STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 16,301–16,400 of 47,868
Rothwell, P. M., Gibson, R. J., Villagra, R., Sellar, R., & Warlow, C. P. (1998) · Clinical Radiology · doi:10.1016/s0009-9260(98)80273-0 · Cited by 30
Nuttall, G. A., Oliver, W. C., Beynen, F. M., Dull, J. J., Murray, M. J., & Nichols, W. L. (1993) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(93)90160-m · Cited by 30
Mario, C. D., Gil, R. J., & Serruys, P. W. J. C. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80755-3 · Cited by 30
Resting metabolic rate and body composition in stunted and nonstunted children
Soares‐Wynter, S., & Walker, S. (1996) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.2.137 · Cited by 30
Schuette, S. A., Janghorbani, M., Young, V. R., & Weaver, C. M. (1993) · Journal of the American College of Nutrition · doi:10.1080/07315724.1993.10718315 · Cited by 30
Wieland, W., Wouters, P. F., Aken, H. V., & Flameng, W. J. (2002) · Computers in cardiology · doi:10.1109/cic.1993.378308 · Cited by 30
Foley, D. P., Deckers, J. W., van den Bos, A. A., Heyndrickx, G. R., Laarman, G., Suryapranata, H., Zijlstra, F., & Serruys, P. W. J. C. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90176-d · Cited by 35
Quantification of jiggle in real electromyographic signals
Campos, C., Malanda, A., Gila, L., Segura, V., Lasanta, I., & Artieda, J. (2000) · Muscle & Nerve · doi:10.1002/1097-4598(200007)23:7<1022::aid-mus4>3.0.co;2-3 · Cited by 35
Tinsley, G. M. (2021) · British Journal of Nutrition · doi:10.1017/s0007114520003578 · Cited by 29
Freqüência cardíaca máxima em idosas brasileiras: uma comparação entre valores medidos e previstos
Silva, V. A. P. D., Bottaro, M., Justino, M. A., Ribeiro, M. M., Lima, R. M., & Oliveira, R. J. D. (2007) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2007000300010 · Cited by 29
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29
Virtanen, V. K., Saha, H. H. T., Groundstroem, K. W. E., Salmi, J., & Pasternack, A. I. (2001) · Cardiology · doi:10.1159/000047390 · Cited by 29
Rollheim, J., Tvinnereim, M., Sitek, J., & Osnes, T. (2001) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050100330 · Cited by 29
Mathew, S. T., Po, S. S., & Thadani, U. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2017.10.004 · Cited by 29
Validation of the Fitbit One® for physical activity measurement at an upper torso attachment site
Diaz, K. M., Krupka, D. J., Chang, M. J., Shaffer, J. A., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2016) · BMC Research Notes · doi:10.1186/s13104-016-2020-8 · Cited by 29
Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type
WOODMAN, J. A., CROUTER, S. E., BASSETT, D. R., FITZHUGH, E. C., & BOYER, W. R. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001090 · Cited by 29
A fully-automated analyzer for determining haloacetic acid concentrations in drinking water
Henson, C. M., Emmert, G. L., & Simone, P. S. (2014) · Chemosphere · doi:10.1016/j.chemosphere.2014.09.018 · Cited by 29
Wadehn, F., Carnal, D., & Loeliger, H. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319225 · Cited by 31
BIS/BAS Scale in Primary School Children: Parent-Child Agreement and Longitudinal Stability
Decker, A. D., Verbeken, S., Sioen, I., Michels, N., Vervoort, L., Braet, C., & Henauw, S. D. (2017) · Behaviour Change · doi:10.1017/bec.2017.8 · Cited by 29
Lu, Q., Wei, L., He, W., Zhang, K., Wang, J., Zhang, Y., Rong, X., Zhao, Z., Cai, L., He, X., et al. (2021) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000000790 · Cited by 36
Tanrıverdi, A., Kahraman, B. Ö., Özpelit, E., & Savcı, S. (2023) · Heart Lung and Circulation · doi:10.1016/j.hlc.2023.01.008 · Cited by 34
Bjelkarøy, M. T., Benth, J. Š., Simonsen, T. B., Siddiqui, T. G., Cheng, S., Kristoffersen, E. S., & Lundqvist, C. (2023) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2023.110925 · Cited by 37
Frank, S. M., Jaacks, L. M., Avery, C. L., Adair, L. S., Meyer, K. A., Rose, D. D., & Taillie, L. S. (2024) · PLoS ONE · doi:10.1371/journal.pone.0296069 · Cited by 36
Bourdas, D. I., Travlos, A. K., Souglis, A., Gofas, D. C., Stavropoulos, D., & Bakirtzoglou, P. (2024) · Sports · doi:10.3390/sports12030063 · Cited by 23
Hu, X., Sgherza, T. R., Nothrup, J. B., Fresco, D. M., Naragon‐Gainey, K., & Bylsma, L. M. (2024) · Behavior Research Methods · doi:10.3758/s13428-024-02387-3 · Cited by 36
The Audible Contrast Threshold (ACT) test: A clinical spectro-temporal modulation detection test
Zaar, J., Simonsen, L. B., Sánchez-López, R., & Laugesen, S. (2024) · Hearing Research · doi:10.1016/j.heares.2024.109103 · Cited by 29
Trusting Autonomous Teammates in Human-AI Teams - A Literature Review
Duan, W., Flathmann, C., McNeese, N. J., Scalia, M. J., Zhang, R., Gorman, J. C., Freeman, G., Zhou, S., Hauptman, A. I., & Yin, X. (2025) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3706598.3713527 · Cited by 52
Kruse, B. D., Müller, R., Stockhaus, C., Hartmann, K., Wehner, A., & Konietschke, U. (2014) · Tierärztliche Praxis Ausgabe K Kleintiere / Heimtiere · doi:10.1055/s-0038-1623741 · Cited by 33
Weisinger, H. S., Sinclair, A. J., & Vingrys, A. J. (1998) · Documenta Ophthalmologica · doi:10.1023/a:1001780529354 · Cited by 29
Rohner, F., Kangambèga, M. O., Khan, N. A., Kargougou, R., Garnier, D., Sanou, I., Ouaro, B., Petry, N., Wirth, J. P., & Jooste, P. L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0138530 · Cited by 29
Bell, L., Cox, J., Eade, T., Rinks, M., & Kneebone, A. B. (2013) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12089 · Cited by 29
Shafiee, H., Kanakasabapathy, M. K., Juillard, F., Keser, M., Sadasivam, M., Yüksekkaya, M. E., Hanhauser, E., Henrich, T. J., Kuritzkes, D. R., Kaye, K. M., et al. (2015) · Scientific Reports · doi:10.1038/srep09919 · Cited by 29
Fontana, A., Zambon, A., Cesana, F., Giannattasio, C., & Trocino, G. (2012) · Echocardiography · doi:10.1111/j.1540-8175.2011.01618.x · Cited by 29
Wang, N., Wang, B., Zhai, G., Lei, K., Wang, L., & Congdon, N. G. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.11.051 · Cited by 29
Aguirre, C. A., Salazar, G., de Romaña, D. L., Kain, J., Corvalán, C., & Uauy, R. D. (2014) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2014.144 · Cited by 32
John, M., Angst, F., Awiszus, F., King, G. J. W., MacDermid, J. C., & Simmen, B. R. (2010) · Journal of Hand Therapy · doi:10.1016/j.jht.2010.03.001 · Cited by 31
An Uncalibrated Pulse Contour Method to Measure Cardiac Output During Aortic Counterpulsation
Scolletta, S., Franchi, F., Taccone, F. S., Donadello, K., Biagioli, B., & Vincent, J. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318230b2de · Cited by 29
Kinematic analysis of three water polo front crawl styles
de Jesus, K., Figueiredo, P., de Jesus, K., Pereira, F., Vilas‐Boas, J. P., Machado, L. J., & Fernandes, R. J. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.669043 · Cited by 29
Repeatability of Measurements Obtained with a Ray Tracing Aberrometer
Pinero, D. P., Sánchez-Pérez, P. J., & ALIO, J. L. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182223788 · Cited by 29
Batista, M. B., Cyrino, E. S., de Arruda, M., Dourado, A. C., Coelho-e-Silva, M. J., Ohara, D., Romanzini, M., & Ronque, Ê. R. V. (2013) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3182815724 · Cited by 40
Quantifying tumour-infiltrating lymphocyte subsets: A practical immuno-histochemical method
Loughlin, P., Cooke, T. G., George, W. D., Gray, A. J., Stott, D. I., & Going, J. J. (2007) · Journal of Immunological Methods · doi:10.1016/j.jim.2007.01.012 · Cited by 29
Ang, M., Chong, W. G. W., Huang, H., Tay, W. T., Wong, T. Y., He, M., Aung, T., & Mehta, J. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0065559 · Cited by 29
Ground reaction forces of Olympic and World Championship race walkers
Hanley, B., & Bissas, A. (2014) · European Journal of Sport Science · doi:10.1080/17461391.2014.984769 · Cited by 29
Li, S., Wong, S. J., & Cheung, Y. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.03.020 · Cited by 29
Sato, S., Demura, S., Kitabayashi, T., & Noguchi, T. (2007) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.2114/jpa2.26.533 · Cited by 29
Klonizakis, M., Manning, G., & Donnelly, R. (2011) · Skin Pharmacology and Physiology · doi:10.1159/000322853 · Cited by 29
Assessing motivational interviewing integrity for group interventions with adolescents.
D’Amico, E. J., Osilla, K. C., Miles, J. N. V., Ewing, B. A., Sullivan, K., Katz, K., & Hunter, S. B. (2012) · Psychology of Addictive Behaviors · doi:10.1037/a0027987 · Cited by 35
Moon, J. R., Hull, H. R., Tobkin, S. E., Teramoto, M., Karabulut, M., Roberts, M. D., Ryan, E. D., Kim, S. J., Dalbo, V. J., Walter, A. A., et al. (2007) · Journal of the International Society of Sports Nutrition · doi:10.1186/1550-2783-4-16 · Cited by 38
Shape and individual variability of the blur adaptation curve
Vera‐Díaz, F. A., Woods, R. L., & Peli, E. (2010) · Vision Research · doi:10.1016/j.visres.2010.04.013 · Cited by 30
Acierno, M. J., Domingues, M., Ramos, S. J., Shelby, A. M., & da Cunha, A. F. (2015) · American Journal of Veterinary Research · doi:10.2460/ajvr.76.3.266 · Cited by 31
Comparison of Body Composition Assessment Methods in Pediatric Intestinal Failure
Mehta, N. M., Raphael, B. P., Guteirrez, I. M., Quinn, N. L., Mitchell, P. D., Litman, H. J., Jaksic, T., & Duggan, C. (2014) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0000000000000364 · Cited by 29
Koekkoek, P. S., Rutten, G. E. H. M., van den Berg, E., van Sonsbeek, S., Gorter, K. J., Kappelle, L. J., & Biessels, G. J. (2013) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2013.02.028 · Cited by 30
Shuaibi, A. M., Sevenhuysen, G. P., & House, J. D. (2008) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2008.09.002 · Cited by 29
Comparison of ActiGraph activity monitors in persons with multiple sclerosis and controls
Sandroff, B. M., & Motl, R. W. (2013) · Disability and Rehabilitation · doi:10.3109/09638288.2012.707745 · Cited by 29
Testing the Pediatric Cardiac Quality of Life Inventory in the United Kingdom
Wray, J., Franklin, R. C. G., Brown, K., Cassedy, A. E., & Marino, B. S. (2012) · Acta Paediatrica · doi:10.1111/apa.12074 · Cited by 32
CT-Based Attenuation Correction in I-123-Ioflupane SPECT
Lange, C., Seese, A., Schwarzenböck, S. M., Steinhoff, K. G., Umland-Seidler, B., Krause, B. J., Brenner, W., Sabri, O., Kurth, J., Hesse, S., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0108328 · Cited by 30
Christian, M. S., Evans, C., Nykjaer, C., Hancock, N., & Cade, J. E. (2014) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2014.160 · Cited by 37
Schneider, W., Csepan, R., Kasparek, M., Pinggera, O., & Knahr, K. (2002) · Acta Orthopaedica Scandinavica · doi:10.1080/000164702321039651 · Cited by 29
Romagnoli, S., Ricci, Z., Romano, S. M., Dimizio, F., Bonicolini, E., Quattrone, D., & Gaudio, R. D. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2013.04.017 · Cited by 33
A Novel System Identification Technique for Improved Wearable Hemodynamics Assessment
Wiens, A. D., & Inan, O. T. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2387354 · Cited by 35
PULSE WAVE VARIABILITY WITHIN TWO SHORT-TERM MEASUREMENTS
Korpas, D., & Hálek, J. (2006) · Biomedical Papers · doi:10.5507/bp.2006.052 · Cited by 29
Repeating Tests: Different Roles in Research Studies and Clinical Medicine
Monach, P. A. (2012) · Biomarkers in Medicine · doi:10.2217/bmm.12.57 · Cited by 36
Modified Test Administration Using Assistive Technology
Warschausky, S. A., Tubbergen, M. V., Asbell, S., Kaufman, J. N., Ayyangar, R. N., & Donders, J. (2011) · Assessment · doi:10.1177/1073191111402458 · Cited by 29
Nieto, J. E., Dechant, J. E., le Jeune, S. S., & Snyder, J. R. (2014) · Veterinary Surgery · doi:10.1111/j.1532-950x.2014.12231.x · Cited by 37
A preliminary study on application of portable monitoring for diagnosis of obstructive sleep apnea
Yin, M., Miyazaki, S., Itasaka, Y., Shibata, Y., Abe, T., Miyoshi, A., Ishikawa, K., & Togawa, K. (2005) · Auris Nasus Larynx · doi:10.1016/j.anl.2004.11.004 · Cited by 29
Terslev, L., Ellegaard, K., Christensen, R., Szkudlarek, M., Schmidt, W., Jensen, P. S., Bliddal, H., & Torp‐Pedersen, S. (2012) · Rheumatology · doi:10.1093/rheumatology/kes124 · Cited by 29
Crossed cerebellar diaschisis after stroke: Can perfusion-weighted MRI show functional inactivation?
Madai, V. I., Altaner, A., Stengl, K. L., Zaro‐Weber, O., Heiss, W., von Samson‐Himmelstjerna, F. C., & Sobesky, J. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.15 · Cited by 32
Black, L. J., Burrows, S., Jacoby, P., Oddy, W. H., Beilin, L. J., Ping‐Delfos, W. C. S., Marshall, C. E., Holt, P. G., Hart, P. H., & Mori, T. A. (2014) · British Journal Of Nutrition · doi:10.1017/s000711451400186x · Cited by 33
Lemoine, S., Papillard, M., Belloi, A., Rognant, N., Fouque, D. P., Laville, M., Rouvière, O., & Juillard, L. (2011) · Radiology · doi:10.1148/radiol.11101317 · Cited by 29
Kobayashi, Y., Ariyama, M., Kobayashi, Y., Giraldeau, G., Fleischmann, D., Koželj, M., Vrtovec, B., Ashley, E. A., Kuznetsova, T., Schnittger, I., et al. (2015) · International journal of cardiac imaging · doi:10.1007/s10554-015-0804-x · Cited by 30
Early Ventricular Dysfunction After Anthracycline Chemotherapy in Children
Agha, H. M., Shalaby, L., Attia, W., Abdelmohsen, G., Aziz, O. A., & Rahman, M. Y. A. (2015) · Pediatric Cardiology · doi:10.1007/s00246-015-1311-5 · Cited by 29
Buch‐Andersen, T., Pérez-Cueto, F. J. A., & Toft, U. (2015) · Public Health Nutrition · doi:10.1017/s136898001500275x · Cited by 35
The Caledonian face test: A new test of face discrimination
Logan, A. J., Wilkinson, F. E., Wilson, H. R., Gordon, G. E., & Löffler, G. (2016) · Vision Research · doi:10.1016/j.visres.2015.11.003 · Cited by 31
Conway, D. H., Hussain, O. A., & Gall, I. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e3283603250 · Cited by 29
Estimating Energy Expenditure from Raw Accelerometry in Three Types of Locomotion
Brandes, M., van Hees, V. T., HANNÖVER, V., & Brage, S. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318260402b · Cited by 40
Axial Eye Length Evaluation Before and After Hyperopic Photorefractive Keratectomy
Rosa, N., Bernardo, M. D., & Lanza, M. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20121227-02 · Cited by 29
Cover, K. S., van Schijndel, R. A., Versteeg, A., Leung, K. K., Mulder, E. R., de Jong, R. A., Visser, P. J., Redolfi, A., Revillard, J., Grenier, B., et al. (2016) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2016.04.006 · Cited by 32
Arriola‐Villalobos, P., Almendral-Gómez, J., Garzón, N., Ruiz‐Medrano, J., Fernández, C., Martínez-de-la-Casa, J. M., & Díaz‐Valle, D. (2016) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2016.09.003 · Cited by 29
Validity and Reliability of the Upper Extremity Work Demands Scale
Jacobs, N. W., Berduszek, R. J., Dijkstra, P. U., & van der Sluis, C. K. (2016) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-016-9683-9 · Cited by 29
Validity of BMI-Based Body Fat Equations in Men and Women: A 4-Compartment Model Comparison
Nickerson, B. S., Esco, M. R., Bishop, P. A., Fedewa, M. V., Snarr, R. L., Kliszczewicz, B. M., & Park, K.-S. (2016) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001774 · Cited by 35
Zhu, J., Zhang, J., Gao, J., Li, J.-N., Yang, D., Chen, M., Zhou, C., & Yang, Z. (2017) · Medicine · doi:10.1097/md.0000000000005910 · Cited by 30
Motamedi‐Fakhr, S., Iles, R. W., Barney, A. M., de Boer, W. I. J., Conlon, J., Khalid, A., & Wilson, R. C. (2017) · Physiological Reports · doi:10.14814/phy2.13124 · Cited by 30
Astrophysical properties of star clusters in the Magellanic Clouds homogeneously estimated by ASteCA
Perren, G. I., Piatti, A. E., & Vázquez, R. A. (2017) · Astronomy and Astrophysics · doi:10.1051/0004-6361/201629520 · Cited by 32
Anwar, S., Negishi, K., Borowszki, A., Gladding, P. A., Popović, Z., Erenberg, F. G., & Thomas, J. D. (2017) · JRSM Cardiovascular Disease · doi:10.1177/2048004017712862 · Cited by 29
High‐resolution anorectal manometry: A comparison of solid‐state and water‐perfused catheters
Rasijeff, A. M. P., Withers, M. M., Burke, J., Jackson, W., & Scott, S. M. (2017) · Neurogastroenterology & Motility · doi:10.1111/nmo.13124 · Cited by 29
Zhao, Y., Li, S.-P., Liu, L., Zhang, J., & Chen, G. (2017) · Medicine · doi:10.1097/md.0000000000007840 · Cited by 33
Capillary PO2 does not adequately reflect arterial PO2 in hypoxemic COPD patients
Magnet, F. S., Daniel, S. M., Callegari, J., Schwarz, S. B., Schmoor, C., Windisch, W., & Storre, J. H. (2017) · International Journal of COPD · doi:10.2147/copd.s140843 · Cited by 30
Garnotel, M., Bastian, T., Ugalde, H. M. R., Maire, A., Dugas, J., Zahariev, A., Doron, M., Jallon, P., Charpentier, G., Franc, S., et al. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00556.2017 · Cited by 33
Korshin, A., Grønlykke, L., Nilsson, J. C., Møller‐Sørensen, H., Ihlemann, N., Kjøller, M., Damgaard, S., Lehnert, P., Hassager, C., Kjærgaard, J., et al. (2018) · International journal of cardiac imaging · doi:10.1007/s10554-018-1306-4 · Cited by 29
Clark, M. R., Hurley, R. W., & Adams, M. C. B. (2017) · Pain Medicine · doi:10.1093/pm/pnx332 · Cited by 35
Feißt, A., Kuetting, D. L. R., Dabir, D., Luetkens, J. A., Homsi, R., Schild, H. H., & Thomas, D. (2018) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2018.02.007 · Cited by 29
Düppe, K., Becker, M., & Schönmeyr, B. H. (2018) · Journal of Craniofacial Surgery · doi:10.1097/scs.0000000000004580 · Cited by 29
Godano, E., Morana, G., Iorgi, N. D., Pistorio, A., Allegri, A. E. M., Napoli, F., Gastaldi, R., Calcagno, A., Patti, G., Gallizia, A., et al. (2018) · European Journal of Endocrinology · doi:10.1530/eje-18-0094 · Cited by 31
Kyranis, S. J., Latona, J., Platts, D. G., Kelly, N. F. A., Savage, M. L., Brown, M. R., Hamilton-Craig, C. R., Scalia, G. M., & Burstow, D. J. (2018) · Echocardiography · doi:10.1111/echo.13893 · Cited by 29
Kalafat, E., Mir, I., Perry, H., Thilaganathan, B., & Khalil, A. A. (2018) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.19094 · Cited by 31
Griffin, B. R., Butler-Dawson, J., Dally, M. J., Krisher, L. K., Cruz, Á., Weitzenkamp, D. A., Sorensen, C. J., Tenney, L., Johnson, R. J., & Newman, L. S. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204614 · Cited by 29
Mercado, P., Maizel, J., Beyls, C., Kontar, L., Orde, S. R., Huang, S., McLean, A. S., Tribouilloy, C. M., & Slama, M. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003422 · Cited by 29
Reiter, G. S., Told, R., Baratsits, M., Hecht, A., Schlanitz, F. G., Sacu, S., & Schmidt-Erfurth, U. M. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13987 · Cited by 29
Zhou, R., Yang, Y., Mathew, R. C., Mugler, J. P., Weller, D. S., Kramer, C. M., Ahmed, A. H., Jacob, M., & Salerno, M. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27763 · Cited by 29
Attuluri, A. K., Serkad, C. P. V., Gunda, A., Ramkumar, C., Basavaraj, C., Buturović, L. J., Madhav, L., Naidu, N., Krishnamurthy, N., Prathima, R., et al. (2019) · BMC Cancer · doi:10.1186/s12885-019-5443-5 · Cited by 31
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.