CoChat

Clinical evaluation of the macroduct sweat collection system and conductivity analyzer in the diagnosis of cystic fibrosis

Hammond, Keith B., Turcios, Nelson L., Gibson, Lewis E. · 1994 · The Journal of Pediatrics

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

The purposes of this study were to compare sweat tests used in diagnosing cystic fibrosis (CF), as performed with the Macroduct collection system, with those utilizing the more laborious quantitative pilocarpine iontophoresis test (QPIT), and to ascertain the efficacy of the Sweat-Chek conductivity analyzer in eliminating some possibly unnecessary chloride analyses. A Macroduct sweat test was performed on one arm and a QPIT on the other on 1090 patients, 93 of whom had CF. Of these, 514 patients (43 with CF) also had a conductivity determination on the Macroduct sweat sample. All subjects were referred to the laboratory of one of us (K.B.H.) for sweat testing. Of the QPIT samples, 0.7% were inadequate, as were 6.1% of those from the Macroduct system. When sodium and chloride concentrations from the two tests were compared, the standard errors of the estimate were 3.90 and 3.85, respectively. Agreement within 8 mEq/L could then be expected with 95% confidence limits. With use of the Sweat-Chek analyzer, no patient with CF was found to have a conductivity of less than 90 mmol/L, whereas 430 (91%) of the non-CF subjects had a conductivity of less than 50 mmol/L. None of those 430 subjects had a sweat chloride value > 32 mmol/L. We conclude that the Macroduct collection system provides results equally as satisfactory as those provided by the QPIT and that the Sweat-Chek analyzer frequently eliminates the necessity of measuring chloride concentrations.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0022-3476(94)70314-0

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Research works printed but not linked: 2

  1. Rosenstein, 1982, Sweat testing in CF: not to be taken lightly, J Respir Dis, 3, 71
  2. Hammond, 1988, An evaluation of the Wescor Sweat-Chek conductivity analyzer [Abstract], Pediatr Pulmonol, 162, 139

Cited by

See all 178

Metadata

Authors
Hammond, K. B., Turcios, N. L., & Gibson, L. E.
Affiliations
University of Colorado Anschutz (US)
Venue
The Journal of Pediatrics
Publisher
Elsevier BV
Published
1994-02
Volume
124
Issue
2
Pages
255-260
ISSN
0022-3476 (ISSN-L)
OpenAlex
W2074840452
Cited by
178
References
10
Citations by year
2026: 3 · 2025: 4 · 2024: 12 · 2023: 9 · 2022: 7 · 2021: 13 · 2020: 7 · 2019: 3 · 2018: 8 · 2017: 9 · 2016: 3 · 2015: 8 · 2014: 12 · 2013: 4 · 2012: 9
FWCI
2.12
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • The Journal of Pediatrics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cystic Fibrosis Research Advances
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Physiology (medical) › Salivary Gland Disorders and Functions
Keywords
cystic fibrosis, sweat test, sweat conductivity, sweat chloride, sweat sodium
MeSH terms
Adolescent, Adult, Aged, Child, Child, Preschool, Chlorides, Cystic Fibrosis, Electric Conductivity, Humans, Infant, Infant, Newborn, Middle Aged, Osmolar Concentration, Potassium, Sodium, Specimen Handling, Sweat, Case-Control Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical evaluation of the macroduct sweat collection system and conductivity analyzer in the diagnosis of cystic fibrosis. https://app.cochat.ai/papers/10.1016/s0022-3476(94)70314-0
The paper
Hammond, K. B., Turcios, N. L., & Gibson, L. E. (1994). Clinical evaluation of the macroduct sweat collection system and conductivity analyzer in the diagnosis of cystic fibrosis. The Journal of Pediatrics. https://doi.org/10.1016/s0022-3476(94)70314-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.