Addition of paclitaxel to contrast media prevents restenosis after coronary stent implantation
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Rowinsky, E. K., & Donehower, R. C. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504133321507 · Cited by 1,924 · cited 3×
“Paclitaxel is widely used in antineoplastic chemotherapy (3).”
BackgroundSchwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852 · cited 1×
“Polymeric matrixes on the stent embedding the antiproliferative drug itself could induce inflammation and thrombosis (10).”
BackgroundStent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Heldman, A. W., Cheng, L., Jenkins, G. M., Heller, P. F., Kim, D.-W., Ware, M., Nater, C., Hruban, R. H., Rezai, B., Abella, B. S., et al. (2001) · Circulation · doi:10.1161/01.cir.103.18.2289 · Cited by 435 · cited 3×
“Preclinical and clinical trials have shown that drug-eluting stents (DES) suppress neointimal proliferation (1,2).”
BackgroundResultPathological Analysis of Local Delivery of Paclitaxel Via a Polymer-Coated Stent
Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., Scott, D. S., Froehlich, J., & Virmani, R. (2001) · Circulation · doi:10.1161/hc3001.092037 · Cited by 423 · cited 1×
“Incomplete healing of stent struts may jeopardize the outcome (11).”
BackgroundLate Coronary Occlusion After Intracoronary Brachytherapy
Costa, M. A., Sabaté, M., van der Giessen, W. J., Kay, I. P., Cervinka, P., Ligthart, J. M. R., Serrano, P., Coen, V. L. M. A., Levendag, P. C., & Serruys, P. W. (1999) · Circulation · doi:10.1161/01.cir.100.8.789 · Cited by 389 · cited 1×
“Furthermore, concerns have been raised that such drug-releasing stents, while effective, may (similar to radiation) be prone to sudden thrombotic occlusion (7), delayed restenosis (8), or late malapposition (9).”
BackgroundArterial Paclitaxel Distribution and Deposition
Creel, C. J., Lovich, M. A., & Edelman, E. R. (2000) · Circulation Research · doi:10.1161/01.res.86.8.879 · Cited by 279 · cited 1×
“Antiproliferative taxanes such as paclitaxel are highly lipophilic and bind tightly to cellular tissue (3), resulting in local retention at the site of delivery (4,5).”
BackgroundKolodgie, F. D., John, M. C., Khurana, C. S., Farb, A. A., Wilson, P. S., Acampado, E., Desai, N. P., Soon‐Shiong, P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000032141.31476.15 · Cited by 129
Carrier proteins determine local pharmacokinetics and arterial distribution of paclitaxel
Lovich, M. A., Creel, C., Hong, K., Hwang, C., & Edelman, E. R. (2001) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.1085 · Cited by 123
Determinants of Paclitaxel Uptake, Accumulation and Retention in Solid Tumors
Jang, S. H., Wientjes, M. G., & Au, J. L. ‐. (2001) · Investigational New Drugs · doi:10.1023/a:1010662413174 · Cited by 70
Cited by
Treatment of Coronary In-Stent Restenosis with a Paclitaxel-Coated Balloon Catheter
Scheller, B., Hehrlein, C., Bocksch, W., Rutsch, W., Haghi, D., Dietz, U., Böhm, M., & Speck, U. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061254 · Cited by 816
Self-citationLocal Delivery of Paclitaxel to Inhibit Restenosis during Angioplasty of the Leg
Tepe, G., Zeller, T., Albrecht, T., Heller, S., Schwarzwälder, U., Beregi, J.-P., Claussen, M. D. C. D., Oldenburg, A., Scheller, B., & Speck, U. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706356 · Cited by 803
Self-citationPeripheral arterial calcification: Prevalence, mechanism, detection, and clinical implications
Rocha‐Singh, K. J., Zeller, T., & Jaff, M. R. (2014) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25387 · Cited by 587
Werk, M., Langner, S., Reinkensmeier, B., Boettcher, H.-F., Tepe, G., Dietz, U., Hosten, N., Hamm, B., Speck, U., & Ricke, J. (2008) · Circulation · doi:10.1161/circulationaha.107.735985 · Cited by 511
Self-citationDrug-Coated Balloons for the Prevention of Vascular Restenosis
Gray, W. A., & Granada, J. F. (2010) · Circulation · doi:10.1161/circulationaha.110.936922 · Cited by 209
Metadata
- Authors
- Scheller, B., Speck, U., Schmitt, A., Böhm, M., & Nickenig, G.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2003-10
- Volume
- 42
- Issue
- 8
- Pages
- 1415-1420
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2129461976
- Cited by
- 163
- References
- 12
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.