STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 15,901–16,000 of 47,868
Schurink, G. W. H., Aarts, N. J. M., Malina, M., & van Bockel, J. H. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.108646 · Cited by 31
Modelling impacts of climate change on water resources in the Volta Basin, West Africa
Kasei, R. A. (2010) · bonndoc (University of Bonn) · Cited by 58
Validity of Pharmacoepidemiologic Drug and Diagnosis Data
West, S. L., Ritchey, M. E., & Poole, C. (2012) · Wiley eBooks · doi:10.1002/9781119959946.ch41 · Cited by 37
Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
KOMIYAMA, T., QUARESIMA, V., SHIGEMATSU, H., & FERRARI, M. (2001) · Clinical Science · doi:10.1042/cs1010715 · Cited by 31
Yang, P.-K., Filtjens, B., Ginis, P., Goris, M., Nieuwboer, A., Gilat, M., Slaets, P., & Vanrumste, B. (2023) · doi:10.1101/2023.05.05.23289387 · Cited by 31
QT interval in patients with primary aldosteronism and low-renin essential hypertension
Maule, S., Mulatero, P., Milan, A., Leotta, G., Caserta, M., Bertello, C., Rabbia, F., & Veglio, F. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000251908.93298.a0 · Cited by 30
Lanzarini, L., Larizza, D., Prete, G., Calcaterra, V., Meloni, G., Sammarchi, L., & Klersy, C. (2007) · Journal of Cardiovascular Medicine · doi:10.2459/01.jcm.0000269716.33435.d3 · Cited by 30
Maylor, B. D., Edwardson, C. L., Dempsey, P. C., Patterson, M. R., Plekhanova, T., Yates, T., & Rowlands, A. V. (2022) · Sensors · doi:10.3390/s22249984 · Cited by 30
Wireless Vital Sign Monitoring in Pregnant Women: A Functionality and Acceptability Study
Boatin, A. A., Wylie, B. J., Goldfarb, I., Azevedo, R., Pittel, E., Ng, C., & Haberer, J. E. (2016) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0173 · Cited by 30
The accuracy of a disposable noninvasive core thermometer
Kimberger, O., Saager, L., Egan, C., Sanchez, I. P., Dizili, S., Koch, J., & Kurz, A. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0047-z · Cited by 30
Gough, L. A., Deb, S. K., Sparks, A., & McNaughton, L. R. (2017) · Sports Medicine - Open · doi:10.1186/s40798-017-0101-4 · Cited by 30
Beltran-Alacreu, H., López-de-Uralde-Villanueva, I., Paris-Alemany, A., Angulo-Díaz-Parreño, S., & La Touche, R. (2014) · Journal of Physical Therapy Science · doi:10.1589/jpts.26.915 · Cited by 30
Zapata, M. E., Buffarini, R., Lingiardi, N., & Soares, A. G. (2015) · Revista Española de Nutrición Humana y Dietética · doi:10.14306/renhyd.19.4.177 · Cited by 33
Salvesen, L., Hillesund, E. R., Vik, F. N., Brantsæter, A. L., & Øverby, N. C. (2019) · BMC Nutrition · doi:10.1186/s40795-019-0310-y · Cited by 32
Squara, P., Scheeren, T., Aya, H. D., Bakker, J., Cecconi, M., Einav, S., Malbrain, M. L. N. G., Monnet, X., Reuter, D. A., van der Horst, I. C. C., et al. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00495-x · Cited by 30
Guppy, S. N., Brady, C. J., Kotani, Y., Connolly, S., Comfort, P., Lake, J. P., & Haff, G. G. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1974532 · Cited by 31
Rothenberg, E. M., Strandhagen, E., Samuelsson, J., Ahlner, F., Sterner, T. R., Skoog, I. G., & Lundberg, C. E. (2021) · Nutrients · doi:10.3390/nu13113754 · Cited by 38
Validation of ICD-10-CM Diagnosis Codes for Gestational Age at Birth
Leonard, S. A., Panelli, D. M., Gould, J. B., Gemmill, A., & Main, E. K. (2022) · Epidemiology · doi:10.1097/ede.0000000000001557 · Cited by 31
Wienholtz, N. K. F., Thyssen, J. P., Christensen, C. E., Thomsen, S. F., Karmisholt, K. E., Jemec, G. B. E., Lomholt, H. B., Heidenheim, M., Simonsen, A. B., Sand, C., et al. (2022) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.18721 · Cited by 30
Chen, A., Zhu, J., Lin, Q., & Liu, W. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315883 · Cited by 35
Evaluation of viral infection as an etiology of ME/CFS: a systematic review and meta-analysis
Hwang, J., Lee, J., Oh, H.-M., Lee, E., Lim, E., & Son, C. (2023) · Journal of Translational Medicine · doi:10.1186/s12967-023-04635-0 · Cited by 37
Yang, S.-R., Chien, J., & Lee, C. (2024) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2024.3485534 · Cited by 39
Bagchi, A., Raizada, S., Thapa, R. K., Ștefănică, V., & Ceylan, H. İ. (2024) · Life · doi:10.3390/life14111394 · Cited by 30
Ford, P. R., & Williams, A. M. (2008) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.30.6.709 · Cited by 41
Herrera, L., NAVARRO, I. P., Sánchez-Cano, A. I., Pérez-García, D., Remón, L., Almenara, C., Caramello, C., Cristóbal, J. Á., & Pinilla, I. (2015) · Retina · doi:10.1097/iae.0000000000000636 · Cited by 30
Lagerström, C., & Nordgren, B. (1996) · Upsala Journal of Medical Sciences · doi:10.3109/03009739609178926 · Cited by 31
Tan, H., Hoge, W. S., Hamilton, C. A., Günther, M., & Kraft, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22768 · Cited by 30
Padwal, R. S., Townsend, R. R., Trudeau, L., Hamilton, P. G., & Gelfer, M. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.11.004 · Cited by 33
Elias, L. S. D. T., Guinsburg, R., Peres, C. D. A., Balda, R. D. C. X., & dos Santos, A. M. N. (2008) · Jornal de Pediatria · doi:10.1590/s0021-75572008000100007 · Cited by 30
Wong, M., Staszewsky, L. I., Volpi, A., Latini, R., Barlera, S., & Höglund, C. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.115103 · Cited by 30
Accuracy of oscillometric devices in children and adults
Chioléro, A., Paradis, G., & Lambert, M. A. (2010) · Blood Pressure · doi:10.3109/08037051003606439 · Cited by 34
Mbinze, J. K., Sacré, P., Yémoa, A., Mbay, J. M. T., Habyalimana, V., Tshilombo, N. K., Hubert, P., Marini, R. D., & Ziémons, E. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.02.049 · Cited by 35
Comparison of QIAGEN Automated Nucleic Acid Extraction Methods for CMV Quantitative PCR Testing
Miller, S. A., Seet, H., Khan, Y., Wright, C., & Nadarajah, R. (2010) · American Journal of Clinical Pathology · doi:10.1309/ajcpe5vzl1onzhfj · Cited by 30
Limitations of compensated Jaffe creatinine assays in cirrhotic patients
Kuster, N., Bargnoux, A., Pageaux, G., & Cristol, J. (2011) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2011.11.008 · Cited by 35
Turner, J., Wright, M., Morgan, M., Williams, G. T., & Dolwani, S. (2013) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0b013e32835d1f2d · Cited by 30
Kwee, R. M., Dik, A. K., Sosef, M. N., Berendsen, R. C. M., Sassen, S., Lammering, G., Clarijs, R., Oostenbrug, L. E., Blom, R. L. G. M., & Vliegen, R. F. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092211 · Cited by 30
Desebbe, O., Hénaine, R., Keller, G., Koffel, C., García, H., Rosamel, P., Obadia, J., Bastien, O. H., Lehot, J.-J., Haftek, M., et al. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2013.03.008 · Cited by 31
Akiyoshi, K., Kandabashi, T., Kaji, J., Yamaura, K., Yoshimura, H., Irita, K., & Hoka, S. (2011) · Journal of Anesthesia · doi:10.1007/s00540-010-1087-y · Cited by 30
Chin, E. K., Sedeek, R. W., Li, Y., Beckett, L. A., Redenbo, E., Chandra, K., & Park, S. S. (2011) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/15428877-20111222-02 · Cited by 30
Teo, K. S. L., Carbone, A., Piantadosi, C., Chew, D. P., Hammett, C. J. K., Brown, M., & Worthley, S. G. (2008) · Heart Lung and Circulation · doi:10.1016/j.hlc.2007.11.136 · Cited by 35
Engh, C. A., Zimmerman, R. L., Hopper, R. H., & Engh, C. A. (2012) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-012-2513-2 · Cited by 30
Cesano, A., Rosen, D. B., O'Meara, P., Putta, S., Gayko, U., Spellmeyer, D. C., Cripe, L. D., Sun, Z., Uno, H., Litzow, M. R., et al. (2012) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.21007 · Cited by 30
Schuster, A., Zarinabad, N., Ishida, M., Sinclair, M., van den Wijngaard, J. P. H. M., Morton, G., Hautvast, G. L. T. F., Bigalke, B., van Horssen, P., Smith, N. P., et al. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0082-0 · Cited by 30
Le, D. S. N. T., Brookshire, T., Krakoff, J. A., & Bunt, J. C. (2009) · Metabolism · doi:10.1016/j.metabol.2008.09.029 · Cited by 32
International ring trial to detect anti-Trichinella IgG by ELISA on pig sera
Gómez-Morales, M. Á., Ludovisi, A., Pezzotti, P., Amati, M., Cherchi, S., Lalle, M., Pecoraro, F., & Pozio, E. (2009) · Veterinary Parasitology · doi:10.1016/j.vetpar.2009.09.005 · Cited by 30
Freckmann, G., Schmid, C., Pleus, S., Baumstark, A., Link, M., Stolberg, E., Haug, C., & Sieber, J. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0976 · Cited by 30
Brothers, R. M., Ganio, M. S., Hubing, K. A., Hastings, J. L., & Crandall, C. G. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00784.2010 · Cited by 31
Módis, L., Szalai, E., Kolozsvári, B. L., Németh, G., Vajas, A., & Berta, A. (2011) · Cornea · doi:10.1097/ico.0b013e318204c666 · Cited by 30
Davis, G. K., Roberts, L. M., Mangos, G. J., & Brown, M. A. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000420 · Cited by 29
Hoffmeyer, F., Raulf, M., Harth, V., Bünger, J., & Brüning, T. (2009) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-9-48 · Cited by 31
Ohno, Y., Nishio, M., Koyama, H., Seki, S., Yoshikawa, T., Matsumoto, S., Obara, M., CAUTEREN, M. V., & Sugimura, K. (2014) · Radiology · doi:10.1148/radiol.14132660 · Cited by 30
Schuller, W., Ostelo, R., Janßen, R., & de Vet, H. D. (2014) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-12-53 · Cited by 34
Rao, Z., Wu, X., Liang, B., Wang, M., & Hu, W. (2012) · European journal of medical research · doi:10.1186/2047-783x-17-26 · Cited by 33
Test-retest studies in quantitative sensory testing: a critical review
Werner, M. U., Petersen, M. A., & Bischoff, J. M. (2013) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12150 · Cited by 30
Validation of computed tomography for measuring lung weight
Protti, A., Iapichino, G., Milesi, M., Melis, V., Pugni, P., Comini, B., Cressoni, M., & Gattinoni, L. (2014) · Intensive Care Medicine Experimental · doi:10.1186/s40635-014-0031-0 · Cited by 31
Sihvonen, R., Järvelä, T., Aho, H., & Järvinen, T. L. N. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.00804 · Cited by 35
Pentacam vs SP3000P specular microscopy in measuring corneal thickness
Bernardo, M. D., Borrelli, M., Mariniello, M., Lanza, M., & Rosa, N. (2014) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2014.08.006 · Cited by 30
Knoops, A. J. G., Gerritsen, L., van der Graaf, Y., Mali, W. P. T. M., & Geerlings, M. I. (2012) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2011.12.002 · Cited by 36
Sazonova, N. A., Browning, R. C., & Sazonov, E. E. (2011) · The Open Biomedical Engineering Journal · doi:10.2174/1874120701105010110 · Cited by 33
Leicht, A. S., & Allen, G. D. (2008) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2008000700013 · Cited by 35
Investigation into Low-Level Anti-Rubella Virus IgG Results Reported by Commercial Immunoassays
Dimech, W. J., Arachchi, N., Cai, J., Sahin, T., & Wilson, K. M. (2012) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00603-12 · Cited by 34
Use of regadenoson for measurement of fractional flow reserve
Prasad, A., Zareh, M., Doherty, R., Gopal, A., Vora, H., Somma, K., Mehra, A., Clavijo, L., Matthews, R. V., & Shavelle, D. M. (2013) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25055 · Cited by 30
Does the acceptable noise level (ANL) predict hearing-aid use?
Olsen, S. Ø., & Brännström, K. J. (2013) · International Journal of Audiology · doi:10.3109/14992027.2013.839887 · Cited by 34
Roy, J., Esculier, J.-F., & Maltais, D. B. (2013) · Clinical Rehabilitation · doi:10.1177/0269215513511342 · Cited by 30
Boutoille, D., Marechal, X., Pichenot, M., Chemani, C., Guery, B. P., & Faure, K. (2009) · Experimental Lung Research · doi:10.1080/01902140802632290 · Cited by 30
Ye, C., To, E., Weinreb, R. N., Yu, M., Liu, S., Lam, D. S. C., & Leung, C. K.-S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.03.035 · Cited by 30
Castagnaro, A., Marangio, E., Verduri, A., Chetta, A. A., D’Ippolito, R., Donno, M. D., Olivieri, D., & Cola, G. D. (2007) · Experimental Lung Research · doi:10.1080/01902140701539687 · Cited by 30
Oh, J.-H., Kim, S. H., Chuck, R. S. H., & Park, C. Y. (2013) · Cornea · doi:10.1097/ico.0000000000000034 · Cited by 30
Marley, J. V., Oh, M. S., Hadgraft, N. T., Singleton, S., Isaacs, K., & Atkinson, D. N. (2015) · BMJ Open · doi:10.1136/bmjopen-2014-006277 · Cited by 36
Fischer, M.-O., Diouf, M., de Wilde, R. B. P., Dupont, H., Hanouz, J., & Lorne, E. (2016) · Medicine · doi:10.1097/md.0000000000003530 · Cited by 33
Use of Angle‐Independent M‐Mode Sonography for Assessment of Diaphragm Displacement
Orde, S. R., Boon, A. J., Firth, D. G., Villarraga, H. R., & Sekiguchi, H. (2016) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.15.11100 · Cited by 32
Simultaneous left and right ventricle segmentation using topology preserving level sets
Arrieta, C., Uribe, S. A., Sing‐Long, C., Hurtado, D. E., Andía, M. E., Pablo Irarrázaval, M., & Cristián Tejos, N. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.11.002 · Cited by 30
Examination of the reliability of an inertial sensor-based gait analysis system
Orlowski, K., Eckardt, F., Herold, F., Aye, N., Edelmann‐Nusser, J., & Witte, K. (2017) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2016-0067 · Cited by 31
Szalai, E., Németh, G., Hassan, Z., & Módis, L. (2017) · Cornea · doi:10.1097/ico.0000000000001133 · Cited by 32
THE VALIDITY AND RELIABILITY OF COGNITIVE FAILURES QUESTIONNAIRE IN UNIVERSITY STUDENTS
Ekici, G., Uysal, S. A., & Altuntaş, O. (2016) · Türk fizyoterapi ve rehabilitasyon dergisi · doi:10.21653/tfrd.272979 · Cited by 41
Estrada, L., Torres, A., Sarlabous, L., & Jané, R. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2672800 · Cited by 30
Comparison of non‐invasive tear film stability measurement techniques
Wang, M. T. M., Murphy, P. J., Blades, K. J., & Craig, J. P. (2017) · Clinical and Experimental Optometry · doi:10.1111/cxo.12546 · Cited by 30
Wong, A., Fong, C., Mok, V., Leung, K.-T., & Tong, R. K. (2017) · Journal of Alzheimer s Disease · doi:10.3233/jad-170196 · Cited by 34
Salouti, R., Nowroozzadeh, M. H., Tajbakhsh, Z., Bagheri, M., Ghoreyshi, M., Azizzadeh, M., & Razeghinejad, R. (2017) · Cornea · doi:10.1097/ico.0000000000001300 · Cited by 30
Clinical features of superficial and deep peripapillary microvascular density in healthy myopic eyes
Sung, M. S., Lee, T. H., Heo, H., & Park, S. W. (2017) · PLoS ONE · doi:10.1371/journal.pone.0187160 · Cited by 30
A new automated turbidimetric immunoassay for the measurement of canine C‐reactive protein
Piñeiro, M., Pato, R., Soler, L., Peña, R., García, N., Torrente, C., Saco, Y., Lampreave, F., Bassols, A., & Canalías, F. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12576 · Cited by 30
Ferreira, M. V. N., de Moraes, A. C. F., Toazza-Oliveira, P. V., Forjaz, C. L. M., Aristizábal, J. C., Santaliesra-Pasías, A. M., Lepera, C., Nascimento‐Junior, W. V., Skapino, E., Delgado, C., et al. (2018) · Obesity · doi:10.1002/oby.22116 · Cited by 39
Is the inclinometer a valid measure of thoracic kyphosis? A cross-sectional study
Hunter, D. J., Rivett, D. A., McKiernan, S., Weerasekara, I., & Snodgrass, S. J. (2018) · Brazilian Journal of Physical Therapy · doi:10.1016/j.bjpt.2018.02.005 · Cited by 30
Validation of refraction and anterior segment parameters by a new multi-diagnostic platform (VX120)
Gordon‐Shaag, A., Pinero, D. P., Kahloun, C., Markov, D., Parnes, T., Gantz, L., & Shneor, E. (2018) · Journal of Optometry · doi:10.1016/j.optom.2017.12.003 · Cited by 30
Batcir, S., Sharon, H., Shani, G., Levitsky, N., Gimmon, Y., Kurz, I., Shapiro, A., & Melzer, I. (2018) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2018.03.002 · Cited by 33
Jayaraman, J., ROBERTS, G. J., Wong, H. M., & KING, N. M. (2018) · BMC Medical Imaging · doi:10.1186/s12880-018-0250-z · Cited by 30
Takács, M., Orlovits, Z., Jáger, B., & Kiss, R. M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200245 · Cited by 33
Wells, C. I., McCall, J. L., & Plank, L. D. (2019) · Liver Transplantation · doi:10.1002/lt.25314 · Cited by 33
Development and Validation of the Coeliac Disease Food Attitudes and Behaviours Scale
Satherley, R., Howard, R. A., & Higgs, S. (2018) · Gastroenterology Research and Practice · doi:10.1155/2018/6930269 · Cited by 33
Chan, C., Inskip, J., Kirkham, A., Ansermino, J., Dumont, G., Li, L.-C., Ho, K., Lauscher, H., Ryerson, C., Hoens, A., et al. (2019) · Physiotherapy · doi:10.1016/j.physio.2018.07.015 · Cited by 28
Plaza-Puche, A. B., Salerno, L. C., Versaci, F., Romero, D., & ALIO, J. L. (2018) · European Journal of Ophthalmology · doi:10.1177/1120672118816060 · Cited by 30
Repeatability of measuring knee flexion angles with wearable inertial sensors
Fennema, M. C., Bloomfield, R. A., Lanting, B. A., Birmingham, T. B., & Teeter, M. G. (2018) · The Knee · doi:10.1016/j.knee.2018.11.002 · Cited by 30
Baumbach, P., Neu, C., Derlien, S., Bauer, M. W., Nisser, M., Buder, A., & Coldewey, S. M. (2018) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2018.12.003 · Cited by 32
3D printed microfluidic viscometer based on the co-flowing stream
Hong, H., Song, J. M., & Yeom, E. (2019) · Biomicrofluidics · doi:10.1063/1.5063425 · Cited by 30
The correct measurement of oxygen saturation at high altitude
Tannheimer, M., & Lechner, R. (2019) · Sleep And Breathing · doi:10.1007/s11325-019-01784-9 · Cited by 30
Kularatna, S., Senanayake, S. J., Gunawardena, N. S., & Graves, N. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-024854 · Cited by 31
Tahir, E., Starekova, J., Muellerleile, K., Freiwald, E., von Stritzky, A., Münch, J., Avanesov, M., Weinrich, J. M., Stehning, C., Çavuş, E., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-18-1388 · Cited by 31
A comparison of different methods for assessing leaf area index in four canopy types
Ariza-Carricondo, C., Mauro, F. D., de Beeck, M. O., Roland, M., Gielen, B., Vitale, D., Ceulemans, R., & Papale, D. (2019) · Central European Forestry Journal · doi:10.2478/forj-2019-0011 · Cited by 30
Human-Animal Interactions in Dairy Buffalo Farms
Napolitano, F., Serrapica, F., Braghieri, A., Masucci, F., Sabia, E., & Rosa, G. D. (2019) · Animals · doi:10.3390/ani9050246 · Cited by 37
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.