Research Repository (Delft University of Technology) · Cited by 2
Prot, M. (2015) · theses.fr (ABES) · doi:10.70675/a1084892z1c70z4233zb77cz230185a16af9 · Cited by 2
Fabric Tensor-based Poroelastic Materials: a "Direct" Approach
Pernice, M. C. (2008) · Università degli Studi di Napoli Federico II · doi:10.6092/unina/fedoa/3128 · Cited by 1
Lim, D., Kim, H., Kim, J.-S., Seliktar, R., & Lee, S. J. (2009) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-008-1103-4 · Cited by 1
“To date, numerous studies have investigated the material, mechanics, and morphology of cancellous bone [ 1-23 ].”
BackgroundMethodDoblaré, M., Pérez-Aliacar, M., Ayensa-Jiménez, J., & Ashrafi, M. (2025) · Mechanics of Materials · doi:10.1016/j.mechmat.2025.105546 · Cited by 1
Forward and inverse optimality problems of bone adaptation at the homogenised RVE level
Zysset, P. K. (2026) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-02024-8 · Cited by 1
“…was also confirmed that the principal directions of the fabric tensor coincide with the orthotropic axes of symmetry of the apparent stiffness tensor (Odgaard et al. 1997) and fabric–elasticity relationships (Cowin 1985; Zysset and Curnier 1995) could be validated with larger experimental and…”
Magnetic Resonance of Bone Microstructure and Chemistry
Wehrli, F. W. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00108-2 · Cited by 1
Dyess, J. E., Hansen, V. L., & Goscinak, C. (2014) · Precambrian Research · doi:10.1016/j.precamres.2014.11.010 · Cited by 1
The Role of Microarchitecture on Absorption and Scattering of Ultrasound Waves in Trabecular Bone
Cardoso, L., & Cowin, S. C. (2013) · Fifth Biot Conference on Poromechanics · doi:10.1061/9780784412992.143 · Cited by 1
Geer, S. (2014) · Digital Collections of Colorado (Colorado State University) · Cited by 1
3.24 Magnetic Resonance of Bone Microstructure and Chemistry ☆
Wehrli, F. W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10128-6 · Cited by 1
Evaluation of bone strength: microtomographic tecniques
Tassani, S. (2009) · AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna) · doi:10.6092/unibo/amsdottorato/1695 · Cited by 1
Estimation of Bone Permeability for Poroelastic Analysis
KAMEO, Y., TSUBOTA, K.-I., & ADACHI, T. (2018) · Frontiers of biomechanics · doi:10.1007/978-4-431-56514-7_4 · Cited by 1
Chabrand, P. R. (2018) · EMC - Aparato Locomotor · doi:10.1016/s1286-935x(18)92752-8 · Cited by 1
Stereological analysis of short basalt fiber composites
Lionetto, F., Montagna, F., Moscatello, A., Natali, D., Caretto, F., Pascalis, F. D., Nacucchi, M., & Maffezzoli, A. (2019) · AIP conference proceedings · doi:10.1063/1.5140313 · Cited by 1
Advanced Structural Assessment of Bone Using CT and MRI
Guo, X.-D. E., Liu, X. S., & Wehrli, F. W. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-374602-3.00045-6 · Cited by 1
Cole, J. H. (2007) · eCommons (Cornell University) · Cited by 1
Characterization of dry and wet sawdust porous beds
Parmentier, N., Plougonven, E., Léonard, A., & Jeanmart, H. (2014) · Powder Technology · doi:10.1016/j.powtec.2014.05.006 · Cited by 1
Hazrati, J. (2013) · TU/e Research Portal · doi:10.6100/ir759548
Morphology and mechanical properties of the cancellous bone in the mandibular condyle
Giesen, E. B. W. (2002) · UvA-DARE (University of Amsterdam) · Cited by 1
Metadata
- Authors
- Odgaard, A., Kabel, J., van Rietbergen, B., Dalstra, M., & Huiskes, R.
- Affiliations
- Aarhus University Hospital (DK)
- Radboud University Nijmegen (NL)
- Corresponding author
- Odgaard, Anders
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1997-05
- Volume
- 30
- Issue
- 5
- Pages
- 487-495
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2042695653
- Cited by
- 338
- References
- 32
- Citations by year
- 2026: 10 · 2025: 3 · 2024: 6 · 2023: 5 · 2022: 4 · 2021: 9 · 2020: 10 · 2019: 5 · 2018: 31 · 2017: 16 · 2016: 11 · 2015: 9 · 2014: 22 · 2013: 14 · 2012: 14
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion, other-oa)
- TU/e Research Portal (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion, other-oa)
- TU/e Research Portal (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- trabecular bone, trabecular bone microarchitecture, fabric tensor, mean intercept length, compliance matrix, finite element analysis, 3D reconstruction, Wolff's law, bone mechanics
- MeSH terms
- Animals, Biomechanical Phenomena, Bone and Bones, Elasticity, Image Processing, Computer-Assisted, Models, Biological, Whales, Anisotropy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.