CoChat

Ion sensitive field effect transducer-based biosensors

Yuqing, Miao, Jianguo, Guan, Jianrong, Chen · 2003 · Biotechnology Advances
Cited by 171

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0734-9750(03)00103-4

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Research works printed but not linked: 12

  1. Guo, 1997, Nanoscale silicon field effect transistors fabricated using imprint lithography, Appl. Phys. Lett., 71, 1881, 10.1063/1.119426 · doi:10.1063/1.119426
  2. Kimura, 1989, A novel blood glucose monitoring method: an ISFET biosensor application to transcutaneous effusion fluid, J. Electrochem. Soc., 6, 1744, 10.1149/1.2097003 · doi:10.1149/1.2097003
  3. Lauwers, 2001, A CMOS multiparameter biochemical microsensor with temperature control and signal interfacing, IEEE J. Solid State Circuits, 36, 2030, 10.1109/4.972154 · doi:10.1109/4.972154
  4. Liu, 2001, Organic field-effect transistors based on Langmuir–Blodgett films of substituted phthalocyanines, Sens. Actuators, B, 80, 202, 10.1016/S0925-4005(01)00913-3 · doi:10.1016/s0925-4005(01)00913-3
  5. Maupas, 1996, Impedance analysis of Si/SiO2 heterostructures grafted with antibodies: an approach for immunosensor development, J. Electrochem. Soc., 406, 53
  6. Schyberg, 1995, Impedance analysis of Si/Sio2 structures grafted with biomolecules for the elaboration of an immunosensor, Sens. Actuators, B, 26–27, 457, 10.1016/0925-4005(94)01639-Y · doi:10.1016/0925-4005(94)01639-y
  7. Sibbald, 1986, Recent advances in field-effect chemical microsensors, J. Mol. Electron., 2, 51
  8. Simonis, 2001, A hybrid thin-film pH sensor with integrated thick-film reference, Sensors, 1, 183, 10.3390/s10600183 · doi:10.3390/s10600183
  9. Sprenkels A, Pijanowska D, van der Linden H, Olthuis W, Bergveld P. The comprehensive integration of microdialysis membranes with silicon sensors. http://www.bios.el.utwente.nl, 2003. · doi:10.1016/s0166-526x(03)80120-4
  10. Valdés-Perezgasga, 2000, ISFET applications in biological matter: an overview, J. Mex. Soc. Instrum., 4, 10
  11. Van den Vlekkert, 1992, Multi-ion sensing device for horticultural application based upon chemical modification and special packaging of ISFETs, Sens. Actuators, B, 6, 34, 10.1016/0925-4005(92)80027-U · doi:10.1016/0925-4005(92)80027-u
  12. Vianello, 1996, Potentiometric detection of formaldehyde in air by an aldehyde dehydrogenase FET, Sens. Actuators, B, 37, 49, 10.1016/S0925-4005(97)80071-8 · doi:10.1016/s0925-4005(97)80071-8

Cited by

Metadata

Authors
Yuqing, M., Jianguo, G., & Jianrong, C.
Venue
Biotechnology Advances
Publisher
Elsevier BV
Published
2003-09
Volume
21
Issue
6
Pages
527-534
ISSN
0734-9750 (ISSN-L)
OpenAlex
W1976143019
Cited by
171
References
22
FWCI
2.58
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.