STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 44,301–44,400 of 47,868
A case of multiple gastrointestinal endocrine and non-endocrine neoplasms
Kasajima, A., & Sasano, H. (2016) · Pathology · doi:10.1016/j.pathol.2015.12.354
Nomura, K., Yamano, S., Minami, S., Fujimoto, S., Yamamoto, Y., Fukui, R., Takaoka, M., & Dohi, K. (1999) · Neurosonology · doi:10.2301/neurosonology.12.1
Azambuja, A., de Freitas, G., Menna, C., Silveira, B., Franceschi, M. G., & Carvalho, P. R. A. (2013) · Lume (Universidade Federal do Rio Grande do Sul)
CARDIOLOGÍA DEL ADULTO - TRABAJOS LIBRES
Ballesteros, L. E., Ramírez, L. M., & Forero, P. L. (2016)
A STUDY OF THE UTILITY OF BLOOD THEOPHYLLINE MEASUREMENT KIT ED009 USING BIOTRACK 516
Tsubaki, T., Sugihara, Y., Iwasaki, A., Koshibu, T., Matsuda, S., Sakaguchi, N., Akasawa, A., Obata, T., & Iíkura, Y. (1994) · Nihon Shoni Arerugi Gakkaishi The Japanese Journal of Pediatric Allergy and Clinical Immunology · doi:10.3388/jspaci.8.27
Different cardiac loading conditions and haemodynamic monitoring in animal models
Kobr, J., Třeška, V., Moláček, J., Kuntscher, V., Liška, V., & Koppl, J. (2012) · Bratislavské lekárske listy/Bratislava medical journal · doi:10.4149/bll_2012_032
Lee, L. K., Shahar, S., Aini, N., Yusoff, M. F., & Chin, A. (2013)
Clinical Comparison of Pulse Oxymeter and SleepStrip in Screening Sleep Apnea Syndrome
Mashima, K., Kanemura, T., Ishikawa, K., & Miyazaki, S. (2010) · Practica oto-rhino-laryngologica Suppl · doi:10.5631/jibirinsuppl.129.41
Functional Independence Measure Prediction
ZAFONTE, R. D., Millis, S. R., Mann, N., Black, K. L., Watanabe, T. K., DeSantis, N. M., & Pelshaw, C. B. (2000) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200005000-00010
Stout, M., Pearce, K., & Williams, S. G. (2015) · Cardiovascular Endocrinology · doi:10.1097/xce.0000000000000047
Noninvasive Assessment of Photoreceptor Structure and Function in the Human Retina
Cooper, R. F. (2015) · e-Publications@Marquette (Marquette University) · Cited by 1
MASTOCITOSE NA INFÂNCIA: ESTUDO ANÁTOMO- PATOLÓGICO E IMUNO-HISTOQUÍMICO
Pós-Graduação, P. D. (2002)
Rating the Ratings: The AIR Scoring System for Blogs and Podcasts
Trueger, N. S., & Schriger, D. L. (2016) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2016.07.034
Lehrstuhl, A. D., Orthopädie, F., & Medizin, F. (2015)
München, K. D. L.-M.-U., & Reincke, M. (2010)
3D Imaging for Planning of Minimally Invasive Surgical Procedures
Numburi, U. D. (2011) · EngagedScholarship @ Cleveland State University (Cleveland State University)
Longitudinal Association Between Body Mass Index and Health-Related Quality of Life.
Müller-Nordhorn, J., Muckelbauer, R., Englert, H. S., Grittner, U., Berger, H., Prugger, C., Wegscheider, K., & Willich, S. N. (2015) · International Journal of Epidemiology · doi:10.1093/ije/dyv096.343
Shamlan, G. H. (2016) · University of Surrey Open Research repository
Evaluación de la validez y precisión del hemograma automatizado (CELL-DYN 1600)
Martínez, O., Inés, M., & de Goenaga, L. (1997)
Gaurilčikas, A., Vaitkienė, D., Kajėnas, S., Čižauskas, A., Švedas, E., Nadišauskienė, R. J., & Testa, A. C. (2008)
Reducing the Radiation Dose During Excretory Urography
Heßelmann, V., Schulte, O., Kamm, K.-F., Braun, W., Haupt, G., Krug, B., & Lackner, K. J. (2003)
Moananui, R. T., Kieser, J. A., Herbison, P., & Liversidge, H. M. (2008)
Metabolic monitoring in patients undergoing cardiac surgery using intravascular microdialysis
Schierenbeck, F. (2016) · Figshare
Assessment of Agreements in Linear and Generalized Linear Mixed Models
于, Y. 越. Y. (2012) · Figshare
Aus der Klinik für Anästhesiologie und Operative Intensivmedizin
Steinfath, M., & Weiler, N. (2011)
Zhao, P., Shi, J., Qiu, L., Li, J., Jin, M., Xu, F., Gong, W., & Wu, Y. (2016) · Bulletin of Environmental Contamination and Toxicology · doi:10.1007/s00128-016-1807-6
ARTIGOS ORIGINAIS / ORIGINAL ARTICLES
Nalepa, K. C., & Ferreira, S. M. R. (2013)
Images using Revoting Hough Transform (RVHT)
Zhou, Y., & Zheng, Y. (2007)
Lara, R. M. M. (2015) · Digital Repository (Polytechnic University of Cartagena) · doi:10.31428/10317/5288 · Cited by 1
Biomechanikai módszerek a csípőízületi kopás hatásának vizsgálatára
Akadémia, M. T. (2012)
Testing macular letter recognition ‐ reliability and influence of refraction errors
Eisenbarth, W., Richert, J., & MacKeben, M. (2016) · Clinical and Experimental Optometry · doi:10.1111/cxo.12360
Braga, L. M. (2016) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.5.2016.tde-03022016-092625
Mudie, K. L., Gupta, A., & Clothier, P. J. (2016) · ISBS - Conference Proceedings Archive
Infant feeding practices among Norwegian-Somali and Norwegian-Iraqi infants
Grewal, N. K. (2016) · NORA - Norwegian Open Research Archives
DEVELOPMENT OF A NOVEL DEVICE FOR MEASUREMENT OF PEDAL FORCE IN CYCLING
Fuglsang, T., & Kersting, U. G. (2016) · ISBS - Conference Proceedings Archive
Corrêa, S., Dos, D. L., Rodrigo, D., Boufleur, J., & da Silveira, M. (2015)
Reyhan, M. L. (2012) · eScholarship (California Digital Library)
Handling missing items in the Exacerbations of Chronic Pulmonary Disease Tool
Hitchings, A. W., Baker, E. H., & Jones, P. (2016) · European Respiratory Journal · doi:10.1183/13993003.00269-2016
measure CD4+ lymphocyte counts in HIV-1-infected patients
Baker, A. B., Behr, E. R., Bowker, T. J., Burton, J. D., Cary, N. R. B., Casey, A., Chambers, D., Davies, M. J., Greenberg, M. R., McKenna, W. J., et al. (2003)
Doetsch, A. M., Faber, J., Lynnerup, N., & Bliddal, H. (2004)
Nunes, L. N., Camey, S. A., Santos, L., Guimarães, P., Mancuso, A. C. B., & Hirakata, V. N. (2013)
Esteves, A. R. O. (2012) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
The Quality Assurance and Control Plan
den Broeck, J. V., & Brestoff, J. R. (2013) · Springer eBooks · doi:10.1007/978-94-007-5989-3_11
Clinical Assays for Biological Macromolecules
Zhang, J., & Kubiak, R. J. (2016) · Statistics for biology and health · doi:10.1007/978-3-319-23558-5_11
Kannan, S., & Gowri, S. (2015) · Journal of Scientometric Research · doi:10.4103/2320-0057.167245
Gaudio, C., Tanzilli, G., Vittore, A., Arca, M., Barillà, F., Michele, S. D., Minardi, G., Fedele, F., Lombardi, M., & Donato, L. (2004) · PubMed
Morgan, W. (1992) · Thorax · doi:10.1136/thx.47.10.808
Investigation of Arterial Geometry as a Local Risk Factor for Carotid Atherosclerosis
Bijari, P. B. (2013) · TSpace (University of Toronto)
Raab, S., Thein, E., Harris, A. G., Habler, O. P., Kleen, M. S., Pape, A., Meisner, F. G., & Meßmer, K. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1998.43.s1.538
Riffe, J. J. (2016) · STARS (University of Central Florida)
Zakrison, T. L., & McCREDIE, V. A. (2012) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3182509103
Multicompartment model comparison of body fat assessment in Thai adolescents.
Srichan, W., Kijboonchoo, K., Yamborisut, U., Thasanasuwan, W., & Deurenberg, P. (2014) · PubMed
Lunde, K. (2008) · NVA (Nasjonalt vitenarkiv)
Brouwer, S. (2004) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-9666-5_7
The reliability and validity of magnetic resonance imaging in patients with hand osteoarthritis
Haugen, I. K. (2012) · NORA - Norwegian Open Research Archives
Nogawa, M., 山越, 健., 松村, 健., 田中, 志., 小川, 充., 本井, 幸., & 山越, 憲. (2011) · Institutional Repositories DataBase (IRDB) · doi:10.11239/jsmbe.49.968 · Cited by 1
Kartlegging av gangfunksjon : En validitets- og reliabilitetsstudie av Salford Gait Tool
Larsen, K. L. (2008) · NORA - Norwegian Open Research Archives
Pena, J. L. B., Silva, M. G., Cristina, S., Faria, C., Mariano, J. R., ��������������������������������������������������������, A., Salemi, V. M. C., Mady, C., & Sutherland, G. R. (2012)
A Common Region of Interest (ROI) Improves the Comparability among DXA Devices
Prevrhal, S., Lü, Y., Genant, H. K., Toschke, J. O., & Shepherd, J. (2005)
Iden, T., Horn, E.-P., Bein, B., Böhm, R., & Höcker, J. (2015) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000364
An Integrative Review Focusing on Accuracy and Reliability of Clinical Thermometers
Black, J. B. (2016) · ScholarWorks (Walden University)
Calvo, V. E., Gutiérrez, I. Z., Bernabe, J., Llorente, L. S. F., & Arenas, J. M. B. (2009) · PubMed
Su, Z. (2010) · CU Scholar (University of Colorado Boulder)
Accuracy of Quantitative Coronary Angiography for Different Directions of the Coronary Artery
Kageyama, T., Satou, T., Imazeki, M., SATOU, H., 植木, 茂., Wakamatsu, O., Amauchi, H., & Nakazawa, Y. (2005) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.kj00003326616
Horton, L., Emery, P., & Marshall, P. (2016) · Ultrasound · doi:10.1177/1742271x16652439
Cerebral Extraction Monitoring in Brain Injury
Stocchetti, N., Rossi, S., & Rotelli, S. (1998) · Yearbook of intensive care and emergency medicine · doi:10.1007/978-3-642-72038-3_61
Moe, R. H. (2013) · NVA (Nasjonalt vitenarkiv)
Hanumunthadu, D., Ilginis, T., Balaggan, K. S., & Patel, P. J. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.04.027
Robust statistical approaches to assess the degree of agreement of clinical data
Grilo, L. M., & Grilo, H. L. (2016) · AIP conference proceedings · doi:10.1063/1.4952235
Neudecker, J., Schwenk, W., & Müller, J. (2000)
Mariacher, S., Hipp, S., Wirthky, R., Blumenstock, G., Bartz‐Schmidt, K. U., Ziemssen, F., Schiefer, U., Voykov, B., & Januschowski, K. (2016) · Journal of Ophthalmology · doi:10.1155/2016/4764857
Computer-aided Analysis of Dietary Nutrient and Fibre Intakes in Gastroenterology
McIntyre, A. S., Ibbotson, M., Duthie, J., Burnham, S. P., O’Brien, J., Day, S., & Burnham, W. R. (1988) · Springer eBooks · doi:10.1007/978-1-4471-3259-2_24
Reliability of Gait Parameters Depending on HJC Estimation Method
Krepelka, M., Toth-Taşcău, M., & Stoia, D. I. (2014) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-07653-9_65
McKenzie, N. E., & Erickson, R. S. (1996) · Journal of PeriAnesthesia Nursing · doi:10.1016/s1089-9472(96)90084-2
Helduen altuera iragarpena: belaunerainoko altuera neurriak
Arroyo‐Izaga, M., de la Pera, C. M., Alday, L. A., Bediaga, N. G., & Pablo, A. M. R. (2010) · Communities in ADDI (Universidad del Pais Vasco)
Evaluation of A Protective Sheath for Disposable Pulse Oximetry Probes
Gerber, D. R., Santarelli, R. J., Scott, W. E., Kern, M. E., & DuBois, J. M. (1996) · Respiratory Care · doi:10.1177/002013249604100305
Süperior Vena Kaval ve Femoroiliyak Basinçlar Üzerine Değişen PEEP Seviyelerinin Etkisi
Sungur, M., Ok, E., Güven, M., Ekici, E., & Tokgöz, B. (2003)
(2008) · The Internet Journal of Anesthesiology · doi:10.5580/210c
Helle-Valle, T. M. (2013) · NORA - Norwegian Open Research Archives
Validierung des „OPS imaging“ Verfahrens an der Rattenleber
Langer, S. W., Harris, A. G., Biberthaler, P., Krombach, F., & Meßmer, K. (2000) · Langenbecks Archiv für Chirurgie. Supplement · doi:10.1007/978-3-642-57295-1_65
Arvind, H., George, R. J., Raju, P., Ve, R. S., Mani, B., Kannan, P., & Vijaya, L. (2007) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2007.01642.x
Coertjens, P. C., Knorst, M. M., Dumke, A., Pasqualoto, A. S., Riboldi, J., Saldanha, S., & Barreto, M. (2013)
Horn, P., Stefler, J., & Kovács, A. (2012)
Rebocho, L. M., Zymbal, V., & Sardinha, L. B. (2014)
Untersuchung zum Langzeit-Verlauf von Schilddrsenknoten
Reincke, M. (2013)
Imanaka, H., HESS, D. R., Al-Himyary, A., Bigatello, L. M., Ritz, R., Kacmarek, R. M., & Hurford, W. E. (1997) · The Journal of Clinical Monitoring · doi:10.1023/a:1007305902518
Der Munich-Neurotrauma-Score (MNTS)
Frank, A. M., Harth, A., & Trappe, A. E. (2004) · Intensivmedizin und Notfallmedizin · doi:10.1007/s00390-004-0437-0
do Nascimento, R. L., Navarro, F., Sevílio, M., Souza, R. A. C., & Moreira, S. R. (2014) · Motricidade · doi:10.6063/motricidade.10(3).2708
Repeatability of Cerebral Perfusion Using Dynamic Susceptibility Contrast MRI in
Jafari‐Khouzani, K., Emblem, K. E., Kalpathy–Cramer, J., Bjørnerud, A., Vangel, M. G., Gerstner, E. R., Schmainda, K. M., Wu, O., Wen, P. Y., Batchelor, T. T., et al. (2015)
Tetreault, L. A. (2015) · TSpace (University of Toronto)
Herndon, L. W. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.4.579
Influence of age, exercise and atrial fibrillation on the cerebrovascular function
Bráz, I. D. (2016) · University of Birmingham Institutional Research Archive (University of Birmingham)
Defining the T status in breast cancer: Where do we stand?
Rajaraman, R., Shanmugam, S., Gandhi, A., & Shunmugam, D. (2016) · Clinical Cancer Investigation Journal · doi:10.4103/2278-0513.183495
Study of lung asbestos content in a Spanish population
García, V., & Isabel, M. (2014) · TDX (Tesis Doctorals en Xarxa)
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.