Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The echocardiographic contrast-enhancing effects and safety profile of ALBUNEX (a suspension of air-filled albumin microspheres) were compared with the new contrast agent OPTISON (formerly FS069: a suspension of albumin microspheres containing the gas perfluoropropane) in 203 patients with inadequate noncontrast echocardiograms. BACKGROUND: The efficacy of ALBUNEX has been limited by its short duration of action. By using perfluoropropane instead of air within the microsphere, its duration of action is increased. METHODS: Each patient received ALBUNEX (0.8 and 0.22 mL/kg) and OPTISON (0.2, 0.5, 3.0, and 5.0 mL) on separate days a minimum of 48 hours apart. Echocardiograms were evaluated for increase in left ventricular (LV) endocardial border length, degree of LV opacification, number of LV endocardial border segments visualized, conversion from a nondiagnostic to a diagnostic echocardiogram, and duration of contrast enhancement. A thorough safety evaluation was conducted. RESULTS: Compared with ALBUNEX, OPTISON more significantly improved every measure of contrast enhancement. OPTISON increased well-visualized LV endocardial border length by 6.0+/-5.1, 6.9+/-5.4, 7.5+/-4.7, and 7.6+/-4.8 cm, respectively, for each of the four doses, compared with only 2.2+/-4.5 and 3.4+/-4.6 cm, respectively, for the two ALBUNEX doses (p < 0.001). 100% LV opacification was achieved in 61%, 73%, 87%, and 87% of the patients with the four doses of OPTISON, but in only 16% and 36% of the patients with the two ALBUNEX doses (p < 0.001). Conversion of nondiagnostic to diagnostic echocardiograms with contrast occurred in 74% of patients with the optimal dose of OPTISON (3.0 mL) compared with only 26% with the optimal dose of ALBUNEX (0.22 mL/kg) (p < 0.001). The duration of contrast effect was also significantly greater with OPTISON than with ALBUNEX. In a subset of patients with potentially poor transpulmonary transit of contrast (patients with chronic lung disease or dilated cardiomyopathy), OPTISON more significantly improved the same measures of contrast enhancement compared with ALBUNEX and did so to the same extent as in the overall population. Side effects were similar and transient with the two agents. CONCLUSION: OPTISON appears to be a safe, well-tolerated echocardiographic contrast agent that is superior to ALBUNEX.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interactions Between Microbubbles and Ultrasound: In Vitro and In Vivo Observations
Wei, K., Skyba, D. M., Firschke, C., Jayaweera, A. R., Lindner, J. R., & Kaul, S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00029-6 · Cited by 282
Myocardial Contrast Echocardiography
Lepper, W., Belcik, T. A., Wei, K. S., Lindner, J. R., Sklenar, J., & Kaul, S. (2004) · Circulation · doi:10.1161/01.cir.0000132613.53542.e9 · Cited by 146
Gény, B., Mettauer, B., Muan, B., Bischoff, P. L., Epailly, É., Piquard, F., Eisenmann, B., & Haberey, P. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90437-6 · Cited by 72
Cited by
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Riess, J. G. (2001) · Chemical Reviews · doi:10.1021/cr970143c · Cited by 773
Schutt, E. G., Klein, D. H., Mattrey, R. M., & Riess, J. G. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200200550 · Cited by 543
Mulvagh, S. L., Rakowski, H., Vannan, M. A., Abdelmoneim, S. S., Becher, H., Bierig, S. M., Burns, P. N., Castello, R., Coon, P. D., Hagen, M. E., et al. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.009 · Cited by 492
Fluorine (19F) MRS and MRI in biomedicine
Ruiz‐Cabello, J., Barnett, B. P., Bottomley, P. A., & Bulte, J. W. M. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1570 · Cited by 489
Ultrasound contrast agents: properties, principles of action, tolerance, and artifacts
Correas, J.-M., Bridal, L., Lesavre, A., Méjean, A., Claudon, M., & Hélénon, O. (2001) · European Radiology · doi:10.1007/s003300100940 · Cited by 435
Microbubble contrast agents: a new era in ultrasound
Blomley, M. J. K., Cooke, J. C., Unger, E. C., Monaghan, M. J., & Cosgrove, D. O. (2001) · BMJ · doi:10.1136/bmj.322.7296.1222 · Cited by 426
Klibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Senior, R., Becher, H., Monaghan, M., Agati, L., Zamorano, J., Vanoverschelde, J. L., & Nihoyannopoulos, P. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep005 · Cited by 359
Diabetic cardiomyopathy: mechanisms, diagnosis and treatment
HAYAT, S. A., PATEL, B., KHATTAR, R. S., & MALIK, R. A. (2004) · Clinical Science · doi:10.1042/cs20040057 · Cited by 352
Contrast Echocardiography: Current and Future Applications
Mulvagh, S. L., DeMaria, A. N., Feinstein, S. B., Burns, P. N., Kaul, S., Miller, J. G., Monaghan, M., Porter, T. R., Shaw, L. J., & Villanueva, F. S. (2000) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2000.105462 · Cited by 310
Fluorous micro- and nanophases with a biomedical perspective
Riess, J. G. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00262-4 · Cited by 289
Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery
Paefgen, V., Doleschel, D., & Kiessling, F. (2015) · Frontiers in Pharmacology · doi:10.3389/fphar.2015.00197 · Cited by 272
Senior, R., Becher, H., Monaghan, M., Agati, L., Zamorano, J., Vanoverschelde, J. L., Nihoyannopoulos, P., Edvardsen, T., Lancellotti, P., Reviewers: This document was reviewed by members of the EACVI Scientific Documents Committee for 2014–16 and 2016–18, et al. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex182 · Cited by 255
Ultrasound Contrast Agent Modeling: A Review
Versluis, M., Stride, E., Lajoinie, G., Dollet, B., & Segers, T. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.04.014 · Cited by 233
“1984) and Optison (Skyba et al. 1996; Cohen et al. 1998)—containing coated microbubbles that were formed by sonication of human serum albumin.”
BackgroundInfluentialPlatts, D. G., Sedgwick, J. F., Burstow, D. J., Mullany, D. V., & Fraser, J. F. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.11.009 · Cited by 201
Klibanov, A. L., Rasche, P. T., Hughes, M. S., Wojdyla, J. K., Galen, K. P., Wible, J. H., & Brandenburger, G. H. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000115926.96796.75 · Cited by 199
“left ventricle opacification and endocardial border delineation.(2) Blood containing a microbubble contrast agent at this”
BackgroundUltrasound-Based Micro-/Nanosystems for Biomedical Applications
Huang, H., Zheng, Y., Chang, M., Song, J., Xia, L., Wu, C., Jia, W., Ren, H., Feng, W., & Chen, Y. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00009 · Cited by 183
Thomson, H. L., Basmadjian, A.-J., Rainbird, A. J., Razavi, M., Avierinos, J.-F., Pellikka, P. A., Bailey, K. R., Breen, J. F., & Enriquez-Sarano, M. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01416-4 · Cited by 178
“injection (32,33) have the potential to improve the accuracy”
BackgroundHeinle, S. K., Noblin, J., Goree-Best, P., Mello, A., Ravad, G., Mull, S., Mammen, P., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.102.1.55 · Cited by 173
Kitzman, D. W., Goldman, M. E., Gillam, L. D., Cohen, J. L., Aurigemma, G. P., & Gottdiener, J. S. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01050-x · Cited by 166
Self-citationXu, J. S., Huang, J., Qin, R., Hinkle, G. H., Povoski, S. P., Martin, E. W., & Xu, R. X. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.052 · Cited by 108
Albumin-binding RNAi Conjugate for Carrier Free Treatment of Arthritis
Colazo, J. M., Hoogenboezem, E. N., Keech, M. C., Francini, N., Shah, V., Yu, F., Lo, J. H., Sorets, A. G., McCune, J. T., Cho, H., et al. (2023) · doi:10.1101/2023.05.31.542971 · Cited by 11
Metadata
- Authors
- Cohen, J. L., Cheirif, J., Segar, D. S., Gillam, L. D., Gottdiener, J. S., Hausnerova, E., & Bruns, D. E.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1998-09
- Volume
- 32
- Issue
- 3
- Pages
- 746-752
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2213500965
- Cited by
- 297
- References
- 3
- FWCI
- 23.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.