Clinical evaluation of the macroduct sweat collection system and conductivity analyzer in the diagnosis of cystic fibrosis
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The purposes of this study were to compare sweat tests used in diagnosing cystic fibrosis (CF), as performed with the Macroduct collection system, with those utilizing the more laborious quantitative pilocarpine iontophoresis test (QPIT), and to ascertain the efficacy of the Sweat-Chek conductivity analyzer in eliminating some possibly unnecessary chloride analyses. A Macroduct sweat test was performed on one arm and a QPIT on the other on 1090 patients, 93 of whom had CF. Of these, 514 patients (43 with CF) also had a conductivity determination on the Macroduct sweat sample. All subjects were referred to the laboratory of one of us (K.B.H.) for sweat testing. Of the QPIT samples, 0.7% were inadequate, as were 6.1% of those from the Macroduct system. When sodium and chloride concentrations from the two tests were compared, the standard errors of the estimate were 3.90 and 3.85, respectively. Agreement within 8 mEq/L could then be expected with 95% confidence limits. With use of the Sweat-Chek analyzer, no patient with CF was found to have a conductivity of less than 90 mmol/L, whereas 430 (91%) of the non-CF subjects had a conductivity of less than 50 mmol/L. None of those 430 subjects had a sweat chloride value > 32 mmol/L. We conclude that the Macroduct collection system provides results equally as satisfactory as those provided by the QPIT and that the Sweat-Chek analyzer frequently eliminates the necessity of measuring chloride concentrations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While normative data are available for Na+ and Cl− (Barnes et al. 2019; Hammond et al. 1994; Wescor 2005), there are insufficient studies to identify reference ranges for other sweat constituents.”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Hammond et al. 1994
Citations
Cites
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434
Self-citationA SIMPLE AND ACCURATE METHOD FOR THE DETERMINATION OF CHLORIDE IN BIOLOGICAL FLUIDS
Schales, O., & Schales, S. S. (1941) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)72872-x · Cited by 1,129
Forstner, G. (1985) · Gastroenterology · doi:10.1016/0016-5085(85)90777-2 · Cited by 147
Fluid and Electrolyte Abnormalities in Exocrine Glands in Cystic Fibrosis
Beck, F. X. (1983) · Journal of Anatomy · Cited by 84
Cooperative Study Comparing Three Methods of Performing Sweat Tests to Diagnose Cystic Fibrosis
Denning, C. R., Huang, N. Ν., Laraya-Cuasay, L. R., Shwachman, H., Tocci, P. M., Warwick, W. J., & Gibson, L. E. (1980) · PEDIATRICS · doi:10.1542/peds.66.5.752 · Cited by 64
Self-citationBook Review: Cystic Fibrosis: Horizons
Super, M. (1985) · Journal of the Royal Society of Medicine · doi:10.1177/014107688507800829 · Cited by 50
Improved sweat test method for the diagnosis of cystic fibrosis.
Carter, E. P., Barrett, A. D. T., Heeley, A. F., & Kuzemko, J. A. (1984) · Archives of Disease in Childhood · doi:10.1136/adc.59.10.919 · Cited by 47
Measurement of the Electrical Conductivity of Sweat
Licht, T. S., Stern, M., & Shwachman, H. (1957) · Clinical Chemistry · doi:10.1093/clinchem/3.1.37 · Cited by 47
Licht, T. S., Stern, M., & Shwachman, H. (1957) · PubMed · Cited by 35
Gibson, L. E. (1973) · Clinical Pediatrics · doi:10.1177/000992287301200817 · Cited by 21
Self-citation
Research works printed but not linked: 2
- Rosenstein, 1982, Sweat testing in CF: not to be taken lightly, J Respir Dis, 3, 71
- Hammond, 1988, An evaluation of the Wescor Sweat-Chek conductivity analyzer [Abstract], Pediatr Pulmonol, 162, 139
Cited by
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 764
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J. (2018) · Advanced Science · doi:10.1002/advs.201800880 · Cited by 526
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., et al. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00961 · Cited by 446
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
“Collection of sweat samples most typically relies on absorbent pads or plastic microtubes (Macroduct Sweat Collection System) strapped to the skin and using traditional laboratory instruments for chemical evaluation (23).”
MethodThe diagnosis and management of sinusitis: A practice parameter update
Slavin, R. G., Spector, S. L., Bernstein, I. L., Slavin, R. G., Kaliner, M. A., Kennedy, D. W., Virant, F. S., Wald, E. R., Khan, D. A., Blessing-Moore, J., et al. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.09.048 · Cited by 378
“A sweat test should be performed in any child with nasal polyps or any patient with chronic colonization of the nose-sinuses with Pseudomonas species/B capacia.(181,182) When results are equivocal, the diagnosis can be clarified by means of DNA analysis for known genetic mutations.”
BackgroundPhysiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601355 · Cited by 315
Diagnostic Sweat Testing: The Cystic Fibrosis Foundation Guidelines
LeGrys, V. A., Yankaskas, J. R., Quittell, L. M., Marshall, B. C., & Mogayzel, P. J. (2007) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2007.03.002 · Cited by 310
Wearable electrochemical biosensors in North America
Min, J., Sempionatto, J. R., Teymourian, H., Wang, J., & Gao, W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112750 · Cited by 278
“stimulation module, and a fluidic sweat collector wristband module (Hammond et al., 1994).”
Corrie, S. R., Coffey, J. W., Islam, J., Markey, K. A., & Kendall, M. A. F. (2015) · The Analyst · doi:10.1039/c5an00464k · Cited by 211
Zhong, B., Jiang, K., Wang, L., & Shen, G. (2022) · Advanced Science · doi:10.1002/advs.202103257 · Cited by 164
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
“Wearable conductivity sensors are readily miniaturized [204], but are not chloride specific [205].”
BackgroundSweat testing for the diagnosis of cystic fibrosis: Practical considerations
LeGrys, V. A. (1996) · The Journal of Pediatrics · doi:10.1016/s0022-3476(96)70034-3 · Cited by 141
Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management
Ray, T. R., Ivanovic, M., Curtis, P. M., Franklin, D., Guventurk, K., Jeang, W. J., Chafetz, J., Gaertner, H., Young, G., Rebollo, S., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abd8109 · Cited by 134
“13, eabd8109 (2021) 31 March 2021 2 of 13 sweat collection: (i) the traditional Gibson-Cooke method, introduced in 1959, that uses gauze pads (18); and (ii) a more modern technique, introduced in 1986, that relies on coiled tubes in plastic housings (Macroduct Sweat Collection System; MSCS, ELITechGroup) (19).”
MethodNormative data for regional sweat sodium concentration and whole-body sweating rate in athletes
Baker, L. B., Barnes, K. A., Anderson, M. L., Passe, D. H., & Stofan, J. R. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1055291 · Cited by 133
Can Wearable Sweat Lactate Sensors Contribute to Sports Physiology?
Hoovels, K. V., Xuan, X., Cuartero, M., Gijssel, M., Swarén, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01403 · Cited by 143
Inconclusive Diagnosis of Cystic Fibrosis After Newborn Screening
Ooi, C. Y., Castellani, C., Keenan, K., Avolio, J., Volpi, S., Boland, M., Kovesi, T., Bjornson, C., Chilvers, M. A., Morgan, L., et al. (2015) · PEDIATRICS · doi:10.1542/peds.2014-2081 · Cited by 128
Recent Advances in Electrochemical Sensors for Wearable Sweat Monitoring: A Review
Yeung, K. K., Huang, T., Hua, Y., Zhang, K., Yuen, M. M. F., & Gao, Z. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3074311 · Cited by 134
The relevance of sweat testing for the diagnosis of cystic fibrosis in the genomic era.
Mishra, A., Greaves, R. F., & Massie, J. (2005) · Europe PMC (PubMed Central) · Cited by 294
Batheja, P., Thakur, R., & Michniak‐Kohn, B. B. (2005) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.3.1.127 · Cited by 119
“Sweat collection in the diagnosis of cystic fibrosis Sweat collection for cystic fibrosis diagnosis in neonates Both systems use Pilogel® (pilocarpine) iontophoretic discs for sweat induction [78]”
MethodParameters for the Diagnosis and Management of Sinusitus
Spector, S. L., Bernstein, I. L., Li, J. T. C., Berger, W. E., Kaliner, M., Schuller, D. E., Blessing-Moore, J., Dykewicz, M. S., Fìneman, S. M., Lee, R. E., et al. (1998) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(98)70045-4 · Cited by 131
TiO2 Nanotubes Alginate Hydrogel Scaffold for Rapid Sensing of Sweat Biomarkers: Lactate and Glucose
Gunatilake, U. B., García-Rey, S., Ojeda, E., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c11446 · Cited by 113
β-Adrenergic Sweat Secretion as a Diagnostic Test for Cystic Fibrosis
Quinton, P., Molyneux, L., Ip, W., Dupuis, A., Avolio, J., Tullis, E. D., Conrad, D. J., Shamsuddin, A. K. M., Durie, P. R., & Gonska, T. Y. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201205-0922oc · Cited by 113
Diagnosis and Treatment of Cystic Fibrosis
Koch, C., & Høiby, N. (2000) · Respiration · doi:10.1159/000029503 · Cited by 96
“has been replaced by a specially designed macroduct sweat collection system either followed by ionic quantification or put through a specially devised (sweat-check) conductivity analyser (Wescor Inc., Logan, Utah), and this technique has proven to yield equally satisfactory results with less technical problems compare…”
ResultRowe, S. M., Accurso, F., & Clancy, J. P. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200703-043br · Cited by 89
A wearable potentiometric sensor with integrated salt bridge for sweat chloride measurement
Choi, D., Li, Y., Cutting, G. R., & Searson, P. C. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.04.129 · Cited by 91
Self-powered smart patch for sweat conductivity monitoring
Ortega, L., Llorella, A., Esquivel, J. P., & Sabaté, N. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-018-0043-0 · Cited by 91
Newborn screening for cystic fibrosis in Victoria: 10 years' experience (1989‐1998)
Massie, J., Glazner, J. A., ROBERTSON, C. F., Olsen, M., & Francis, I. (2000) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2000.tb124123.x · Cited by 84
Viviani, L., Zolin, A., Mehta, A., & Olesen, H. V. (2014) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-9-81 · Cited by 87
Elpa, D. P., Chiu, H.-Y., Wu, S.-P., & Urban, P. L. (2021) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2020.11.009 · Cited by 81
Massie, J., Clements, B. S., & and the Australian Paediatric Respiratory Group (2005) · Pediatric Pulmonology · doi:10.1002/ppul.20191 · Cited by 86
“2 weeks.(29) A critical issuewith regard to the sweat test in infants is the choice of cutoff values.”
BackgroundScott, M. G., LeGrys, V. A., & Hood, J. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6164-9.00028-7 · Cited by 86
WHAT IS A CYSTIC FIBROSIS DIAGNOSIS?
Rosenstein, B. J. (1998) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(05)70091-5 · Cited by 97
Collie, J. T. B., Massie, R. J., Jones, O. A. H., LeGrys, V. A., & Greaves, R. F. (2014) · Pediatric Pulmonology · doi:10.1002/ppul.22945 · Cited by 72
“Current sweat test guidelines support conductivity measurement as a screening test, but not for the diagnosis of CF.(19,49,67) The Wescor Nanoduct method is also a point of care testing device that uses disposable cells containing a conductivity sensor.”
MethodInfluentialSweat conductivity and chloride titration for cystic fibrosis diagnosis in 3834 subjects
Lezana, J. L., Vargas, M. H., Bechara, J. K., Vergara, R. S. A., & Furuya, M. E. Y. (2003) · Journal of Cystic Fibrosis · doi:10.1016/s1569-1993(02)00146-7 · Cited by 68
Mastella, G., Cesare, G. D., Borruso, A., Menin, L., & Zanolla, L. (2000) · Acta Paediatrica · doi:10.1080/080352500750043378 · Cited by 68
Baker, L. B., Ungaro, C. T., Barnes, K. A., Nuccio, R. P., Reimel, A. J., & Stofan, J. R. (2014) · Physiological Reports · doi:10.14814/phy2.12007 · Cited by 67
“To date, the only reference ranges available for sweat [Na+] are for clinical use in the diagnosis of cystic fibrosis (Hammond et al. 1994).”
BackgroundSweat conductivity: An accurate diagnostic test for cystic fibrosis?
Mattar, A. C. V., Leone, C., Rodrigues, J. C., & Adde, F. V. (2014) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2014.01.002 · Cited by 60
“Studies comparing the QPIT to the conductivity test have been conducted since late 1950 and have shown good correlation and agreement between chloride and conductivity values [11–21].”
MethodNanoduct® sweat testing for rapid diagnosis in newborns, infants and children with cystic fibrosis
Desax, M.-C., Ammann, R. A., Hammer, J., Schoeni, M. H., & Barben, J. (2007) · European Journal of Pediatrics · doi:10.1007/s00431-007-0485-0 · Cited by 56
“The measured sweat conductivity has been shown to be about 15 mmol/L higher than the sweat chloride concentration because of additional anions such as bicarbonate and lactate [13, 21].”
BackgroundHeeley, M. E. (2000) · Archives of Disease in Childhood · doi:10.1136/adc.82.5.420 · Cited by 52
Barben, J., Ammann, R. A., Metlagel, A., & Schoeni, M. H. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.08.085 · Cited by 51
Ooi, C. Y., Dupuis, A., Ellis, L. E., Jarvi, K. A., Martin, S., Gonska, T. Y., Dorfman, R., Kortan, P. P., Solomon, M. P., Tullis, E. D., et al. (2012) · Thorax · doi:10.1136/thoraxjnl-2011-201454 · Cited by 50
Normativa del diagnóstico y el tratamiento de la afección respiratoria en la fibrosis quística
Máiz, L., Baranda, F., Coll, R., Prados, C., Vendrell, M., Escribano, A., Gärtner, S., de Gracia, S., Martínez, M. T., Salcedo, A., et al. (2001) · Archivos de Bronconeumología · doi:10.1016/s0300-2896(01)75101-0 · Cited by 52
Clinical Phenotypes and Genotypic Spectrum of Cystic Fibrosis in Chinese Children
Shen, Y., Liu, J., Zhong, L.-L., Mogayzel, P. J., Zeitlin, P. L., Sosnay, P. R., & Zhao, S. (2016) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2015.12.025 · Cited by 54
Sweat Testing and Recent Advances
Gökdemir, Y., & Karadag, B. T. (2021) · Frontiers in Pediatrics · doi:10.3389/fped.2021.649904 · Cited by 49
“As the bicarbonate and lactate ions in the sweat affect the conductivity, results do not show the sweat Cl concentration (26, 27, 33).”
BackgroundAssessment of Sweat-Testing Practices for the Diagnosis of Cystic Fibrosis
LeGrys, V. A. (2001) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2001-125-1420-aostpf · Cited by 47
Beyond liquid biopsy: Toward non-invasive assays for distanced cancer diagnostics in pandemics
Ferrara, F., Zoupanou, S., Primiceri, E., Ali, Z., & Chiriacò, M. S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113698 · Cited by 51
“Historically, sweat has been used for applications such as medical diagnosis of cystic fibrosis (CF) (Hammond et al., 1994) as well as fluid and electrolyte balance in athletes.”
Variability of sweat chloride concentration in subjects with cystic fibrosis and G551D mutations
Vermeulen, F. L., Camus, C. L., Davies, J. C., Bilton, D., Milenković, D., & Boeck, K. D. (2016) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2016.02.015 · Cited by 45
“The Macroduct Wescor system [2] was used to collect sweat from both arms sequentially at each of the 8 study visits (day 1, day 14 and weeks 8, 16, 24, 32, 40 and 48).”
BackgroundMethodIontophoretic Drug Delivery in the Oral Cavity
Wanasathop, A., & Li, S. K. (2018) · Pharmaceutics · doi:10.3390/pharmaceutics10030121 · Cited by 46
“For example, the US Food and Drug Administration (FDA) has approved iontophoresis treatments such as transdermal fentanyl (Ionsys in 2015, Medicines Co., Parsippany, NJ, USA) [35,36] and sumatriptan (Zecuity in 2013, NuPathe/Teva) [37,38], topical pilocarpine for sweat stimulation (e.g., Nanoduct and Macroduct) [39,40…”
BackgroundChloride Transport in Nasal Ciliated Cells of Cystic Fibrosis Heterozygotes
Sermet‐Gaudelus, I., Déchaux, M., Vallée, B., Fajac, A., Girodon, E., Nguyen‐Khoa, T., Marianowski, R., Hurbain, I., Bresson, J., Lenoir, G., et al. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-740oc · Cited by 45
Voter, K. Z., & Ren, C. L. (2008) · Clinical Reviews in Allergy & Immunology · doi:10.1007/s12016-008-8078-x · Cited by 44
Diagnosing cystic fibrosis: blood, sweat, and tears
Wallis, C. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.76.2.85 · Cited by 40
Vallejos, S., Hernando, E., Trigo‐López, M., García, F. C., García‐Valverde, M., Fernandez, D. I., Cabero, M. J., Quesada, R., & García, J. M. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb00682b · Cited by 43
Courville, C. A., Tidwell, S., Liu, B., Accurso, F. J., Dransfield, M. T., & Rowe, S. M. (2014) · Respiratory Research · doi:10.1186/1465-9921-15-25 · Cited by 43
“, Logan, UT) collection system as previously reported [11,20,21].”
MethodMallol, J., Sol�, D., Asher, I., Clayton, T., Stein, R., Soto-Quiroz, M., & Latin American ISAAC Collaborators Group: Isabelle Romieu (Cuernavaca, M. (2000) · Pediatric Pulmonology · doi:10.1002/1099-0496(200012)30:6<439::aid-ppul1>3.0.co;2-e · Cited by 162
Mattar, A. C. V., Gomes, E. N., Adde, F. V., Leone, C., & Rodrigues, J. C. (2010) · Jornal Vascular Brasileiro · doi:10.1590/s0021-75572010000200005 · Cited by 38
Taylor, C. J., Hardcastle, J., & Southern, K. W. (2009) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2009.05.002 · Cited by 44
Screening for congenital cytomegalovirus infection: A tapestry of controversies
Demmler, G. J. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.11.020 · Cited by 38
A new method of sweat testing: the CF Quantum®sweat test
Rock, M. J., Makholm, L., & Eickhoff, J. (2014) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2014.05.001 · Cited by 37
“An alternative method of sweat collection is by theMacroduct® method [17,18] in which sweat is collected in microbore tubing.”
A microfluidic patch for wireless wearable electrochemical detection of sweat metabolites
Hu, M., Wang, Z., Zhang, L., Lin, S., & Liao, J. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136604 · Cited by 38
Langen, A. M. M. V.-V., Dompeling, E., Yntema, J.-B. L., Arets, B. G. M., Tiddens, H. A. M. W., Loeber, G., & Dankert-Roelse, J. E. (2015) · European Journal of Pediatrics · doi:10.1007/s00431-015-2501-0 · Cited by 35
“The cutoff point for the diagnosis CF by means of conductivity measurement is unclear, but most studies use 80– 90mmol/l [1, 4, 8].”
MethodProtocolo de diagnóstico y seguimiento de los pacientes con fibrosis quística
de Agüero, M. I. B. G., Hernández, G. G., & Gärtner, S. (2009) · Anales de Pediatría · doi:10.1016/j.anpedi.2009.06.020 · Cited by 61
Rao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 45
CFTR p.Arg117His associated with CBAVD and other CFTR-related disorders
Thauvin‐Robinet, C., Munck, À., Huet, F., de Becdelièvre, A., Jimenez, C., Lalau, G., Gautier, É., ROLLET, J., Flori, J., Nové-Josserand, R., et al. (2013) · Journal of Medical Genetics · doi:10.1136/jmedgenet-2012-101427 · Cited by 30
Optical biosensing systems for a biological living body
Yan, T., Guo, C., Wang, C., & Zhu, K. (2023) · View · doi:10.1002/viw.20220059 · Cited by 30
Transscleral passive and iontophoretic transport: theory and analysis
Li, S. K., & Hao, J. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2018.1406918 · Cited by 29
“Macroduct) [14], lidocaine iontophoresis for local anesthesia (e.”
BackgroundCoakley, J., Scott, S., Doery, J. C. G., Greaves, R., Talsma, P., Whitham, E., & Winship, J. (2006) · PubMed Central · Cited by 36
Fibrosis quística del adulto: estudio de 111 pacientes
de Gracia, J., Fernández, A. Á., Mata, F., Guarner, L., Vendrell, M., Gadtner, S., & Cobos, N. (2002) · Medicina Clínica · doi:10.1016/s0025-7753(02)73513-6 · Cited by 30
Measurement of sodium concentration in sweat samples: comparison of 5 analytical techniques
Goulet, E. D. B., Asselin, A., Gosselin, J., & Baker, L. B. (2017) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0059 · Cited by 28
Zhao, G., Li, Z.-Y., Huang, X., Zhang, Q., Liu, Y., & Yu, X. (2024) · Soft Science · doi:10.20517/ss.2024.04 · Cited by 30
Rind, S., Zhang, N., Khan, W. U., & Zhang, Q. M. (2025) · Wearable electronics. · doi:10.1016/j.wees.2025.08.002 · Cited by 33
An unusual presentation of cystic fibrosis in an adult
Davé, S., Honney, S., Raymond, J. R., & Flume, P. A. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.11.009 · Cited by 30
Sermet‐Gaudelus, I., Munck, À., Rota, M., Roussey, M., Feldmann, D., & Nguyen-Khoa, T. (2010) · Archives de Pédiatrie · doi:10.1016/j.arcped.2010.06.021 · Cited by 37
Predictors of insufficient sweat production during confirmatory testing for cystic fibrosis
Kleyn, M. J., Korzeniewski, S. J., Grigorescu, V. I., Young, W., Homnick, D. N., Filbrun, A. G., Schuen, J. N., & Nasr, S. Z. (2010) · Pediatric Pulmonology · doi:10.1002/ppul.21318 · Cited by 28
“A study assessing the two methods found no difference between sodium and chloride concentration results obtained from the Macroduct system and from pilocarpine iontophoresis, though the Macroduct system was associated with higher QNS rates.(16) Both methods of sweat chloride testing are CF Foundationapproved for use f…”
ResultDoorn, J., Storteboom, T. T. R., Mulder, A., de Jong, W., Rottier, B. L., & Kema, I. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214549642 · Cited by 27
Abbasiasl, T., Mirlou, F., Istif, E., Koydemir, H. C., & Beker, L. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00032f · Cited by 28
The evaluation of a novel conductometric device for the diagnosis of cystic fibrosis
Losty, H., Wheatley, H., & Doull, I. J. M. (2006) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456306778520025 · Cited by 25
Daccò, V., Rosazza, C., Mariani, A., Rizza, C., Ingianni, N., Nazzari, E., Terlizzi, V., Blasi, F., & Alicandro, G. (2024) · Pediatric Pulmonology · doi:10.1002/ppul.27125 · Cited by 24
Gonska, T. Y., Choi, P., Stephenson, A. L., Ellis, L. E., Martin, S., Solomon, M. P., Dupuis, A., Dorfman, R., Zielenski, J., Ooi, C. Y., et al. (2012) · CHEST Journal · doi:10.1378/chest.11-2543 · Cited by 26
Comparison of two sweat test systems for the diagnosis of cystic fibrosis in newborns
Rueegg, C. S., Kuehni, C. E., Gallati, S., Jurca, M., Jung, A., Casaulta, C., Barben, J., & for the Swiss Cystic Fibrosis Screening Group (2019) · Pediatric Pulmonology · doi:10.1002/ppul.24227 · Cited by 25
“A value ≥80mmol/L was considered consistent with the diagnosis of CF, values from 50 to 79mmol/L as intermediate.(13,17,21,23) In healthy newborns at the age of 3-4 weeks, mean conductivity was 36mmol/L with a range of 12-64.”
BackgroundMethodStandards of care guidance for sweat testing; phase two of the ECFS quality improvement programme
Cirilli, N., Southern, K. W., Barben, J., Vermeulen, F. L., Munck, À., Wilschanski, M. A., Nguyen‐Khoa, T., Aralica, M., Simmonds, N. J., & Wachter, E. D. (2022) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2022.01.004 · Cited by 23
Sweat Test Results in Children with Primary Protein Energy Malnutrition
Yiğit, H., Selimoğlu, M. A., & Altınkaynak, S. (2003) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1002/j.1536-4801.2003.tb11987.x · Cited by 23
Comparison of quantitative sweat chloride methods after positive newborn screen for cystic fibrosis
Laguna, T. A., Lin, N., Wang, Q., Holme, B., McNamara, J., & Regelmann, W. E. (2012) · Pediatric Pulmonology · doi:10.1002/ppul.21608 · Cited by 22
Ďurč, P., Foret, F., Pokojová, E., Homola, L., Skřičková, J., Herout, V., Dastych, M., Vinohradská, H., & Kubáň, P. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0318-6 · Cited by 21
Kubáň, P., Greguš, M., Pokojová, E., Skřičková, J., & Foret, F. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.06.091 · Cited by 21
Sweat testing practice in Swiss hospitals
Casaulta, C., Spinas, R., & Schoeni, M. (2007) · Swiss Medical Weekly · doi:10.4414/smw.2007.11719 · Cited by 21
Massie, J., Greaves, R. F., Metz, M. P., Wiley, V. C., Graham, P., Shepherd, S., & Mackay, R. J. (2017) · Europe PMC (PubMed Central) · Cited by 23
Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening
Domingos, M. T., Magdalena, N., Cat, M. N. L., Watanabe, A. M., & Filho, N. A. R. (2015) · Jornal de Pediatria · doi:10.1016/j.jped.2015.03.003 · Cited by 20
“, Logan, UT, USA) collection system, the minimum volume of sweat required for this device.(9,13)”
BackgroundMethodBiological variation in sweat sodium chloride conductivity
van der Merwe, D.-E., Ubbink, J., Delport, R., Becker, P., Dhatt, G. S., & Vermaak, W. J. H. (2002) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563021901711 · Cited by 20
Relf, R., Willmott, A., Flint, M. S., Beale, L., & Maxwell, N. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2018.12.019 · Cited by 19
Normative data on regional sweat-sodium concentrations of professional male team-sport athletes
Ranchordas, M. K., Tiller, N. B., Ramchandani, G., Jutley, R., Blow, A., Tye, J., & Drury, B. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-017-0197-4 · Cited by 23
“Sweat samples were collected from the participant following 5-min seated rest, using methods stated previously [16].”
Keerthana, S., Saquib, M., Poojary, H., Illanad, G. H., Valavan, D., Selvakumar, M., Nayak, R., Mazumder, N., & Ghosh, C. (2024) · RSC Advances · doi:10.1039/d4ra01579g · Cited by 21
A reference interval for sweat chloride in infants aged between five and six weeks of age
Jayaraj, R., Barton, P., Newland, P., Mountford, R., Shaw, N. J., McCarthy, E. L., Isherwood, D. M., & Southern, K. W. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008081 · Cited by 18
Upasham, S., Osborne, O., & Prasad, S. (2021) · RSC Advances · doi:10.1039/d0ra10561a · Cited by 19
Courville, C. A., Raju, S. V., Liu, B., Accurso, F. J., Dransfield, M. T., & Rowe, S. M. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201502-0396le · Cited by 17
Shen, Y., Tang, X., Liu, J., Li, H., & Zhao, S. (2020) · Pediatric Pulmonology · doi:10.1002/ppul.25012 · Cited by 21
“1 | Sweat conductivity measurement The Macroduct collection system and Sweat‐Chek conductivity analyzer (Wescor Inc, Logan, Utah) were used for CF sweat conductivity analysis.(15) Based on a user's manual, sweat secretion was stimulated by pilocarpine iontophoresis.”
MethodShen, Y., Tang, X., Chen, Q., Xu, H., Liu, H., Liu, J., Yang, H., Li, H., & Zhao, S. (2022) · Journal of Medical Genetics · doi:10.1136/jmg-2022-108501 · Cited by 18
Sezer, R. G. (2013) · Journal of Clinical Medicine Research · doi:10.4021/jocmr1191w · Cited by 16
“They concluded that conductivity was equally satisfactory as chloride measurements [4].”
BackgroundInfluentialMicro-flowcell conductometric sweat analysis for cystic fibrosis diagnosis
Webster, H. L., & Quirante, C. G. (2000) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563001899348 · Cited by 15
Metadata
- Authors
- Hammond, K. B., Turcios, N. L., & Gibson, L. E.
- Affiliations
- University of Colorado Anschutz (US)
- Venue
- The Journal of Pediatrics
- Publisher
- Elsevier BV
- Published
- 1994-02
- Volume
- 124
- Issue
- 2
- Pages
- 255-260
- ISSN
- 0022-3476 (ISSN-L)
- OpenAlex
- W2074840452
- Cited by
- 178
- References
- 10
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 12 · 2023: 9 · 2022: 7 · 2021: 13 · 2020: 7 · 2019: 3 · 2018: 8 · 2017: 9 · 2016: 3 · 2015: 8 · 2014: 12 · 2013: 4 · 2012: 9
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Journal of Pediatrics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cystic Fibrosis Research Advances
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Physiology (medical) › Salivary Gland Disorders and Functions
- Keywords
- cystic fibrosis, sweat test, sweat conductivity, sweat chloride, sweat sodium
- MeSH terms
- Adolescent, Adult, Aged, Child, Child, Preschool, Chlorides, Cystic Fibrosis, Electric Conductivity, Humans, Infant, Infant, Newborn, Middle Aged, Osmolar Concentration, Potassium, Sodium, Specimen Handling, Sweat, Case-Control Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.