Elastographic characterization of HIFU-induced lesions in canine livers
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationThermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498 · cited 2×
“The quantity R equals 0.5 for temperatures greater than 43°C and 0.25 for temperatures below 43°C (Sapareto and Dewey 1984).”
BackgroundMethodInfluentialElastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703 · cited 1×
“The slope of these curves determined the elastic moduli of the selected regions for a range of applied strain (Krouskop et al. 1998).”
BackgroundSelf-citationElastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940 · cited 2×
“This has been successfully demonstrated in vivo (Garra et al. 1997).”
BackgroundSelf-citationProton Resonance Shift of Water in the Gas and Liquid States
Hindman, J. C. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1726676 · Cited by 661 · cited 2×
“The temperature sensitivity coefficient for the proton resonance frequency of water was used (aT 5 20.01 ppm/°C) (Hindman 1966).”
MethodInfluentialImaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514 · cited 1×
“Recently, methods to map information related to the elastic properties of soft tissues have been proposed, as reviewed by Gao et al. (1996).”
MethodProduction of Focal Destructive Lesions in the Central Nervous System With Ultrasound
Fry, W. J., Mosberg, W. H., Barnard, J. W., & Fry, F. J. (1954) · Journal of Neurosurgery · doi:10.3171/jns.1954.11.5.0471 · Cited by 457 · cited 3×
“It has been known since the early 1950s that focusing high-intensity ultrasound beams can heat or destroy volumes of tissue at depths up to 10 cm and at exposure times on the order of seconds (Fry et al. 1950, 1954; Lele 1967).”
BackgroundTwo-dimensional temperature estimation using diagnostic ultrasound
Simon, C., VanBaren, P., & Ebbini, E. S. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710592 · Cited by 433 · cited 1×
“Recently, new ultrasonic techniques for beam guidance by the mean of temperature mapping were proposed (Ueno et al. 1990; Straube and Arthur 1994; Seip and Ebbini 1995; Moreno et al. 1995; Simon et al. 1998).”
MethodA Least-Squares Strain Estimator for Elastography
Kallel, F., & Ophir, J. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900303 · Cited by 432 · cited 1×
“This permitted the generation of elastograms characterized by high signal-tonoise ratio and CNR, with a relatively small loss of spatial resolution (Kallel and Ophir 1997).”
BackgroundSelf-citationThe threshold for thermally significant cavitation in dog's thigh muscle in vivo
Hynynen, K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90123-e · Cited by 430 · cited 3×
“This was presumably related to the formation of gas bubbles due to vaporization and/or cavitation (Hynynen 1991; Gertner et al. 1998).”
BackgroundNoninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound
Seip, R., & Ebbini, E. S. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398644 · Cited by 384 · cited 1×
“Recently, new ultrasonic techniques for beam guidance by the mean of temperature mapping were proposed (Ueno et al. 1990; Straube and Arthur 1994; Seip and Ebbini 1995; Moreno et al. 1995; Simon et al. 1998).”
MethodTer Haar, G. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02010-1 · Cited by 330 · cited 3×
“Consequently, lesions for which the temperature exceeded 100°C, or those in which cavitation occurred, generally show a different shape and appearance compared to lesions created by a purely thermal damage mechanism (Hill and ter Haar 1995; Malcolm and ter Haar 1996; Chapelon et al. 1999).”
BackgroundMethodA clinical, noninvasive, MR imaging-monitored ultrasound surgery method
Hynynen, K., Freund, W., Cline, H., Chung, A., Watkins, R., Vetro, J., & Jolesz, F. (1996) · RadioGraphics · doi:10.1148/radiographics.16.1.185 · Cited by 327 · cited 3×
“The development of magnetic resonance imaging (MRI) methods to monitor temperature changes in the target region in real-time has marked a turning point in the history of HIFU (Cline et al. 1995; Hynynen et al. 1996; Hynynen 1996).”
MethodMR-Guided Focused Ultrasound Surgery
Cline, H. E., Schenck, J. F., Hynynen, K., Watkins, R. D., Souza, S. P., & Jolesz, F. A. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199211000-00024 · Cited by 314
Focused US system for MR imaging-guided tumor ablation.
Cline, H. E., Hynynen, K., Watkins, R. D., Adams, W. J., Schenck, J. F., Ettinger, R. H., Freund, W. R., Vetro, J. P., & Jolesz, F. A. (1995) · Radiology · doi:10.1148/radiology.194.3.7862971 · Cited by 276 · cited 3×
“The development of magnetic resonance imaging (MRI) methods to monitor temperature changes in the target region in real-time has marked a turning point in the history of HIFU (Cline et al. 1995; Hynynen et al. 1996; Hynynen 1996).”
MethodMR temperature mapping of focused ultrasound surgery
Cline, H. E., Hynynen, K., Hardy, C. J., Watkins, R. D., Schenck, J. F., & Jolesz, F. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310608 · Cited by 260 · cited 2×
“…as ISAL by Hill et al. 1994) was calculated using the equation: ISAL 5 0.867 W D2 , (1) where D is the 26 dB beam dimension (;2 mm in our system) and W is the acoustic power output of the transducer, calculated from the RF power, assuming an efficiency of the transducer of 60% (Cline et al. 1994).”
MethodInfluentialHistology of Cerebral Lesions Produced by Focused Ultrasound.
Lynn, J. G., & PUTNAM, T. J. (1944) · PubMed Central · Cited by 219
Fundamental Neurological Research and Human Neurosurgery Using Intense Ultrasound
Fry, W. J., & Fry, F. J. (1960) · IRE Transactions on Medical Electronics · doi:10.1109/iret-me.1960.5008041 · Cited by 209 · cited 1×
“The first HIFU studies and experiments were limited only to neurological and neurosurgical applications, for which high precision and tissue selectivity were re- quired (Lynn and Putnam 1944; Fry et al. 1954; Fry and Fry 1960).”
BackgroundChung, A. H., Hynynen, K., Colucci, V., Oshio, K., Cline, H. E., & Jolesz, F. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360513 · Cited by 198 · cited 1×
“The mechanical damage mechanism is considered to be more violent and more effective than the thermal one (Wells 1977; Prat et al. 1991, 1994; Cathignol et al. 1995).”
BackgroundTreatment of localised prostate cancer with transrectal high intensity focused ultrasound
Chapelon, J. Y., Ribault, M., Birer, A., Vernier, F., Souchon, R., & Gelet, A. (1999) · European Journal of Ultrasound · doi:10.1016/s0929-8266(99)00005-1 · Cited by 166 · cited 2×
“Consequently, lesions for which the temperature exceeded 100°C, or those in which cavitation occurred, generally show a different shape and appearance compared to lesions created by a purely thermal damage mechanism (Hill and ter Haar 1995; Malcolm and ter Haar 1996; Chapelon et al. 1999).”
BackgroundFundamental mechanical limitations on the visualization of elasticity contrast in elastography
Ponnekanti, H., Ophir, J., Huang, Y., & Céspedes, I. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00136-2 · Cited by 156 · cited 2×
“This hypothesis is confirmed from observations that larger lesions are typically visible in several contiguous transverse slices across the ultrasound beam axis, and they appear in fewer slices if scanned and cut longitudinally along the beam axis.”
BackgroundSelf-citationAn analysis of elastographic contrast-to-noise ratio
Varghese, T., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00047-7 · Cited by 154 · cited 4×
“The possibility of detecting small changes in the tissue elastic properties is mostly due to the high CNR provided by elastography (Varghese and Ophir 1998).”
BackgroundMethodSelf-citationTumor irradiation with intense ultrasound
Fry, F. J., & Johnson, L. K. (1978) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(78)90022-4 · Cited by 154 · cited 1×
“Only recently, after the further development of hyperthermia modalities, the possibility of using this technology for the ablation of tumors in soft tissue has been considered (Fry and Johnson 1978; Corry et al. 1984).”
BackgroundFundamental limitations on the contrast-transfer efficiency in elastography: An analytic study
Kallel, F., Bertrand, M., & Ophir, J. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02079-9 · Cited by 153 · cited 1×
“Due to the contrast-transfer–efficiency (CTE) limitation (Ponnekanti et al. 1995; Kallel et al. 1996), for the 110-”
BackgroundSelf-citationTemperature rise recorded during lesion formation by high-intensity focused ultrasound
Clarke, R. L., & ter Haar, G. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00198-6 · Cited by 151
Fry, W. J., Wulff, V. J., Tucker, D. M., & Fry, F. J. (1950) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906707 · Cited by 130 · cited 1×
“It has been known since the early 1950s that focusing high-intensity ultrasound beams can heat or destroy volumes of tissue at depths up to 10 cm and at exposure times on the order of seconds (Fry et al. 1950, 1954; Lele 1967).”
BackgroundHeat-induced changes in the mechanics of a collagenous tissue
Chen, S., & Humphrey, J. D. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00121-8 · Cited by 95
Elastographic Imaging of Low-Contrast Elastic Modulus Distributions in Tissue
Kallel, F., Ophir, J., Magee, K., & Krouskop, T. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00287-1 · Cited by 87
Self-citationPerfusion changes in human skeletal muscle during reactive hyperemia measured by echo‐planar imaging
Toussaint, J., Kwong, K. K., M’Kparu, F., Weisskoff, R. M., LaRaia, P. J., & Kantor, H. L. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350109 · Cited by 82
Shear acoustic properties of soft biological tissues in medical diagnostics
Sarvazyan, A. P. (1993) · The Journal of the Acoustical Society of America · doi:10.1121/1.406353 · Cited by 81
Human Cancer Treatment with Ultrasound
Corry, P. M., Jabboury, K., Armour, E. P., & Kong, J. S. (1984) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1984.31529 · Cited by 64 · cited 1×
“Only recently, after the further development of hyperthermia modalities, the possibility of using this technology for the ablation of tumors in soft tissue has been considered (Fry and Johnson 1978; Corry et al. 1984).”
BackgroundNorberg, M., H�ggman, M., Andersson, T., Busch, C., & Magnusson, A. (1993) · European Radiology · doi:10.1007/bf00169792 · Cited by 17
Cited by
High-intensity focused ultrasound in the treatment of solid tumours
Kennedy, J. E. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1591 · Cited by 1,282
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationImaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Self-citation
Metadata
- Authors
- Righetti, R., Kallel, F., Stafford, R. J., Price, R. E., Krouskop, T. A., Hazle, J. D., & Ophir, J.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 1999-09
- Volume
- 25
- Issue
- 7
- Pages
- 1099-1113
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2140678955
- Cited by
- 193
- References
- 32
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.