Improvement in the morphology of Ti-based surfaces: a new process to increase in vitro human osteoblast response
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500 · cited 1×
“with the material surface [13].”
Self-citationTopographical control of cells
Curtis, A., & Wilkinson, C. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00144-0 · Cited by 1,405 · cited 1×
“They have defined discontinuity as a radius of curvature less than the average length of a pseudopodium or of the distance part of the sensing elements that control movement [21].”
BackgroundLincks, J. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00144-6 · Cited by 704 · cited 1×
“Consequently, many in vitro evaluations of cell adhesion on substrates with various roughnesses have been performed in order to discern the main surface properties influencing the cell response to implant surfaces [7–12].”
BackgroundAnselme, K., Bigerelle, M., Noel, B., Dufresne, E., Judas, D., Iost, A., & Hardouin, P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200002)49:2<155::aid-jbm2>3.0.co;2-j · Cited by 507
Self-citationAnselme, K., Linez, P., Bigerelle, M., Le Maguer, D., Le Maguer, A., Hardouin, P., Hildebrand, H. F., Iost, A., & Leroy, J. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00042-9 · Cited by 413
Self-citationDegasne, I., Baslé, M. F., Demais, V., Huré, G., Lesourd, M., Grolleau, B., Mercier, L., & Chappard, D. (1999) · Calcified Tissue International · doi:10.1007/s002239900640 · Cited by 328
Effects of metal ions on osteoblast-like cell metabolism and differentiation
Sun, Z. L., Wataha, J. C., & Hanks, C. T. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199701)34:1<29::aid-jbm5>3.0.co;2-p · Cited by 230 · cited 1×
“This is unlikely because the cytocompatibility of titanium is well known [18,19,5] and because we did not observed any difference of CMS adhesion in a direct comparison of EE and polished titanium and Ti6Al4V substrates (Fig.”
Influence of the surface structure of titanium materials on the adhesion of fibroblasts
Eisenbarth, E., Meyle, J., Nachtigall, W., & Breme, J. (1996) · Biomaterials · doi:10.1016/0142-9612(96)87281-4 · Cited by 200 · cited 1×
“Consequently, many in vitro evaluations of cell adhesion on substrates with various roughnesses have been performed in order to discern the main surface properties influencing the cell response to implant surfaces [7–12].”
BackgroundGrowth behavior of fibroblasts on microgrooved polystyrene
Walboomers, X. F., Croes, H. J. E., Ginsel, L. A., & Jansen, J. A. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00093-3 · Cited by 183 · cited 1×
“They hypothesized that the phenomenon of contact guidance was the result of a mechanoreceptive response to surface discontinuities implying the dynamics of the cytoskeleton [23].”
BackgroundFeighan, J. E., Goldberg, V. M., Davy, D., Parr, J. A., & Stevenson, S. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199509000-00015 · Cited by 176
Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits
Suzuki, K., Aoki, K., & Ohya, K. (1997) · Bone · doi:10.1016/s8756-3282(97)00204-4 · Cited by 169 · cited 2×
“Various results have been obtained, depending on the roughness amplitude but also on the method used to produce the surface roughness [1–4,6].”
MethodResponse of rat bone marrow cells to differently roughened titanium discs
Castellani, R., Ruijter, A. E. D., Renggli, H. H., & Jansen, J. J. (1999) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1999.100504.x · Cited by 76 · cited 1×
“Consequently, many in vitro evaluations of cell adhesion on substrates with various roughnesses have been performed in order to discern the main surface properties influencing the cell response to implant surfaces [7–12].”
BackgroundAnselme, K., Noe¨l, B., & Hardouin, P. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008992109670 · Cited by 62
Self-citation
Cited by
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
The interaction of cells and bacteria with surfaces structured at the nanometre scale
Anselme, K., Davidson, P., Popa, A. M., Giazzon, M., Liley, M., & Ploux, L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.001 · Cited by 827
Self-citationImproved bone-forming functionality on diameter-controlled TiO2 nanotube surface
Brammer, K. S., Oh, S., Cobb, C. J., Bjursten, L. M., Heyde, H. V. D., & Jin, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.008 · Cited by 593
Titanium dioxide nanotubes enhance bone bonding in vivo
Bjursten, L. M., Rasmusson, L., Oh, S., Smith, G. C., Brammer, K. S., & Jin, S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32463 · Cited by 356
Zinger, O., Anselme, K., Denzer, A., Habersetzer, P., Wieland, M., Jeanfils, J., Hardouin, P., & Landolt, D. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.111 · Cited by 335
Self-citation
Metadata
- Authors
- Bigerelle, M., Anselme, K., Noël, B., Ruderman, I., Hardouin, P., & Iost, A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2002-04
- Volume
- 23
- Issue
- 7
- Pages
- 1563-1577
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2086496796
- Cited by
- 213
- References
- 13
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.