Photorefractive keratectomy: A technique for laser refractive surgery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The excimer laser offers entirely new corneal surgery procedures. In this paper, we describe conditions for one such procedure, photorefractive keratectomy, the direct reshaping of the cornea's central optical zone using tissue ablation with far ultraviolet radiation. We present equations for the required tissue ablation to achieve required refractive corrections. Conditions for beam uniformity are presented and a method of achieving better beam uniformity using beam integration by rotation is demonstrated. The healing of rabbit corneas after area ablation was observed. Five days after treatment, the surface quality of deep cuts was very irregular; the shallow cuts produced more regular results, as predicted by our calculations of beam characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Excimer Laser Surgery of the Cornea
Trokel, S. L., Srinivasan, R., & Braren, B. (1983) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71911-7 · Cited by 990
MAURICE, D. M. (1962) · Vegetative Physiology and Biochemistry · doi:10.1016/b978-1-4832-3090-0.50013-7 · Cited by 436
An Ultrastructural Study of Corneal Incisions Induced by an Excimer Laser at 193 nm
Marshall, J., Trokel, S., Rothery, S., & Schubert, H. (1985) · Ophthalmology · doi:10.1016/s0161-6420(85)33961-1 · Cited by 277
Self-citation
Cited by
Wound Healing After Excimer Laser Keratomileusis (Photorefractive Keratectomy) in Monkeys
Fantes, F. E. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070070051034 · Cited by 747
Biomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510
Er:YAG laser ablation of tissue: Effect of pulse duration and tissue type on thermal damage
Walsh, J. T., Flotte, T. J., & Deutsch, T. F. (1989) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900090403 · Cited by 478
Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy
Sugar, A., Rapuano, C. J., Culbertson, W. W., Huang, D., Varley, G. A., Agapitos, P. J., de Luise, V. P., & Koch, D. D. (2002) · Ophthalmology · doi:10.1016/s0161-6420(01)00966-6 · Cited by 408
Kim, T.-I., Alió del Barrio, J. L., Wilkins, M., Cochener, B., & Ang, M. (2019) · The Lancet · doi:10.1016/s0140-6736(18)33209-4 · Cited by 373
The Cornea is Not a Piece of Plastic
Roberts, C. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000701-03 · Cited by 326
Møller-Pedersen, T., Cavanagh, H. D., Petroll, W. M., & Jester, J. V. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00142-1 · Cited by 303
Ocular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Mrochen, M., Kaemmerer, M., Mierdel, P., & Seiler, T. (2001) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(00)00806-3 · Cited by 280
Long-term Healing of the Central Cornea after Photorefractive Keratectomy Using an Excimer Laser
Marshall, J., Trokel, S. L., Rothery, S., & Krueger, R. R. (1988) · Ophthalmology · doi:10.1016/s0161-6420(88)32997-0 · Cited by 278
Self-citationEffect of Acute Biomechanical Changes on Corneal Curvature After Photokeratectomy
Dupps, W. J., & Roberts, C. (2001) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20011101-05 · Cited by 212
Thermal and Biomechanical Parameters of Porcine Cornea
Kampmeier, J., Radt, B., Birngruber, R., & Brinkmann, R. (2000) · Cornea · doi:10.1097/00003226-200005000-00020 · Cited by 210
Møller-Pedersen, T., Vogel, M., Li, H. F., Petroll, W. M., Cavanagh, H. D., & Jester, J. V. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30307-8 · Cited by 209
Vincent, S. J., Cho, P., Chan, K. Y., Fadel, D., Ghorbani-Mojarrad, N., González-Méijome, J. M., Johnson, L., Kang, P., Michaud, L., Simard, P., et al. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.003 · Cited by 202
Excimer Laser Ablation Rate and Corneal Hydration
Dougherty, P. J., Wellish, K. L., & Maloney, R. K. (1994) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)72896-x · Cited by 201
Wavefront Ablation Profiles in Refractive Surgery: Description, Results, and Limitations
Smadja, D., Reggiani-Mello, G., Santhiago, M. R., & Krueger, R. R. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20120217-01 · Cited by 58
Metadata
- Authors
- Munnerlyn, C. R., Koons, S. J., & Marshall, J.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 1988-01
- Volume
- 14
- Issue
- 1
- Pages
- 46-52
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2048392529
- Cited by
- 763
- References
- 3
- FWCI
- 12.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.