Modeling the thermal behavior of a surface-micromachined linear-displacement thermomechanical microactuator
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of multiphysics actuators using topology optimization – Part I: One-material structures
Sigmund, O. (2001) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(01)00251-1 · Cited by 613 · cited 2×
“Topology optimization techniques have been applied to the design of electrothermal microactuators by Sigmund [8] and Jonsmann et al. [9].”
MethodBent-beam electrothermal actuators-Part I: Single beam and cascaded devices
Que, L., Park, J.-S., & Gianchandani, Y. B. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.925771 · Cited by 348
Analysis and design of polysilicon thermal flexure actuator
Huang, Q.-A., & Lee, N. K. S. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/1/308 · Cited by 334 · cited 1×
“Ignoring radiation and free convection, the following expression results [17]”
BackgroundThermo-magnetic metal flexure actuators
Guckel, H., Klein, J., Christenson, T., Skrobis, K., Laudon, M., & Lovell, E. G. (2003) · Technical Digest IEEE Solid-State Sensor and Actuator Workshop · doi:10.1109/solsen.1992.228273 · Cited by 212 · cited 1×
“[2] who developed a metal flexure actuator using the SLIGA process.”
MethodTai, Y. C., Mastrangelo, C. H., & Muller, R. S. (1988) · Journal of Applied Physics · doi:10.1063/1.339924 · Cited by 137 · cited 2×
“This expression varies over the range for which it was measured (293K to 800K) from 72 W/m/K to 32 W/m/K. Expressions for kp and kair are tabulated in the Appendix.”
MethodThermal microactuators for surface-micromachining processes
Comtois, J. H., Bright, V. M., & Phipps, M. W. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.221154 · Cited by 109
Thermal Bubble Formation on Polysilicon Micro Resistors
Lin, L., Pisano, A. P., & Carey, V. P. (1998) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2824343 · Cited by 87
Thermal assembly of polysilicon microstructures
Fedder, G. K., & Howe, R. T. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1991.114770 · Cited by 59 · cited 1×
“For the leg lengths considered here, this approximation is reasonable; however, for legs with very short lengths, significant heating at the bond pads can occur, and its effect on the boundary condition should be considered [16].”
Background
Cited by
Micro-Raman thermometry of thermal flexure actuators
Serrano, J. R., Phinney, L. M., & Kearney, S. P. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/7/004 · Cited by 38
Metadata
- Authors
- Lott, C. D., McLain, T. W., Harb, J. N., & Howell, L. L.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2002-09
- Volume
- 101
- Issue
- 1-2
- Pages
- 239-250
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2081943400
- Cited by
- 198
- References
- 8
- FWCI
- 11.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.