STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 13,201–13,300 of 47,868
Engelman, D., Kado, J. H., Reményi, B., Colquhoun, S., Carapetis, J. R., Wilson, N. J., Donath, S. M., & Steer, A. C. (2016) · BMC Cardiovascular Disorders · doi:10.1186/s12872-016-0205-7 · Cited by 38
Tello, J., Cubero, S., Blasco, J., Tardáguila, J., Aleixos, N., & Ibáñez, J. (2016) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.7675 · Cited by 38
Meyer, M. P., Oberhoffer, R., Hock, J., Giegerich, T., & Müller, J. (2016) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.13166 · Cited by 38
Ficial, B., Bonafiglia, E., Padovani, E. M., Prioli, M. A., Finnemore, A. E., Cox, D. J., Broadhouse, K. M., Price, A. N., Durighel, G., & Groves, A. M. (2016) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2015-309523 · Cited by 38
Joffe, R., Duff, J. P., Guerra, G. G., Pugh, J., & Joffe, A. R. (2016) · Critical Care · doi:10.1186/s13054-016-1354-x · Cited by 38
Ability and efficiency of an automatic analysis software to measure microvascular parameters
Carsetti, A., Aya, H. D., Pierantozzi, S., Bazurro, S., Donati, A., Rhodes, A., & Cecconi, M. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9928-3 · Cited by 39
Respiratory rates measured by a standardised clinical approach, ward staff, and a wireless device
Granholm, A., Pedersen, N. E., Lippert, A. M., Petersen, L. F., & Rasmussen, L. S. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12784 · Cited by 38
Robinson, H. S., & Dagfinrud, H. S. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1553-x · Cited by 48
Zheng, R., Hill, D. L., Hedden, D., Mahood, J. K., Moreau, M., Southon, S. H., & Lou, E. (2018) · PLoS ONE · doi:10.1371/journal.pone.0198792 · Cited by 38
Yıldırım, K., & Sağlam-Aydinatay, B. (2018) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2017.12.009 · Cited by 40
Chychyla, R., & Kogan, A. (2014) · Journal of Information Systems · doi:10.2308/isys-50922 · Cited by 38
Prevalence of malocclusion and orthodontic treatment need in 10-year-old New Zealand children
Johnson, M., & Harkness, M. (2000) · Australasian Orthodontic Journal · doi:10.2478/aoj-2000-0001 · Cited by 38
Bayle, C., Issac, C., Salvayre, R., Couderc, F., & Caussé, E. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01504-2 · Cited by 38
Bird, P., Ejbjerg, B., Lassere, M. N., Østergaard, M., McQueen, F. M., PETERFY, C. G., Haavardsholm, E. A., O’Connor, P., Genant, H. K., Edmonds, J. P., et al. (2007) · PubMed · Cited by 38
Validation of optical coherence tomographyin vivousing cryostat histology
Gambichler, T., Moussa, G., Regeniter, P., Kasseck, C., Hofmann, M. R., Bechara, F. G., Sand, M. S., Altmeyer, P. J., & Hoffmann, K. K. P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/5/n01 · Cited by 48
Intraoperative cardiac output monitoring: Comparison of impedance cardiography and thermodilution
Perrino, A. C., Lippman, A., Ariyan, C., O'CONNOR, T., & Luther, M. A. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90007-8 · Cited by 38
Rago, T., Bencivelli, W., Scutari, M., Cosmo, C. D., Rizzo, C., Berti, P., Miccoli, P., Pinchera, A., & Vitti, P. (2006) · Journal of Endocrinological Investigation · doi:10.1007/bf03344125 · Cited by 38
Inaccuracy of glomerular filtration rate estimation from height/plasma creatinine ratio.
Skinner, R., Cole, M. F., Pearson, A. D. J., Keir, M. J., Price, L., Wyllie, R., Coulthard, M. G., & Craft, A. W. (1994) · Archives of Disease in Childhood · doi:10.1136/adc.70.5.387 · Cited by 38
Schalla, S. M., Saeed, M., Higgins, C. B., Weber, O. M., Martin, A. J., & Moore, P. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20267 · Cited by 38
Effect of body mass index on overnight oximetry for the diagnosis of sleep apnea
Nakano, H., Ikeda, T., Hayashi, M., Ohshima, E., Itoh, M., Nishikata, N., & Shinohara, T. (2004) · Respiratory Medicine · doi:10.1016/j.rmed.2003.11.009 · Cited by 38
Carr, D. (2000) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(00)00973-x · Cited by 38
Baldelli, S., Zenoni, S., Merlini, S., Perico, N., & Cattaneo, D. (2005) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.07.019 · Cited by 38
Jose, R. M. J., Bender, L. E., Boyce, J. F., & Heatley, C. J. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.07.022 · Cited by 38
Clinical Use of Continuous Arterial Blood Gas Monitoring in the Pediatric Intensive Care Unit
Weiss, I. K., Fink, S., Harrison, R. E., Feldman, J. D., & Brill, J. E. (1999) · PEDIATRICS · doi:10.1542/peds.103.2.440 · Cited by 38
Improved reliability of ultrasonic surveillance of abdominal aortic aneurysms
Länne, T., Sandgren, T., Mangell, P., Sonesson, B., & Hansen, F. (1997) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(97)80011-1 · Cited by 38
Evaluation of Cardiac Output by Thoracic Electrical Bioimpedance during Exercise in Normal Subjects
Moore, R., Sansores, R. H., Guimond, V., & Abboud, R. T. (1992) · CHEST Journal · doi:10.1378/chest.102.2.448 · Cited by 38
Leslie, W. D., Metge, C. J., & Ward, L. (2003) · Osteoporosis International · doi:10.1007/s00198-003-1375-6 · Cited by 38
A comparison of alternative assessments of depressive symptom severity: a pilot study
Biggs, M. M., Shores‐Wilson, K., Rush, A. J., Carmody, T. J., Trivedi, M. H., Crismon, M. L., Toprac, M. G., & Mason, M. (2000) · Psychiatry Research · doi:10.1016/s0165-1781(00)00159-1 · Cited by 39
Ding, Y., Simpson, P. M., Schellhase, D. E., Tryka, A. F., Ding, L., & Parham, D. M. (2002) · Pediatric and Developmental Pathology · doi:10.1007/s10024-002-0025-x · Cited by 38
Quantitative analysis of the lamina cribrosa in vivo using a scanning laser opthalmoscope
Bhandari, A., Fontana, L., Fitzke, F. W., & Hitchings, R. A. (1997) · Current Eye Research · doi:10.1076/ceyr.16.1.1.5114 · Cited by 39
Interactive Effect of Heart Rate and Muscle Sympathetic Nerve Activity on Blood Pressure
Narkiewicz, K., & Somers, V. K. (1999) · Circulation · doi:10.1161/01.cir.100.25.2514 · Cited by 43
Mansberger, S. L., Johnson, C. A., Cioffi, G. A., Choi, D., Krishnadas, S. R., Srinivasan, M., Balamurugan, V., Kim, U. R., Smith, S. D. G., Wilkins, J. H., et al. (2005) · Journal of Glaucoma · doi:10.1097/01.ijg.0000151883.07232.54 · Cited by 38
Dewey, M., Müller, M., Teige, F., Schnapauff, D., Schink, T., Hamm, B., & Lembcke, A. E. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000201233.42994.9b · Cited by 42
Mercury in UK imported fish and shellfish and UK-farmed fish and their products
Knowles, T. G., Farrington, D., & Kestin, S. C. (2003) · Food Additives & Contaminants · doi:10.1080/0265203031000152398 · Cited by 38
Aoki, S., Haruma, K., Kusunoki, H., Hata, J., Hara, M., Yoshida, S., Tanaka, S., & Chayama, K. (2002) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365520212508 · Cited by 40
Andersen, G. R., Rasmussen, J.-B., Dahl, B., & Solgaard, S. (1991) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679108996645 · Cited by 38
Andresen, M., Mackie, I. C., & Worthington, H. V. (2003) · Dental Traumatology · doi:10.1034/j.1600-9657.2003.00165.x · Cited by 38
Nijkamp, M. D., Sixma, H. J. M., Afman, H., Hiddema, F., Koopmans, S. A., van den Borne, B., Hendrikse, F., & Nuijts, R. M. M. A. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.8.840 · Cited by 38
Wright, G. A., Thackray, S. D. R., Howey, S., & Cleland, J. G. F. (2003) · PubMed · Cited by 38
Westenberg, J. J. M., Danilouchkine, M., Doornbos, J., Bax, J. J., van der Geest, R. J., Labadie, G., Lamb, H. J., Versteegh, M. I. M., Roos, A., & Reiber, J. H. C. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200036108 · Cited by 38
Comparison of histometric data obtained by optical coherence tomography and routine histology
Gambichler, T., Boms, S., Stücker, M., Kreuter, A., Sand, M., Moussa, G., Altmeyer, P., & Hoffmann, K. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2039086 · Cited by 40
Tidal breathing parameters in the first week of life and subsequent cough and wheeze.
Yuksel, B., Greenough, A., Giffin, F., & Nicolaides, K. H. (1996) · Thorax · doi:10.1136/thx.51.8.815 · Cited by 38
Reliability of aortic MRI at 3 Tesla in patients with acute cryptogenic stroke
Harloff, A., Dudler, P., Frydrychowicz, A. P., Strecker, C., Stroh, A. L., Geibel, A., Weiller, C., Hetzel, A., Hennig, J., & Markl, M. (2007) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.125211 · Cited by 38
Lauder, M. A., Dabnichki, P., & Bartlett, R. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00166-4 · Cited by 38
Comparing and predicting between several methods of measurement
Carstensen, B. (2004) · Biostatistics · doi:10.1093/biostatistics/kxg043 · Cited by 38
Ishii, M., Hashino, K., Eto, G., Tsutsumi, T., Himeno, W., Sugahara, Y., Muta, H., Furui, J., Akagi, T., Ito, Y., et al. (2001) · Circulation · doi:10.1161/01.cir.103.5.664 · Cited by 38
Omboni, S., Fogari, R., Palatini, P., RAPPELLI, A., & Mancia, G. (1998) · Hypertension · doi:10.1161/01.hyp.32.3.424 · Cited by 43
SIMONE, G. D., Ganau, A., Roman, M. J., & Devereux, R. B. (1997) · Journal of Hypertension · doi:10.1097/00004872-199715090-00012 · Cited by 38
Pu, M., Griffin, B. P., Vandervoort, P. M., Leung, D. Y., Cosgrove, D. M., & Thomas, J. D. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00259-2 · Cited by 38
Bizouarn, P., Soulard, D., Blanloeil, Y., Guillet, A., & Goarin, Y. (1992) · Intensive Care Medicine · doi:10.1007/bf01709833 · Cited by 38
Cataldo, D. D., Foidart, J.-M., Lau, L. C. K., Bartsch, P., Djukanović, R., & Louis, R. E. (2001) · CHEST Journal · doi:10.1378/chest.120.6.1815 · Cited by 38
The Hyperoxic Test in Infants Reinvestigated
Bouferrache, B., FILTCHEV, S., Leke, A., Marbaix-Li, Q., Freville, M., & Gaultier, C. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.1.9904012 · Cited by 38
Application of machine vision to assess involved surface in patients with psoriasis
Savolainen, L., Kontinen, J., Röning, J., & Oikarinen, A. (1997) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1997.18561949.x · Cited by 43
Examination of the validity and reliability of the accusport blood lactate analyser
Pinnington, H., & Dawson, B. (2001) · Journal of science and medicine in sport · doi:10.1016/s1440-2440(01)80014-1 · Cited by 38
Y., S., Röyttä, M., Rinne, J. O., Collan, Y. U., & Rinne, U. K. (1995) · Neuropathology and Applied Neurobiology · doi:10.1111/j.1365-2990.1995.tb01068.x · Cited by 38
Clinical evaluation of spine morphometric X-ray absorptiometry
Chappard, C., Kolta, S., Fechtenbaum, J., Dougados, M., & Roux, C. (1998) · Rheumatology · doi:10.1093/rheumatology/37.5.496 · Cited by 38
Gabbay, E., Fisher, A., Small, T., Leonard, A., & Corris, P. A. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.11020467 · Cited by 47
Kemperman, F. A. W., Surachno, J. S., Krediet, R. T., & Arisz, L. (2002) · Transplantation · doi:10.1097/00007890-200203150-00020 · Cited by 38
Comparison of single-breath and tidal breathing exhaled nitric oxide levels in infants
Franklin, P., Turner, S., Mutch, R. C., & Stick, S. M. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00084604 · Cited by 39
de Waal, W. J., Vreeburg, J. T. M., Bekkering, F. C., de Jong, F. H., Keizer‐Schrama, S. M. P. F. D. M., Drop, S. L. S., & Weber, R. F. A. (1995) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1995.tb01897.x · Cited by 42
Zighetti, M. L., Chantarangkul, V., Tripodi, A., Mannucci, P. M., & Cattaneo, M. (2002) · PubMed · Cited by 38
Peuhkuri, K., Poussa, T. A., & Korpela, R. (1998) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519850186607 · Cited by 38
Maternal age at menarche and atopy among offspring at the age of 31 years
Xu, B. (2000) · Thorax · doi:10.1136/thorax.55.8.691 · Cited by 38
Can training improve the results with infrared tympanic thermometers?
PETERSEN, M. H., & Hauge, H. (1997) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1997.tb04837.x · Cited by 38
Lin, D., Li-fang, H., & Li, Y. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.034223 · Cited by 38
Clarke, K., Taberner, D. A., THOMSON, J. M., Morris, J. A., & Poller, L. (1992) · Journal of Clinical Pathology · doi:10.1136/jcp.45.1.58 · Cited by 38
Andersen, C. L., & Jensen, F. T. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92202-0 · Cited by 38
Standard Peritoneal Permeability Analysis in Children
Bouts, A. H. M., Davin, J. C., Groothoff, J. W., van Amstel, S. P., Zweers, M. M., & Krediet, R. T. (2000) · Journal of the American Society of Nephrology · doi:10.1681/asn.v115943 · Cited by 38
Berntsen, G., Fønnebø, V. M., Tollan, A., Søgaard, A. J., Joakimsen, R. M., & Magnus, J. H. (2000) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(00)00234-1 · Cited by 38
Mendiola, M. S., El-Khoury, A. E., Castillo, L., Chapman, T. E., & Young, V. R. (1995) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/61.3.555 · Cited by 43
Garratt, A., Ruta, D. A., Russell, I. T., Macleod, K., BRUNT, P. W., McKinlay, A., Mowat, A., & Sinclair, T. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(95)00584-6 · Cited by 41
Woodward, A. M., Jones, A., Zhang, X.-Z., Rowland, J. J., & Kell, D. B. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(96)05065-9 · Cited by 39
Zollinger, A., Spahn, D. R., Singer, T., Zalunardo, M. P., Stoehr, S., Weder, W., & Pasch, T. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.1.47 · Cited by 38
Kupferwasser, I., MOHRKAHALY, S., Stähr, P., Rupprecht, H.-J., Nixdorff, U., Fenster, M., Voigtländer, T., Erbel, R. M., & Meyer, J. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)70044-0 · Cited by 38
A combined approach to reduce mite allergen in the bedroom
Weeks, J., Oliver, J., Birmingham, K. E., Crewes, A., & Carswell, F. (1995) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.1995.tb03041.x · Cited by 38
Faulkner, S. H., Spilsbury, K. L., Harvey, J., Jackson, A., Huang, J., Platt, M., Tok, A., & Nimmo, M. A. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2851-8 · Cited by 37
Does body mass index reflect adequately the body fat content in perimenopausal women?
Kontogianni, M. D., Panagiotakos, D. B., & Skopouli, F. N. (2005) · Maturitas · doi:10.1016/j.maturitas.2004.08.014 · Cited by 37
Sheng, C.-S., Li, Y., Huang, Q.-F., Kang, Y.-Y., Li, F.-K., & Wang, J.-G. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06666 · Cited by 37
Nejatian, A., Yu, J., Geva, T., White, M. T., & Prakash, A. (2015) · Pediatric Cardiology · doi:10.1007/s00246-015-1231-4 · Cited by 37
Saunders, P. U., Ahlgrim, C., Vallance, B., Green, D. J., Robertson, E. Y., Clark, S. A., Schumacher, Y. O., & Gore, C. J. (2010) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.5.4.521 · Cited by 37
Jones, B., Dat, M., & Cooper, C. E. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.12.127002 · Cited by 37
Jimoh, F. O., Bunn, D., & Hooper, L. (2015) · The Journal of nutrition, health and aging · doi:10.1007/s12603-015-0458-3 · Cited by 37
Sotomi, Y., Tateishi, H., Suwannasom, P., Dijkstra, J., Eggermont, J., Liu, S., Tenekecioğlu, E., Zheng, Y., Abdelghani, M., Cavalcante, R., et al. (2016) · International journal of cardiac imaging · doi:10.1007/s10554-016-0856-6 · Cited by 37
A new cone-beam computed tomography–driven index for osteoporosis prediction
de Castro, J. G. K., Carvalho, B. F., de Melo, N. S., Figueiredo, P. T. D. S., Mesquita, C. R. M., Vasconcelos, K. D. F., Jacobs, R., & Leite, A. F. (2020) · Clinical Oral Investigations · doi:10.1007/s00784-019-03193-4 · Cited by 43
Pearce, M., Strain, T., Kim, Y., Sharp, S. J., Westgate, K., Wijndaele, K., Gonzales, T., Wareham, N. J., & Brage, S. (2020) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-020-00937-4 · Cited by 37
Assessing L2 English speaking using automated scoring technology: examining automarker reliability
Xu, J., Jones, E., Laxton, V., & Galaczi, E. D. (2021) · Assessment in Education Principles Policy and Practice · doi:10.1080/0969594x.2021.1979467 · Cited by 49
Wearable Sensor-Based Prediction Model of Timed up and Go Test in Older Adults
Choi, J., Parker, S. M., Knarr, B. A., Gwon, Y., & Youn, J.-H. (2021) · Sensors · doi:10.3390/s21206831 · Cited by 41
Lu, W., Ji, R., Ding, W., Tian, Y., Long, K., Guo, Z., & Leng, L. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.777685 · Cited by 37
Han, E., Fritzer‐Szekeres, M., Szekeres, T., Gehrig, T., Gyöngyösi, M., & Bergler-Klein, J. K. (2022) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfac069 · Cited by 47
Rencz, F., Brodszky, V., & Janssen, M. F. (2023) · Value in Health · doi:10.1016/j.jval.2023.02.002 · Cited by 41
Antonini‐Canterin, F., Leiballi, E., Enache, R., Popescu, B. A., Roşca, M., Cervesato, E., Piazza, R., Ginghină, C., & Nicolosi, G. L. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.01.064 · Cited by 37
Ding, Y., Mason, R. P., McColl, R. W., Yuan, Q., Hallac, R. R., Sims, R. D., & Weatherall, P. T. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24006 · Cited by 41
French, T., Hewlett, S., Kirwan, J., & SANDERSON, T. C. (2013) · Musculoskeletal Care · doi:10.1002/msc.1046 · Cited by 37
Validation of a simple computerized tool for measuring spinal and pelvic parameters
Kim, C. H., Chung, C. K., Hong, H. S., Kim, E. H., Kim, M. J., & Park, B. (2011) · Journal of Neurosurgery Spine · doi:10.3171/2011.10.spine11367 · Cited by 37
Diffusion-weighted MR imaging in assessing cervical tumour response to nonsurgical therapy
Rizzo, S., Summers, P. E., Raimondi, S., Belmonte, M., Maniglio, M., Landoni, F., Colombo, N., & Bellomi, M. (2011) · La radiologia medica · doi:10.1007/s11547-011-0650-4 · Cited by 39
Sweis, B. M., Bachour, S. P., Riedl, J., Gewirtz, J. C., Sadeghi‐Bazargani, H., Hevesi, M., & Divani, A. A. (2015) · Behavioural Brain Research · doi:10.1016/j.bbr.2015.09.015 · Cited by 42
Kording, F., Schoennagel, B. P., Lund, G., Ueberle, F., Jung, C., Adam, G., & Yamamura, J. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25502 · Cited by 39
Software‐assisted small bowel motility analysis using free‐breathing MRI: Feasibility study
Bickelhaupt, S., Froehlich, J. M., Cattin, R., Raible, S., Bouquet, H., Bill, U., & Patak, M. A. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24099 · Cited by 38
James, A. T., Corcoran, J. D., Mertens, L., Franklin, O., & EL-Khuffash, A. F. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.02.015 · Cited by 37
Königsbrügge, O., Quehenberger, P., Belik, S., Weigel, G., Seger, C., Griesmacher, A., Pabinger, I., & Ay, C. (2015) · Annals of Hematology · doi:10.1007/s00277-015-2407-y · Cited by 38
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.