STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 16,101–16,200 of 47,868
Reliability and validity of the L test in participants with chronic stroke
Kim, J. S., Chu, D. Y., & Jeon, H. (2014) · Physiotherapy · doi:10.1016/j.physio.2014.09.003 · Cited by 36
Comparaison de deux méthodes de mesure d'une même grandeur : méthode de Bland et Altman
Grenier, B., Dubreuil, M., & Journois, D. (2000) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/s0750-7658(00)00109-x · Cited by 44
cp-R, an interface the R programming language for clinical laboratory method comparisons
Holmes, D. T. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.10.015 · Cited by 30
Effects of Diet and Weight Gain on Body Condition Scoring in Thoroughbred Geldings
Suagee, J. K., Burk, A. O., Quinn, R. W., Petersen, E. D., Hartsock, T. G., & Douglass, L. W. (2008) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2008.01.019 · Cited by 30
Harel, F., Finnerty, V., Grégoire, J. C., Thibault, B., Marcotte, F., Ugolini, P., & Khairy, P. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9195-5 · Cited by 30
Lotti, G. A., Braschi, A., Brunner, J. X., Palo, A., & Olivet, M. C. (1995) · CHEST Journal · doi:10.1378/chest.108.1.208 · Cited by 33
Real-Time Rapid Acuity Assessment Using VEPs: Development and Validation of the Step VEP Technique
Mackay, A. M., Bradnam, M. S., Hamilton, R., Elliot, A. T., & Dutton, G. N. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0944 · Cited by 30
Standards of Measurements in Myasthenia Gravis
Gajdos, P., Sharshar, T., & Chevret, S. (2003) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1254.058 · Cited by 30
Sohn, E. H., Chen, J. J., Lee, K., Niemeijer, M., Milan Sonka, A., & Abràmoff, M. D. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10420 · Cited by 30
Takacs, J., Carpenter, M. G., Garland, S. J., & Hunt, M. A. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.016 · Cited by 30
Vincent, J. I., MacDermid, J. C., Grewal, R. S., Sekar, V. P., & Balachandran, D. (2014) · The Open Orthopaedics Journal · doi:10.2174/1874325001408010011 · Cited by 37
Zhang, Y., Dufield, D. R., Klover, J. A., Li, W., Szekely‐Klepser, G., Lepsy, C. S., & Sadagopan, N. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.063 · Cited by 30
Gartner, A., Dioum, A., Delpeuch, F., Maire, B., & Schutz, Y. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601839 · Cited by 32
Nardozza, L. M. M., Rôlo, L. C., Júnior, E. A., Hatanaka, A. R., Rocha, L. A., Simioni, C., Ruano, R., & Moron, A. F. (2013) · Fetal Diagnosis and Therapy · doi:10.1159/000345650 · Cited by 30
Harmonization of molecular monitoring of chronic myeloid leukemia therapy in Japan
Yoshida, C., Fletcher, L., Ohashi, K., Wakita, H., Kumagai, T., Shiseki, M., Matsuei, K., Inokuchi, K., Hatta, Y., Shirasugi, Y., et al. (2011) · International Journal of Clinical Oncology · doi:10.1007/s10147-011-0328-x · Cited by 30
Myocardial T1 and T2 mapping in diastolic and systolic phase
Tessa, C., Diciotti, S., Landini, N., Lilli, A., Meglio, J. D., Salvatori, L., Giannelli, M., Greiser, A., Vignali, C., & Casolo, G. (2015) · International journal of cardiac imaging · doi:10.1007/s10554-015-0639-5 · Cited by 30
TO, K., CHAN, W., CHAN, T., TUNG, A., NGAI, J., NG, S., CHOO, K., & HUI, D. S. (2009) · Respirology · doi:10.1111/j.1440-1843.2008.01439.x · Cited by 30
Anorexia nervosa and nutritional assessment: contribution of body composition measurements
Mattar, L., Godart, N. T., Melchior, J. C., & Pichard, C. (2011) · Nutrition Research Reviews · doi:10.1017/s0954422410000284 · Cited by 36
A New Modular Chemiluminescence Immunoassay Analyser Evaluated
Ognibene, A., Drake, C. J., Jeng, K.-Y. S., Pascucci, T. E., Hsu, S., Luceri, F., & Messeri, G. (2000) · cclm · doi:10.1515/cclm.2000.037 · Cited by 30
Ahmed, M., Mostafa, S., Fisher, G., & Reynolds, T. (2009) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009072 · Cited by 30
Cardiac output during liver transplantation
Colbert, S., O'Hanlon, D. M., Duranteau, J., & Ecoflfey, C. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013251 · Cited by 30
Luque, V., Escribano, J., Zaragoza-Jordana, M., Rubio-Torrents, C., Ferré, N., Gispert‐Llauradó, M., Closa‐Monasterolo, R., & for the European Childhood Obesity Project Group (2014) · Annals of Nutrition and Metabolism · doi:10.1159/000363252 · Cited by 32
Computed Tomographic Angiography in Acute Pulmonary Embolism
Kamel, E. M., Schmidt, S., Doenz, F., Adler, G., Schnyder, P. A., & Qanadli, S. D. (2008) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e3180ca7818 · Cited by 30
The diagnostic value of endothelial function as a potential sensor of fatigue in health
Hashiguchi, T., Ohno, Y., Hashiguchi, T., Maenosono, R., Yamashita, H., Taira, Y., Yamashita, Y., Minowa, K., Kato, Y., Kawahara, K., et al. (2010) · Vascular Health and Risk Management · doi:10.2147/vhrm.s8950 · Cited by 31
Difference of Gaussians revolved along elliptical paths for ultrasound fetal head segmentation
Foi, A., Maggioni, M., Pepe, A., Rueda, S., Noble, J. A., Papageorghiou, A. T., & Tohka, J. (2014) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2014.09.006 · Cited by 31
Use of the Concordance Correlation Coefficient When Examining Agreement in Dyadic Research
Quinn, C., Haber, M. J., & Pan, Y. (2009) · Nursing Research · doi:10.1097/nnr.0b013e3181b4b93d · Cited by 30
Perry, J., Green, A. S., Singh, S. J., & Watson, P. (2010) · Manual Therapy · doi:10.1016/j.math.2010.10.008 · Cited by 40
A critical appraisal of quantitative arthroscopy as an outcome measure in osteoarthritis of the knee
Oakley, S. P., & Lassere, M. N. (2003) · Seminars in Arthritis and Rheumatism · doi:10.1016/s0049-0172(03)00082-9 · Cited by 30
Bergonzi, R., Palma, G. D., Tomasi, C., Ricossa, M. C., & Apostoli, P. (2009) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-009-0426-5 · Cited by 30
Reproducibility of instrumented knee joint laxity measurement in healthy subjects
van der Esch, M., Steultjens, M. P. M., Ostelo, R., Harlaar, J., & Dekker, J. (2005) · Rheumatology · doi:10.1093/rheumatology/kei243 · Cited by 32
Ignjatović, V., Barnes, C. D., Newall, F. H., Hamilton, S., Burgess, J., & Monagle, P. (2004) · Thrombosis and Haemostasis · doi:10.1160/th04-02-0085 · Cited by 30
Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest
Querfurth, H. W., LIEBERMAN, P. H., Arms, S., Mundell, S., Bennett, M. C., & van Horne, C. G. (2010) · BMC Neurology · doi:10.1186/1471-2377-10-106 · Cited by 34
Barnett, B. H., Nunberg, S., Tai, J. Y., LESSER, M. L., Fridman, V., Nichols, P., Powell, R., & Silverman, R. A. (2011) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2011.2.1963 · Cited by 36
Ray, J. G., Post, J. R., & Hamielec, C. M. (2001) · Critical Care · doi:10.1186/cc1456 · Cited by 30
Validity of two-component models for estimating body fat of black men
Wagner, D. R., & Heyward, V. H. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.649 · Cited by 34
Demir, H., Tan, Y. Z., Kozdağ, G., İșgören, S., Yonca Akgoz, A. N. I. K., Ural, D., Demırcı, A., & Berk, F. (2007) · Annals of Saudi Medicine · doi:10.4103/0256-4947.51453 · Cited by 30
Perné, A., Zhang, X., Lehmann, L. E., Groth, M., Stüber, F., & Book, M. (2009) · BioTechniques · doi:10.2144/000113300 · Cited by 31
Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes
Fensli, R. W., GUNDERSEN, T., Snaprud, T., & Hejlesen, O. K. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.03.002 · Cited by 34
Boden, L., Parkin, T. D. H., Yates, J., Mellor, D. J., & Kao, R. R. (2012) · BMC Veterinary Research · doi:10.1186/1746-6148-8-43 · Cited by 30
Gweon, H. M., Kim, S. J., Kim, T., Lee, S. M., Hong, Y. J., & Rim, S. (2010) · Korean Journal of Radiology · doi:10.3348/kjr.2010.11.3.286 · Cited by 30
Determination of C-Reactive Protein: Comparison of Three High-Sensitivity Immunoassays
Khuseyinova, N., Imhof, A., Trischler, G., Rothenbacher, D., Hutchinson, W. L., Pepys, M. B., & Köenig, W. (2003) · Clinical Chemistry · doi:10.1373/49.10.1691 · Cited by 37
Stability of common biochemistry analytes in equine blood stored at room temperature
Rendle, D. I., Heller, J., Hughes, K., Innocent, G. T., & Durham, A. E. (2009) · Equine Veterinary Journal · doi:10.2746/042516409x370928 · Cited by 34
Boyle, M., Steel, L., Flynn, G. M., Murgo, M., Nicholson, L., O’Brien, M., & Bihari, D. J. (2009) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01556-9 · Cited by 30
Galema, T. W., Geleijnse, M., Yap, S., VANDOMBURG, R., Biagini, E., VLETTER, W., & ten Cate, F. J. (2007) · European Journal of Echocardiography · doi:10.1016/j.euje.2007.03.025 · Cited by 30
Frankenstein, L., Remppis, A., Frankenstein, J., Heß, G., Zdunek, D., Slottje, K., Katus, H. A., & Zugck, C. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112052 · Cited by 30
Masci, P. G., Dymarkowski, S., Rademakers, F. E., & Bogaert, J. G. (2008) · Radiology · doi:10.1148/radiol.2493080340 · Cited by 30
Improved accuracy in flow mapping of congenital heart disease using stationary phantom technique
Miller, T. A., Landes, A., & Moran, A. M. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-52 · Cited by 30
Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography
Schepis, T., Koepfli, P., Leschka, S., Desbiolles, L. M., Husmann, L., Gaemperli, O., Eberli, F. R., Wildermuth, S., Marinček, B., Lüscher, T. F., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0502-0 · Cited by 30
Sotgia, S., Pisanu, E., Pintus, G., Erre, G. L., Pinna, G. A., Deiana, L., Carru, C., & Zinellu, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070374 · Cited by 33
Concordance between capnography and capnia in adults admitted for acute dyspnea in an ED
Delerme, S., Freund, Y., Renault, R., Devilliers, C., Castro, S., Chopin, S., Juillien, G., Riou, B., & Ray, P. (2010) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2009.04.028 · Cited by 30
Tonan, T., Fujimoto, K., Qayyum, A., Morita, Y., Nakashima, O., Ono, N., Kawahara, A., Kage, M., Hayabuchi, N., & Ueno, T. (2011) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.2011.07057.x · Cited by 33
Berger‐Achituv, S., Budde‐Schwartzman, B., Ellis, M. H., Shenkman, Z., & Erez, I. (2010) · PEDIATRICS · doi:10.1542/peds.2009-2920 · Cited by 30
Developmental Morphology and Ossification Patterns of the C1 Vertebra
Rao, R. D., Tang, S., Lim, C. Y., & Yoganandan, N. (2013) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.l.01035 · Cited by 30
Wibmer, T., Rüdiger, S., Scharnbeck, D., Radermacher, M., Markovic, S., Stoiber, K., Rottbauer, W., & Schumann, C. (2014) · Echocardiography · doi:10.1111/echo.12772 · Cited by 30
Varga‐Szemes, Á., van der Geest, R. J., Spottiswoode, B. S., Suranyi, P. S., Ruzsics, B., Cecco, C. N. D., Muscogiuri, G., Cannaò, P. M., Fox, M. A., Wichmann, J. L., et al. (2015) · Radiology · doi:10.1148/radiol.2015150162 · Cited by 30
Evaluation of an Automated Subjective Refractor
Sheedy, J. E., Schanz, P., & Bullimore, M. A. (2004) · Optometry and Vision Science · doi:10.1097/01.opx.0000134907.06027.b0 · Cited by 30
Madsen, O. R. (2013) · The Journal of Rheumatology · doi:10.3899/jrheum.120594 · Cited by 30
Tarkiainen, T. H., Kuusela, T., Tahvanainen, K. U. O., Hartikainen, J. E. K., Tiittanen, P., Timonen, K. L., & Vanninen, E. J. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00726.x · Cited by 30
Reproducibility and age-related changes of ocular parametric measurements in rabbits
Riau, A. K., Tan, N. Y. S., Angunawela, R. I., Htoon, H. M., Chaurasia, S. S., & Mehta, J. S. (2012) · BMC Veterinary Research · doi:10.1186/1746-6148-8-138 · Cited by 30
Midena, E., Cortese, M., Miotto, S., Gambato, C., Cavarzeran, F., & Ghirlando, A. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20090115-09 · Cited by 34
MArray: analysing single, replicated or reversed microarray experiments
Wang, J., Nygaard, V., Smith‐Sørensen, B., Hovig, E. J., & Myklebost, O. (2002) · Bioinformatics · doi:10.1093/bioinformatics/18.8.1139 · Cited by 30
Comparison of Direct Body Composition Assessment Methods in Patients With Chronic Heart Failure
Oreopoulos, A., Kalantar‐Zadeh, K., McAlister, F. A., Ezekowitz, J. A., Fonarow, G. C., Johnson, J. A., Norris, C. M., & Padwal, R. S. (2010) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2010.06.416 · Cited by 33
Gonska, T. Y., Ip, W., Turner, D., Han, W. S., Rose, J. V., Durie, P. R., & Quinton, P. (2009) · Thorax · doi:10.1136/thx.2009.115295 · Cited by 32
Tueni, M., Mounayar, A., & Birlouez‐Aragon, I. (2012) · Public Health Nutrition · doi:10.1017/s1368980012000171 · Cited by 40
Dulce, M.-C., Steffen, I. G., Preuss, A., Renz, D. M., Hamm, B., & Elgeti, T. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet341 · Cited by 30
Actigraphy combined with EEG compared to polysomnography in sleep apnea patients
Fietze, I., Penzel, T., Partinen, M., Sauter, J., Küchler, G., Suvoro, A., & Hein, H. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/385 · Cited by 33
Castillo, R., Pham, N. T. T., Castillo, E. M., Aso-González, S., Ansari, S. J., Hobbs, B. P., Palacio, D. M., Skinner, H. D., & Guerrero, T. M. (2015) · Radiology · doi:10.1148/radiol.14140457 · Cited by 32
Accuracy of Self-Reported Physical Activity Levels in Obese Adolescents
Elliott, S. A., Baxter, K. A., Davies, P. S. W., & Truby, H. (2014) · Journal of Nutrition and Metabolism · doi:10.1155/2014/808659 · Cited by 35
Saur, J., Trinkmann, F., Doesch, C., Scherhag, A. W., Brade, J., Schoenberg, S. O., Borggrefe, M. M., Kaden, J. J., & Papavassiliu, T. (2010) · Lung · doi:10.1007/s00408-010-9257-0 · Cited by 30
Reproducibility of 3-dimensional ultrasound readings of volume of carotid atherosclerotic plaque
Ludwig, M., Zieliński, T., Schremmer, D., & Stumpe, K. O. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-42 · Cited by 30
Pyne, M. T., Konnick, E. Q., Phansalkar, A. R., & Hillyard, D. R. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.02329-08 · Cited by 30
The reliability of assessment of vibration sense
Peters, E. W., Bienfait, H. M. E., de Visser, M., & de Haan, R. J. (2003) · Acta Neurologica Scandinavica · doi:10.1034/j.1600-0404.2003.01333.x · Cited by 30
Wodskou, P. M., Hundrup, Y. A., Obel, E. B., & Jørgensen, T. (2010) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016349.2010.500370 · Cited by 33
Metabolic equivalents during the 10-m shuttle walking test for post-myocardial infarction patients
Woolf‐May, K., & Ferrett, D. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.034116 · Cited by 30
Agreement between Spirometers: A Challenge in the Follow-Up of Patients and Populations?
Gerbase, M. W., Dupuis‐Lozeron, E., Schindler, C., Keidel, D., Bridevaux, P., Kriemler, S., Probst-Hensch, N. M., Rochat, T., & Künzli, N. (2013) · Respiration · doi:10.1159/000346649 · Cited by 30
Perception of vertical and horizontal orientation in children with scoliosis
Cheung, J., Sluiter, W. J., Veldhuizen, A. G., Cool, J. C., & van Horn, J. R. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00129-2 · Cited by 30
Trani, J., Babulal, G. M., & Bakhshi, P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143610 · Cited by 36
Reliability and Validity in Neuropsychology
Sherman, E. M. S., Brooks, B. L., Iverson, G. L., Slick, D. J., & Strauss, E. (2010) · Springer eBooks · doi:10.1007/978-0-387-76978-3_30 · Cited by 30
Noninvasive ambulatory measurement system of cardiac activity
Pino, E. J., Chavez, J. A. P., & Aqueveque, P. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320157 · Cited by 30
Order in the absence of an effect: Identifying rate-dependent relationships
Snider, S. E., Quisenberry, A. J., & Bickel, W. K. (2016) · Behavioural Processes · doi:10.1016/j.beproc.2016.03.012 · Cited by 35
Level of agreement between heart rate variability and pulse rate variability in healthy individuals
Bulte, C. S. E., Keet, S. W. M., Boer, C., & Bouwman, R. A. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32834088c4 · Cited by 35
Determinants and Standardization of Mesopic Visual Acuity
Lin, R. J., Ng, J., & Nguyen, A. L. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000584 · Cited by 30
Amara, A., Else, L., Tjia, J. F., Olagunju, A., Puls, R. L., Khoo, S., & Back, D. J. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000127 · Cited by 30
Ghelani, S. J., Harrild, D. M., Gauvreau, K., Geva, T., & Rathod, R. H. (2016) · International journal of cardiac imaging · doi:10.1007/s10554-016-0882-4 · Cited by 30
Paradiso, A., Volpe, S., Iacobacci, A., Marubini, E., Verderio, P., Costa, A., Daidone, M. G., Marchetti, A., Mottolese, M., Amadori, D., et al. (2002) · The International Journal of Biological Markers · doi:10.1177/172460080201700310 · Cited by 31
Bini, R. R., & Hume, P. A. (2016) · Human Movement · doi:10.1515/humo-2016-0005 · Cited by 30
Accuracy of Postural Human-motion Tracking Using Miniature Inertial Sensors
Dinu, D., Fayolas, M., Jacquet, M., Leguy, E., SLAWINSKI, J. S., & Houel, N. (2016) · Procedia Engineering · doi:10.1016/j.proeng.2016.06.266 · Cited by 30
Suever, J. D., Wehner, G. J., Jing, L., Powell, D. K., Hamlet, S. M., Grabau, J. D., Mojsejenko, D., Andres, K. N., Haggerty, C. M., & Fornwalt, B. K. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2646321 · Cited by 30
Joshi, N. R., Ly, E., & Viswanáthan, S. (2017) · Documenta Ophthalmologica · doi:10.1007/s10633-017-9591-0 · Cited by 30
Wandelt, L. K., Kowallick, J. T., Schuster, A., Wachter, R., Stümpfig, T., Unterberg‐Buchwald, C., Steinmetz, M., Ritter, C. O., Lotz, J., & Staab, W. (2017) · International journal of cardiac imaging · doi:10.1007/s10554-017-1160-9 · Cited by 30
Accuracy of on-line self-reported weights and heights by young adults
Nikolaou, C. K., Hankey, C., & Lean, M. E. J. (2017) · European Journal of Public Health · doi:10.1093/eurpub/ckx077 · Cited by 38
Schwarz, S. B., Windisch, W., Magnet, F. S., Schmoor, C., Karagiannidis, C., Callegari, J., Huttmann, S. E., & Storre, J. H. (2017) · Respirology · doi:10.1111/resp.13095 · Cited by 30
Frydrychowicz, A. P., Roldán‐Alzate, A., Winslow, E. R., Consigny, D. W., Campo, C. A., Motosugi, U., Johnson, K. M., Wieben, O. E., & Reeder, S. B. (2017) · European Radiology · doi:10.1007/s00330-017-4862-4 · Cited by 30
Estimating population salt intake in India using spot urine samples
Petersen, K. S., Johnson, C., Mohan, S., Rogers, K. D., Shivashankar, R., Thout, S. R., Gupta, P., He, F. J., MacGregor, G. A., Webster, J. L., et al. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001464 · Cited by 32
Performance Assessment of a Trypanosoma cruzi Chimeric Antigen in Multiplex Liquid Microarray Assays
Santos, F. L. N., Celedón, P. A. F., Zanchin, N. I. T., Leitolis, A., Crestani, S., Foti, L., de Souza, W. V., Gomes, Y. D. M., & Krieger, M. A. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00851-17 · Cited by 30
How well do clinic-based blood pressure measurements agree with the mercury standard?
Kim, J. W., Bosworth, H. B., Voils, C. I., Olsen, M. K., Dudley, T. K., Gribbin, M., Adams, M. B., & Oddone, E. Ž. (2005) · PubMed Central · doi:10.1111/j.1525-1497.2005.0105.x · Cited by 30
Zhao, Y., Durán, R., Bai, W., Sahu, S., Wang, W., Kabus, S., Lin, M., Han, G., & Geschwind, J.-F. (2017) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-017-1829-4 · Cited by 30
Repeatability and Meaningful Change of CPET Parameters in Healthy Subjects
DeCato, T. W., Bradley, S. M., Wilson, E. L., & Hegewald, M. J. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001474 · Cited by 36
Detecting sulfamethoxazole and carbamazepine in groundwater: Is ELISA a reliable screening tool?
Krall, A. L., Elliott, S. M., Erickson, M. L., & Adams, B. A. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.11.065 · Cited by 33
A deep Boltzmann machine-driven level set method for heart motion tracking using cine MRI images
Wu, J., Mazur, T. R., Ruan, S., Lian, C., Daniel, N., Lashmett, H., Ochoa, L., Zoberi, I., Anastasio, M. A., Gach, H. M., et al. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.03.015 · Cited by 32
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.