Validation of a functional method for the estimation of hip joint centre location
Open accessThe DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Abstract
The present study assesses the accuracy with which the subject specific coordinates of the hip joint centre (HJC) in a pelvic anatomical frame can be estimated using different methods. The functional method was applied by calculating the centre of the best sphere described by the trajectory of markers placed on the thigh during several trials of hip rotations. Different prediction methods, proposed in the literature and in the present investigation, which estimate the HJC of adult subjects using regression equations and anthropometric measurements, were also assessed. The accuracy of each of the above-mentioned methods was investigated by comparing their predictions with measurements obtained on a sample of 11 male adult able-bodied volunteers using roentgen stereophotogrammetric analysis (RSA), assumed to provide the true HJC locations. Prediction methods estimated the HJC location at an average rms distance of 25-30 mm. The functional method performed significantly better and estimated HJCs within a rms distance of 13 mm on average. This result may be confidently generalised if the photogrammetric experiment is carefully conducted and an optimal analytical approach used. The method is therefore suggested for use in motion analysis when the subject's hip range of motion is not limited. In addition, the facts that it is not an invasive technique and that it has relatively small and un-biased errors, make it suitable for regression equations identification with no limit to sample size and population typology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“The accuracy with which the HJC location may be estimated is crucial in terms of error propagation to the relevant kinematics and kinetics (Crowninshield et al., 1977; Cappozzo, 1986; Woltring and Fioretti, 1989; Kadaba et al., 1990; Pennock and Clark, 1990; Ramakrishnan and Kadaba, 1991; Cappozzo, 1991).”
BackgroundA gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 2×
“and from Davis et al. (1991):”
MethodCappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Self-citationA comparison of the accuracy of several hip center location prediction methods
Bell, A. L., Pedersen, D. R., & Brand, R. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90054-7 · Cited by 884
A study of lower-limb mechanics during stair-climbing.
Andriacchi, T. P., Andersson, G. B., Fermier, R. W., Stern, D., & Galante, J. O. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062050-00008 · Cited by 765 · cited 2×
“Regression coefficients have been obtained using imaging techniques on relatively small sample sizes of living adult males (Crowninshield et al., 1978; Andriacchi et al., 1980; Tylkowski, 1982; Bell et al., 1989, 1990; Davis et al., 1991) or direct measurements on a sample of adult male cadaveric specimens (Seidel et…”
MethodDetermining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735 · cited 1×
“Instantaneous positions and orientations of pelvis and thigh technical frames were optimally estimated using the reconstructed positions of the relevant markers and a least squares algorithm (Söderkvist and Wedin, 1993).”
MethodRoentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Prediction of hip joint centre location from external landmarks
Bell, A. L., Brand, R. A., & Pedersen, D. R. (1989) · Human Movement Science · doi:10.1016/0167-9457(89)90020-1 · Cited by 562
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
Selvik, G. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909154184 · Cited by 478
A biomechanical investigation of the human hip
Crowninshield, R. D., Johnston, R. C., Andrews, J. G., & Brand, R. A. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90045-3 · Cited by 448 · cited 1×
“Regression coefficients have been obtained using imaging techniques on relatively small sample sizes of living adult males (Crowninshield et al., 1978; Andriacchi et al., 1980; Tylkowski, 1982; Bell et al., 1989, 1990; Davis et al., 1991) or direct measurements on a sample of adult male cadaveric specimens (Seidel et…”
Method
Research works printed but not linked: 4
- Cappozzo, A., Leardini, A., Larsen, S.T., Catani, F., Benedetti, M.G., 1995b. A comparison of the accuracy of several hip centre location methods by using RSA techinque. Proceedings of the XVth Congress of the I.S.B. Jyvaskyla, Finland, pp. 152–153,.
- Crowninshield, R.D., Johnston, R.C., Andrews, J.G., Brand, R.A., 1977. The effect of joint center on hip kinetics. Proceedings of the 23rd Annual ORS Convention. Las Vegas, Nevada, pp. 47–49.
- Tylkowski, C.M., Simon, S.R., Mansour, J.M., 1982. Internal rotation gait in spastic cerebral palsy in the hip. Proceedings of the 10th Open Scientific Meeting of the Hip Society. Mosby, St. Louis, pp. 89–125.
- Woltring, H.J., Fioretti, S., 1989. Representation and photogrammetric calculation of 3-D joint movement. Proceedings of the 1st I.O.C. World Congress on Sport Science. Colorado Spring, pp. 350–351.
Cited by
Items 201–300 of 435
Design of an anthropomorphic lower extremity exoskeleton with compatible joints
Yang, W., Yang, C.-J., & Wei, Q. (2014) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2014.7090525 · Cited by 18
Tang, J., McGrath, M., Hale, N., Jiang, L., Bader, D. L., Laszczak, P., Moser, D., & Zahedi, S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.08.014 · Cited by 18
SINCLAIR, J. K., Atkins, S. J., & Vincent, H. (2014) · Journal of Human Kinetics · doi:10.2478/hukin-2014-0106 · Cited by 17
“D kinematic data (Leardini et al., 1999; Marin et al., 2003; Piazza et al., 2001; Shea et al., 1997).”
MethodResultBiomechanics of the Hip During Gait
Sangeux, M. (2019) · Springer eBooks · doi:10.1007/978-3-030-12003-0_3 · Cited by 18
Influence of shoe torsional stiffness on foot and ankle biomechanics during tennis forehand strokes
Martin, C., Touzard, P., Horvais, N., Puchaud, P., Kulpa, R., Bideau, B., & Sorel, A. (2022) · European Journal of Sport Science · doi:10.1080/17461391.2022.2153232 · Cited by 17
Chang, C., Wang, T., Wang, J., Sc, H., & Lu, T. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.024 · Cited by 17
“The center of rotation of the hip was estimated using a functional method [21], and the centers of the knee and ankle joints were assumed to be on the mid-points between the femoral epicondyles and between the malleoli, respectively [7].”
MethodAssessment of reproducibility of thigh marker ranking during walking and landing tasks
Monnet, T., Thouzé, A., Pain, M. T., & Begon, M. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.05.006 · Cited by 21
Evaluation of the Lateral Step-Down Test as a Clinical Assessment of Hip Musculature Strength
Norcross, M. F., Halverson, S. D., Hawkey, T. J., Blackburn, J. T., & Padua, D. A. (2009) · Athletic Training & Sports Health Care · doi:10.3928/19425864-20091019-06 · Cited by 17
Hip joint center localisation: A biomechanical application to hip arthroplasty population
Bouffard, V., Begon, M., Champagne, A., Farhadnia, P., Vendittoli, P.-A., Lavigne, M., & Prince, F. (2012) · World Journal of Orthopedics · doi:10.5312/wjo.v3.i8.131 · Cited by 17
Padhye, A. A., Meardon, S. A., Kulas, A. S., & Willson, J. D. (2023) · Journal of Orthopaedic Research® · doi:10.1002/jor.25751 · Cited by 16
“20 Markers on the medial and lateral proximal tibia and medial and lateral malleoli defined the shanks.”
BackgroundChui, E. C., Leung, K. S., Qin, J., Shi, D., Augat, P., Wong, R. M. Y., Chow, S. K., Huang, X. Y., Chen, C. Y., Lai, Y., et al. (2020) · Engineering · doi:10.1016/j.eng.2020.02.017 · Cited by 17
“The literature has reported that the hip center can be calculated by fitting a best fitting sphere described by the trajectory of markers placed on the thigh [20,23].”
BackgroundThe effects of forefoot varus on hip and knee kinematics during single-leg squat
Silva, R. S., Maciel, C. D., & Serrão, F. V. (2014) · Manual Therapy · doi:10.1016/j.math.2014.07.001 · Cited by 20
“The hip joint center was estimated using the functional approach described by Leardini et al. (1999). Afterward, a static file was taken with the subject in anatomic position, for the determination of the neutral alignment angles of the joints.”
MethodWarlow, O. M., & Lawson, S. E. M. (2012) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411912442133 · Cited by 16
“For assessment of the hip joint Leardini et al.(35) found that functional methods found the joint centre within around 13mm of the geometric centre found using X-ray.”
MethodOlmedo-Garcia, N., Lopez‐Prats, F. A., Agullo, A., Ortu�o, A., & Palazón‐Quevedo, Á. (2000) · Skeletal Radiology · doi:10.1007/s002560000279 · Cited by 16
“Several methods have been described [8, 9, 10, 11, 12, 13 , 14] as helpful for determining the premorbid centre of rotation when the changes are bilateral.”
MethodHarvey, E., Sandhaus, H., Jacobs, A. Z., Moss, E., & Sloane, M. (2024) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3613904.3642004 · Cited by 19
“Reflecting on the social practices of each era, we can characterize the evolution of the social practices of measurement and validation, as in Figure 9.”
Impact of Capsulotomy on Hip Biomechanics during Arthroscopy
Lee, H., Lim, W., Lee, S., Jo, S., & Jo, S. (2022) · Medicina · doi:10.3390/medicina58101418 · Cited by 15
“The hip center of rotation was estimated using a functional approach that was achieved by performing flexion/extension, abduction/adduction, and circumduction three times while monitoring the 3D relative movement between the femur and pelvis [19,20].”
MethodWilson, D. A. J., Wilson, J. L. A., Richardson, G. C., & Dunbar, M. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.11.025 · Cited by 15
Vena, A., BUDNEY, D., Forest, T. W., & Carey, J. P. (2011) · Sports Engineering · doi:10.1007/s12283-010-0058-8 · Cited by 19
“[39], are shown in the pelvis local frame to provide a reference for joint location and are labelled RHJC and LHJC, respectively.”
BackgroundQuantifying Elbow Extension and Elbow Hyperextension in Cricket Bowling: A case study of Jenny Gunn
King, M. A., & Yeadon, M. R. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.682082 · Cited by 15
“A functional axis has the advantage of being specific to the individual and not particularly dependent upon marker placement (Leardini et al., 1999).”
BackgroundRegression models to predict hip joint centers in pathological hip population
Mantovani, G., Ng, K. C. G., & Lamontagne, M. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.11.001 · Cited by 15
“These equations were applied to the current dataset, the adult population in Harrington [5] and Leardini’s studies [19], and the prediction errors were reported in Table 3.”
MethodResultHip joint modeling for the control of the joint center and the range of motions
Kang, M., Sadri, H., Moccozet, L., & Magnenat‐Thalmann, N. (2003) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)33466-3 · Cited by 15
“The HJC has been located previously by predictive methods or functional methods (Bell, et al., 1990; Cappozzo, 2000; Kirkwood, et al., 1999; Leardini, et al., 1999; Piazza, et al., 2001; Seidel, et al., 1995).”
MethodKlous, M., & Klous, S. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4001396 · Cited by 16
A Model for the Evaluation of Lower Extremity Kinematics with Integrated Multisegmental Foot Motion
Long, J. T., Wang, M., & Harris, G. F. (2011) · Journal of Experimental & Clinical Medicine · doi:10.1016/j.jecm.2011.09.009 · Cited by 15
“Reduced correlations observed at the hip joint are largest in magnitude and most significant in the coronal plane; these agree with previous findings 9, 10, 12 which demonstrate that a functionally determined HJC falls lateral to an anthropometrically predicted HJC.”
Robustness of kinematic weighting and scaling concepts for musculoskeletal simulation
Schellenberg, F., Taylor, W. R., Jonkers, I., & Lorenzetti, S. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1295305 · Cited by 14
“…squats analysed by schütz and co-workers (2014), and demonstrate that in certain cases, the error is as large as the measured values. and 16 mm (Leardini et al. 1999; Hicks & Richards 2005; Cereatti et al. 2009; Sangeux et al. 2011) for approaches that also included functional joint centres,…”
BackgroundCarman, L., Besier, T. F., & Choisne, J. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111265 · Cited by 13
Development of an Optimization Method for Locating the Pelvis in an Automobile Seat
Park, J., Ebert, S. M., Reed, M. P., & Hallman, J. J. (2015) · Procedia Manufacturing · doi:10.1016/j.promfg.2015.07.811 · Cited by 13
Human hip joint center analysis for biomechanical design of a hip joint exoskeleton
Yang, W., Yang, C.-J., & Xu, T. (2016) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/fitee.1500286 · Cited by 13
“In a pelvic anatomical coordinate system, the motions of the HJC have been estimated previously using a functional method applied by calculating the center of the best sphere described by the trajectory of markers placed on the thigh during several trials of hip rotation (Leardini et al., 1999).”
MethodResultInfluentialAssessment of deep learning pose estimates for sports collision tracking
Blythman, R., Saxena, M., Tierney, G. J., Richter, C., Smolić, A., & Simms, C. K. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2117474 · Cited by 15
“Several works (Hicks & Richards, 2005; Leardini et al., 1999) have found the Davis equations (Davis et al.”
BackgroundMethodIntraoperative passive knee kinematics during total knee arthroplasty surgery
Young‐Shand, K. L., Dunbar, M., Richardson, G. C., & Wilson, J. L. A. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.22945 · Cited by 12
“A hip circumduction exercise with no rocking of the pelvis was used to define the hip joint center.(21) After anatomical point digitization, the surgeon brought the leg through a standardized series of passive flexion and extension cycles at two time points during surgery (i) prior to osteophyte removal or any bone re…”
MethodHip Joint Centre Localization: Evaluation of Formal Methods and Effects on Joint Kinematics
Żuk, M., Świątek‐Najwer, E., & Pezowicz, C. A. (2014) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-06596-0_6 · Cited by 12
“Although, choice of appropriate approach among functional methods, seems to remain unresolved, in general functional methods perform better than predictive methods [6,11].”
BackgroundMethodInfluentialVariations of Marker Sets and Models for Standard Gait Analysis
Stief, F. (2016) · Springer eBooks · doi:10.1007/978-3-319-30808-1_26-1 · Cited by 13
Three-dimensional gait analysis
Kirtley, C. (2006) · Elsevier eBooks · doi:10.1016/b978-0-443-10009-3.50007-2 · Cited by 12
Ektas, N., Scholes, C. J., Ruiz, A. M., & Ireland, J. T. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-037126 · Cited by 13
Three-Dimensional Reconstruction of the Human Skeleton in Motion
Camomilla, V., Cappozzo, A., & Vannozzi, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-14418-4_146 · Cited by 14
Self-citationA procedure for estimating the relevant forces in the human knee using a four-bar mechanism
Farhat, N., Mata, V., Rosa, D., & Sancho, J. F. (2010) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840903352540 · Cited by 12
“However, this method corresponds to higher error levels (Leardini et al. 1999).”
An optimal control solution to the predictive dynamics of cycling
Zignoli, A., Biral, F., Pellegrini, B., Jinha, A., Herzog, W., & Schena, F. F. (2017) · Sport Sciences for Health · doi:10.1007/s11332-017-0370-9 · Cited by 14
“In a pilot study, it was concluded that there were no determinant losses in accuracy with reference to other accurate methods for HJC estimation by means of motion analysis [26, 35].”
MethodLura, D. J. (2012) · Digital Commons - University of South Florida (University of South Florida) · Cited by 12
Hu, C., Lu, T., & Chen, S. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-20 · Cited by 11
“hip was estimated using a functional method [38].”
MethodPhillips, T., Brierty, A., Goodchild, D., Patritti, B. L., Murphy, A., Boocock, M., Dwan, L. N., Passmore, E., McGrath, M., & Edwards, J. (2023) · Gait & Posture · doi:10.1016/j.gaitpost.2023.07.001 · Cited by 11
Kang, M., Sadri, H., STERN, R. E., Magnenat‐Thalmann, N., Hoffmeyer, P. J., & Ji, H.-M. (2010) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.495064 · Cited by 11
“…located by predictive methods (Andriacchi et al. 1980; Tylkowski et al. 1982; Bell et al. 1990; Davis et al. 1991; Seidel et al. 1995; Kirkwood et al. 1999) or functional methods (Cappozzo 1984; Shea et al. 1997; Leardini et al. 1999; Marin et al. 2003; Piazza et al. 2004; Cereatti et al. 2007).”
MethodPredicting the lumbosacral joint centre location from palpable anatomical landmarks
Murphy, A. J., Bull, A. M. J., & McGregor, A. H. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411911416859 · Cited by 11
Andrzejewski, K., Domżalski, M. E., Komorowski, P., Poszepczyński, J., Rokita, B., & Elgalal, M. T. (2023) · Diagnostics · doi:10.3390/diagnostics13152516 · Cited by 10
Rosario, H. D., Page, A. F., & Mata, V. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.02.003 · Cited by 10
“The subject made five consecutive cycles of typical functional calibration gestures: arm flexion–extension, elevation, and half-circumduction, with a maximum elevation of 451 (Leardini et al., 1999).”
BackgroundRouhandeh, A., Joslin, C., Qu, Z., & Ono, Y. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944585 · Cited by 11
“In human movement analysis, the hip joint is generally considered as a ball-and-socket joint and the hip joint center (HJC) location can be determined using two general approaches: predictive methods and functional methods [1, 2].”
MethodDetecting Anatomical Leg Length Discrepancy Using the Plug-in-Gait Model
Khamis, S., Danino, B., Springer, S., Ovadia, D., & Carmeli, E. (2017) · Applied Sciences · doi:10.3390/app7090926 · Cited by 10
“Leardini reported similar results found in a sample of 11 male adult able-bodied volunteers, where the HJC estimation was at a distance of 29 ± 8 mm of a measurement obtained by a roentgen stereophotogrammetric analysis [27].”
ResultLee, W.-C., Chen, T., Hung, L., Wang, T., Chang, C., & Lu, T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.704266 · Cited by 10
A bounded iterative closest point method for minimally invasive registration of the femur
y Baena, F. R., Hawke, T., & Jakopec, M. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913500948 · Cited by 10
“For the bounded method, the hip centre was estimated for each registration using the functional method described in (26) with an average of 400 points.”
MethodVariations of Marker Sets and Models for Standard Gait Analysis
Stief, F. (2018) · Springer eBooks · doi:10.1007/978-3-319-14418-4_26 · Cited by 17
Jabbar, K. B. A., Kudo, S., Goh, K. W., & Goh, M. R. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.05.021 · Cited by 10
Scholes, C. J., Fatima, M., Schwägli, T., & Liu, D. (2024) · Arthroplasty · doi:10.1186/s42836-023-00224-0 · Cited by 9
“The COR was identified by the functional method [16], with the thigh moved through a multiplanar range of motion while the tags were tracked with the handheld camera.”
MethodO’Connor, J. D., Rutherford, M., Bennett, D., Hill, J., Beverland, D., Dunne, N., & Lennon, A. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.07.033 · Cited by 11
New equations to calculate 3D joint centres in the lower extremities
Sandau, M., Heimbürger, R. V., Villa, C., Jensen, K. E., Moeslund, T. B., Aanæs, H., Alkjær, T., & Simonsen, E. B. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.07.001 · Cited by 9
Itoh, H., Takiguchi, K., Shibata, Y., Okubo, S., Yoshiya, S., & Kuroda, R. (2016) · Journal of Physical Therapy Science · doi:10.1589/jpts.28.2461 · Cited by 11
SINCLAIR, J. K., & Bottoms, L. M. (2018) · Human Movement · doi:10.2478/humo-2013-0028 · Cited by 11
“To define the functional HJC, participants performed five sequential flexion-extension and abduction-adduction movements of the right hip at a self-selected velocity followed by a cycle of full hip circumduction [8].”
BackgroundMethodOptimization approach for the simulation of car accessibility movement
Lempereur, M., Pudlo, P., Gorce, P., & Lepoutre, F.-X. (2004) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2003.1243920 · Cited by 9
“Wrist is defined in the middle of the joint [3] whereas the hip and the shoulder center are estimated with the functional method [ 16 ].”
MethodAudenaert, E. A., Vigneron, L. M., Hoof, T. V., D'Herde, K. G. M. A., Maele, G. V., Oosterlinck, D., & Pattyn, C. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0804-5 · Cited by 8
“Subject-specific HJC coordinates in the anatomical pelvic sensor frame can be estimated using either a functional or a prediction approach [ 16 ].”
MethodInfluentialSegment-embedded frame definition affects the hip joint centre precision during walking
Roosen, A., Pain, M. T. G., Thouzé, A., Monnet, T., & Begon, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.03.013 · Cited by 8
Roosen, A., Pain, M. T. G., & Begon, M. (2009) · Journal of Applied Biomechanics · doi:10.1123/jab.25.4.281 · Cited by 8
“Leardini et al. (1999) found that their functional method approximated the real JC obtained through roentgen stereophotogrammetric analysis better than predictive methods, 13 mm rather than 25 mm (Bell et al., 1990).”
MethodHip joint centre localisation with an unscented Kalman filter
Momi, E. D., Beretta, E., & Ferrigno, G. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.670852 · Cited by 8
“In tests performed on living humans, the true HJC localisation can be measured (Leardini et al. 1999), if, for example, US images of the subject are acquired (Hicks and Richards 2005), or unknown (Piazza et al.”
BackgroundThe Accuracy of the Use of Functional Hip Motions on Localization of the Center of the Hip
Speirs, A., Benoit, D. L., Beaulieu, M. L., Lamontagne, M., & Beaulé, P. E. (2012) · HSS Journal® The Musculoskeletal Journal of Hospital for Special Surgery · doi:10.1007/s11420-012-9296-6 · Cited by 8
“Regression equations, also known as the predictive technique, are often used in motion analysis studies, but are less accurate than functional methods in estimating the joint center [11, 13].”
BackgroundMethodResultInfluentialThree-Dimensional Reconstruction of the Human Skeleton in Motion
Camomilla, V., Cappozzo, A., & Vannozzi, G. (2017) · Springer eBooks · doi:10.1007/978-3-319-30808-1_146-1 · Cited by 9
Self-citationRoda, R., Wilson, J. L. A., Wilson, D. A. J., Richardson, G. C., & Dunbar, M. (2012) · The Journal of Arthroplasty · doi:10.1016/j.arth.2012.02.009 · Cited by 8
“To mathematically determine the functional hip joint center, the surgeon circumducted the femur about the hip joint [15].”
BackgroundHip joint center location by fitting conchoid shape to the acetabular rim region of MR images
Kang, M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404244 · Cited by 8
Loading rates during walking in adolescents with type II osteonecrosis secondary to pelvic osteotomy
Wang, T., Wu, K., Chen, C., Hong, S., Lu, T., Kuo, K. N., & Sc, H. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23239 · Cited by 7
Arumugam, A., Markström, J. L., & Häger, C. K. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109480 · Cited by 7
“A standing trial was recorded to define the segmental coordinate system, with hip joint centers defined from hip circumduction movement (Leardini et al., 1999) and knee joint centers defined from the markers on the femoral epicondyles.”
Bakke, D., & Besier, T. F. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111086 · Cited by 8
Characteristics of the Shrug Motion and Trapezius Muscle Activity During the Power Clean
Nagao, H., & Ishii, Y. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003355 · Cited by 6
Ultrasound and Mocap to improve non invasive hip joint center calculation
Upadhyaya, S., Lee, W., & Joslin, C. (2015) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2015.7145253 · Cited by 6
Possibilities of texture based motion analysis
Holmberg, B., & Lanshammar, H. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.06.010 · Cited by 6
“[14] when applied to subjects that do not conform to the statistics.”
BackgroundMethodInfluentialOlmedo-Garcia, N., & Sevilla, A. (2010) · Hip International · doi:10.1177/11207000100200s709 · Cited by 6
“Several methods have been described (5-14) as helpful for determining the premorbid rotation centre when the changes are bilateral.”
MethodMcGibbon, C. A., Fowler, J., Chase, S., Steeves, K., Landry, J. P., & Mohamed, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4032054 · Cited by 6
King, S., Vanicek, N., & O’Brien, T. D. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.03.029 · Cited by 6
“Functional movements were used to define the hip joint centre [31].”
MethodOutcomes of anterior cruciate ligament reconstruction
Irismetov, M., Махамаджонович, У. Ф., Файзахматович, Ш. Д., Холиков, А. М., Ражабов, К. Н., & Tadzhinazarov, M. B. (2019) · Genij Ortopedii · doi:10.18019/1028-4427-2019-25-3-285-289 · Cited by 7
Fan, L., Copple, T. J., Tritsch, A. J., & Shultz, S. J. (2014) · Journal of Athletic Training · doi:10.4085/1062-6050-49.3.86 · Cited by 6
Sensitivity analysis of hip joint centre estimation based on three-dimensional CT scans
Bartels, W., Sloten, J. V., & Jonkers, I. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.548323 · Cited by 5
“Unfortunately, most studies that aim to locate the HJC in medical images do not report the method by which points on the femoral head are located (Sugano et al. 1998; Leardini et al. 1999; Mahaisavariya et al. 2002; Harrington et al. 2007; Gilles et al. 2009), or do not explain why a particular method was chosen (Kim…”
BackgroundMethodInfluentialBennett, H. J., Valenzuela, K. A., Fleenor, K., & Weinhandl, J. T. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4044503 · Cited by 6
Identification of alternative movement techniques during the car entering movement
Lempereur, M., Pudlo, P., Gorce, P., & Lepoutre, F.-X. (2006) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2005.1571739 · Cited by 5
“The joint center of the hip and the shoulder are estimated with the functional method [10].”
MethodPelvic tracker effects on hip center accuracy using imageless navigation
Mihalko, W. M., Phillips, M. J., Fishkin, Z., & Krackow, K. A. (2006) · Computer Aided Surgery · doi:10.3109/10929080600942147 · Cited by 5
“The larger errors observed in the RSA study could be attributed to decreased accuracy of the RSA technique, as compared with CT, in determining the true HJC.”
MethodResultInfluentialDebril, J.-F., Menceur, M. O. A. E., Pudlo, P., Lepoutre, F.-X., & Gorce, P. (2007) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2007-01-2462 · Cited by 5
Ravera, E. P., & Peterson, V. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110810 · Cited by 4
Ishii, H., Nagano, Y., Ida, H., Fukubayashi, T., & Maruyama, T. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.001 · Cited by 4
Validation of Functional Methods for Calculating Shoulder Joint Centers Using 3D Motion Analysis
Lura, D. J., Carey, S. L., & Dubey, R. V. (2010) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2010-40386 · Cited by 4
Analysis of Successful Landing by the Type of the Salto Backward
Han, Y.-S. (2004) · Korean Journal of Sport Biomechanics · doi:10.5103/kjsb.2004.14.1.001 · Cited by 4
Leg length measurement: clinical versus mathematical modelling
Ashford, R. L., & Shippen, J. M. (2003) · The Foot · doi:10.1016/s0958-2592(03)00039-7 · Cited by 6
“Functional methods use the movement associated with a joint to calculate properties of the joint [12].”
MethodAnalysis of Heel Raise Exercise with Three Foot Positions
Arnsdorff, K., Limbaugh, K., & Riemann, B. L. (2011) · International journal of exercise science · doi:10.70252/ypic8188 · Cited by 4
“The hip joint center was established using a series of five points along a circumduction cycle for each hip to estimate the apex of femoral motion (9).”
MethodSchmitz, R. J., Sauret, J. J., & Shultz, S. J. (2013) · The Knee · doi:10.1016/j.knee.2013.04.017 · Cited by 4
“Joint centers were determined using rotation [32] (hip) and centroid [33] (knee and ankle) methods.”
MethodMenceur, M. O. A. E., Pudlo, P., Gorce, P., & Lepoutre, F.-X. (2015) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2015.01.014 · Cited by 4
Baker, R. J. (2012) · CRC Press eBooks · doi:10.1201/b13733-19 · Cited by 6
Accuracy of Computer-Assisted Surgery
Leardini, A., Belvedere, C., Ensini, A., Dedda, V., & Giannini, S. (2012) · Springer eBooks · doi:10.1007/978-3-642-31430-8_2 · Cited by 5
Self-citationKinematic study of a reconstructed hip in paediatric oncology
Taddei, F., Stagni, R., Cappello, A., Manfrini, M., Albisinni, U., & Viceconti, M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345129 · Cited by 4
Sangeux, M., Peters, A., & Baker, R. J. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.06.007 · Cited by 4
Yeo, H.-C., & Ryu, J. (2004) · Korean Journal of Sport Biomechanics · doi:10.5103/kjsb.2004.14.1.013 · Cited by 4
Göll, F., Braunstein, B., Stemmler, M., Fasse, A., Abel, D., & Albracht, K. (2025) · PLoS ONE · doi:10.1371/journal.pone.0324985 · Cited by 3
Automatic Generation of a Subject Specific Upper Body Model From Motion Data
Lura, D. J., Carey, S. L., & Dubey, R. V. (2011) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2011-63953 · Cited by 3
“Functional methods, those relying on the path data from motion analysis of a subject, for determining the location of joints within a system have several advantages over traditional regressive methods [6].”
MethodComparing hip joint centre location methods in an automotive driving position
Bulle, J., Beurier, G., Wang, X., & Compigne, S. (2012) · International Journal of Human Factors Modelling and Simulation · doi:10.1504/ijhfms.2012.051561 · Cited by 3
A functional method for generating individualized spine models from motion-capture data
Seko, S., Matthew, R. P., Bajcsy, R. K., & Lotz, J. C. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512580 · Cited by 3
“These methods are well suited for the recovery of joints with a large range of motion that can be appropriately simplified to a spherical or cylindrical surface such as the hip [6], [7] and glenohumeral rotation of the shoulder [8].”
MethodResultGOLF SWING VARIABILITY IN ELITE FEMALE JUNIOR GOLFERS
Gryc, T., Marenčáková, J., Brožka, M., & Zahálka, F. (2020) · Lékař a technika - Clinician and Technology · doi:10.14311/ctj.2019.3.03 · Cited by 3
Silva, R. L. E., Maia, D. F. M., de Oliveira, R. R., & Silva, R. S. (2021) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2021.02.006 · Cited by 3
Picot, B., Falcoz, E., Rémy‐Néris, O., Guégan, C., & Lempereur, M. (2022) · Science & Sports · doi:10.1016/j.scispo.2021.09.002 · Cited by 3
Metadata
- Authors
- Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S.
- Affiliations
- Istituto Ortopedico Rizzoli (IT)
- University of Sassari (IT)
- Corresponding author
- Leardini, Alberto
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 32
- Issue
- 1
- Pages
- 99-103
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2140047417
- Cited by
- 415
- References
- 20
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 5 · 2023: 6 · 2022: 7 · 2021: 8 · 2020: 11 · 2019: 10 · 2018: 14 · 2017: 17 · 2016: 20 · 2015: 23 · 2014: 29 · 2013: 31 · 2012: 34
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Health Sciences › Medicine › Surgery › Hip disorders and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- functional methods, marker trajectories, sphere fitting, regression equations, anthropometry, roentgen stereophotogrammetric analysis, hip range of motion, motion analysis
- MeSH terms
- Adult, Anthropometry, Biomechanical Phenomena, Evaluation Studies as Topic, Forecasting, Hip Joint, Humans, Male, Models, Anatomic, Photogrammetry, Radiography, Regression Analysis, Rotation, Thigh
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.