Electropermeabilization of cell membranes
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electroporation and Electrofusion in Cell Biology
(1989) · Springer eBooks · doi:10.1007/978-1-4899-2528-2 · Cited by 942
Dielectric Breakdown of Cell Membranes
Zimmermann, U., Pilwat, G., & Riemann, F. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85956-4 · Cited by 762
Abiror, I. G., Arakelyan, V. B., Chernomordik, L. V., Chizmadzhev, Y. A., Pastushenko, V. F., & Tarasevich, M. R. (1979) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(79)85005-9 · Cited by 540
Chang, D. C., & Reese, T. S. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82348-1 · Cited by 522
Electrochemotherapy, a new antitumor treatment. First clinical phase I-II trial
Belehradek, M., Domenge, C., Luboinski, B., Orlowski, S., Belehradek, J., & Mir, L. M. (1993) · Cancer · doi:10.1002/1097-0142(19931215)72:12<3694::aid-cncr2820721222>3.0.co;2-2 · Cited by 461
Transient electropermeabilization of cells in culture
Orlowski, S., Belehradek, J., Paoletti, C., & Mir, L. M. (1988) · Biochemical Pharmacology · doi:10.1016/0006-2952(88)90344-9 · Cited by 444
In vivo electrically mediated protein and gene transfer in murine melanoma
Rols, M.-P., Delteil, C., Golzio, M., Dumond, P., Cros, S., & Teissie, J. (1998) · Nature Biotechnology · doi:10.1038/nbt0298-168 · Cited by 421
Self-citationElectropermeabilization of mammalian cells. Quantitative analysis of the phenomenon
Rols, M. P., & Teissié, J. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82451-6 · Cited by 394 · cited 7×
“This reaction 4 negligible, an additive effect of successive pulses between plasmids and electropermeabilized memis present [26].”
BackgroundMethodInfluentialSelf-citationTeissié, J., & Rols, M. P. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81052-x · Cited by 374 · cited 5×
“the cell is a sphere, the g(l) value is less than 1 [19].”
BackgroundInfluentialSelf-citationHemolysis of human erythrocytes by transient electric field.
Kinosita, K., & Tsong, T. Y. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.5.1923 · Cited by 327
Cited by
Novel mechanisms and devices to enable successful transdermal drug delivery
Barry, B. W. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00167-1 · Cited by 1,240
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Membrane Electroporation: A Molecular Dynamics Simulation
Tarek, M. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.050617 · Cited by 515
Kim, T., Momin, E., Choi, J., Yuan, K., Zaidi, H., Kim, J., Park, M., Lee, N., McMahon, M. T., Quinones-Hinojosa, A., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1084095 · Cited by 511
Sequential Finite Element Model of Tissue Electropermeabilization
Sel, D., Cukjati, D., Batiuskaite, D., Slivnik, T., Mir, L. M., & Miklavcic, D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845212 · Cited by 284
Biophysical Injury Mechanisms in Electrical Shock Trauma
Lee, R. C., Zhang, D., & Hannig, J. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.477 · Cited by 252
Drug delivery routes in skin: a novel approach
Barry, B. W. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00113-8 · Cited by 248
Gene Electrotransfer: A Mechanistic Perspective
Rosazza, C., Haberl Meglic, S., Zumbusch, A., Rols, M.-P., & Miklavcic, D. (2016) · Current Gene Therapy · doi:10.2174/1566523216666160331130040 · Cited by 209
“Therefore, the gene expression can be written, for field conditions not affecting to large extend the cell viability, [118, 172, 213]:”
BackgroundInfluentialSelf-citationNumerical Determination of Transmembrane Voltage Induced on Irregularly Shaped Cells
Pucihar, G., Kotnik, T., Valič, B., & Miklavčič, D. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9076-2 · Cited by 209
In vitro electroporation detection methods – An overview
Batista Napotnik, T., & Miklavčič, D. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2017.12.005 · Cited by 187
“but the cell's own components, ions andmolecules such as ATP, leak out of the cell to the cell's surroundings [245], which has led to numerous”
BackgroundKinetics of Transmembrane Transport of Small Molecules into Electropermeabilized Cells
Pucihar, G., Kotnik, T., Miklavčič, D., & Teissié, J. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.135541 · Cited by 179
“Bandwidths of the amplifier: (1 )1 17 kHz, (2 )3 9 kHz, (3) 7.7 kHz, and ( 4 ) 3.5 kHz.”
InfluentialSelf-citationPucihar, G., Miklavcic, D., & Kotnik, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2014244 · Cited by 175
“THE DISTRIBUTION of the voltage on the membranes of excitable or nonexcitable biological cells can be of interest in various theoretical and experimental settings, such as the activation of voltage-gated membrane channels, cardiac cell stimulation, or cell membrane electroporation [1]–[7].”
BackgroundTerreno, E., Geninatti Crich, S., Belfiore, S., Biancone, L., Cabella, C., Esposito, G., Manazza, A. D., & Aime, S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20793 · Cited by 170
“Electroporation is widely used in cellular biology laboratories as a route to deliver hydrophilic xenobiotics into the cellular cytoplasm (10,11).”
BackgroundAndré, F. M., Gehl, J., Sersa, G., Préat, V., Hojman, P., Eriksen, J., Golzio, M., Cemazar, M., Pavselj, N., Rols, M.-P., et al. (2008) · Human Gene Therapy · doi:10.1089/hum.2008.060 · Cited by 164
“Indeed, this effect of the lag can be analyzed through the theoretical knowledge of membrane electropermeabilization: it is widely accepted that (1) the external field strength determines the area of the cell membrane that will be electropermeabilized (Foster and Schwann 1989; Kotnik et al., 1997; Teissie et al., 1999…”
Self-citationCell Injury by Electric Forces
LEE, R. C. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1363.007 · Cited by 100
Canatella, P. J., Black, M. M., Bonnichsen, D. M., McKenna, C., & Prausnitz, M. R. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74374-x · Cited by 89
“A few decades of study have provided rigorous theoretical models of electroporation at the membrane level (Weaver and Chizmadzhev, 1996) and largely phenomenological understanding at the cellular level (Teissie et al., 1999), but relatively little mechanistic work has been done at the tissue level.”
Background
Metadata
- Authors
- Teissié, J., Eynard, N., Gabriel, B., & Rols, M. P.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 35
- Issue
- 1
- Pages
- 3-19
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2093001890
- Cited by
- 221
- References
- 58
- FWCI
- 0.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.