Multivariate prediction of in-hospital mortality after percutaneous coronary interventions in 1994–1996
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Using recent data, we sought to identify risk factors associated with in-hospital mortality among patients undergoing percutaneous coronary interventions. BACKGROUND: The ability to accurately predict the risk of an adverse outcome is important in clinical decision making and for risk adjustment when assessing quality of care. Most clinical prediction rules for percutaneous coronary intervention (PCI) were developed using data collected before the broader use of new interventional devices. METHODS: Data were collected on 15,331 consecutive hospital admissions by six clinical centers. Logistic regression analysis was used to predict the risk of in-hospital mortality. RESULTS: Variables associated with an increased risk of in-hospital mortality included older age, congestive heart failure, peripheral or cerebrovascular disease, increased creatinine levels, lowered ejection fraction, treatment of cardiogenic shock, treatment of an acute myocardial infarction, urgent priority, emergent priority, preprocedure insertion of an intraaortic balloon pump and PCI of a type C lesion. The receiver operating characteristic area for the predicted probability of death was 0.88, indicating a good ability to discriminate. The rule was well calibrated, predicting accurately at all levels of risk. Bootstrapping demonstrated that the estimate was stable and performed well among different patient subsets. CONCLUSIONS: In the current era of interventional cardiology, accurate calculation of the risk of in-hospital mortality after a percutaneous coronary intervention is feasible and may be useful for patient counseling and for quality improvement purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 1×
“The area under the receiver operating characteristic (ROC) curve was used as a measure of model discrimination (27,28).”
MethodMeasuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058 · cited 2×
“The area under the receiver operating characteristic (ROC) curve was used as a measure of model discrimination (27,28).”
BackgroundMethodEfron, B., & Tibshirani, R. (1986) · Statistical Science · doi:10.1214/ss/1177013815 · Cited by 6,033 · cited 1×
“The statistical model was internally validated using the technique of bootstrap resampling (29).”
MethodEpidemiologic Research: Principles and Quantitative Methods.
Mayer, L. S., Kleinbaum, D. G., Kupper, L. L., & Morgenstern, H. (1984) · Journal of the American Statistical Association · doi:10.2307/2288427 · Cited by 2,905
Hennekens, C. H., Buring, J. E., & Mayrent, S. L. (1987) · Medical Entomology and Zoology · Cited by 2,319
Ryan, T. J., Faxon, D. P., Gunnar, R. M., Kennedy, J. W., King, S. B., Loop, F. D., Peterson, K. L., Reeves, T. J., Williams, D. O., & Winters, W. L. (1988) · Circulation · doi:10.1161/01.cir.78.2.486 · Cited by 2,123
Self-citation(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-2-316_4 · Cited by 1,926 · cited 1×
“Standard statistical methods were used for the calculation of the odds ratios (OR) with 95% confidence intervals (CI) and p values (22).”
MethodComparison of Coronary Bypass Surgery with Angioplasty in Patients with Multivessel Disease
(1996) · New England Journal of Medicine · doi:10.1056/nejm199607253350401 · Cited by 1,531
TRANSLUMINAL DILATATION OF CORONARY-ARTERY STENOSIS
Grüntzig, A. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90500-7 · Cited by 1,343
Guidelines for percutaneous transluminal coronary angioplasty
Ryan, T. J. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90431-7 · Cited by 1,029
Self-citationAppointment of New Associate Editor for Circulation
Willerson, J. T. (1996) · Circulation · doi:10.1161/01.cir.94.6.1193 · Cited by 954
Orchard, T. J. (1974) · The Lancet · doi:10.1016/s0140-6736(74)92567-7 · Cited by 853
Percutaneous Transluminal Coronary Angioplasty in 1985–1986 and 1977–1981
Detre, K., Holubkov, R., Kelsey, S., Cowley, M., Kent, K., Williams, D., Myler, R., Faxon, D., Holmes, D., Bourassa, M., et al. (1988) · New England Journal of Medicine · doi:10.1056/nejm198802043180501 · Cited by 851
Parisi, A. F., Folland, E. D., & Hartigan, P. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201023260102 · Cited by 736
A Randomized Trial Comparing Coronary Angioplasty with Coronary Bypass Surgery
King, S. B., Lembo, N. J., Weintraub, W. S., Kosinski, A. S., Barnhart, H. X., Kutner, M. H., Alazraki, N. P., Guyton, R. A., & Zhao, X.-Q. (1994) · New England Journal of Medicine · doi:10.1056/nejm199410203311602 · Cited by 734
O'Connor, G. T. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03530350023029 · Cited by 726
Self-citationParticipants, R. T. (1993) · The Lancet · doi:10.1016/0140-6736(93)90348-k · Cited by 598
How Biased is the Apparent Error Rate of a Prediction Rule?
Efron, B. (1986) · Journal of the American Statistical Association · doi:10.1080/01621459.1986.10478291 · Cited by 587 · cited 1×
“This has been shown to be more efficient than split-sample cross validation (35).”
MethodEpidemiologic research—1964–1967
Greene, J. C. (1968) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1968.0207 · Cited by 568
Hamm, C. W., Reimers, J., Ischinger, T., Rupprecht, H.-J., Berger, J., & Bleifeld, W. (1994) · New England Journal of Medicine · doi:10.1056/nejm199410203311601 · Cited by 539
Meta-analysis of randomised trials comparing coronary angioplasty with bypass surgery
Pocock, S. J., Henderson, R. A., Rickards, A. F., Hampton, J. R., King, S. B., Hamm, C. W., Puel, J., Hueb, W., Goy, J.-J., & Rodriguez, A. (1995) · The Lancet · doi:10.1016/s0140-6736(95)92897-9 · Cited by 530
First-year results of CABRI (Coronary Angioplasty versus Bypass Revascularisation Investigation)
Participants, C. T. (1995) · The Lancet · doi:10.1016/s0140-6736(95)92896-0 · Cited by 470
Percutaneous Transluminal Coronary Angioplasty
Landau, C., Lange, R. A., & Hillis, L. D. (1994) · New England Journal of Medicine · doi:10.1056/nejm199404073301407 · Cited by 445
Kelsey, S. F., James, M., Holubkov, A. L., Holubkov, R., Cowley, M. J., & Detre, K. M. (1993) · Circulation · doi:10.1161/01.cir.87.3.720 · Cited by 275
Hampton, J. R., Henderson, R., Julian, D. G., et al. (1993) · PubMed · Cited by 273
Guidelines for percutaneous transluminal coronary angioplasty
Ryan, T. J., Bauman, W. B., Kennedy, J. W., Kereiakes, D. J., King, S. B., McCallister, B. D., Smith, S. C., & Ullyot, D. J. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90794-2 · Cited by 239 · cited 1×
“70% stenosis) native vessels, dominance, number of bypass grafts (distal anastomoses), ejection fraction (EF) and left ventricular enddiastolic pressure (LVEDP); PCI procedure information: location of lesions attempted (using the Coronary Artery Surgery Study map) (20); category of lesion (never before angioplastied,…”
MethodSelf-citationAdvances in Coronary Angioplasty
Bittl, J. A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610243351707 · Cited by 234 · cited 1×
“In more recent years, balloon angioplasty has been joined by many nonballoon devices that have enhanced the technique’s capability, extended its indications and, in some cases, lowered the rates of adverse outcome (3).”
BackgroundJollis, J. G., Peterson, E. D., Nelson, C. L., Stafford, J. A., DeLong, E. R., Muhlbaier, L. H., & Mark, D. B. (1997) · Circulation · doi:10.1161/01.cir.95.11.2485 · Cited by 213
Rodríguez, A. E., Mele, E. F., Peyregne, E., Bullón, F. S., Baliño, N. A. P., Liprandi, M. I. S., & Palacios, I. F. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00592-7 · Cited by 138
Kimmel, S. E., Berlin, J. A., Strom, B. L., & Laskey, W. K. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00294-4 · Cited by 124
Percutaneous transluminal coronary angioplasty in New York State. Risk factors and outcomes
Hannan, E. L. (1992) · JAMA · doi:10.1001/jama.268.21.3092 · Cited by 107
Block, P. C., Peterson, E. D., Krone, R. J., Kesler, K. L., Hannan, E. L., O’Connor, G. T., & Detre, K. M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00208-3 · Cited by 103
Self-citationPredicting the risk of abrupt vessel closure after angioplasty in an individual patient
Tenaglia, A. N., Fortin, D. F., Califf, R. M., Frid, D. J., Nelson, C. L., Gardner, L. H., Miller, M. J., Navetta, F. I., Smith, J. E., Tcheng, J. E., et al. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90862-1 · Cited by 70 · cited 1×
“(40) developed a scoring system for predicting abrupt”
BackgroundHilborne, L. H., Leape, L. L., Kahan, J. P., Park, R. E., KAMBERG, C. J., & Brook, R. H. (1991) · Cited by 58
Coronary angioplasty versus coronary artery bypass surgery.
Walter, P. J., & Mohan, R. (1996) · PubMed · Cited by 56
Mick, M. J., PIEDMONTE, M. R., Arnold, A. M., & Simpfendorfer, C. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90544-4 · Cited by 44 · cited 1×
“(39) analyzed data from 5,000 consecutive patients seen at the Cleveland Clinic between 1980 and 1988.”
BackgroundHarrell, F., Jr. (1996) · doi:10.1002/(sici)1097-0258(19960229)15:4<361::aid-sim168>3.0.co;2-4
Cited by
Contrast Medium-Induced Acute Kidney Injury
Sadat, U., Usman, A., Boyle, J. R., Hayes, P. D., & Solomon, R. J. (2015) · Cardiorenal Medicine · doi:10.1159/000430770 · Cited by 1,285
Moscucci, M. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00485-8 · Cited by 918
Disruptions in surgical flow and their relationship to surgical errors: An exploratory investigation
Wiegmann, D. A., ElBardissi, A. W., Dearani, J. A., Daly, R. C., & Sundt, T. M. (2007) · Surgery · doi:10.1016/j.surg.2007.07.034 · Cited by 598
Contemporary Mortality Risk Prediction for Percutaneous Coronary Intervention
Peterson, E. D., Dai, D., DeLong, E. R., Brennan, J. M., Singh, M., Rao, S. V., Shaw, R. E., Roe, M. T., Ho, K. K. L., Klein, L. W., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.02.005 · Cited by 457
Shaw, R. E., Anderson, H. V., Brindis, R. G., Krone, R. J., Klein, L. W., McKay, C. R., Block, P. C., Shaw, L. J., Hewitt, K., & Weintraub, W. S. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01731-x · Cited by 187
Metadata
- Authors
- O’Connor, G. T., Malenka, D. J., Quinton, H., Robb, J. F., Kellett, M. A., Shubrooks, S., Bradley, W. A., Hearne, M. J., Watkins, M. W., Wennberg, D. E., Hettleman, B., O’Rourke, D. J., McGrath, P. D., Ryan, T., & VerLee, P.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1999-09
- Volume
- 34
- Issue
- 3
- Pages
- 681-691
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2050192520
- Cited by
- 159
- References
- 39
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.