In vitro and in vivo degradation studies for development of a biodegradable patch based on poly(3-hydroxybutyrate)
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure of human pancreatic lipase
Winkler, F. K., D'Arcy, A., & Hunziker, W. (1990) · Nature · doi:10.1038/343771a0 · Cited by 1,224 · cited 1×
“It has been noted that a SerHisAsp triad constitutes the active center of the catalytic domain of both PHB depolymerase [37] and pancreatic lipase [38].”
BackgroundCrystallization and morphology of a bacterial thermoplastic: poly-3-hydroxybutyrate
Barham, P. J., Keller, A., Otun, E. L., & Holmes, P. A. (1984) · Journal of Materials Science · doi:10.1007/bf01026954 · Cited by 1,080 · cited 1×
“The mass crystallinity of sample films was approximated using the heat of fusion originate from the first scan compared with that of totally crystalline PHB (146 J/g [29]) or PLLA (93 J/g [30]), respectively.”
MethodEngelberg, I., & Kohn, J. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90037-b · Cited by 803
Bacterial polyhydroxyalkanoates
Lee, S. Y. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960105)49:1<1::aid-bit1>3.0.co;2-p · Cited by 779 · cited 1×
“The presence of relatively large amounts of low-molecular weight PHB occurring naturally in human blood as well as the fact that the degradation product, 3-hydroxybutyric acid, is a common metabolite in all higher living beings are further evidence for the nontoxicity of implanted PHB [17].”
BackgroundBioresorbability and biocompatibility of aliphatic polyesters
Vert, M., Li, S. M., Spenlehauer, G., & Guerin, P. (1992) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00701240 · Cited by 770 · cited 2×
“between the two polymers could be explained considering the more rubber-like characteristics of PHB and the glassy state of PLLA as evidenced by their glass transition temperatures [43,45].”
BackgroundGogolewski, S., Jovanovic, M., Perren, S. M., Dillon, J. G., & Hughes, M. K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270904 · Cited by 547
Doi, Y., Kanesawa, Y., Kunioka, M., & Saito, T. (1990) · Macromolecules · doi:10.1021/ma00203a006 · Cited by 515
Li, S., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00701077 · Cited by 488
General crystallization behaviour of poly(l-lactic acid)
Kalb, B., & Pennings, A. J. (1980) · Polymer · doi:10.1016/0032-3861(80)90315-8 · Cited by 421
Biodegradation of polyhydroxyalkanoic acids
Jendrossek, D., Schirmer, A., & Schlegel, H. G. (1996) · Applied Microbiology and Biotechnology · doi:10.1007/s002530050844 · Cited by 397 · cited 2×
“The serine is part of the pentapeptide Gly X1-SerX2-Gly, which has been located in all known PHB depolymerases as well as lipases, esterases and serine proteases [37].”
Background
Cited by
The application of polyhydroxyalkanoates as tissue engineering materials
Chen, G.-Q., & Wu, Q. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.036 · Cited by 1,418
Current progress on bio-based polymers and their future trends
Babu, R. P., O'Connor, K., & Seeram, R. (2013) · Progress in Biomaterials · doi:10.1186/2194-0517-2-8 · Cited by 1,126
Elfaleh, I., Abbassi, F., Habibi, M., Ahmad, F., Guedri, M., Nasri, M., & Garnier, C. (2023) · Results in Engineering · doi:10.1016/j.rineng.2023.101271 · Cited by 1,034
Meereboer, K. W., Misra, M., & Mohanty, A. K. (2020) · Green Chemistry · doi:10.1039/d0gc01647k · Cited by 965
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Polyhydroxyalkanoate (PHA)/Inorganic Phase Composites for Tissue Engineering Applications
Misra, S. K., Valappil, S. P., Roy, I., & Boccaccini, A. R. (2006) · Biomacromolecules · doi:10.1021/bm060317c · Cited by 372
Recycling of Bioplastics: Routes and Benefits
Lamberti, F. M., Román-Ramírez, L. A., & Wood, J. (2020) · Journal of Polymers and the Environment · doi:10.1007/s10924-020-01795-8 · Cited by 365
Brannigan, R. P., & Dove, A. P. (2017) · Biomaterials Science · doi:10.1039/c6bm00584e · Cited by 334
Polyhydroxyalkanoate (PHA) scaffolds with good mechanical properties and biocompatibility
Zhao, K., Deng, Y., Chun Chen, J., & Chen, G.-Q. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00426-x · Cited by 318
Rydz, J., Sikorska, W., Kyulavska, M., & Christova, D. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms16010564 · Cited by 303
“underwent enzymatic hydrolysis [62,63,80–83].”
PHB packaging for the storage of food products
Bucci, D. Z., Tavares, L. B. B., & Sell, I. (2005) · Polymer Testing · doi:10.1016/j.polymertesting.2005.02.008 · Cited by 280
Yang, W., Chen, S., Cheng, G., Vaisocherová, H., Xue, H., Li, W., Zhang, J., & Jiang, S. (2008) · Langmuir · doi:10.1021/la801487f · Cited by 258
A review on the thermomechanical properties and biodegradation behaviour of polyesters
Larrañaga, A., & Lizundia, E. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.109296 · Cited by 257
Wang, Y.-W., Wu, Q., & Chen, G.-Q. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00561-1 · Cited by 250
“PHAs are always biodegradable, but the degradation rate varies with the properties [4, 5 ].”
BackgroundValappil, S. P., Misra, S. K., Boccaccini, A. R., & Roy, I. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.6.853 · Cited by 242
Kaniuk, Ł., & Stachewicz, U. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00757 · Cited by 220
Biodegradation of different formulations of polyhydroxybutyrate films in soil
Altaee, N., El-Hiti, G. A., Fahdil, A., Sudesh, K., & Yousif, E. (2016) · SpringerPlus · doi:10.1186/s40064-016-2480-2 · Cited by 195
Qu, X.-H., Wu, Q., Zhang, K.-Y., & Chen, G. Q. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.02.015 · Cited by 192
Defoirdt, T., Boon, N., Sorgeloos, P., Verstraete, W., & Bossier, P. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.04.026 · Cited by 168
Yu, J., Plackett, D., & Chen, L. X. L. (2005) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2004.12.026 · Cited by 168
Defoirdt, T., Halet, D., Vervaeren, H., Boon, N., Van de Wiele, T., Sorgeloos, P., Bossier, P., & Verstraete, W. (2007) · Environmental Microbiology · doi:10.1111/j.1462-2920.2006.01161.x · Cited by 166
“Moreover, the presence of digestive enzymes has been shown to increase the degradation of PHB about threefold (Freier et al., 2002).”
BackgroundKim, T.-H., Mount, C. W., Gombotz, W. R., & Pun, S. H. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.06.004 · Cited by 164
“As a material that has properties of both low cytotoxicity and biodegradability, PHB is an attractive polymer for biomedical applications [20].”
BackgroundFocarete, M. L., Scandola, M., Dobrzynski, P., & Kowalczuk, M. (2002) · Macromolecules · doi:10.1021/ma020940z · Cited by 119
Review of Hybrid Materials Based on Polyhydroxyalkanoates for Tissue Engineering Applications
Pryadko, A., Surmeneva, M. A., & Surmenev, R. A. (2021) · Polymers · doi:10.3390/polym13111738 · Cited by 102
Metadata
- Authors
- Freier, T., Kunze, C., Nischan, C., Kramer, S., Sternberg, K., Saß, M., Hopt, U. T., & Schmitz, K.-P.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2002-07
- Volume
- 23
- Issue
- 13
- Pages
- 2649-2657
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2034809261
- Cited by
- 241
- References
- 45
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.