Nanoelectrospray—More than just a minimized-flow electrospray ionization source
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The comparison between electrospray ionization (ESI) mass spectra from NaCl solutions with and without analyte obtained under ionspray and nanospray conditions reveals different mass spectral behavior of the two ESI techniques. This can be attributed to the different initial droplet sizes which are in the microns range for ionspray, while in nanospray they are believed to be about one order of magnitude smaller. In the context of the widely accepted uneven-fission model, nanospray would then enter one fission generation later; in addition, a higher initial droplet surface charge density in nanospray results in early fissions without extensive evaporation and thus increase in sample and salt concentration. This rationalizes that ionspray spectra closely resemble nanospray spectra from solutions with about one order of magnitude higher salt concentrations, showing a higher tolerance of nanospray towards salt contamination. When the analyte is a peptide (in a solution containing a high molar surplus of salt), molecule ion formation effectively competes with salt cluster ion formation; when the analyte is a sugar, it is detectable beside a high salt concentration only with nanospray, indicating the supporting effect of surface activity on ion release in the case of peptides. A model is presented which explains the different mass spectral behaviour of ionspray and nanospray by suggesting different "predominant fission pathways" depending on the size of the initial droplets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Alkali halide clusters and microcrystals
Martin, T. P. (1983) · Physics Reports · doi:10.1016/0370-1573(83)90024-8 · Cited by 368
Electrospray-ion spray: a comparison of mechanisms and performance
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00018a017 · Cited by 322
Of protons or proteins: “A beam's a beam for a' that.” (O.S. Burns)
Meng, C. K., Mann, M., & Fenn, J. B. (1988) · Zeitschrift für Physik D Atoms, Molecules and Clusters · doi:10.1007/bf01384871 · Cited by 254
Electrospray mass spectrometry of poly(ethylene glycols) with molecular weights up to five million
Nohmi, T., & Fenn, J. B. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00035a012 · Cited by 217
The effect of charge emission from electrified liquid cones
De La Mora, J. F. (1992) · Journal of Fluid Mechanics · doi:10.1017/s0022112092002829 · Cited by 212
Desolvation of ions and molecules in thermospray mass spectrometry
Schmelzeisen-Redeker, G., Bütfering, L., & Röllgen, F. W. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85004-9 · Cited by 163
Bahr, U., Pfenninger, A., Karas, M., & Stahl, B. (1997) · Analytical Chemistry · doi:10.1021/ac970624w · Cited by 157
Self-citationAre the electrospray mass spectra of proteins related to their aqueous solution chemistry?
Guevremont, R., Siu, K. W. M., Blanc, J. C. Y. L., & Berman, S. S. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87005-j · Cited by 134
Winger, B. E., Light‐Wahl, K. J., Loo, R. R. O., Udseth, H. R., & Smith, R. D. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85015-p · Cited by 120
Wang, G., & Cole, R. B. (1994) · Analytical Chemistry · doi:10.1021/ac00093a026 · Cited by 109
Cited by
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Self-citationProtein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Metadata
- Authors
- Juraschek, R., Dülcks, T., & Karas, M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-04-01
- Volume
- 10
- Issue
- 4
- Pages
- 300-308
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1995070541
- Cited by
- 415
- References
- 18
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.