A systematic study of the fragmentation pattern of phosphopeptides in an electrospray (ESI) ion trap mass spectrometer is presented. We show that phosphotyrosine- and phosphothreonine-containing peptides show complicated fragmentation patterns. These phosphopeptides were observed to lose the phosphate moiety in the form of H3PO4 and/or HPO3, but were also detected with no loss of the phosphate group. The tendency to lose the phosphate moiety depends strongly on the charge state. Thus, the highest observed charge state tends to retain the phosphate moiety with extensive fragmentation along the peptide backbone. We also show that phosphoserine-containing peptides have relatively simple fragmentation patterns of losing H3PO4. This loss is independent of the charge state. We suggest strategies for the accurate identification of phosphorylation sites using the ion trap mass spectrometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Contributions of mass spectrometry to peptide and protein structure
Biemann, K. (1988) · Biological Mass Spectrometry · doi:10.1002/bms.1200160119 · Cited by 1,015
Phosphopeptide Analysis by Matrix-Assisted Laser Desorption Time-of-Flight Mass Spectrometry
Annan, R. S., & Carr, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac960221g · Cited by 310
Selective Detection and Sequencing of Phosphopeptides at the Femtomole Level by Mass Spectrometry
Carr, S. A., Huddleston, M. J., & Annan, R. S. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0313 · Cited by 305
Huddleston, M. J., Annan, R. S., Bean, M. F., & Carr, S. A. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)80049-5 · Cited by 242
Qin, J., & Chait, B. T. (1997) · Analytical Chemistry · doi:10.1021/ac970489n · Cited by 166
Self-citationIdentification of Phosphorylation Sites in Proteins Separated by Polyacrylamide Gel Electrophoresis
Zhang, X., Herring, C. J., Romano, P. R., Szczepanowska, J., Brzeska, H., Hinnebusch, A. G., & Qin, J. (1998) · Analytical Chemistry · doi:10.1021/ac971207m · Cited by 162
Self-citationLee, S., Kim, H. S., & Beauchamp, J. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973467r · Cited by 144
Liao, P., Leykam, J. F., Andrews, P., Gage, D. A., & Allison, J. (1994) · Analytical Biochemistry · doi:10.1006/abio.1994.1224 · Cited by 140
Ding, J., Burkhart, W., & Kassel, D. B. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290080118 · Cited by 70
Cited by
Beausoleil, S. A., Villén, J., Gerber, S. A., Rush, J., & Gygi, S. P. (2006) · Nature Biotechnology · doi:10.1038/nbt1240 · Cited by 1,577
“For example, phosphopeptide Sequest XCorr scores are often suppressed and score similarities are often observed when sequencing phosphopeptides by tandem mass spectrometr”
BackgroundProtein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Immobilized Gallium(III) Affinity Chromatography of Phosphopeptides
Posewitz, M. C., & Tempst, P. (1999) · Analytical Chemistry · doi:10.1021/ac981409y · Cited by 832
The first identification of lysine malonylation substrates and its regulatory enzyme
Peng, C., Lu, Z., Xie, Z., Cheng, Z., Chen, Y., Tan, M., Luo, H., Zhang, Y., He, W., Yang, K., et al. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.012658 · Cited by 751
“For example, a phosphopeptide bearing a phosphorylation site in either a serine or threonine residue tends to lose the phosphate group, leading to a –98 Da satellite peak in MS/MS spectra (14, 15).”
BackgroundSchug, K. A., & Lindner, W. (2005) · Chemical Reviews · doi:10.1021/cr040603j · Cited by 579
InsPecT: Identification of Posttranslationally Modified Peptides from Tandem Mass Spectra
Tanner, S., Shu, H., Frank, A., Wang, L.-C., Zandi, E., Mumby, M., Pevzner, P. A., & Bafna, V. (2005) · Analytical Chemistry · doi:10.1021/ac050102d · Cited by 567
Phosphoproteome Analysis of Capacitated Human Sperm
Ficarro, S., Chertihin, O., Westbrook, V. A., White, F., Jayes, F., Kalab, P., Marto, J. A., Shabanowitz, J., Herr, J. C., Hunt, D. F., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m202325200 · Cited by 480
Analysis of phosphorylated proteins and peptides by mass spectrometry
McLachlin, D. T., & Chait, B. T. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00250-7 · Cited by 382
Schroeder, M. J., Shabanowitz, J., Schwartz, J. C., Hunt, D. F., & Coon, J. J. (2004) · Analytical Chemistry · doi:10.1021/ac0497104 · Cited by 376
Swaney, D. L., McAlister, G. C., Wirtala, M., Schwartz, J. C., Syka, J. E. P., & Coon, J. J. (2007) · Analytical Chemistry · doi:10.1021/ac061457f · Cited by 363
Phosphopeptide fragmentation and analysis by mass spectrometry
Boersema, P. J., Mohammed, S., & Heck, A. J. R. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1599 · Cited by 362
Androgen Receptor Phosphorylation
Gioeli, D., Ficarro, S. B., Kwiek, J. J., Aaronson, D., Hancock, M., Catling, A. D., White, F. M., Christian, R. E., Settlage, R. E., Shabanowitz, J., et al. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m204131200 · Cited by 351
Phosphoproteomic Analysis of the Developing Mouse Brain
Ballif, B. A., Villén, J., Beausoleil, S. A., Schwartz, D., & Gygi, S. P. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400085-mcp200 · Cited by 346
Horman, S., Vertommen, D., Heath, R., Neumann, D., Mouton, V., Woods, A., Schlattner, U., Wallimann, T., Carling, D., Hue, L., et al. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m506850200 · Cited by 344
OLAV: Towards high‐throughput tandem mass spectrometry data identification
Colinge, J., Masselot, A., Giron, M., Dessingy, T., & Magnin, J. (2003) · PROTEOMICS · doi:10.1002/pmic.200300485 · Cited by 297
Kollewe, C., Mackensen, A.-C., Neumann, D., Knop, J., Cao, P., Li, S., Wesche, H., & Martin, M. U. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m309251200 · Cited by 265
Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics
Haas, W., Faherty, B. K., Gerber, S. A., Elias, J. E., Beausoleil, S. A., Bakalarski, C. E., Li, X., Villén, J., & Gygi, S. P. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500339-mcp200 · Cited by 261
A Fluorescent Sensor for Dual‐Channel Discrimination between Phosgene and a Nerve‐Gas Mimic
Zhou, X., Zeng, Y., Liyan, C., Wu, X., & Yoon, J. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201601346 · Cited by 252
Zarling, A. L., Ficarro, S. B., White, F. M., Shabanowitz, J., Hunt, D. F., & Engelhard, V. H. (2000) · The Journal of Experimental Medicine · doi:10.1084/jem.192.12.1755 · Cited by 213
“Liquid Chromatography/MS/MS Parameters on the LCQ Ion Trap Mass Spectrometer.”
BackgroundInfluentialPhosphoproteomic Analysis of Synaptosomes from Human Cerebral Cortex
DeGiorgis, J. A., Jaffe, H., Moreira, J. E., Carlotti, C. G., Leite, J. P., Pant, H. C., & Dosemeci, A. (2005) · Journal of Proteome Research · doi:10.1021/pr0498436 · Cited by 56
Metadata
- Authors
- DeGnore, J. P., & Qin, J.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-11-01
- Volume
- 9
- Issue
- 11
- Pages
- 1175-1188
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2002609852
- Cited by
- 257
- References
- 14
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.