Presbyopia and the optical changes in the human crystalline lens with age
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Lenses from 27 human eyes ranging in age from 10 to 87 years were used to determine how accommodation and age affect the optical properties of the lens. A scanning laser technique was used to measure focal length and spherical aberration of the lenses, while the lenses were subjected to stretching forces applied through the ciliary body/zonular complex. The focal length of all unstretched lenses increased linearly with increasing age. Younger lenses were able to undergo significant changes in focal length with stretching, whereas lenses older than 60 years of age showed no changes in focal length with stretching. These data provide additional evidence for predominantly lens-based theories of presbyopia. Further, these results show that there are substantial optical changes in the human lens with increasing age and during accommodation, since both the magnitude and the sign of the spherical aberration change with age and stretching. These results show that the optical properties of the older presbyopic lens are quite different from the younger, accommodated lens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helmholtz's treatise on physiological optics
(1924) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(24)90484-4 · Cited by 696
Turner, R. P., Jared, D. A., Johnson, K. M., Crossland, W. A., Birch, M. J. H., Vass, D., & Underwood, I. (1990) · Cited by 580
Elastic constants of the human lens capsule
Fisher, R. F. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008739 · Cited by 288
Bennett, A. G., & Rabbetts, R. B. (1985) · Optometry and Vision Science · doi:10.1097/00006324-198512000-00015 · Cited by 279
AGE NORMS OF REFRACTION AND VISION
SLATAPER, F. J. (1950) · Archives of Ophthalmology · doi:10.1001/archopht.1950.00910010475007 · Cited by 254
Neural contribution to spatiotemporal contrast sensitivity decline in healthy ageing eyes
Elliott, D., Whitaker, D., & MacVeigh, D. (1990) · Vision Research · doi:10.1016/0042-6989(90)90066-t · Cited by 235 · cited 1×
“However, a neural contribution has also been postulated to explain age-related losses in contrast sensitivity function (Elliott et al., 1990).”
Koretz, J. F., & Handelman, G. H. (1988) · Scientific American · doi:10.1038/scientificamerican0788-92 · Cited by 180
Spherical aberration of the crystalline lens
Sivak, J. G., & Kreuzer, R. O. (1983) · Vision Research · doi:10.1016/0042-6989(83)90042-1 · Cited by 112
Campbell, M. C., & Hughes, A. (1981) · Vision Research · doi:10.1016/0042-6989(81)90016-x · Cited by 111
Self-citationHelmholtz's Treatise on Physiological Optics
Peddie, D. W. (1924) · Nature · doi:10.1038/114887a0 · Cited by 104
Cited by
Age-related nuclear cataract—oxidation is the key
Truscott, R. J. W. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2004.12.007 · Cited by 857
Owsley, C. (2011) · Vision Research · doi:10.1016/j.visres.2010.10.020 · Cited by 701
A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes
Holladay, J. T., Piers, P. A., Koranyi, G., van der Mooren, M., & Norrby, N. E. S. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20021101-04 · Cited by 560
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
Artal, P., Berrio, E., Guirao, A., & Piers, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000137 · Cited by 494
Compensation of corneal aberrations by the internal optics in the human eye
Artal, P., Guirao, A., Berrio, E., & Williams, D. R. (2001) · Journal of Vision · doi:10.1167/1.1.1 · Cited by 434
Glasser, A., & C.W. Campbell, M. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00283-1 · Cited by 425
Self-citationPresbyopia: Effectiveness of correction strategies
Wolffsohn, J. S., & Davies, L. N. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.09.004 · Cited by 324
Optical aberrations of the human cornea as a function of age
Guirao, A., Redondo, M., & Artal, P. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.001697 · Cited by 303
Ocular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Surgical applications of femtosecond lasers
Chung, S. H., & Mazur, E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910053 · Cited by 281
Myopic versus hyperopic eyes: axial length, corneal shape and optical aberrations
Llorente, L., Barbero, S., Cano, D., Dorronsoro, C., & Marcos, S. (2004) · Journal of Vision · doi:10.1167/4.4.5 · Cited by 233
“In particular , the increase of spherical aberration with age has been attributed to a shift of the spherical aberration of the crystalline lens toward positive (or less negative) values (Glasser & Campbell, 1998).”
BackgroundOptical coherence elastography in ophthalmology
Kirby, M. A., Pelivanov, I., Song, S., Ambrozinski, Ł., Yoon, S. J., Gao, L., Li, D., Shen, T. T., Wang, R. K., & O’Donnell, M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121720 · Cited by 228
“With aging, it becomes less pliable and loses the ability to accommodate (the process of changing focus from near to far).(168) This loss is associated with reduced accommodation and may be directly measurable using OCE methods, as demonstrated using ARF-OCE to detect age-related stiffness in rabbit lens.”
MethodThe human eye is an example of robust optical design
Artal, P., Benito, A., & Tabernero, J. (2006) · Journal of Vision · doi:10.1167/6.1.1 · Cited by 222
“The changes in the shape and size of the lens through life (Glasser & Campbell, 1998) may explain the progressive lack of compensation occurring in older eyes.”
BackgroundOcular higher-order aberrations in individuals screened for refractive surgery
Wang, L., & Koch, D. D. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00643-6 · Cited by 205
Owsley, C. (2016) · Annual Review of Vision Science · doi:10.1146/annurev-vision-111815-114550 · Cited by 179
Prospective Randomized Trial of an Anterior Surface Modified Prolate Intraocular Lens
Packer, M., Fine, I. H., Hoffman, R. S., & Piers, P. A. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20021101-05 · Cited by 172
Numerical modelling of the accommodating lens
Burd, H. J., Judge, S. J., & Cross, J. A. (2002) · Vision Research · doi:10.1016/s0042-6989(02)00094-9 · Cited by 164
Dynamic mechanical properties of human lenses
Weeber, H. A., Eckert, G., Soergel, F., Meyer, C. H., Pechhold, W., & van der Heijde, R. G. L. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2004.10.010 · Cited by 164
“More recent studies indicate that lens stiffening alone can be responsible for the inability of the lens to change its refractive power at older age (Pierscionek, 1995; Glasser and Campbell, 1998).”
BackgroundThe Optical Design of the Human Eye: a Critical Review
Navarro, R. (2009) · Journal of Optometry · doi:10.3921/joptom.2009.3 · Cited by 160
“Even though artificial stretchers have been developed 61 to simulate the action of ciliary forces, it is difficult to make direct comparisons.”
BackgroundImproved functional vision with a modified prolate intraocular lens
Packer, M., Fine, H. I., Hoffman, R. S., & Piers, P. A. (2004) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2003.10.022 · Cited by 159
Metadata
- Authors
- Glasser, A., & Campbell, M. C. W.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1998-01
- Volume
- 38
- Issue
- 2
- Pages
- 209-229
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2009178659
- Cited by
- 601
- References
- 17
- FWCI
- 11.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.