Developments in single-drop microextraction
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, this technique has been shown to be applicable to real samples [67].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [67]
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Evolution of solid-phase microextraction technology
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00535-5 · Cited by 787
Analytical Chemistry in a Drop. Solvent Extraction in a Microdrop
Liu, H., & Dasgupta, P. K. (1996) · Analytical Chemistry · doi:10.1021/ac960145h · Cited by 751
He, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 681
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Jeannot, M. A., & Cantwell, F. F. (1997) · Analytical Chemistry · doi:10.1021/ac960814r · Cited by 558
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Solid-phase microextraction: a promising technique for sample preparation in environmental analysis
de Fátima Alpendurada, M. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00453-2 · Cited by 449
Cited by
Items 101–200 of 378
Xu, J., Liang, P., & Zhang, T. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.06.047 · Cited by 84
Aguilera‐Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.030 · Cited by 79
Zang, X., Wang, J., Wang, O., Wang, M., Ma, J., Xi, G., & Wang, Z. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2296-1 · Cited by 75
A SDME/GC–MS methodology for determination of organophosphate and pyrethroid pesticides in water
Pinheiro, A. D. S., da Rocha, G. O., & de Andrade, J. B. (2011) · Microchemical Journal · doi:10.1016/j.microc.2011.05.019 · Cited by 88
“The single drop microextraction (SDME), is a relatively new technique that has been increasingly used in the analysis of pesticides because it is simple, cheap, fast, effective and virtually free of organic solvents [9] and currently has become a powerful tool to analyze different groups of analytes in various matrice…”
MethodFarahani, H., Yamini, Y., Shariati, S., Khalili-Zanjani, M. R., & Mansour-Baghahi, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.08.001 · Cited by 74
Anthemidis, A. N., & Miró, M. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920802352598 · Cited by 74
Psillakis, E., Mantzavinos, D., & Kalogerakis, N. E. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.015 · Cited by 77
Self-citationJen, J., & Liu, T.-C. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.06.029 · Cited by 78
Tavakoli, L., Yamini, Y., Ebrahimzadeh, H., & Shariati, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.04.036 · Cited by 71
Wang, L., Wang, Z., Zhang, H., Li, X., & Zhang, H. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.05.030 · Cited by 71
Cruz‐Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.06.035 · Cited by 70
Wu, J. J., Lu, J. J., Wilson, C., Lin, Y., & Lu, H. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.08.004 · Cited by 70
Ramos‐Payán, M., Jensen, H. M., Petersen, N. J., Hansen, S. H., & Pedersen‐Bjergaard, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.023 · Cited by 74
Fragueiro, S., Lavilla, I., & Bendicho, C. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.03.002 · Cited by 70
Opportunities and shortcomings of ionic liquids in single-drop microextraction
Marcinkowski, Ł., Pena-Pereira, F., Kloskowski, A., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.03.024 · Cited by 69
Jalali‐Heravi, M., & Sereshti, H. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.096 · Cited by 72
Aguilera‐Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.071 · Cited by 70
Ghambarian, M., Khalili-Zanjani, M. R., Yamini, Y., Esrafili, A., & Yazdanfar, N. (2010) · Talanta · doi:10.1016/j.talanta.2009.11.056 · Cited by 67
Amvrazi, E. G., & Tsiropoulos, N. G. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.07.070 · Cited by 67
Fan, Z. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.034 · Cited by 76
Vora-adisak, N., & Varanusupakul, P. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.009 · Cited by 72
Prosen, H. (2014) · Molecules · doi:10.3390/molecules19056776 · Cited by 69
Leng, G., Lui, G., Chen, Y., Yin, H., & Dan, D. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200234 · Cited by 69
Jiang, H., Hu, B., Chen, B., & Zu, W. (2008) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2008.04.011 · Cited by 72
Yao, J., Xu, H., Lv, L., Song, D., Cui, Y., Zhang, T., & Feng, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.007 · Cited by 64
Zhao, E., Shan, W., Jiang, S., Liu, Y., & Zhou, Z. (2006) · Microchemical Journal · doi:10.1016/j.microc.2006.03.008 · Cited by 64
Zhang, S., Li, C., Song, S., Feng, T., Wang, C., & Wang, Z. (2010) · Anal. Methods · doi:10.1039/b9ay00115h · Cited by 63
Jiang, H., & Hu, B. (2007) · Microchimica Acta · doi:10.1007/s00604-007-0785-0 · Cited by 66
“Recent progress on the LPME principle, instrumental design and application are reviewed by Psillakis and Kalogerakis [ 11 , 12].”
MethodBiparva, P., Ehsani, M., & Hadjmohammadi, M. R. (2012) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2012.04.002 · Cited by 69
“However, there are also some disadvantages with these methods: fast stirring speed tends to break up the organic drop (Psillakis and Kalogerakis, 2002); air bubbles are sometimes formed in SDME or HF-LPME (Shen and Hian, 2002); extraction is time-consuming, and equilibrium could not be attained even after extended ext…”
BackgroundZhang, J., Su, T., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.045 · Cited by 63
Dynamic headspace liquid-phase microextraction of alcohols
Saraji, M. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.11.026 · Cited by 68
Basheer, C., Alnedhary, A. A., Rao, B. S. M., & Lee, H. K. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.10.006 · Cited by 66
Simultaneous determination of pesticide multiresidues in white wine and rosé wine by SDME/GC-MS
dos Anjos, J. P., & de Andrade, J. B. (2015) · Microchemical Journal · doi:10.1016/j.microc.2015.01.009 · Cited by 60
Extraction for analytical scale sample preparation (IUPAC Technical Report)
Poole, C. F., Mester, Z., Miró, M., Pedersen‐Bjergaard, S., & Pawliszyn, J. B. (2016) · Pure and Applied Chemistry · doi:10.1515/pac-2015-0705 · Cited by 69
Jermak, S., Pranaitytė, B., & Padarauskas, A. (2006) · Electrophoresis · doi:10.1002/elps.200600295 · Cited by 59
Wu, L., Hu, M., Li, Z., Song, Y., Yu, C., Zhang, H., Yu, A., Ma, Q., & Wang, Z. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.07.055 · Cited by 61
“The interfacial layer will vary with the change of flow rate of solution, which will affect the mass transfer of analytes in both phases involved in extraction (Psillakis & Kalogerakis, 2002).”
BackgroundApplication of liquid-phase microextraction to the analysis of trihalomethanes in water
Tor, A., & Aydın, M. E. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.05.054 · Cited by 63
Solvent-bar microextraction—Using a silica monolith as the extractant phase holder
Xu, L., & Lee, H. K. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.074 · Cited by 60
Pena‐Pereira, F., Lavilla, I., & Bendicho, C. (2008) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2008.01.005 · Cited by 58
“This technique offers several advantages such as minimum organic solvent consumption, simplicity, and a high sampling frequency as compared to traditional liquid–liquid extraction techniques [2].”
MethodLiang, P., Liu, R., & Cao, J. (2007) · Microchimica Acta · doi:10.1007/s00604-007-0807-y · Cited by 61
“More recently, efforts have been placed on miniaturizing the LLE extraction procedure by greatly reducing the solvent to aqueous phase ratio, leading to the development of single drop microextraction (SDME) or liquid-phase microextraction (LPME) methodology [ 9 , 10].”
MethodMadani-Tonekaboni, M., Kamankesh, M., & Mohammadi, A. (2015) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2014.12.004 · Cited by 60
“In fact, the addition of salt to the sample solution due to the salting-out affect, increases extraction efficiency (Psillakis and Kalogerakis, 2002).”
BackgroundCao, J., Liang, P., & Liu, R. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.07.064 · Cited by 57
Marlow, M., & Hurtubise, R. J. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.09.054 · Cited by 59
Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples
Vidal, L., Domini, C. E., Grané, N., Psillakis, E., & Canals, A. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.066 · Cited by 70
Self-citationFarajzadeh, M. A., Khoshmaram, L., & Mogaddam, M. R. A. (2012) · Journal of Separation Science · doi:10.1002/jssc.201100374 · Cited by 54
Fiamegos, Y. C., Nanos, C. G., & Stalikas, C. D. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.09.013 · Cited by 57
Wang, C., Li, C., Zang, X., Han, D., Liu, Z., & Wang, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.027 · Cited by 56
Xu, M., Liu, J., & Lu, J. (2013) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2013.803978 · Cited by 59
Berhanu, T., Liu, J., Romero‐González, R., Megersa, N., & Jönsson, J. Å. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.10.082 · Cited by 59
Chatzimitakos, T. G., Pierson, S. A., Anderson, J. L., & Stalikas, C. D. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.08.013 · Cited by 54
Mohammadi, A., Tavakoli, R., Kamankesh, M., Rashedi, H., Attaran, A., & Delavar, M. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.045 · Cited by 54
Contribution to aroma potential of Andean blackberry (Rubus glaucus Benth.)
Meret, M., Brat, P., Mertz, C., Lebrun, M., & Gunata, Z. Y. (2010) · Food Research International · doi:10.1016/j.foodres.2010.11.016 · Cited by 59
Pena‐Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Food Chemistry · doi:10.1016/j.foodchem.2009.07.038 · Cited by 55
Saraji, M., & Tansazan, N. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900438 · Cited by 52
Varanusupakul, P., Vora-adisak, N., & Pulpoka, B. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.025 · Cited by 57
Wei, G., Li, Y., & Wang, X. (2007) · Journal of Separation Science · doi:10.1002/jssc.200700291 · Cited by 52
Farooq, M. Q., Zeger, V. R., & Anderson, J. L. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462588 · Cited by 51
Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Reviews in Analytical Chemistry · doi:10.1515/revac-2020-0101 · Cited by 50
“In addition, this technique has been shown to be applicable to real samples [67].”
BackgroundMethodAsadi, M., Dadfarnia, S., & Shabani, A. M. H. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.05.014 · Cited by 52
Liquid-phase microextraction based on solidified floating drops of organic solvents
Ghambarian, M., Yamini, Y., & Esrafili, A. (2013) · Microchimica Acta · doi:10.1007/s00604-013-0969-8 · Cited by 57
Chen, H., Chen, R., Feng, R. Y., & Li, S. (2009) · Chromatographia · doi:10.1365/s10337-009-1154-4 · Cited by 51
Šrámková, I. H., Horstkotte, B., Sklenářová, H., Solich, P., & Kolev, S. D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.039 · Cited by 53
Yazdi, A. S., & Es’haghi, Z. (2006) · Chromatographia · doi:10.1365/s10337-006-0801-2 · Cited by 55
Li, Y., Hu, J., Liu, X., Fu, L., Zhang, X., & Wang, X. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800112 · Cited by 49
Liu, Y., Hashi, Y., & Lin, J. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.01.005 · Cited by 49
Pena‐Pereira, F., Lavilla, I., & Bendicho, C. (2008) · Microchimica Acta · doi:10.1007/s00604-008-0036-z · Cited by 49
“This positive effect could be attributed to the salting out effect [ 14 ].”
BackgroundMethodAzooz, E. A., Al-Wani, H. S. A., Gburi, M. S., & Al-Muhanna, E. H. B. (2022) · Open Chemistry · doi:10.1515/chem-2022-0174 · Cited by 53
Clement, R. E., & Hao, C. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00063-6 · Cited by 54
Li, C., Jin, F., & Snyder, S. A. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.07.021 · Cited by 50
Recent Advances in Headspace Gas Chromatography
Wang, Y., McCaffrey, J., & Norwood, D. L. (2008) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826070802129092 · Cited by 48
Zhao, R., Yuan, J.-P., Li, H., Wang, X., Jiang, T., & Lin, J. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1151-0 · Cited by 52
Hasheminasab, K. S., & Fakhari, A. R. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.11.061 · Cited by 53
“LPME has been accomplished either by extraction 56 into small water immiscible drops of organic solvent, hanging (single-drop microextraction) 57 [4,5] or dispersed (dispersive liquid–liquid microextraction) [6,7], or into small volumes of 58 acceptor solution inside the lumen of porous hollow fibers (hollow fiber liq…”
MethodCao, J., Qi, M., Zhang, Y., Zhou, S., Shao, Q., & Fu, R. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.01.040 · Cited by 46
Lin, X., Chen, X., Huo, X., Yu, Z., Bi, K., & Li, Q. (2011) · Journal of Separation Science · doi:10.1002/jssc.201000590 · Cited by 46
Vickackaite, V., & Pusvaskiene, E. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900360 · Cited by 45
Yang, M., Zhang, P., Hu, L., Lu, R., Zhou, W., Zhang, S., & Gao, H. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.07.076 · Cited by 46
Capillary electrophoretic determination of ammonia using headspace single-drop microextraction
Pranaitytė, B., Jermak, S., Naujalis, E., & Padarauskas, A. (2006) · Microchemical Journal · doi:10.1016/j.microc.2006.10.001 · Cited by 45
Sekar, R., & Wu, H. (2006) · Analytical Chemistry · doi:10.1021/ac060123n · Cited by 45
Saleh, A., Yamini, Y., Faraji, M., Shariati, S., & Rezaee, M. B. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.04.039 · Cited by 51
Yazdi, A. S., Assadi, H., Es’haghi, Z., & Danesh, N. M. (2012) · Journal of Separation Science · doi:10.1002/jssc.201101099 · Cited by 44
Mohammadi, M., Kamankesh, M., Hadian, Z., Mortazavian, A. M., & Mohammadi, A. (2016) · Chromatographia · doi:10.1007/s10337-016-3217-7 · Cited by 47
A ionic liquid for dispersive liquid-liquid microextraction of phenols
Fan, Y. C., Chen, M. L., Shen-Tu, C., & Zhu, Y. (2009) · Journal of Analytical Chemistry · doi:10.1134/s1061934809100074 · Cited by 43
García-López, M., Rodríguez, I., & Cela, R. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.07.026 · Cited by 49
Shrivas, K. K., & Wu, H. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.10.032 · Cited by 45
Ferrofluid-based liquid-phase microextraction
Shi, Z., Zhang, Y., & Lee, H. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.09.049 · Cited by 43
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Wang, H., Liu, X., Nan, K., Chen, B., He, M., & Hu, B. (2017) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c6ja00077k · Cited by 45
Cheng, J., Xiao, J., Zhou, Y., Xia, Y., Guo, F., & Li, J. (2010) · Microchimica Acta · doi:10.1007/s00604-010-0458-2 · Cited by 41
“These drawbacks have led to the development of the miniaturization of sample preparation process, such as solid-phase microextraction (SPME) [9, 10], single drop microextraction (SDME) [11–13], liquidphase microextraction (LPME) [14, 15].”
BackgroundFernandes, V. C., Subramanian, V., Mateus, N. F. D. C. B., Domingues, V. F., & Delerue-Matos, C. M. (2012) · Microchimica Acta · doi:10.1007/s00604-012-0810-9 · Cited by 41
“On the other hand, a drop volume of 1 μL is consistent with GC instruments [42].”
BackgroundYang, F., Liu, R., Tan, Z., Wen, X., Zheng, C., & Lv, Y. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.07.059 · Cited by 41
Green chromatography for the analysis of foods of animal origin
Armenta, S., & de la Guárdia, M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.06.012 · Cited by 45
Bioanalytical Applications of Microextraction Techniques: A Review of Reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Chromatographia · doi:10.1007/s10337-020-03884-1 · Cited by 40
Wu, L., Hu, M., Li, Z., Song, Y., Zhang, H., Yu, A., Ma, Q., & Wang, Z. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.06.062 · Cited by 43
Sobhi, H. R., Yamini, Y., Esrafili, A., & Adib, M. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.07.029 · Cited by 39
Chang, Q., Feng, T., Song, S., Zhou, X. G., Wang, C., & Wang, Z. (2010) · Microchimica Acta · doi:10.1007/s00604-010-0430-1 · Cited by 39
“However, there are also some disadvantages in them: fast stirring speed tends to break up the organic drop and air bubbles are sometimes formed in SDME [ 34 ]; in HF-LPME and SPME, the contact surface of the fiber is very small, and thus the equilibrium could not be attained even after a long time of extraction in mos…”
BackgroundZhou, J., Liu, R., Song, G., & Zhang, M. (2009) · Analytical Letters · doi:10.1080/00032710903060677 · Cited by 41
Chaichi, M., Mohammadi, A., & Hashemi, M. (2012) · Microchemical Journal · doi:10.1016/j.microc.2012.12.009 · Cited by 37
Hashemi, M., Jahanshahi, N., & Habibi, A. (2012) · Desalination · doi:10.1016/j.desal.2011.12.017 · Cited by 36
Yazdi, A. S., Assadi, H., & Ibrahim, W. A. W. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie202856h · Cited by 38
Xu, L., Basheer, C., & Lee, H. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.07.072 · Cited by 38
Metadata
- Authors
- Psillakis, E., & Kalogerakis, N.
- Affiliations
- Technical University of Crete (GR)
- Corresponding author
- Kalogerakis, N
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2002-01
- Volume
- 21
- Issue
- 1
- Pages
- 54-64
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2014486915
- Cited by
- 373
- References
- 27
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 6 · 2021: 5 · 2020: 6 · 2019: 11 · 2018: 8 · 2017: 7 · 2016: 8 · 2015: 13 · 2014: 19 · 2013: 18 · 2012: 31
- FWCI
- 12.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- TrAC Trends in Analytical Chemistry (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- single-drop microextraction, solvent-free sample preparation, sample preparation, method optimization, extraction conditions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.