STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 13,601–13,700 of 47,868
Tailor, A., Jurkovic, D., BOURNE, T. H., NATUCCI, M., COLLINS, W. P., & Campbell, S. C. (1998) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00037-4 · Cited by 37
Validation of the sleep EEG headband ZMaxPreprint
Esfahani, M. J., Weber, F. D., Boon, M., Anthes, S., Almazova, T., van Hal, M., Keuren, Y., Heuvelmans, C., Simo, E., Bovy, L., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.08.18.553744 · Cited by 47
Müller, W., Fürhapter-Rieger, A., Ahammer, H., Lohman, T. G., Meyer, N. L., Sardinha, L. B., Stewart, A. D., Maughan, R. J., Sundgot-Borgen, J., Müller, T., et al. (2020) · Sports Medicine · doi:10.1007/s40279-019-01192-9 · Cited by 37
Aucouturier, J., Rance, M., Meyer, M., Isacco, L., Thivel, D., Fellmann, N., Duclos, M., & Duché, P. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0907-3 · Cited by 36
Inter-observer reliability of DSM-5 substance use disorders
Denis, C. M., Gelernter, J., Hart, A. B., & Kranzler, H. R. (2015) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2015.05.019 · Cited by 36
Oshima, Y., Shiga, T., Namba, H., & Kuno, S. (2010) · Obesity Research & Clinical Practice · doi:10.1016/j.orcp.2009.06.001 · Cited by 36
Ma, D., Holmes, H. E., Cardoso, M. J., Modat, M., Harrison, I. F., Powell, N. M., O’Callaghan, J. M., Ismail, O., Johnson, R. A., O’Neill, M. J., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00011 · Cited by 36
Investigating reliability of Reading Mind in the Eyes Test in a Turkish population
Yildirim, E. A., Kasar, M., Guduk, M., Ozalmete, O., Ates, E., & Kucukparlak, I. (2011) · Turkish Journal of Psychiatry · doi:10.5080/u6500 · Cited by 36
Manabe, N., Haruma, K., Kusunoki, H., Kamada, T., & Hata, J. (2017) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.14002 · Cited by 36
Hughes, M. L., Goehring, J. L., Sevier, J. D., & Choi, S. (2018) · Journal of Speech Language and Hearing Research · doi:10.1044/2018_jslhr-h-17-0458 · Cited by 38
Lyu, L., Li, Z., Pan, L., Jia, H., Sun, Q., Liu, Q., & Zhang, Z. (2020) · BMC Infectious Diseases · doi:10.1186/s12879-020-05375-y · Cited by 42
Narang, N., Thibodeau, J. T., Parker, W. F., Grodin, J. L., Garg, S., Tedford, R. J., Levine, B. D., McGuire, D. K., & Drazner, M. H. (2022) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2022.04.026 · Cited by 36
Edanami, K., Kurosawa, M., Yen, H. T., Kanazawa, T., Abe, Y., Kirimoto, T., Yao, Y., Matsui, T., & Sun, G. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107163 · Cited by 39
Rowlands, A. V., Maylor, B. D., Dawkins, N. P., Dempsey, P. C., Edwardson, C. L., Soczawa-Stronczyk, A. A., Bocian, M., Patterson, M., & Yates, T. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2147134 · Cited by 39
Jiménez-García, J., García, M., Gutiérrez‐Tobal, G. C., Gozal, D., Vaquerizo-Villar, F., Álvarez, D., del Campo, F., Gozal, D., & Hornero, R. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105490 · Cited by 42
Half-Life and Clearance of Cardiac Troponin I and Troponin T in Humans
Kristensen, J. H., Hasselbalch, R. B., Strandkjær, N., Jørgensen, N., Østergaard, M., Møller‐Sørensen, H., Nilsson, J. C., Afzal, S., Kamstrup, P. R., Dahl, M., et al. (2024) · Circulation · doi:10.1161/circulationaha.123.066565 · Cited by 42
Chavez, P.-F., Sacré, P., Bleye, C. D., Netchacovitch, L., Mantanus, J., Motte, H., Schubert, M., Hubert, P., & Ziémons, E. (2015) · Talanta · doi:10.1016/j.talanta.2015.08.018 · Cited by 36
Agreement of objectively measured physical activity and sedentary time in preschool children
Aadland, E., & Johannessen, K. (2015) · Preventive Medicine Reports · doi:10.1016/j.pmedr.2015.07.009 · Cited by 42
Bové, T., Bouchez, S., Hert, S. G. D., Wouters, P. F., Somer, F. M. J. J. D., Devos, D., Somers, P., & Nooten, G. V. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.035 · Cited by 42
A meta-analysis of the performance of the PimaTM CD4 for point of care testing
Scott, L. E., Campbell, J., Westerman, L. E., Kestens, L., Vojnov, L., Kohastsu, L., Nkengasong, J. N., PETER, T. F., & Stevens, W. S. (2015) · BMC Medicine · doi:10.1186/s12916-015-0396-2 · Cited by 36
José, A., & Corso, S. D. (2015) · Brazilian Journal of Physical Therapy · doi:10.1590/bjpt-rbf.2014.0092 · Cited by 36
Silvestre, D., Fraga, M., Gormáz, M., Torres‐Martinez, E., & Vento, M. (2012) · Maternal and Child Nutrition · doi:10.1111/j.1740-8709.2012.00431.x · Cited by 36
Robles, N., Rajmil, L., Rodríguez-Arjona, D., Azuara, M., Codina, F. N., Raat, H., Ravens‐Sieberer, U., & Herdman, M. (2015) · Health and Quality of Life Outcomes · doi:10.1186/s12955-015-0271-z · Cited by 43
Semi-automated identification of cones in the human retina using circle Hough transform
Sampson, D. M., Chew, A. L., Huynh, E., Kashani, I., Wan, S. L., Wan, P. M., & Chen, F. K. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004676 · Cited by 37
Wakefield, C. B., Halls, A., Difilippo, N., & Cottrell, G. T. (2015) · Journal of Athletic Training · doi:10.4085/1062-6050-50.2.05 · Cited by 36
Strain Assessment in Surgically Resected Inflammatory and Neoplastic Bowel Lesions
Havre, R. F., Leh, S. M., Gilja, O. H., Ødegaard, S., Waage, J., Baatrup, G., & Nesje, L. B. (2012) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0032-1325535 · Cited by 37
Yoshinaga, K., Manabe, O., Katoh, C., Chen, L., Klein, R., Naya, M., deKemp, R. A., Williams, K., Beanlands, R. S., & Tamaki, N. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1541-y · Cited by 36
Pedersen, P. J., Kanters, J. K., Buhl, R., & Klaerke, D. A. (2013) · Journal of Veterinary Cardiology · doi:10.1016/j.jvc.2012.08.002 · Cited by 37
Ettienne, R., Boushey, C. J., Au, D., Murphy, S. P., Lim, U., & Wilkens, L. R. (2013) · Procedia Food Science · doi:10.1016/j.profoo.2013.04.021 · Cited by 45
Systolic versus Diastolic Acquisition in Myocardial Perfusion MR Imaging
Motwani, M., Fairbairn, T. A., Larghat, A. M., Mather, A. N., Biglands, J. D., Radjenovic, A., Greenwood, J. P., & Plein, S. (2012) · Radiology · doi:10.1148/radiol.11111549 · Cited by 36
Sindall, P., Lenton, J. P., Whytock, K., Tolfrey, K., Oyster, M. L., Cooper, R. A., & Goosey-Tolfrey, V. L. (2013) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000068 · Cited by 36
Feasibility of using finger arterial pressure in neonates
Drouin, E., Gournay, V., Calamel, J., Mouzard, A., & Rozé, J. (1997) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.77.2.f139 · Cited by 39
Theodor, M., Fiala, J., Ruh, D., Förster, K., Heilmann, C., Beyersdorf, F., Manoli, Y., Zappe, H. P., & Seifert, A. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.12.006 · Cited by 38
Zehnder, P., Roth, B., Burkhard, F. C., & Kessler, T. M. (2008) · The Journal of Urology · doi:10.1016/j.juro.2008.05.028 · Cited by 36
Finding the peak velocity in a flow from its doppler spectrum
Vilkomerson, D. H. R., Ricci, S., & Tortoli, P. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2798 · Cited by 36
Bovens, S. M., Boekhorst, B. C. M. T., den Ouden, K., van de Kolk, K. W. A., Nauerth, A., Nederhoff, M. G. J., Pasterkamp, G., ten Hove, M., & van Echteld, C. J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1593 · Cited by 36
Braun, T., Schulz, R. J., Reinke, J. M., van Meeteren, N. L. U., de Morton, N. A., Davidson, M., Thiel, C., & Grüneberg, C. (2015) · BMC Geriatrics · doi:10.1186/s12877-015-0035-y · Cited by 42
NISHIYAMA, T., Nakamura, S., & Yamashita, K. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021506001116 · Cited by 37
Continuous intra-arterial blood pH monitoring in rabbits with acid–base disorders
Jin, W., Jiang, J., Wang, X., Zhu, X., Wang, G., Song, Y., & Bai, C. (2011) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2011.03.009 · Cited by 36
Miyanishi, K., Nagamine, R., Murayama, S., Miura, H., Urabe, K., Matsuda, S., Hirata, G., & Iwamoto, Y. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317411898 · Cited by 38
Hollen, P. J., Gralla, R. J., Stewart, J. A., Meharchand, J. M., Wierzbicki, R. F., & Leighl, N. B. (2012) · Supportive Care in Cancer · doi:10.1007/s00520-012-1507-7 · Cited by 36
Villafañe, J. H., Valdes, K. A., Vanti, C., Pillastrini, P., & Borboni, A. (2014) · Hand · doi:10.1007/s11552-014-9678-y · Cited by 38
Morais, J. E., Costa, M. J., Mejias, J. E., Marinho, D. A., Silva, A. J., & Barbosa, T. M. (2011) · Journal of Human Kinetics · doi:10.2478/v10078-011-0017-x · Cited by 36
Mallat, J., Barrailler, S., Lemyze, M., Pepy, F., Gasan, G., Tronchon, L., & Thévenin, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056635 · Cited by 40
Peebo, B. B., Fagerholm, P., Traneus-Röckert, C., & Lagali, N. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6101 · Cited by 36
Gao, S. A., Johansson, M., Hammar�n, A., Nordberg, M. E., & Friberg, P. (2005) · Clinical Autonomic Research · doi:10.1007/s10286-005-0224-4 · Cited by 39
Seckeler, M. D., Hirsch, R., Beekman, R. H., & Goldstein, B. H. (2014) · Heart · doi:10.1136/heartjnl-2014-306378 · Cited by 36
Pilch, M., Wenner, Y., Strohmayr, E., Preising, M. N., Friedburg, C., zu Bexten, E. M., Lorenz, B., & Stieger, K. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001478 · Cited by 36
Huang, J., Pekmezci, M., Yaplee, S., & Lin, S. C. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-010-1360-7 · Cited by 36
Reproducibility of isokinetic peak torque assessments of the hip flexor and extensor muscles
Julia, M., Dupeyron, A., Laffont, I., Parisaux, J.-M., Lemoine, F., Bousquet, P., & Hérisson, C. (2010) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2010.05.002 · Cited by 36
Grating Acuity and Contrast Tests for Clinical Trials of Severe Vision Loss
Bittner, A. K., Jeter, P., & Dagnelie, G. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182271638 · Cited by 36
Cabrita, I. Z., Ruisanchez, C., Dawson, W. O., Grapsa, J., North, B. V., Howard, L., Pinto, F. J., Nihoyannopoulos, P., & Gibbs, J. S. R. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq051 · Cited by 36
An evaluation of the IDEEA™ activity monitor for estimating energy expenditure
Whybrow, S., Ritz, P., Horgan, G. W., & Stubbs, R. J. (2012) · British Journal Of Nutrition · doi:10.1017/s0007114512000645 · Cited by 40
Overestimation of carboplatin doses is avoided by radionuclide GFR measurement
Craig, A. J., Samol, J., Heenan, S. D., Irwin, A. G., & Britten, A. J. (2012) · British Journal of Cancer · doi:10.1038/bjc.2012.393 · Cited by 36
Pulmonary Nodule Size Evaluation with Chest Tomosynthesis
Johnsson, Å. A., Fagman, E., Vikgren, J., Fisichella, V. A., Boijsen, M., Flinck, A., Kheddache, S., Svalkvist, A., & Båth, M. (2012) · Radiology · doi:10.1148/radiol.12111459 · Cited by 36
Albertsen, A. E., Nielsen, J. C., Poulsen, S. H., Mortensen, P. T., Pedersen, A. K., HANSEN, P. S., Jensen, H. K., & Egeblad, H. (2008) · EP Europace · doi:10.1093/europace/eum279 · Cited by 39
Xiong, J., Tan, W., Pan, J., Wang, Y., Yin, B., Zhang, J., & Geng, D. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24958 · Cited by 39
Bloom, B., Pott, J., Freund, Y., Gründlingh, J., & Harris, T. (2014) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2014.03.007 · Cited by 37
Savini, G., Calossi, A., Camellin, M., Carones, F., Fantozzi, M., & Hoffer, K. J. (2014) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2013.11.032 · Cited by 36
Inter-operator and inter-device agreement and reliability of the SEM Scanner
Clendenin, M., Jaradeh, K., Shamirian, A., & Rhodes, S. L. (2015) · Journal of Tissue Viability · doi:10.1016/j.jtv.2015.01.003 · Cited by 36
Evaluation of 2 electronic handheld devices for diagnosis of ketonemia and glycemia in dairy goats
Pichler, M., Damberger, A., Arnholdt, T., Schwendenwein, I., Gasteiner, J., Drillich, M., & Iwersen, M. (2014) · Journal of Dairy Science · doi:10.3168/jds.2014-8198 · Cited by 36
Griffith, S. D., Shiffman, S. S., & Heitjan, D. F. (2009) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntp150 · Cited by 39
Garcia, J., Lagarde, N., Edward, S. K., de Jong, M. D., & Peiris, M. J. S. (2009) · Journal of Clinical Virology · doi:10.1016/j.jcv.2009.10.009 · Cited by 43
Ross, A. B., Svelander, C. A., Savolainen, O. I., Lind, M. V., Kirwan, J. P., Breton, I., Godin, J., & Sandberg, A. (2016) · Analytical Biochemistry · doi:10.1016/j.ab.2015.12.023 · Cited by 40
Jaggernath, M., Naicker, R., Madurai, S., Brockman, M. A., Ndung’u, T., & Gelderblom, H. C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0152184 · Cited by 39
Bao, F., Wang, Q., Cheng, S., Savini, G., Lu, W., Feng, Y., Yu, Y., & Huang, J. (2014) · Cornea · doi:10.1097/ico.0000000000000113 · Cited by 36
Papazian, T., Hout, H., Sibai, D., Helou, N. E., Younes, H., Osta, N. E., & Khabbaz, L. R. (2016) · Clinical Nutrition · doi:10.1016/j.clnu.2016.04.015 · Cited by 45
van Nunen, L. X., Lenders, G. D., Schampaert, S., Veer, M. V. ’., Wijnbergen, I., Brueren, G. R. G., Tonino, P. A. L., & Pijls, N. H. J. (2015) · EuroIntervention · doi:10.4244/eijy14m08_10 · Cited by 36
Torelli, L., Bella, Z. I. K. D. J. D., Rodrigues, C. A., Stüpp, L., Girão, M. J. B. C., & Sartori, M. G. F. (2016) · International Urogynecology Journal · doi:10.1007/s00192-016-3037-1 · Cited by 36
Soroko, M., Howell, K. J., Zwyrzykowska-Wodzińska, A., Dudek, K. D., Zielińska, P., & Kupczyński, R. (2016) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2016.06.005 · Cited by 46
Moving Forward with Backward Compatibility: Translating Wrist Accelerometer Data
ROWLANDS, A. V., CLIFF, D. P., FAIRCLOUGH, S. J., BODDY, L. M., OLDS, T. S., PARFITT, G., NOONAN, R. J., DOWNS, S. J., KNOWLES, Z. R., & BEETS, M. W. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001015 · Cited by 36
The effect of proficiency level on measurement error of range of motion
Akizuki, K., Yamaguchi, K., Morita, Y., & Ohashi, Y. (2016) · Journal of Physical Therapy Science · doi:10.1589/jpts.28.2644 · Cited by 36
Xue, H., Yang, M., Liu, Y., Duan, R., Cheng, G., & Zhang, X. (2016) · Nutrition & Dietetics · doi:10.1111/1747-0080.12315 · Cited by 37
Tesche, C., Cecco, C. N. D., Vliegenthart, R., Albrecht, M. H., Varga‐Szemes, Á., Duguay, T. M., Ebersberger, U., Bayer, R. R., Canstein, C., Schmidt, B. T., et al. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2016.10.051 · Cited by 39
Validity of Actigraphy in Measurement of Sleep in Young Adults With Type 1 Diabetes
Farabi, S. S., Quinn, L. T., & Carley, D. W. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6580 · Cited by 37
Zeng, J., Xiong, D., Pang, Y., Zhang, Y., Tang, R., Luo, D., & Chen, G. (2017) · Oncotarget · doi:10.18632/oncotarget.16051 · Cited by 39
Dumont, C., Galli, E., Oger, E., Fournet, M., Flecher, E. M., Leclercq, C., Verhoye, J., & Donal, E. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex031 · Cited by 36
Torjesen, A. A., Istfan, R., & Roblyer, D. M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.3.036009 · Cited by 38
Beckers, M., Mohorianu, I. I., Stocks, M. B., Applegate, C., Dalmay, T., & Moulton, V. (2017) · RNA · doi:10.1261/rna.059360.116 · Cited by 40
McLean, B., Taylor, S. L., Blair, E. M., Valentine, J. P., Carey, L. M., & Elliott, C. M. (2017) · American Journal of Occupational Therapy · doi:10.5014/ajot.2016.024968 · Cited by 39
The role of stride frequency for walk-to-run transition in humans
Hansen, E. A., Kristensen, L. A. R., Nielsen, A. M., Voigt, M., & Madeleine, P. (2017) · Scientific Reports · doi:10.1038/s41598-017-01972-1 · Cited by 43
de Albuquerque, P. L., Guerra, M. Q. D. F., Lima, M. D. C., & Eickmann, S. H. (2017) · Developmental Neurorehabilitation · doi:10.1080/17518423.2017.1323974 · Cited by 42
Ishii, K., Shibata, A., Kurita, S., Yano, S., Inoue, S., Sugiyama, T., Owen, N. G., & Oka, K. (2017) · Journal of Epidemiology · doi:10.2188/jea.je20170002 · Cited by 36
Rasmussen, C. D. N., Holtermann, A., & Jørgensen, M. B. (2017) · Spine · doi:10.1097/brs.0000000000002457 · Cited by 49
Wang, Y., Liu, Z., & Ma, S. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aa996d · Cited by 41
Stoelinga, B., Hehenkamp, W. J. K., Nieuwenhuis, L. L., Conijn, M. M. A., van Waesberghe, J. T. M., Brölmann, H. A. M., & Huirne, J. A. F. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.03.027 · Cited by 36
Reyes, A. D. L., & Langer, D. A. (2018) · Journal of Clinical Child & Adolescent Psychology · doi:10.1080/15374416.2018.1458314 · Cited by 39
Kamiya, K., Kono, Y., Takahashi, M., & Shoji, N. (2018) · Scientific Reports · doi:10.1038/s41598-018-31008-1 · Cited by 36
Tinsley, G. M., Graybeal, A. J., & Moore, M. L. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2018-0412 · Cited by 44
Osteosynthesis with Parallel Implants in the Treatment of Femoral Neck Fractures:
Nyholm, A. M., Palm, H., Sandholdt, H., Troelsen, A., Gromov, K., & Collaborators, T. D. F. D. (2018) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.18.00270 · Cited by 36
Reliability of short-term measurements of heart rate variability: Findings from a longitudinal study
Uhlig, S., Meylan, A., & Rudolph, U. (2020) · Biological Psychology · doi:10.1016/j.biopsycho.2020.107905 · Cited by 41
Performance of PROMIS Global-10 Compared With Legacy Instruments for Rotator Cuff Disease
Nicholson, A. D., Kassam, H. F., Pan, S. D., Berman, J. E., Blaine, T. A., & Kovacevic, D. (2018) · The American Journal of Sports Medicine · doi:10.1177/0363546518810508 · Cited by 39
Congruent Validity of Resting Energy Expenditure Predictive Equations in Young Adults
Amaro‐Gahete, F. J., Sánchez‐Delgado, G., Alcántara, J. M. A., Martínez‐Téllez, B., Muñoz-Hernández, V., Merchán-Ramírez, E., Löf, M., Labayen, I., & Ruiz, J. R. (2019) · Nutrients · doi:10.3390/nu11020223 · Cited by 39
Development of an Automatic Alpine Skiing Turn Detection Algorithm Based on a Simple Sensor Setup
Martínez, A., Jahnel, R., Buchecker, M., Snyder, C., Brunauer, R., & STÖGGL, T. L. (2019) · Sensors · doi:10.3390/s19040902 · Cited by 36
Valkenet, K., Bor, P., van Delft, L., & Veenhof, C. (2019) · Clinical Rehabilitation · doi:10.1177/0269215519836454 · Cited by 40
Factor associated with alcohol use among Lahu and Akha hill tribe youths, northern Thailand
Singkorn, O., Apidechkul, T., Putsa, B., Detpetukyon, S., Sunsern, R., Thutsanti, P., Tamornpark, R., Upala, P., & Inta, C. (2019) · Substance Abuse Treatment Prevention and Policy · doi:10.1186/s13011-019-0193-6 · Cited by 42
Paraspinal Muscle Segmentation Based on Deep Neural Network
Li, H., Luo, H., & Liu, Y. (2019) · Sensors · doi:10.3390/s19122650 · Cited by 37
Translational optical coherence elastography for assessment of systemic sclerosis
Liu, C., Assassi, S., Theodore, S., Smith, C., Schill, A., Singh, M., Aglyamov, S. R., Mohan, C., & Larin, K. V. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201900236 · Cited by 40
Patey, O. V., Carvalho, J. S., & Thilaganathan, B. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.05.023 · Cited by 36
Development and Validation of a Smartphone-based Contrast Sensitivity Test
Habtamu, E., Bastawrous, A., Bolster, N. M., Tadesse, Z., Callahan, E. K., Gashaw, B., Macleod, D., & Burton, M. J. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.5.13 · Cited by 36
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.