Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous electronic fetal heart-rate monitoring is widely used during labour, and computerised interpretation could increase its usefulness. We aimed to establish whether the addition of decision-support software to assist in the interpretation of cardiotocographs affected the number of poor neonatal outcomes. METHODS: In this unmasked randomised controlled trial, we recruited women in labour aged 16 years or older having continuous electronic fetal monitoring, with a singleton or twin pregnancy, and at 35 weeks' gestation or more at 24 maternity units in the UK and Ireland. They were randomly assigned (1:1) to decision support with the INFANT system or no decision support via a computer-generated stratified block randomisation schedule. The primary outcomes were poor neonatal outcome (intrapartum stillbirth or early neonatal death excluding lethal congenital anomalies, or neonatal encephalopathy, admission to the neonatal unit within 24 h for ≥48 h with evidence of feeding difficulties, respiratory illness, or encephalopathy with evidence of compromise at birth), and developmental assessment at age 2 years in a subset of surviving children. Analyses were done by intention to treat. This trial is completed and is registered with the ISRCTN Registry, number 98680152. FINDINGS: Between Jan 6, 2010, and Aug 31, 2013, 47 062 women were randomly assigned (23 515 in the decision-support group and 23 547 in the no-decision-support group) and 46 042 were analysed (22 987 in the decision-support group and 23 055 in the no-decision-support group). We noted no difference in the incidence of poor neonatal outcome between the groups-172 (0·7%) babies in the decision-support group compared with 171 (0·7%) babies in the no-decision-support group (adjusted risk ratio 1·01, 95% CI 0·82-1·25). At 2 years, no significant differences were noted in terms of developmental assessment. INTERPRETATION: Use of computerised interpretation of cardiotocographs in women who have continuous electronic fetal monitoring in labour does not improve clinical outcomes for mothers or babies. FUNDING: National Institute for Health Research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, it is not clear how to effectively integrate AI tools with human decision-makers; indeed, the few cases where systems have been implemented and studied showed no improved clinical outcomes6,7.”
From Do as AI say: susceptibility in deployment of clinical decision-aids (2021) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alfirevic, Z., Devane, D., & Gyte, G. M. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066 · Cited by 1,035
Composite Outcomes in Randomized Trials: Greater Precision But With Greater Uncertainty?
Freemantle, N., Calvert, M., Wood, J., Eastaugh, J., & Griffin, C. (2003) · JAMA · doi:10.1001/jama.289.19.2554 · Cited by 783
Urgency of caesarean section: A new classification
Lucas, D. N., Yentis, S. M., Kinsella, S. M., Holdcroft, A., May, A. E., Wee, M., & Robinson, P. N. (2000) · Journal of the Royal Society of Medicine · doi:10.1177/014107680009300703 · Cited by 463
(1991) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(91)90759-k · Cited by 335
The Primary Outcome Fails — What Next?
Pocock, S. J., & Stone, G. W. (2016) · New England Journal of Medicine · doi:10.1056/nejmra1510064 · Cited by 274
Umbilical cord blood gas analysis at delivery: a time for quality data
Westgate, J., Garibaldi, J. M., & Greene, K. R. (1994) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13581.x · Cited by 244
Self-citationWestgate, J., Harris, M., Curnow, J. S. H., & Greene, K. R. (1993) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(93)90273-l · Cited by 238
Self-citationCase-control study of intrapartum care, cerebral palsy, and perinatal death
Gaffney, G., Sellers, S., Flavell, V, Squier, M., & Johnson, A. (1994) · BMJ · doi:10.1136/bmj.308.6931.743 · Cited by 216
Alfirevic, Z., Devane, D., & Gyte, G. M. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066.pub2 · Cited by 208
Developmental assessment of preterm infants at 2 years: validity of parent reports
Johnson, S., Wolke, D., Marlow, N., & for the Preterm Infant Parenting Study Group. (2008) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2007.02010.x · Cited by 189
Research works printed but not linked: 2
- National Collaborating Centre for Women's and Children's Health (UK) Intrapartum care for healthy women and babies 2014 RCOG Press London 21250397
- National Perinatal Epidemiology Unit Disability and perinatal care: measurement of health status at two years. A report of two working groups convened by the National Perinatal Epidemiology Unit and the former Oxford Regional Health Authority 1994 National Perinatal Epidemiology Unit Oxford
Cited by
Key challenges for delivering clinical impact with artificial intelligence
Kelly, C. J., Karthikesalingam, A., Suleyman, M., Corrado, G., & King, D. (2019) · BMC Medicine · doi:10.1186/s12916-019-1426-2 · Cited by 3,136
Park, S. H., & Han, K. (2018) · Radiology · doi:10.1148/radiol.2017171920 · Cited by 894
Do as AI say: susceptibility in deployment of clinical decision-aids
Gaube, S., Suresh, H., Raue, M., Merritt, A., Berkowitz, S. J., Lermer, E., Coughlin, J. F., Guttag, J. V., Colak, E., & Ghassemi, M. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00385-9 · Cited by 543
Kim, D. W., Jang, H. Y., Kim, K. W., Shin, Y., & Park, S. H. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2019.0025 · Cited by 459
Khosravi, M., Zare, Z., Mojtabaeian, S. M., & Izadi, R. (2024) · Health Services Research and Managerial Epidemiology · doi:10.1177/23333928241234863 · Cited by 265
The physiology of intrapartum fetal compromise at term
Turner, J. M., Mitchell, M. D., & Kumar, S. S. (2020) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2019.07.032 · Cited by 194
Alabi, R. O., Youssef, O., Pirinen, M., Elmusrati, M., Mäkitie, A. A., Leivo, I., & Almangush, A. (2021) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2021.102060 · Cited by 174
Methods for clinical evaluation of artificial intelligence algorithms for medical diagnosis
Park, S. H., Han, K., Jang, H. Y., Park, J. E., Lee, J.-G., Kim, D. W., & Choi, J. (2023) · Radiology · doi:10.1148/radiol.220182 · Cited by 163
Blomberg, S. N., Christensen, H. C., Lippert, F., Ersbøll, A. K., Torp-Petersen, C., Sayre, M. R., Kudenchuk, P. J., & Folke, F. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.32320 · Cited by 138
Quality assurance of computer-aided detection and diagnosis in colonoscopy
Vinsard, D. G., Mori, Y., Misawa, M., Kudo, S.-E., Rastogi, A., Bagci, U., Rex, D. K., & Wallace, M. B. (2019) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2019.03.019 · Cited by 137
Zhou, Q., Chen, Z.-H., Cao, Y.-H., & Peng, S. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00524-2 · Cited by 126
Park, S. H., Choi, J., & Byeon, J. (2021) · Korean Journal of Radiology · doi:10.3348/kjr.2021.0048 · Cited by 153
Kennedy, H. P., Cheyney, M., Dahlen, H. G., Downe, S., Foureur, M. J., Homer, C. S. E., Jefford, E., McFadden, A., Michel‐Schuldt, M., Sandall, J., et al. (2018) · Birth · doi:10.1111/birt.12361 · Cited by 108
Balayla, J., & Shrem, G. (2019) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-019-05151-7 · Cited by 106
Cresswell, K., Callaghan, M., Khan, S., Sheikh, Z., Mozaffar, H., & Sheikh, A. (2020) · Health Informatics Journal · doi:10.1177/1460458219900452 · Cited by 87
Translation of AI into oncology clinical practice
El Naqa, I., Karolak, A., Luo, Y., Folio, L., Tarhini, A. A., Rollison, D., & Parodi, K. (2023) · Oncogene · doi:10.1038/s41388-023-02826-z · Cited by 81
Georgieva, A., Abry, P., Chudáček, V., Djurić, P. M., Frasch, M. G., Kok, R., Lear, C. A., Lemmens, S. N., Nunes, I., Papageorghiou, A. T., et al. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13639 · Cited by 78
Challenges and prospects of visual contactless physiological monitoring in clinical study
Huang, B., Hu, S., Liu, Z., Lin, C., Su, J., Zhao, C., Wang, L., & Wang, W. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00973-x · Cited by 92
Park, S. H., & Kressel, H. Y. (2018) · Journal of Korean Medical Science · doi:10.3346/jkms.2018.33.e152 · Cited by 66
Wattar, B. H. A., Honess, E. R., Bunnewell, S., Welton, N. J., Quenby, S. M., Khan, K. S., Zamora, J., & Thangaratinam, S. (2021) · Canadian Medical Association Journal · doi:10.1503/cmaj.202538 · Cited by 72
The Future Role of Machine Learning in Clinical Transplantation
Connor, K. L., O'Sullivan, E. D., Marson, L., Wigmore, S. J., & Harrison, E. M. (2020) · Transplantation · doi:10.1097/tp.0000000000003424 · Cited by 63
Trusting under risk – comparing human to AI decision support agents
Fahnenstich, H., Rieger, T., & Roesler, E. (2023) · Computers in Human Behavior · doi:10.1016/j.chb.2023.108107 · Cited by 73
Artificial Intelligence in Cardiac MRI: Is Clinical Adoption Forthcoming?
Fotaki, A., Anton, E. P., Chiribiri, A., Botnar, R. M., Pushparajah, K., & Prieto, C. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.818765 · Cited by 65
Clinical negligence costs: taking action to safeguard NHS sustainability
Yau, C. W. H., Leigh, B., Liberati, E. G., Punch, D., Dixon‐Woods, M., & Draycott, T. J. (2020) · BMJ · doi:10.1136/bmj.m552 · Cited by 53
Huang, B., Chen, W., Lin, C., Juang, C., Xing, Y., Wang, Y., & Wang, J. (2021) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2021.104447 · Cited by 60
Hanna, M. G., Olson, N. H., Zarella, M. D., Dash, R. C., Herrmann, M. D., Furtado, L. V., Stram, M. N., Raciti, P. M., Hassell, L. A., Mays, A., et al. (2023) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2023-0042-cp · Cited by 58
Wilhelm, C., Steckelberg, A., & Rebitschek, F. G. (2024) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2024.101145 · Cited by 82
No. 396-Fetal Health Surveillance: Intrapartum Consensus Guideline
Dore, S., & Ehman, W. (2020) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2019.05.007 · Cited by 61
Johnson, S. J., Bountziouka, V., Brocklehurst, P., Linsell, L., Marlow, N., Dieter Wolke, C., & Manktelow, B. N. (2019) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(19)30189-0 · Cited by 57
Self-citationLensen, S. F., Macnair, A., Love, S., Yorke-Edwards, V., Noor, N. M., Martyn, M., Blenkinsop, A., Díaz-Montaña, C., Powell, G. A., Williamson, E., et al. (2020) · Trials · doi:10.1186/s13063-020-04329-8 · Cited by 50
Clinical deployment environments: Five pillars of translational machine learning for health
Harris, S. K., Bonnici, T., Keen, T., Lilaonitkul, W., White, M. J., & Swanepoel, N. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.939292 · Cited by 54
Mendis, L., Palaniswami, M. S., Brownfoot, F., & Keenan, E. (2023) · Bioengineering · doi:10.3390/bioengineering10091007 · Cited by 58
Artificial intelligence as a new answer to old challenges in maternal-fetal medicine and obstetrics
Medjedović, E., Stanojević, M., Jonuzovic-Prosic, S., Ribić, E., Begić, Z., Cerovac, A., & Badnjević, A. (2023) · Technology and Health Care · doi:10.3233/thc-231482 · Cited by 46
Campanile, M., D’Alessandro, P., Corte, L. D., Saccone, G., Tagliaferri, S., Arduino, B., Esposito, G., Esposito, F. G., Raffone, A., Signorini, M. G., et al. (2018) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2018.1542676 · Cited by 48
Turner, J., Dunn, L., Tarnow‐Mordi, W., Flatley, C. J., Flenady, V., & Kumar, S. (2020) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.01.025 · Cited by 38
Leveraging physiology and artificial intelligence to deliver advancements in health care
Zhang, A., Wu, Z., Wu, E., Wu, M. A., Snyder, M. P., Zou, J., & Wu, J. C. (2023) · Physiological Reviews · doi:10.1152/physrev.00033.2022 · Cited by 51
Changing Perspectives of Electronic Fetal Monitoring
Evans, M. I., Britt, D. W., Evans, S. M., & Devoe, L. D. (2021) · Reproductive Sciences · doi:10.1007/s43032-021-00749-2 · Cited by 44
Computerized cardiotocography analysis during labor – A state‐of‐the‐art review
M’Barek, I. B., Jauvion, G., & Ceccaldi, P. (2022) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.14498 · Cited by 56
Emerging Ethical Considerations for the Use of Artificial Intelligence in Ophthalmology
Evans, N. G., Wenner, D. M., Cohen, I. G., Purves, D., Chiang, M. F., Ting, D. S. W., & Lee, A. (2022) · Ophthalmology Science · doi:10.1016/j.xops.2022.100141 · Cited by 45
Challenges of Developing Robust AI for Intrapartum Fetal Heart Rate Monitoring
O’Sullivan, M., Considine, E. C., O’Riordan, M., Marnane, W. P., Rennie, J. M., & Boylan, G. B. (2021) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2021.765210 · Cited by 46
Das, S., Mukherjee, H., Roy, K., & Saha, C. K. (2023) · Diagnostics · doi:10.3390/diagnostics13050858 · Cited by 34
McCoy, J. A., Levine, L. D., Wan, G., Chivers, C., Teel, J., & Cava, W. L. (2024) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2024.04.022 · Cited by 52
Artificial intelligence and machine learning in cardiotocography: A scoping review
Aeberhard, J. L., Radan, A., Delgado-Gonzalo, R., Strahm, K. M., Sigurthorsdottir, H., Schneider, S., & Surbek, D. (2022) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2022.12.008 · Cited by 47
Kim, Y., Park, J. Y., Hwang, E. J., Lee, S. M., & Park, C. M. (2021) · Journal of Thoracic Disease · doi:10.21037/jtd-21-1342 · Cited by 31
Bankuoru Egala, S., & Liang, D. (2024) · European Journal of Information Systems · doi:10.1080/0960085x.2023.2251927 · Cited by 30
Farquhar, C. M., Armstrong, S., Masson, V. L., Thompson, J., & Sadler, L. C. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.21363 · Cited by 30
Castro, L., Loureiro, M., Henriques, T. S., & Nunes, I. (2021) · Frontiers in Pediatrics · doi:10.3389/fped.2021.661400 · Cited by 36
Mohan, M., Ramawat, J., LaMonica, G. E., Jayaram, P., Fattah, S. A., Learmont, J. G., Bryan, C., Zaoui, S., Pullattayil, A. K., Konje, J. C., et al. (2021) · AJOG Global Reports · doi:10.1016/j.xagr.2021.100008 · Cited by 35
Eden, R. D., Evans, M. I., Evans, S. M., & Schifrin, B. S. (2017) · Reproductive Sciences · doi:10.1177/1933719117737849 · Cited by 29
Lopes-Pereira, J., Costa, A., Ayres‐de‐Campos, D., Santos, C., Amaral, J. S., & Bernardes, J. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.12.037 · Cited by 36
(2025) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000006049 · Cited by 28
Improving the interpretation of electronic fetal monitoring: the fetal reserve index
Evans, M. I., Britt, D. W., Evans, S. M., & Devoe, L. D. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.11.1275 · Cited by 31
Prelabor and intrapartum Doppler ultrasound to predict fetal compromise
DALL’ASTA, A., & Kumar, S. (2021) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2021.100479 · Cited by 28
Steer, P., Kovar, I. Z., McKenzie, C., Griffin, M., & Linsell, L. (2018) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.15535 · Cited by 25
Self-citationKamala, B. A., Kidanto, H. L., Dalen, I., Ngarina, M., Abeid, M. S., Perlman, J. M., & Ersdal, H. L. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16030315 · Cited by 24
Physician views of artificial intelligence in otolaryngology and rhinology: A mixed methods study
Asokan, A., Massey, C. J., Tietbohl, C., Kroenke, K., Morris, M., & Ramakrishnan, V. R. (2023) · Laryngoscope Investigative Otolaryngology · doi:10.1002/lio2.1177 · Cited by 24
Fetal heart rate monitoring in labor: from pattern recognition to fetal physiology
OIKONOMOU, M., & Chandraharan, E. (2021) · Minerva Obstetrics and Gynecology · doi:10.23736/s2724-606x.20.04666-3 · Cited by 25
Aeberhard, J. L., Radan, A., Soltani, R. A., Strahm, K. M., Schneider, S., Carrié, A., Lemay, M., Krauss, J., Delgado-Gonzalo, R., & Surbek, D. (2024) · Methods and Protocols · doi:10.3390/mps7010005 · Cited by 28
Brocklehurst, P., Field, D. J., Juszczak, E., Kenyon, S. L., Linsell, L., Newburn, M., Plachcinski, R., QUIGLEY, M. A., Schroeder, L., & Steer, P. J. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31594-5 · Cited by 23
Self-citationFetal heart rate short term variation during labor in relation to scalp blood lactate concentration
Lu, K., Holzmann, M., Abtahi, F., Lindecrantz, K., Lindqvist, P. G., & Nordström, L. (2018) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13390 · Cited by 23
Lovers, A. A. K., Ugwumadu, A. H. N., & Georgieva, A. (2022) · Frontiers in Pediatrics · doi:10.3389/fped.2022.784439 · Cited by 25
Multimodal Deep Learning for Predicting Adverse Birth Outcomes Based on Early Labour Data
Asfaw, D., Jordanov, I., Impey, L. W. M., Namburete, A. I. L., Lee, R., & Georgieva, A. (2023) · Bioengineering · doi:10.3390/bioengineering10060730 · Cited by 30
Lamé, G., Liberati, E. G., Canham, A., Burt, J., Hinton, L., Draycott, T. J., Winter, C., Dakin, F., Richards, N., Miller, L., et al. (2023) · BMJ Quality & Safety · doi:10.1136/bmjqs-2023-016144 · Cited by 26
Medico-legal considerations and operative vaginal delivery
Murphy, D. J. (2019) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2019.01.012 · Cited by 22
Validation of a computerized algorithm to quantify fetal heart rate deceleration area
Gyllencreutz, E., Lu, K., Lindecrantz, K., Lindqvist, P. G., Nordström, L., Holzmann, M., & Abtahi, F. (2018) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13370 · Cited by 21
Statistical methods for validation of predictive models
Diniz, M. A. (2022) · Journal of Nuclear Cardiology · doi:10.1007/s12350-022-02994-7 · Cited by 24
Cross-Database Evaluation of Deep Learning Methods for Intrapartum Cardiotocography Classification
Mendis, L., Karmakar, D., Palaniswami, M. S., Brownfoot, F., & Keenan, E. (2025) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2025.3548401 · Cited by 24
Principles for evaluating the clinical implementation of novel digital healthcare devices
Park, S. H., Do, K.-H., Choi, J.-I., Sim, J. S., Yang, D. M., Eo, H., Woo, H., Lee, J. M., Jung, S. E., & Oh, J. H. (2018) · Journal of the Korean Medical Association · doi:10.5124/jkma.2018.61.12.765 · Cited by 18
Sartwelle, T. P., & Johnston, J. C. (2018) · The Surgery Journal · doi:10.1055/s-0038-1632404 · Cited by 18
Landman, A. J. E. M. C., Immink-Duijker, S. T., Mulder, E. J. H., Koster, M. P. H., Xodo, S., Visser, G. H. A., Groenendaal, F., & Kwee, A. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2019.02.049 · Cited by 19
Automated interpretation of cardiotocography using deep learning in a nationwide multicenter study
Park, C. E., Choi, B., Park, R. W., Kwak, D. W., Ko, H. S., Seong, W. J., Cha, H., Kim, H. M., Lee, J., Seol, H., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-02849-4 · Cited by 26
Weichert, J., Welp, A., Scharf, J. L., Dracopoulos, C., Becker, W.-H., & Gembicki, M. (2021) · Geburtshilfe und Frauenheilkunde · doi:10.1055/a-1522-3029 · Cited by 19
A fetal heart rate morphological analysis toolbox for MATLAB
Boudet, S., de l’Aulnoit, A. H., Demailly, R., Delgranche, A., Peyrodie, L., Beuscart, R., & de l’Aulnoit, D. H. (2020) · SoftwareX · doi:10.1016/j.softx.2020.100428 · Cited by 17
Hussain, N. M., O’Halloran, M., McDermott, B., & Elahi, A. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad17a6 · Cited by 20
Ranaei‐Zamani, N., David, A. L., Siassakos, D. M., Dadhwal, V., Melbourne, A., Aughwane, R., Russell-Buckland, J., Tachtsidis, I., Hillman, S. L., & Mitra, S. (2024) · npj Women s Health · doi:10.1038/s44294-024-00015-1 · Cited by 20
Liu, L.-C., Tsai, Y.-H., Chou, Y., Jheng, Y.-C., Lin, C., Lyu, N.-Y., Chien, Y., Yang, Y., Chang, K.-J., Chang, K.-H., et al. (2020) · Journal of the Chinese Medical Association · doi:10.1097/jcma.0000000000000416 · Cited by 14
Steer, P. J., Yau, C. W. H., Blott, M., Lattey, K., Nwandison, M., Uddin, Z., Winter, C., & Draycott, T. (2022) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.17302 · Cited by 16
Self-citationClark, S. L. (2022) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000004801 · Cited by 14
Larrain, C. M., Torres-Hernandez, A., & Hewitt, D. B. (2024) · Livers · doi:10.3390/livers4010004 · Cited by 16
Beardmore‐Gray, A., Greenland, M., Linsell, L., Juszczak, E., Hardy, P., Placzek, A., Hunter, R. M., Sparkes, J., Green, M., Shennan, A. H., et al. (2022) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.17167 · Cited by 13
Self-citationA second look at intrapartum fetal surveillance and future directions
Ugwumadu, A. H. N., & Arulkumaran, S. (2022) · Journal of Perinatal Medicine · doi:10.1515/jpm-2022-0292 · Cited by 21
Spector‐Bagdady, K., Vries, R. G. D., Harris, L. H., & Low, L. K. (2017) · The Hastings Center Report · doi:10.1002/hast.781 · Cited by 15
Tending to the machine: The impact of intrapartum fetal surveillance on women in Australia
Fox, D. J., Coddington, R., Levett, K. M., Scarf, V. L., Sutcliffe, K. L., & Newnham, E. C. (2024) · PLoS ONE · doi:10.1371/journal.pone.0303072 · Cited by 12
Monitoring Fetal Electroencephalogram Intrapartum: A Systematic Literature Review
Castel, A., Frank, Y. S., Feltner, J., Karp, F. B., Albright, C. M., & Frasch, M. G. (2020) · Frontiers in Pediatrics · doi:10.3389/fped.2020.00584 · Cited by 12
Computerised cardiotocography—study design hampers findings
Belfort, M. A., & Clark, S. L. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30762-6 · Cited by 12
Frasch, M. G., Boylan, G. B., Wu, H., & Devane, D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00721 · Cited by 12
Xie, W., Cai, P., Hu, Y., Lu, Y., Chen, C., Cai, Z., & Fu, X. (2024) · Neurocomputing · doi:10.1016/j.neucom.2024.128446 · Cited by 11
Sholapurkar, S. L. (2021) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2021.1949453 · Cited by 11
Lee, N., Allen, J., Jenkinson, B., Hurst, C. P., Gao, Y., & Kildea, S. V. (2023) · Women and Birth · doi:10.1016/j.wombi.2023.08.003 · Cited by 11
Lamé, G., Liberati, E. G., Burt, J., Draycott, T. J., Winter, C., Ward, J., & Dixon‐Woods, M. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-030271 · Cited by 18
Intrapartum assessment of fetal well-being
Jayasooriya, G. S., & Djapardy, V. (2017) · BJA Education · doi:10.1093/bjaed/mkx034 · Cited by 11
Hunter, R. M., Beardmore‐Gray, A., Greenland, M., Linsell, L., Juszczak, E., Hardy, P., Placzek, A., Shennan, A. H., Marlow, N., Chappell, L. C., et al. (2022) · PharmacoEconomics - Open · doi:10.1007/s41669-022-00355-1 · Cited by 10
Self-citationHughes, O., & Murphy, D. J. (2020) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2020.1712704 · Cited by 12
Fetal ECG signal processing and identification of hypoxic pregnancy conditions in-utero
Biloborodova, T., Ścisło, Ł., Skarga-Bandurova, I., Sachenko, A., Molga, A., Povoroznyuk, O. A., & Yevsieieva, Y. (2021) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2021250 · Cited by 11
The quality of intrapartum cardiotocography in preterm labour
Faiz, Z., Hof, E. M. V. ‘., Colenbrander, G. J., Lippes, R., & Bakker, P. (2021) · Journal of Perinatal Medicine · doi:10.1515/jpm-2021-0214 · Cited by 13
The INFANT study—a flawed design foreseen
Keith, R. D. F. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30714-6 · Cited by 10
Self-citationLam, M., Chaemsaithong, P., Kwan, A. H. W., Wong, S. T., Tse, W. T., Sahota, D. S., Leung, T. Y., & Poon, L. C. (2020) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2020.1752657 · Cited by 8
Clinical algorithms for management of fetal heart rate abnormalities during labour
Cheung, K. W., Bonet, M., Frank, K., Oladapo, O. T., Hofmeyr, G. J., & the WHO Intrapartum Care Algorithms Working Group (2022) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.16731 · Cited by 11
Olofsson, P., Ekengård, F., & Herbst, A. (2021) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.14201 · Cited by 8
Rivolta, M. W., Barbieri, M., Stampalija, T., Sassi, R., & Frasch, M. G. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.626450 · Cited by 11
Metadata
- Authors
- Brocklehurst, P., Field, D., Greene, K., Juszczak, E., Keith, R., Kenyon, S., Linsell, L., Mabey, C., Newburn, M., Plachcinski, R., Quigley, M., Schroeder, E., & Steer, P.
- Affiliations
- University of Birmingham (GB)
- University of Leicester (GB)
- University College London (GB)
- University of Oxford (GB)
- King's College London (GB)
- National Childbirth Trust (GB)
- ORCID
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 389
- Issue
- 10080
- Pages
- 1719-1729
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- PMC
- PMC5413601
- OpenAlex
- W2603022199
- Cited by
- 207
- References
- 26
- Citations by year
- 2026: 19 · 2025: 14 · 2024: 26 · 2023: 22 · 2022: 25 · 2021: 30 · 2020: 26 · 2019: 16 · 2018: 17 · 2017: 12
- FWCI
- 23.01
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- The Lancet (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Warwick Research Archive Portal (University of Warwick) (acceptedVersion)
- City Research Online (City University London) (acceptedVersion)
- Figshare (submittedVersion, cc-by)
- Leicester Research Archive (University of Leicester) (submittedVersion, cc-by-nc-nd)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion, cc-by)
- Funders
- National Institute for Health and Care Research (06/38/01, WMCLAHRC-2014-1)
- Medical Research Council
- Health Technology Assessment Programme (06.38.01)
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and Neonatal Healthcare
- Keywords
- cardiotocography, decision support software, continuous electronic fetal monitoring, labour, neonatal outcomes, intrapartum stillbirth, neonatal encephalopathy, neonatal intensive care admission, infant development
- MeSH terms
- Adult, Decision Support Techniques, Female, Gestational Age, Heart Rate, Fetal, Humans, Infant, Newborn, Labor, Obstetric, Pregnancy, Pregnancy Outcome, Signal Processing, Computer-Assisted, Cardiotocography, Delivery, Obstetric
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.