Automated mass spectrometry imaging with a matrix-assisted laser desorption ionization time-of-flight instrument
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The automated use of a matrix-assisted laser desorption ionization (MALDI) mass spectrometer (MS) is described for image analysis of samples through implementation of new software for instrument control, data acquisition, and data analysis. The software permits automated acquisition of MS MALDI spectra to form an ordered data array and contains display features to provide images at one or more mass-to-charge ratio values. The technique can be used to scan tissue samples, blotted samples, gels, or other sample surfaces where the image analysis of that sample is required. The program achieves a time of typically 1 s per image point, permitting an analysis made up of large numbers of points with high spatial resolution up to 850 dpi. The features of the software are demonstrated in this paper with samples of printed images, where visible images can be compared to those obtained by mass spectrometry. Quantitative aspects are introduced by analyzing a series of sample spots containing different amounts of several proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1994) · Vacuum · doi:10.1016/0042-207x(94)90087-6 · Cited by 3,332
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234 · cited 5×
“In order to estimate the quantitative aspects of the technique, several different concentrations of vasopressin were microspotted on a C-18 surface [ 12 ] and analyzed with the Image Tool.”
BackgroundMethodSelf-citationAtomic and Molecular Imaging at the Single-Cell Level with TOF-SIMS
Colliver, T. L., Brummel, C. L., Pacholski, M. L., Swanek, F. D., Ewing, A. G., & Winograd, N. (1997) · Analytical Chemistry · doi:10.1021/ac9701748 · Cited by 260 · cited 1×
“maging of the surface of samples by mass spectrometry has been demonstrated using secondary ion mass spectrometry (SIMS) [1–3] where investigators have analyzed tissue samples for low molecular weight compounds [ 4 , 5]. Experiments involving work with laser microprobe mass spectrometry (LMMS), also named laser microp…”
BackgroundStahl, B., Linos, A., Karas, M., Hillenkamp, F., & Steup, M. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2011 · Cited by 100 · cited 1×
“Such software would also be of wide interest, allowing the imaging capability to be added to already existing MALDI instrumental procedures [14, 15 ].”
BackgroundOrganic and inorganic analysis with laser microprobe mass spectrometry. Part II: Applications
Vaeck, L. V., Struyf, H., Roy, W. V., & Adams, F. C. (1994) · Mass Spectrometry Reviews · doi:10.1002/mas.1280130303 · Cited by 54 · cited 1×
“... using secondary ion mass spectrometry (SIMS) [1–3] where investigators have analyzed tissue samples for low molecular weight compounds [4, 5]. Experiments involving work with laser microprobe mass spectrometry (LMMS), also named laser microprobe mass analysis (LAMMA), have used a well-focused laser beam for the de…”
MethodCharacterization of Acetaminophen: Molecular Microanalysis with Raman Microprobe Spectroscopy
Pestaner, J. P., Mullick, F., & Centeno, J. (1996) · Journal of Forensic Sciences · doi:10.1520/jfs14050j · Cited by 31
The application of laser microprobe mass analysis to the study of biological material
Iancu, T. C., Perl, D., Sternlieb, I., Lerner, A., Leshinsky‐Silver, E., Kolodny, E. H., Hsu, A. P., & Good, P. F. (1996) · BioMetals · doi:10.1007/bf00188091 · Cited by 27
Cited by
Stoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
Self-citationMcDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Direct Molecular Analysis of Whole-Body Animal Tissue Sections by Imaging MALDI Mass Spectrometry
Khatib-Shahidi, S., Andersson, M., Herman, J. L., Gillespie, T. A., & Caprioli, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac060788p · Cited by 505
Self-citationReyzer, M. L., Hsieh, Y., Ng, K., Korfmacher, W. A., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.525 · Cited by 371
Self-citationIntegrating Histology and Imaging Mass Spectrometry
Chaurand, P., Schwartz, S. A., Billheimer, D., Xu, B. J., Crecelius, A., & Caprioli, R. M. (2004) · Analytical Chemistry · doi:10.1021/ac0351264 · Cited by 365
Self-citation
Metadata
- Authors
- Stoeckli, M., Farmer, T. B., & Caprioli, R. M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-01-01
- Volume
- 10
- Issue
- 1
- Pages
- 67-71
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2016657862
- Cited by
- 201
- References
- 7
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.