The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques
The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Abstract
Acoustic microscopy (30-60 microm resolution) and nanoindentation (1-5 microm resolution) are techniques that can be used to evaluate the elastic properties of human bone at a microstructural level. The goals of the current study were (1) to measure and compare the Young's moduli of trabecular and cortical bone tissues from a common human donor, and (2) to compare the Young's moduli of bone tissue measured using acoustic microscopy to those measured using nanoindentation. The Young's modulus of cortical bone in the longitudinal direction was about 40% greater than (p<0.01) the Young's modulus in the transverse direction. The Young's modulus of trabecular bone tissue was slightly higher than the transverse Young's modulus of cortical bone, but substantially lower than the longitudinal Young's modulus of cortical bone. These findings were consistent for both measurement methods and suggest that elasticity of trabecular tissue is within the range of that of cortical bone tissue. The calculation of Young's modulus using nanoindentation assumes that the material is elastically isotropic. The current results, i.e., the average anisotropy ratio (E(L)/E(T)) for cortical bone determined by nanoindentation was similar to that determined by the acoustic microscope, suggest that this assumption does not limit nanoindentation as a technique for measurement of Young's modulus in anisotropic bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [138]
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
Self-citationA method for interpreting the data from depth-sensing indentation instruments
Doerner, M. F., & Nix, W. D. (1986) · Journal of Materials Research · doi:10.1557/jmr.1986.0601 · Cited by 2,863
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Self-citationMeasurement of Thin Film Mechanical Properties Using Nanoindentation
Pharr, G. M., & Oliver, W. C. (1992) · MRS Bulletin · doi:10.1557/s0883769400041634 · Cited by 1,012
Self-citationElastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Self-citationA continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citationComposition of trabecular and cortical bone
Gong, J. K., Arnold, J. S., & Cohn, S. H. (1964) · The Anatomical Record · doi:10.1002/ar.1091490303 · Cited by 308
Yoon, H. S., & Lawrence Katz, J. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90089-0 · Cited by 254
Buckling studies of single human trabeculae
Townsend, P. R., Rose, R. M., & Radin, E. L. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90025-1 · Cited by 192
Comparison of the trabecular and cortical tissue moduli from human iliac crests
Kuhn, J. L., Goldstein, S. A., Choi, R., London, M., Feldkamp, L. A., & Matthews, L. S. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070614 · Cited by 164
The anisotropy of osteonal bone and its ultrastructural implications
Turner, C. H., Chandran, A., & Pidaparti, R. M. V. (1995) · Bone · doi:10.1016/8756-3282(95)00148-7 · Cited by 161
Self-citationTensile testing of rodlike trabeculae excised from bovine femoral bone
Ryan, S. D., & Williams, J. L. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90049-3 · Cited by 118
Elastic Anisotropy of ß‐Silicon Nitride Whiskers
Hay, J. C., Sun, E. Y., Pharr, G. M., Becher, P., & Alexander, K. B. (1998) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1998.tb02674.x · Cited by 97
Self-citationScanning Acoustic Microscope Studies of the Elastic Properties of Osteons and Osteon Lamellae
Katz, J. L., & Meunier, A. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895537 · Cited by 96
Elastic Properties of Osteoporotic Bone Measured by Scanning Acoustic Microscopy
Hasegawa, K., Turner, C. H., Recker, R. R., Wu, E. X., & Burr, D. B. (1995) · Bone · doi:10.1016/8756-3282(95)80016-j · Cited by 92
Self-citationWilliams, J. L., & Johnson, W. J. H. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90017-1 · Cited by 80
Experimental method for the measurement of the elastic modulus of trabecular bone tissue
Mente, P. L., & Lewis, J. L. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070320 · Cited by 79
Is Trabecular Bone Tissue Different from Cortical Bone Tissue
Edward, G. X., & Goldstein, S. A. (1998) · Forma · Cited by 74
Takano, Y., Turner, C. H., & Burr, D. B. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110914 · Cited by 58
Self-citationThe acoustic properties of normal and imbedded bovine bone as measured by acoustic microscopy
Zimmerman, M. C., Prabhakar, A., Chokshi, B. V., Budhwani, N., & Berndt, H. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280812 · Cited by 31
Runkle, J. C., & Pugh, J. (1975) · PubMed · Cited by 31
The Application of Scanning Acoustic Microscopy in a Bone Remodeling Study
Shieh, S., Zimmerman, M. C., & Langrana, N. A. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2794183 · Cited by 15
Elastic anisotropy of {beta}-silicon nitride whiskers
Hay, J. C., Sun, E. Y., Becher, P., et al. (1998) · Journal of the American Ceramic Society · Cited by 5
Research works printed but not linked: 2
- Ko, C.C., Douglas, W.H., Cheng, Y.S., 1995. Intrinsic mechanical competence of cortical and trabecular bone measured by nanoindentation and microindentation probes. 1995 ASME Bioengineering Conference, ASME BED-Vol. 29, pp. 415–416.
- Runkle, 1975, The micro-mechanics of cancellous bone, Bulletin of the Hospital for Joint Diseases, 36, 2
Cited by
Structure and mechanical quality of the collagen–mineral nano-composite in bone
Fratzl, P., Gupta, H. S., Paschalis, E. P., & Roschger, P. (2004) · J. Mater. Chem. · doi:10.1039/b402005g · Cited by 1,222
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
Woodard, J. R., Hilldore, A. J., Lan, S. K., Park, C. J., Morgan, A. W., Eurell, J. A. C., Clark, S. G., Wheeler, M. B., Jamison, R. D., & Wagoner Johnson, A. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.021 · Cited by 829
Metadata
- Authors
- Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M.
- Affiliations
- Indiana University School of Medicine (US)
- University of Memphis (US)
- Indiana University (US)
- Rice University (US)
- Corresponding author
- Turner, Charles H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 32
- Issue
- 4
- Pages
- 437-441
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2045985308
- Cited by
- 547
- References
- 27
- Citations by year
- 2026: 11 · 2025: 9 · 2024: 14 · 2023: 8 · 2022: 11 · 2021: 18 · 2020: 21 · 2019: 19 · 2018: 20 · 2017: 15 · 2016: 17 · 2015: 29 · 2014: 36 · 2013: 21 · 2012: 34
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Energy
- Lockheed Martin
- Oak Ridge Associated Universities
- National Institutes of Health (5r01de011291-02)
- U.S. Public Health Service
- National Institute of Dental and Craniofacial Research (DE11291)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Mechanics of Materials › Metal and Thin Film Mechanics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Keywords
- trabecular bone, cortical bone, Young's modulus, elastic properties, acoustic microscopy, nanoindentation, anisotropy, anisotropy ratio, bone microarchitecture
- MeSH terms
- Aged, Algorithms, Elasticity, Femur, Hardness, Humans, Male, Microscopy, Stress, Mechanical, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.