Screening for fetal growth restriction with universal third trimester ultrasonography in nulliparous women in the Pregnancy Outcome Prediction (POP) study: a prospective cohort study
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Fetal growth restriction is a major determinant of adverse perinatal outcome. Screening procedures for fetal growth restriction need to identify small babies and then differentiate between those that are healthy and those that are pathologically small. We sought to determine the diagnostic effectiveness of universal ultrasonic fetal biometry in the third trimester as a screening test for small-for-gestational-age (SGA) infants, and whether the risk of morbidity associated with being small differed in the presence or absence of ultrasonic markers of fetal growth restriction. METHODS: The Pregnancy Outcome Prediction (POP) study was a prospective cohort study of nulliparous women with a viable singleton pregnancy at the time of the dating ultrasound scan. Women participating had clinically indicated ultrasonography in the third trimester as per routine clinical care and these results were reported as usual (selective ultrasonography). Additionally, all participants had research ultrasonography, including fetal biometry at 28 and 36 weeks' gestational age. These results were not made available to participants or treating clinicians (universal ultrasonography). We regarded SGA as a birthweight of less than the 10th percentile for gestational age and screen positive for SGA an ultrasonographic estimated fetal weight of less than the 10th percentile for gestational age. Markers of fetal growth restriction included biometric ratios, utero-placental Doppler, and fetal growth velocity. We assessed outcomes for consenting participants who attended research scans and had a livebirth at the Rosie Hospital (Cambridge, UK) after the 28 weeks' research scan. FINDINGS: Between Jan 14, 2008, and July 31, 2012, 4512 women provided written informed consent of whom 3977 (88%) were eligible for analysis. Sensitivity for detection of SGA infants was 20% (95% CI 15-24; 69 of 352 fetuses) for selective ultrasonography and 57% (51-62; 199 of 352 fetuses) for universal ultrasonography (relative sensitivity 2·9, 95% CI 2·4-3·5, p<0·0001). Of the 3977 fetuses, 562 (14·1%) were identified by universal ultrasonography with an estimated fetal weight of less than the 10th percentile and were at an increased risk of neonatal morbidity (relative risk [RR] 1·60, 95% CI 1·22-2·09, p=0·0012). However, estimated fetal weight of less than the 10th percentile was only associated with the risk of neonatal morbidity (pinteraction=0·005) if the fetal abdominal circumference growth velocity was in the lowest decile (RR 3·9, 95% CI 1·9-8·1, p=0·0001). 172 (4%) of 3977 pregnancies had both an estimated fetal weight of less than the 10th percentile and abdominal circumference growth velocity in the lowest decile, and had a relative risk of delivering an SGA infant with neonatal morbidity of 17·6 (9·2-34·0, p<0·0001). INTERPRETATION: Screening of nulliparous women with universal third trimester fetal biometry roughly tripled detection of SGA infants. Combined analysis of fetal biometry and fetal growth velocity identified a subset of SGA fetuses that were at increased risk of neonatal morbidity. FUNDING: National Institute for Health Research, Medical Research Council, Sands, and GE Healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
The English indices of deprivation 2004
Noble, M., Wright, G., Dibben, C., Smith, G., McLennan, D., Anttila, C., Barnes, H., Mokhtar, C., Noble, S., & Gardner, J. (2004) · Cited by 1,494
Self-citationCross sectional stature and weight reference curves for the UK, 1990.
Freeman, J. V., Cole, T. J., Chinn, S., Jones, P. R., White, E. M., & Preece, M. A. (1995) · Archives of Disease in Childhood · doi:10.1136/adc.73.1.17 · Cited by 1,457
In utero analysis of fetal growth: a sonographic weight standard
Hadlock, F. P., Harrist, R. B., & Martinez-Poyer, J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887021 · Cited by 1,281
Adult Consequences of Fetal Growth Restriction
BARKER, D. J. P. (2006) · Clinical Obstetrics and Gynecology · doi:10.1097/00003081-200606000-00009 · Cited by 930
Papageorghiou, A. T., Ohuma, E. O., Altman, D. G., Todros, T., Ismail, L. C., Lambert, A., Jaffer, Y. A., Bertino, E., Gravett, M. G., Purwar, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61490-2 · Cited by 870
An adjustable fetal weight standard
Gardosi, J., Mongelli, M., Wilcox, M., & Chang, A. (1995) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1995.06030168.x · Cited by 568
ISUOG Practice Guidelines: use of Doppler ultrasonography in obstetrics
(2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12371 · Cited by 445
MacKay, D. F., Smith, G. C. S., Dobbie, R., & Pell, J. P. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000289 · Cited by 437
Self-citationRoutine ultrasound in late pregnancy (after 24 weeks' gestation)
Bricker, L., Medley, N., & Pratt, J. J. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001451.pub4 · Cited by 337
Cited by
Andreoli, L., Bertsias, G. K., Agmon-Levin, N., Brown, S., Cervera, R., Costedoat-Chalumeau, N., Doria, A., Fischer-Betz, R., Forger, F., Moraes-Fontes, M. F., et al. (2017) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2016-209770 · Cited by 945
Lees, C. C., Stampalija, T., Baschat, A. A., da Silva Costa, F., Ferrazzi, E., Figueras, F., Hecher, K., Kingdom, J., Poon, L. C., Salomon, L. J., et al. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22134 · Cited by 886
Kiserud, T., Piaggio, G., Carroli, G., Widmer, M., Carvalho, J., Neerup Jensen, L., Giordano, D., Cecatti, J. G., Abdel Aleem, H., Talegawkar, S. A., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002220 · Cited by 729
ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth
Salomon, L. J., Alfirevic, Z., Da Silva Costa, F., Deter, R. L., Figueras, F., Ghi, T., Glanc, P., Khalil, A., Lee, W., Napolitano, R., et al. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20272 · Cited by 704
Human placenta has no microbiome but can contain potential pathogens
de Goffau, M. C., Lager, S., Sovio, U., Gaccioli, F., Cook, E., Peacock, S. J., Parkhill, J., Charnock-Jones, D. S., & Smith, G. C. S. (2019) · Nature · doi:10.1038/s41586-019-1451-5 · Cited by 691
Self-citationStillbirths: recall to action in high-income countries
Flenady, V., Wojcieszek, A. M., Middleton, P., Ellwood, D., Erwich, J. J., Coory, M., Khong, T. Y., Silver, R. M., Smith, G. C. S., Boyle, F. M., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01020-x · Cited by 667
Self-citationMelamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Hug, L., You, D., Blencowe, H., Mishra, A., Wang, Z., Fix, M. J., Wakefield, J., Moran, A. C., Gaigbe-Togbe, V., Suzuki, E., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01112-0 · Cited by 527
McCowan, L. M., Figueras, F., & Anderson, N. H. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.004 · Cited by 451
Advanced maternal age and adverse pregnancy outcomes
Frick, A. P. (2021) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2020.07.005 · Cited by 304
Diagnosis and surveillance of late-onset fetal growth restriction
Figueras, F., Caradeux, J., Crispi, F., Eixarch, E., Peguero, A., & Gratacos, E. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.003 · Cited by 300
Burgos-Artizzu, X. P., Coronado-Gutiérrez, D., Valenzuela-Alcaraz, B., Bonet-Carne, E., Eixarch, E., Crispi, F., & Gratacós, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-67076-5 · Cited by 240
Verlohren, S., Brennecke, S. P., Galindo, A., Karumanchi, S. A., Mirkovic, L. B., Schlembach, D., Stepan, H., Vatish, M., Zeisler, H., & Rana, S. (2022) · Pregnancy Hypertension · doi:10.1016/j.preghy.2021.12.003 · Cited by 233
Kiserud, T., Benachi, A., Hecher, K., Perez, R. G., Carvalho, J., Piaggio, G., & Platt, L. D. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.010 · Cited by 228
Hypertensive disorders of pregnancy
Wu, P., Green, M., & Myers, J. E. (2023) · BMJ · doi:10.1136/bmj-2022-071653 · Cited by 222
Sovio, U., Murphy, H. R., & Smith, G. C. S. (2016) · Diabetes Care · doi:10.2337/dc16-0160 · Cited by 220
Self-citationAn integrated approach to fetal growth restriction
Figueras, F., & Gratacos, E. (2017) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2016.10.006 · Cited by 217
The diagnosis and management of suspected fetal growth restriction: an evidence-based approach
Lees, C. C., Romero, R., Stampalija, T., Dall’Asta, A., DeVore, G. R., Prefumo, F., Frusca, T., Visser, G. H. A., Hobbins, J. C., Baschat, A. A., et al. (2022) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2021.11.1357 · Cited by 215
The Placental Basis of Fetal Growth Restriction
Zur, R. L., Kingdom, J. C., Parks, W. T., & Hobson, S. R. (2020) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/j.ogc.2019.10.008 · Cited by 214
Inherent mosaicism and extensive mutation of human placentas
Coorens, T. H. H., Oliver, T. R. W., Sanghvi, R., Sovio, U., Cook, E., Vento-Tormo, R., Haniffa, M., Young, M. D., Rahbari, R., Sebire, N., et al. (2021) · Nature · doi:10.1038/s41586-021-03345-1 · Cited by 211
Self-citationScreening for fetal growth restriction and placental insufficiency
Audette, M. C., & Kingdom, J. C. (2018) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2017.11.004 · Cited by 206
ISUOG Practice Guidelines: role of ultrasound in screening for and follow‐up of pre‐eclampsia
Sotiriadis, A., Hernandez‐Andrade, E., da Silva Costa, F., Ghi, T., Glanc, P., Khalil, A., Martins, W. P., Odibo, A. O., Papageorghiou, A. T., Salomon, L. J., et al. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20105 · Cited by 203
Jardine, J., Walker, K., Gurol-Urganci, I., Webster, K., Muller, P., Hawdon, J., Khalil, A., Harris, T., & van der Meulen, J. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01595-6 · Cited by 187
Luyckx, V. A., Perico, N., Somaschini, M., Manfellotto, D., Valensise, H., Cetin, I., Simeoni, U., Allegaert, K., Vikse, B. E., Steegers, E. A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30576-7 · Cited by 182
Consensus Based Definition of Growth Restriction in the Newborn
Beune, I. M., Bloomfield, F. H., Ganzevoort, W., Embleton, N. D., Rozance, P. J., van Wassenaer-Leemhuis, A. G., Wynia, K., & Gordijn, S. J. (2018) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2017.12.059 · Cited by 180
Kuhle, S., Maguire, B., Zhang, H., Hamilton, D., Allen, A. C., Joseph, K. S., & Allen, V. M. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1971-2 · Cited by 166
Screening for fetal growth restriction using fetal biometry combined with maternal biomarkers
Gaccioli, F., Aye, I. L. M. H., Sovio, U., Charnock-Jones, D. S., & Smith, G. C. S. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.002 · Cited by 161
Self-citationMadden, J. V., Flatley, C. J., & Kumar, S. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.02.008 · Cited by 133
Caradeux, J., Martinez-Portilla, R. J., Peguero, A., Sotiriadis, A., & Figueras, F. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.043 · Cited by 122
Palmer, K. R., Tanner, M., Davies-Tuck, M., Rindt, A., Papacostas, K., Giles, M. L., Brown, K., Diamandis, H., Fradkin, R., Stewart, A. E., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00668-1 · Cited by 121
Sheikh, J., Allotey, J., Kew, T., Fernández-Félix, B. M., Zamora, J., Khalil, A., Thangaratinam, S., Abdollahain, M., Savitri, A. I., Salvesen, K. Å., et al. (2022) · The Lancet · doi:10.1016/s0140-6736(22)01191-6 · Cited by 108
Self-citationFetal growth velocity and body proportion in the assessment of growth
Hiersch, L., & Melamed, N. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.014 · Cited by 100
Deter, R. L., Lee, W., Yeo, L., Erez, O., Ramamurthy, U., Naik, M., & Romero, R. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.210 · Cited by 80
Outcome‐based comparison of SMFM and ISUOG definitions of fetal growth restriction
Roeckner, J. T., Pressman, K., Odibo, L., Duncan, J. R., & Odibo, A. O. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23638 · Cited by 60
Monier, I., Ancel, P.-Y., Ego, A., Jarreau, P.-H., Lebeaux, C., Kaminski, M., Goffinet, F., & Zeitlin, J. (2017) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.02.001 · Cited by 46
Yordan, J., Holbrook, B., Nirgudkar, P., Mozurkewich, E., & Blue, N. (2017) · American Journal of Perinatology · doi:10.1055/s-0037-1604059 · Cited by 41
Meler, E., Mazarico, E., Eixarch, E., Gonzalez, A., Peguero, A., Martinez, J., Boada, D., Vellvé, K., Gomez‐Roig, M. D., Gratacós, E., et al. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23537 · Cited by 36
Salavati, N., Sovio, U., Mayo, R. P., Charnock-Jones, D. S., & Smith, G. C. S. (2016) · Placenta · doi:10.1016/j.placenta.2015.12.003 · Cited by 35
Self-citationSchreiber, V., Hurst, C., da Silva Costa, F., Stoke, R., Turner, J., & Kumar, S. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26035 · Cited by 34
Teulings, N. E. W. D., Wood, A. M., Sovio, U., Ozanne, S. E., Smith, G. C. S., & Aiken, C. E. (2020) · International Journal of Obesity · doi:10.1038/s41366-020-0627-2 · Cited by 30
Self-citationAllotey, J., Laivuori, H., Snell, K. I., Smuk, M., Hooper, R., Chan, C. L., Ahmed, A., Chappell, L. C., von Dadelszen, P., Dodds, J., et al. (2020) · Health Technology Assessment · doi:10.3310/hta24720 · Cited by 30
Self-citationBello‐Álvarez, L., Fernández‐Félix, B. M., Allotey, J., Thangaratinam, S., & Zamora, J. (2026) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.70401 · Cited by 20
Xu, Y., Lee, L. H., Drukker, L., Yaqub, M., Papageorghiou, A. T., & Noble, A. J. (2020) · Journal of medical imaging · doi:10.1117/1.jmi.7.5.057001 · Cited by 8
Metadata
- Authors
- Sovio, U., White, I. R., Dacey, A., Pasupathy, D., & Smith, G. C. S.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 386
- Issue
- 10008
- Pages
- 2089-2097
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2178653331
- Cited by
- 609
- References
- 31
- FWCI
- 54.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.