Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hip joint loading during walking and running, measured in two patients
Bergmann, G., Graichen, F., & Rohlmann, A. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90058-m · Cited by 1,276 · cited 1×
“The value 1 kN is the average value of a typical load waveform [26].”
BackgroundEffect of femoral head size on wear of the polyethylene acetabular component.
Livermore, J., Ilstrup, D., & Morrey, B. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00008 · Cited by 1,024
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissues
Campbell, P., Ma, S., Yeom, B., McKellop, H., Schmalzried, T. P., & Amstutz, H. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290118 · Cited by 352 · cited 1×
“Adapting a previously published method [9], polyethylene wear particles produced between 2 and 3 million cycles were isolated from the used serum.”
MethodRelationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty
Sochart, D. H. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199906000-00018 · Cited by 272 · cited 1×
“The prevalence of osteolysis and loosening increases with increasing wear [1].”
BackgroundOrientation softening in the deformation and wear of ultra-high molecular weight polyethylene
Wang, A., Sun, D. C., Yau, S.-S., Edwards, B., Sokol, M., Essner, A., Polineni, V. K., Stark, C., & Dumbleton, J. H. (1997) · Wear · doi:10.1016/s0043-1648(96)07362-0 · Cited by 231 · cited 1×
“Second, since the force locus in the BRM simulator is circular (because the abduction}adduction has an exaggerated excursion, equal to that of the #exion}extension), instead of an elongated loop as suggested by a biomechanical analysis [25], and since the wear simulation has nevertheless proved to be realistic [2,3,6]…”
BackgroundMeasurement of Polyethylene Wear in Metal-Backed Acetabular Cups: I. Three-Dimensional Technique
Devane, P. A., Bourne, R. B., Rorabeck, C. H., Hardie, R. M., & Home, J. G. (1995) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199510000-00033 · Cited by 185
Assessment of Polyethylene Wear in Total Hip Replacement
Devane, P., & Horne, J. G. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199912000-00007 · Cited by 177 · cited 1×
“On the other hand, another clinical study showed no di!erence between metal and ceramic head groups [13].”
BackgroundComparison and quantitation of wear debris of failed total hip and total knee arthroplasty
Hirakawa, K., Bauer, T. W., Stulberg, B. N., & Wilde, A. H. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199606)31:2<257::aid-jbm13>3.0.co;2-i · Cited by 135
Semlitsch, M., & Willert, H. G. (1997) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411971534700 · Cited by 124 · cited 3×
“In one clinical study, the average wear rate of polyethylene cups against alumina heads was 50 per cent lower than that against CoCr heads [7].”
BackgroundResultInfluential
Cited by
A review of modified DLC coatings for biological applications
Hauert, R. (2003) · Diamond and Related Materials · doi:10.1016/s0925-9635(03)00081-5 · Cited by 681
Biomedical applications of diamond-like carbon (DLC) coatings: A review
Dearnaley, G., & Arps, J. H. (2005) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2005.07.077 · Cited by 502
Biomedical applications of diamond‐like carbon coatings: A review
Roy, R. K., & Lee, K. (2007) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30768 · Cited by 496
Metadata
- Authors
- Saikko, V., Ahlroos, T., Calonius, O., & Keränen, J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2001-06
- Volume
- 22
- Issue
- 12
- Pages
- 1507-1514
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2064065049
- Cited by
- 158
- References
- 10
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.