Validation of a functional method for the estimation of hip joint centre location
Open accessThe DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Abstract
The present study assesses the accuracy with which the subject specific coordinates of the hip joint centre (HJC) in a pelvic anatomical frame can be estimated using different methods. The functional method was applied by calculating the centre of the best sphere described by the trajectory of markers placed on the thigh during several trials of hip rotations. Different prediction methods, proposed in the literature and in the present investigation, which estimate the HJC of adult subjects using regression equations and anthropometric measurements, were also assessed. The accuracy of each of the above-mentioned methods was investigated by comparing their predictions with measurements obtained on a sample of 11 male adult able-bodied volunteers using roentgen stereophotogrammetric analysis (RSA), assumed to provide the true HJC locations. Prediction methods estimated the HJC location at an average rms distance of 25-30 mm. The functional method performed significantly better and estimated HJCs within a rms distance of 13 mm on average. This result may be confidently generalised if the photogrammetric experiment is carefully conducted and an optimal analytical approach used. The method is therefore suggested for use in motion analysis when the subject's hip range of motion is not limited. In addition, the facts that it is not an invasive technique and that it has relatively small and un-biased errors, make it suitable for regression equations identification with no limit to sample size and population typology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“The accuracy with which the HJC location may be estimated is crucial in terms of error propagation to the relevant kinematics and kinetics (Crowninshield et al., 1977; Cappozzo, 1986; Woltring and Fioretti, 1989; Kadaba et al., 1990; Pennock and Clark, 1990; Ramakrishnan and Kadaba, 1991; Cappozzo, 1991).”
BackgroundA gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 2×
“and from Davis et al. (1991):”
MethodCappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Self-citationA comparison of the accuracy of several hip center location prediction methods
Bell, A. L., Pedersen, D. R., & Brand, R. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90054-7 · Cited by 884
A study of lower-limb mechanics during stair-climbing.
Andriacchi, T. P., Andersson, G. B., Fermier, R. W., Stern, D., & Galante, J. O. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062050-00008 · Cited by 765 · cited 2×
“Regression coefficients have been obtained using imaging techniques on relatively small sample sizes of living adult males (Crowninshield et al., 1978; Andriacchi et al., 1980; Tylkowski, 1982; Bell et al., 1989, 1990; Davis et al., 1991) or direct measurements on a sample of adult male cadaveric specimens (Seidel et…”
MethodDetermining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735 · cited 1×
“Instantaneous positions and orientations of pelvis and thigh technical frames were optimally estimated using the reconstructed positions of the relevant markers and a least squares algorithm (Söderkvist and Wedin, 1993).”
MethodRoentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Prediction of hip joint centre location from external landmarks
Bell, A. L., Brand, R. A., & Pedersen, D. R. (1989) · Human Movement Science · doi:10.1016/0167-9457(89)90020-1 · Cited by 562
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
Selvik, G. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909154184 · Cited by 478
A biomechanical investigation of the human hip
Crowninshield, R. D., Johnston, R. C., Andrews, J. G., & Brand, R. A. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90045-3 · Cited by 448 · cited 1×
“Regression coefficients have been obtained using imaging techniques on relatively small sample sizes of living adult males (Crowninshield et al., 1978; Andriacchi et al., 1980; Tylkowski, 1982; Bell et al., 1989, 1990; Davis et al., 1991) or direct measurements on a sample of adult male cadaveric specimens (Seidel et…”
Method
Research works printed but not linked: 4
- Cappozzo, A., Leardini, A., Larsen, S.T., Catani, F., Benedetti, M.G., 1995b. A comparison of the accuracy of several hip centre location methods by using RSA techinque. Proceedings of the XVth Congress of the I.S.B. Jyvaskyla, Finland, pp. 152–153,.
- Crowninshield, R.D., Johnston, R.C., Andrews, J.G., Brand, R.A., 1977. The effect of joint center on hip kinetics. Proceedings of the 23rd Annual ORS Convention. Las Vegas, Nevada, pp. 47–49.
- Tylkowski, C.M., Simon, S.R., Mansour, J.M., 1982. Internal rotation gait in spastic cerebral palsy in the hip. Proceedings of the 10th Open Scientific Meeting of the Hip Society. Mosby, St. Louis, pp. 89–125.
- Woltring, H.J., Fioretti, S., 1989. Representation and photogrammetric calculation of 3-D joint movement. Proceedings of the 1st I.O.C. World Congress on Sport Science. Colorado Spring, pp. 350–351.
Cited by
Items 101–200 of 435
Effect of sex and fatigue on single leg squat kinematics in healthy young adults
Weeks, B. K., Carty, C. P., & Horan, S. A. (2015) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-015-0739-3 · Cited by 61
“Calibration trials required subjects to stand in the anatomical position as well as perform hip and knee joint movement tasks [21, 22].”
BackgroundBowersock, C. D., Willy, R. W., DeVita, P., & Willson, J. D. (2017) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2017.02.004 · Cited by 54
Gustafson, J. A., Anderton, W., Sowa, G., Piva, S. R., & Farrokhi, S. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.10.032 · Cited by 56
“Virtual markers were calibrated at the hip joint center using a previously published functional method [21] and at the knee and ankle joint centers by anatomical digitization (The MotionMonitor, Chicago, IL, USA).”
MethodPillet, H., Sangeux, M., Hausselle, J., Rachkidi, R., & Skalli, W. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.08.020 · Cited by 53
“used a similar technique based X-ray (called RSA) to compare the position of the HJC output by predictive and functional methods [4].”
MethodPeters, A., Baker, R. J., Morris, M. E., & Sangeux, M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.03.011 · Cited by 57
Landing Biomechanics in Participants With Different Static Lower Extremity Alignment Profiles
Nguyen, A., Shultz, S. J., & Schmitz, R. J. (2015) · Journal of Athletic Training · doi:10.4085/1062-6050-49.6.03 · Cited by 52
“We used the method of Leardini and colleagues[32] to determine the hip-joint center.”
MethodCollins, A. T., Blackburn, J. T., Olcott, C., Yu, B., & Weinhold, P. S. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2011.04.011 · Cited by 52
“The hip joint center was determined using Leardini's method (Leardini et al., 1999).”
MethodLocomotion Mechanics in Obese Adults and Children
Browning, R. C. (2012) · Current Obesity Reports · doi:10.1007/s13679-012-0021-z · Cited by 54
Is the human acetabulofemoral joint spherical?
Cereatti, A., Margheritini, F., Donati, M., & Cappozzo, A. (2010) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.92b2.22625 · Cited by 48
Self-citationFaber, G. S., Kingma, I., & van Dieën, J. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.019 · Cited by 54
“As we expected a substantial joint centre location error in the hip, we tried an alternative hip joint centre calculation in which leg length is used as additional input (Leardini et al., 1999), but this increased rather than reduced resulting differences in hip and L5/S1 moments.”
BackgroundBilateral, Misalignment-Compensating, Full-DOF Hip Exoskeleton: Design and Kinematic Validation
Junius, K., Degelaen, M., Lefeber, N., Swinnen, E., Vanderborght, B., & Lefeber, D. (2017) · Applied Bionics and Biomechanics · doi:10.1155/2017/5813154 · Cited by 47
“Errors of 8– 13mm between the estimated and actual hip joint center are considered a good approximation [49, 50].”
BackgroundMeardon, S. A., Derrick, T. R., Willson, J. D., Baggaley, M., Steinbaker, C. R., Marshall, M. B., & Willy, R. W. (2021) · The American Journal of Sports Medicine · doi:10.1177/03635465211014854 · Cited by 46
“A static motion calibration trial and functional hip joint trial were performed to define the lower extremity coordinate systems and joint centers for subsequent motion analysis.(29) Hip joint centers were determined from the trajectories of the thigh markers during active hip rotation using a spherical fit algorithm.”
MethodMahaffey, R., Morrison, S. C., Drechsler, W. I., & Cramp, M. (2013) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-6-43 · Cited by 51
Leboeuf, F., Reay, J., Jones, R. K., & Sangeux, M. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.02.010 · Cited by 49
Liang, B. W., Wu, W. H., Meijer, O. G., Lin, J., Lv, G. R., Lin, X. C., Prins, M. R., Hu, H., van Dieën, J. H., & Bruijn, S. M. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.06.006 · Cited by 50
“Hip joint centres (HJCs) were determined from the positions of the anterior and posterior superior iliac spines by using a validated method [23].”
MethodMichaud, B., Jackson, M. I., Arndt, A., Lundberg, A., & Begon, M. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.12.004 · Cited by 45
“Many algorithms have been presented in the literature including concentric sphere fitting techniques [14,25], transformation techniques [9], unscented Kalman filtering [21] and even markerless techniques [6].”
MethodBaldon, R. D. M., Piva, S. R., Silva, R. S., & Serrão, F. V. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546515574690 · Cited by 47
“The hip joint center was estimated using the functional approach described elsewhere.(23) The C7-T1, T12-L1, and L5-S1 joint spaces were also digitized, and the trunk and pelvis angles were designated by the sternal and sacral sensors.”
MethodFemoral anatomical frame: assessment of various definitions
Croce, U. D., Camomilla, V., Leardini, A., & Cappozzo, A. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00032-8 · Cited by 50
Self-citationLower-Limb Kinematics of Single-Leg Squat Performance in Young Adults
Horan, S. A., Watson, S. L., Carty, C. P., Sartori, M., & Weeks, B. K. (2014) · Physiotherapy Canada · doi:10.3138/ptc.2013-09 · Cited by 43
Shultz, S. J., Pye, M. L., Montgomery, M. M., & Schmitz, R. J. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512461744 · Cited by 51
Effects of obesity and foot arch height on gait mechanics: A cross-sectional study
Kim, D., Lewis, C. L., & Gill, S. V. (2021) · PLoS ONE · doi:10.1371/journal.pone.0260398 · Cited by 50
Ambegaonkar, J. P., Shultz, S. J., Perrin, D. H., Schmitz, R. J., Ackerman, T. A., & Schulz, M. R. (2010) · Sports Health A Multidisciplinary Approach · doi:10.1177/1941738110385998 · Cited by 42
“Kinematic data were collected with position sensors on the lower extremity, followed by standard digitization procedures.(26,29,48) Participants performed 5 double-leg drop jumps from the 45-cm box (Figure 1).”
MethodValidation of 3-D freehand ultrasound for the determination of the hip joint centre
Peters, A., Baker, R. J., & Sangeux, M. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.01.014 · Cited by 42
Identification of Temporal Pathomechanical Factors during the Tennis Serve
Martin, C., Kulpa, R., ROPARS, M., Delamarche, P., & Bideau, B. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318299ae3b · Cited by 50
“Players were equipped with 38 retroreflective markers placed on anatomical landmarks determined in agreement with previously published data (23,32).”
MethodThe test-retest reliability of three different hip joint centre location techniques
SINCLAIR, J. K., Taylor, P., Currigan, G., & Hobbs, S. (2013) · Movement & Sport Sciences - Science & Motricité · doi:10.1051/sm/2013066 · Cited by 44
Changes in Drop-Jump Landing Biomechanics During Prolonged Intermittent Exercise
Schmitz, R. J., Cone, J. C., Tritsch, A. J., Pye, M. L., Montgomery, M. M., Henson, R. A., & Shultz, S. J. (2013) · Sports Health A Multidisciplinary Approach · doi:10.1177/1941738113503286 · Cited by 45
“The hip center was calculated using the rotational method.(21) The foot, shank, and thigh local coordinate systems were defined by first creating a long axis (Y) of each segment, as established through the previously defined joint centers (foot distal point defined as the end of second ray).”
MethodKainz, H., Carty, C. P., Maine, S., Walsh, H. P. J., Lloyd, D. G., & Modenese, L. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.002 · Cited by 48
Cyclic Variations in Multiplanar Knee Laxity Influence Landing Biomechanics
Shultz, S. J., Schmitz, R. J., Kong, Y., Dudley, W. N., Beynnon, B. D., Nguyen, A., Kim, H., & Montgomery, M. M. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bfb25 · Cited by 43
Assi, A., Sauret, C., Massaad, A., Bakouny, Z., Pillet, H., Skalli, W., & Ghanem, I. B. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.04.028 · Cited by 45
“Fluoroscopy has been previously used in some of the validation studies [9,15].”
MethodResultA hip joint kinematics driven model for the generation of realistic thigh soft tissue artefacts
Camomilla, V., Cereatti, A., Chèze, L., & Cappozzo, A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.09.018 · Cited by 40
“Despite the resources invested, the accuracy of HJC location estimates based on the functional method and noninvasive experimental set-ups is in the order of 20–30 mm (Cereatti et al., 2009; Hicks and Richards, 2005; Leardini et al., 1999; Sangeux et al., 2011).”
BackgroundSelf-citationNew Lower-Limb Gait Asymmetry Indices Based on a Depth Camera
Auvinet, E., Multon, F., & Meunier, J. (2015) · Sensors · doi:10.3390/s150304605 · Cited by 40
“Surface reflective markers were placed over standardized anatomical landmarks, as suggested by the International Society of Biomechanics [20], enabling us to accurately evaluate joint centers, as described in [21].”
MethodCorazza, S., Mündermann, L., & Andriacchi, T. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.029 · Cited by 48
Energy Absorption as a Predictor of Leg Impedance in Highly Trained Females
Kulas, A. S., Schmitz, R. J., Shultz, S. J., Watson, M. A., & Perrin, D. H. (2006) · Journal of Applied Biomechanics · doi:10.1123/jab.22.3.177 · Cited by 40
Femur shape prediction by multiple regression based on quadric surface fitting
Sholukha, V. A., Chapman, T. J., Patrick Salvia, A., Moiseev, F., Euran, F., Rooze, M. A., & Jan, S. V. S. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.10.039 · Cited by 39
“Indeed, they use particular motion patterns and seem satisfactory for ball-and-socket joints in normal conditions (Cappozzo, 1984; Leardini et al., 1999), but the samemotion patterns are often too complex for patients showing a limited joint range (Di Silvestro et al.”
BackgroundFavre, J., Crevoisier, X. M., Jolles, B. M., & Aminian, K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.041 · Cited by 41
“The femoral head was localized through a thigh circumduction movement (Leardini et al., 1999), and the other ALs by palpation.”
MethodAccurate Determination of a Joint Rotation Center Based on the Minimal Amplitude Point Method
Marin, F., Mannel, H., Claes, L., & Dürselen, L. (2003) · Computer Aided Surgery · doi:10.3109/10929080309146100 · Cited by 39
Tang, J., McGrath, M., Laszczak, P., Jiang, L., Bader, D. L., Moser, D., & Zahedi, S. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.10.004 · Cited by 38
Methodological considerations of task and shoe wear on joint energetics during landing
Shultz, S. J., Schmitz, R. J., Tritsch, A. J., & Montgomery, M. M. (2011) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.11.001 · Cited by 41
“Joint centers were determined using Leardini et al. (1999) (hip) and centroid (Madigan and Pidcoe 2003) (knee and ankle) methods.”
MethodMinimum measured-input models for the assessment of motor ability
Cappozzo, A. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00186-5 · Cited by 37
Self-citationMenceur, M. O. A. E., Pudlo, P., Gorce, P., Thévenon, A., & Lepoutre, F.-X. (2008) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2008.02.019 · Cited by 36
Auvinet, E., Multon, F., Manning, V., Meunier, J., & Cobb, J. P. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.08.022 · Cited by 36
Influence of Lean Body Mass and Strength on Landing Energetics
Montgomery, M. M., Shultz, S. J., Schmitz, R. J., Wideman, L., & HENSON, R. A. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318268fb2d · Cited by 38
Parry, R., Dietrich, G., & Bril, B. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.00306 · Cited by 34
“The final model presented here presents movement relative to three degrees of freedom at each joint for a total of nine degrees of freedom.”
BackgroundMethodShum, G. L. K., Crosbie, J., & Lee, R. Y. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.06.028 · Cited by 33
Shimokochi, Y., Ambegaonkar, J. P., & Meyer, E. G. (2016) · Journal of Athletic Training · doi:10.4085/1062-6050-51.10.15 · Cited by 41
“Hip-joint center was defined as described by Leardini et al.27 The longitudinal axis for the local coordinate systems of the foot, shank, and thigh was aligned to the line between the tip of the second phalanx and the ankle-joint centers, between the ankle- and kneejoint centers, and between the knee- and hip-joint ce…”
MethodGu, D., Chen, Y., Dai, K., Zhang, S., & Yuan, J. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.12.013 · Cited by 35
Robotic surgery: from autonomous systems to intelligent tools
y Baena, F. R., & Davies, B. (2009) · Robotica · doi:10.1017/s0263574709990427 · Cited by 32
Leigh, R. J., Pohl, M. B., & Ferber, R. (2013) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2013.04.003 · Cited by 36
“Given that marker placement inaccuracy is thought to be one of the leading causes of error in 3DGA (Della Croce, Cappozzo, & Kerrigan, 1999), an advantage of the functional method over the predictive method, was thought to lie in its decreased reliance on the reliable placement of anatomical markers (Leardini et al.,…”
MethodResultBennett, H. J., Fleenor, K., & Weinhandl, J. T. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.10.003 · Cited by 32
The Conventional Gait Model - Success and Limitations
Baker, R. J., Leboeuf, F., Reay, J., & Sangeux, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-30808-1_25-2 · Cited by 52
Kinetic analyses of maximal effort soccer kicks in female collegiate athletes
Clagg, S., Warnock, A., & Thomas, J. S. (2009) · Sports Biomechanics · doi:10.1080/14763140902752106 · Cited by 30
Brunner, O., Mertens, A., Nitsch, V., & Brandl, C. (2021) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2021.1954791 · Cited by 30
“[36] to create a humanmodel based on scientific state of the art.”
BackgroundPerformance specification for lower limb orthotic devices
Johnson, G., Ferrarin, M., Harrington, M. S., Hermens, H. J., Jonkers, I., Mak, P., & Stallard, J. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2003.10.001 · Cited by 32
“…may have been used for a KO(s), needs walking aid(s) Embedded segment frame The pelvic segment frame was established by using the left and right ASIS marker and a sacrum marker together with the calculated hip joint centre using methods described by Davis et al. (1991) and Leardini et al. (1999).”
MethodRiemer, R., & Hsiao‐Wecksler, E. T. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.011 · Cited by 34
“em can be derived from joint center studies (Bell et al., 1990; Leardini et al., 1999; Roux et al., 2002; Schwartz and Rozumalski, 2005).”
BackgroundMartelli, S., Kersh, M. E., & Pandy, M. G. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.08.001 · Cited by 29
Riemer, R., & Hsiao‐Wecksler, E. T. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.3005155 · Cited by 33
Martin, C., Sorel, A., Touzard, P., Bideau, B., Gaborit, R., DeGroot, H., & Kulpa, R. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1853335 · Cited by 30
“Players were equipped with 38 retroreflective markers placed on anatomical landmarks determined in agreement with previously published data (Leardini et al., 1999; Reed & Manary, 1999; Zatsiorsky et al., 1990).”
MethodDetermination of Functional Rotation Axes During Elevation of the Shoulder Complex
Doorenbosch, C. A. M., Mourits, A. J. J. M., Veeger, H. E. J., Harlaar, J., & van der Helm, F. C. T. (2001) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2001.31.3.133 · Cited by 28
Can the Open Stance Forehand Increase the Risk of Hip Injuries in Tennis Players?
Martin, C., Sorel, A., Touzard, P., Bideau, B., Gaborit, R., DeGroot, H., & Kulpa, R. (2020) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967120966297 · Cited by 27
“Players were equipped with 38 retroreflective markers placed on anatomic landmarks determined in agreement with previously published data.(28,40,50) A motion capture system (Vicon) was used to record the 3-dimensional trajectories of retroreflective markers on the landmarks.”
MethodIn vivo tests of an improved method for functional location of the subtalar joint axis
Lewis, G. S., Cohen, T. L., Seisler, A. R., Kirby, K. A., Sheehan, F. T., & Piazza, S. J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.010 · Cited by 27
“predicted estimates ( Leardini et al., 1999 ) because they are”
BackgroundEstimation of the centre of rotation: a methodological contribution
Cereatti, A., Camomilla, V., & Cappozzo, A. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00264-1 · Cited by 27
“Some are based on the hypothesis that the distal markers, or their centroid, lie, in any given instant of time during the movement, on a spherical surface the centre of which is the CR (Fig. 1; Cappozzo, 1984; Leardini et al., 1999; Piazza et al., 2001; Gamage and Lasenby, 2002).”
BackgroundMethodSelf-citationCereatti, A., Camomilla, V., Vannozzi, G., & Cappozzo, A. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.05.029 · Cited by 35
Self-citationThewlis, D., Richards, J., & Bower, J. (2008) · Journal of Applied Biomechanics · doi:10.1123/jab.24.2.185 · Cited by 27
“Functional joint center approaches (Leardini et al., 1999; Schwartz & Rozumalski, 2005) have been around for some time.”
BackgroundJo, S., Hooke, A. W., An, K., Trousdale, R. T., & Sierra, R. J. (2018) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2017.12.002 · Cited by 26
An approach for hip joint center calculation for use in seated postures
Bush, T. R., & Gutowski, P. E. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00168-4 · Cited by 30
“by thigh marker trajectories during hip rotation (Leardini et al., 1999; Piazza et al., 2001; Capozzo, 1984).”
BackgroundMethodHammond, C. V., Williams, S. T., Vega, M. M., Ao, D., Li, G., Salati, R. M., Pariser, K. M., Shourijeh, M. S., Habib, A. W., Patten, C., et al. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01629-5 · Cited by 28
Willy, R. W., Bigelow, M. A., Kolesar, A., Willson, J. D., & Thomas, J. S. (2016) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-016-4143-9 · Cited by 25
“First, a static motion calibration trial and functional hip joint trial [24] were collected to define the lower extremity coordinate systems for subsequent motion analysis.”
Esculier, J.-F., Willy, R. W., Baggaley, M., Meardon, S. A., & Willson, J. D. (2017) · The Knee · doi:10.1016/j.knee.2017.08.054 · Cited by 25
Sex differences in trunk, pelvis, hip and knee kinematics and eccentric hip torque in adolescents
Silva, R. S., & Serrão, F. V. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.08.004 · Cited by 27
Raptopoulos, L. S. C., Dutra, M. S., Pinto, F. A. D. N. C., & Filho, A. C. D. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.09.017 · Cited by 25
“The hip center of rotation was estimated through regression equations (Bell et al., 1989; Seidel et al., 1995; Leardini et al., 1999).”
MethodNon-invasive computer-assisted measurement of knee alignment
Clarke, J., Riches, P. E., Picard, F., & Deakin, A. H. (2011) · Computer Aided Surgery · doi:10.3109/10929088.2011.635217 · Cited by 24
“for the hip joint [29-32].”
Earliest Gait Deviations During Slips: Implications For Recovery
Beschorner, K. E., Redfern, M. S., & Cham, R. (2012) · IIE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/21577323.2012.660904 · Cited by 24
“Leardini regression equations were used to estimate hip joint centers (Leardini et al., 1999), and the calcaneous and metatarsal markers were used to define the foot segment (Cappozzo et al., 1995).”
MethodKiernan, D., Malone, A., O’Brien, T., & Simms, C. K. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.09.026 · Cited by 24
“The first, referred to as functional calibration, relies on relative movement of the segments usually during a number of calibration trials [2–4].”
BackgroundCalculating the hip center of rotation using contralateral pelvic anatomy
Durand‐Hill, M., Henckel, J., Satchithananda, K., Sabah, S. A., Hua, J., Hothi, H. S., Langstaff, R. J., Skinner, J. A., & Hart, A. J. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.23118 · Cited by 24
“Hip motion based methods are popular due to their relative non-invasiveness.(9) To determine the hCoR the femur is rotated relative to a pelvic frame of reference (usually the anterior pelvic plane).”
MethodBiomechanical analysis of the “waiter's serve” on upper limb loads in young elite tennis players
Touzard, P., Kulpa, R., Bideau, B., Montalvan, B., & Martin, C. (2018) · European Journal of Sport Science · doi:10.1080/17461391.2018.1539527 · Cited by 23
“Players were equipped with 38 retroreflective markers placed on anatomical landmarks determined in agreement with previously published data (Leardini et al., 1999; Reed, Manary, & Schneider, 1999; Zatsiorsky, Seluyanov, & Chugunova, 1990).”
MethodBack Pain Is Associated With Changes in Loading Pattern Throughout Forward and Backward Bending
Shum, G. L. K., Crosbie, J., & Lee, R. (2010) · Spine · doi:10.1097/brs.0b013e3181ecd71c · Cited by 29
Suter, L., Roth, A., Angst, M., von Knoch, F., Preiß, S., List, R., Ferguson, S. J., & Zumbrunn, T. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.11.031 · Cited by 25
Accurate simulation of hip joint range of motion
Kang, M., Sadri, H., Moccozet, L., Magnenat‐Thalmann, N., & Hoffmeyer, P. J. (2003) · Computer Animation (CA) · doi:10.1109/ca.2002.1017539 · Cited by 23
“The center of this sphere is the hip joint center [8][4][6].”
BackgroundBartels, W., Demol, J., Gelaude, F., Jonkers, I., & Sloten, J. V. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.890186 · Cited by 22
“Using bi-planar radiographs to locate the true HJC, Bell et al. (1990) found HJC estimation errors up to 35mm, with a mean of 19mm. Leardini et al. (1999) used similar methods to evaluate the regression equations published by Bell et al. (1990) and Davis et al. (1991), finding mean errors of,…”
MethodBrund, R. B. K., Rasmussen, S., Nielsen, R. O., Kersting, U. G., Læssøe, U., & Voigt, M. (2017) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12923 · Cited by 22
Bjornaraa, J., & Fabio, R. P. D. (2011) · Europe PMC (PubMed Central) · Cited by 22
Evaluation of functional methods for human movement modelling
Gastaldi, L., Lisco, G., & Pastorelli, S. (2015) · PubMed · doi:10.5277/abb-00151-2014-03 · Cited by 26
“Generally, functional methods provide more accurate results according to what is reported in literature [5], [9], [11], [14], [16]–[18], [20], [25], compared to the predictive ones.”
BackgroundResultEffect of Heading a Soccer Ball as an External Focus During a Drop Vertical Jump Task
Akbari, H., Kuwano, S., & Shimokochi, Y. (2023) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671231164706 · Cited by 23
“The hip joint center was defined by calculating the center of the best sphere described by the trajectory of motion sensors placed on the thigh during 5 hip rotational positions.(26) The longitudinal axes of the thorax, thigh, shank, and foot segment coordinate systems were aligned with lines connecting the C7 and T12…”
MethodChang, C., Wang, T., Wang, J., Sc, H., & Lu, T. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.21377 · Cited by 21
Horsak, B., Schwab, C., Clemens, C., Baca, A., Greber‐Platzer, S., Kreissl, A., & Kranzl, A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.09.029 · Cited by 23
Wasserberger, K. W., Barfield, J. W., Anz, A. W., Andrews, J. R., & Oliver, G. D. (2019) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2019.06.011 · Cited by 22
Beaulieu, M. L., & Palmieri‐Smith, R. M. (2013) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12051 · Cited by 24
“In addition, a functional method was used to determine the hip joint center – a method proven to be superior to the more common predictive methods that use regression equations (Leardini et al., 1999).”
MethodMultiplanar Knee Laxity Increases during a 90-min Intermittent Exercise Protocol
Shultz, S. J., Schmitz, R. J., Cone, J. R., Copple, T. J., Montgomery, M. M., Pye, M. L., & Tritsch, A. J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31828cb94e · Cited by 25
“Joint centers were determined via the centroid (ankle and knee) (15) and rotational method (hip) (13).”
MethodShape Analysis and Parameterized Modeling of Hip Joint
Xi, J., Hu, X., & Jin, Y. (2003) · Journal of Computing and Information Science in Engineering · doi:10.1115/1.1607353 · Cited by 21
Leestma, J. K., Mathur, S., Anderton, M., Sawicki, G. S., & Young, A. J. (2024) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2024.3371290 · Cited by 20
“Because this distance only has a standard deviation of ± 11.4 mm, which is well within the bounds of hip joint center estimations using non-invasive methods [26], we designed an actuator mount that holds both frontal actuators at this fixed distance (Fig.”
InfluentialEddison, N., Healy, A., Needham, R. A., & Chockalingam, N. (2019) · The Foot · doi:10.1016/j.foot.2019.101660 · Cited by 20
Slip and Fall Risks: Pre-Slip Gait Contributions and Post-Slip Response Effects
Moyer, B. E. (2006) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 23
Galetto, M., Gastaldi, L., Lisco, G., Mastrogiacomo, L., & Pastorelli, S. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914559736 · Cited by 20
Sholukha, V. A., Jan, S. V. S., Snoeck, O., Patrick Salvia, A., Moiseev, F., & Rooze, M. A. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.11.004 · Cited by 19
“They use particular movements to determine mechanical JCs and seem satisfactory for ball-and-socket joints in normal conditions (Camomilla et al., 2006; Cappozzo, 1984; Leardini et al., 1999).”
BackgroundCan the Acetabular Position be Derived from a Pelvic Frame of Reference?
Dandachli, W., Nakhla, A., Iranpour, F. G., Kannan, V., & Cobb, J. P. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0336-y · Cited by 19
“The alternative functional method involves determination of the center of rotation by fitting a sphere to paths followed by a femur-fixed point as motion occurs about the hip [6, 21, 27].”
MethodMontgomery, M. M., Shultz, S. J., & Schmitz, R. J. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.06.004 · Cited by 19
“Hip joint centers were calculated using the Leardinimethod (Leardini et al., 1999), while the knee and ankle joint centers were”
MethodRosario, H. D., Page, A. F., Besa, A. J., & Valera, Á. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.08.006 · Cited by 20
“For the experimental measure of the CoR, three typical calibration motions were used, 142 as defined in Table 1 (Leardini et al., 1999; Piazza et al., 2004).”
MethodEvaluation of alternative technical markers for the pelvic coordinate system
Fukuchi, R., Fukuchi, C. A., Orselli, M. I. V., & Duarte, M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.050 · Cited by 18
“methods of estimation of the HJCs (for these comparisons, see Cappozzo et al., 1997; Cereatti et al., 2009; Leardini et al., 1999).”
BackgroundMethodBiomechanical Differences Between the Bulgarian Split-Squat and Back Squat
Mackey, E. R., & Riemann, B. L. (2021) · International journal of exercise science · doi:10.70252/ciyt8956 · Cited by 29
“The hip-joint center was established using a series of 8 points along a circumduction cycle for each hip to approximate the apex of femoral motion (12).”
MethodLower-limb adaptation during squatting after isolated posterior cruciate ligament injuries
Liu, M., Chou, P.-H., Liaw, L.-J., & Su, F. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.06.014 · Cited by 18
Metadata
- Authors
- Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S.
- Affiliations
- Istituto Ortopedico Rizzoli (IT)
- University of Sassari (IT)
- Corresponding author
- Leardini, Alberto
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 32
- Issue
- 1
- Pages
- 99-103
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2140047417
- Cited by
- 415
- References
- 20
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 5 · 2023: 6 · 2022: 7 · 2021: 8 · 2020: 11 · 2019: 10 · 2018: 14 · 2017: 17 · 2016: 20 · 2015: 23 · 2014: 29 · 2013: 31 · 2012: 34
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Health Sciences › Medicine › Surgery › Hip disorders and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- functional methods, marker trajectories, sphere fitting, regression equations, anthropometry, roentgen stereophotogrammetric analysis, hip range of motion, motion analysis
- MeSH terms
- Adult, Anthropometry, Biomechanical Phenomena, Evaluation Studies as Topic, Forecasting, Hip Joint, Humans, Male, Models, Anatomic, Photogrammetry, Radiography, Regression Analysis, Rotation, Thigh
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.