Automated reduction and interpretation of
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Here a fully automated computer algorithm is applied to complex mass spectra of peptides and proteins. This method uses a subtractive peak finding routine to locate possible isotopic clusters in the spectrum, subjecting these to a combination of the previous Fourier transform/Patterson method for primary charge determination and the method for least-squares fitting to a theoretically derived isotopic abundance distribution for m/z determination of the most abundant isotopic peak, and the statistical reliability of this determination. If a predicted protein sequence is available, each such m/z value is checked for assignment as a sequence fragment. A new signal-to-noise calculation procedure has been devised for accurate determination of baseline and noise width for spectra with high peak density. In 2 h, the program identified 824 isotopic clusters representing 581 mass values in the spectrum of a GluC digest of a 191 kDa protein; this is >50% more than the number of mass values found by the extremely tedious operator-applied methodology used previously. The program should be generally applicable to classes of large molecules, including DNA and polymers. Thorough high resolution analysis of spectra by Horn (THRASH) is proposed as the program's verb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Thorough High-Resolution Analysis of Spectra by Horn (THRASH) was the first software to automate the deconvolution of high-resolution mass spectra and is still widely used [124].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [124]
In the citing paper
“Currently, the software incorporates various deconvolution algorithms including MS-Deconv,17 TopFD,14 eTHRASH,19 pParseTD,15 and ProMex26 for both MS and MS/MS deconvolution.”
From MASH Explorer: A Universal Software Environment for Top-Down Proteomics (2020) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Complete Genome Sequence of Escherichia coli K-12
Blattner, F. R., Plunkett, G., Bloch, C. A., Perna, N. T., Burland, V., Riley, M., Collado-Vides, J., Glasner, J. D., Rode, C. K., Mayhew, G. F., et al. (1997) · Science · doi:10.1126/science.277.5331.1453 · Cited by 7,452
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationElectrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14440 · Cited by 1,427
Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
Self-citationTailored excitation for Fourier transform ion cyclotron mass spectrometry
Marshall, A. G., Wang, T. C. L., & Ricca, T. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00312a015 · Cited by 631
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605
Self-citationInterpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Research works printed but not linked: 2
- P A Jansson, Ed, 1984AcademicNew York
- J J Drader, S D Shi, .-H Freitas, M A Hendrickson, C L Marshall, Proceedings of the 46th ASMS Conference on Mass Spectrometry and Allied Topics. the 46th ASMS Conference on Mass Spectrometry and Allied Topics
Cited by
Items 201–300 of 555
Tipton, J. D., Tran, J. C., Catherman, A. D., Ahlf, D. R., Durbin, K. R., Lee, J. E., Kellie, J. F., Kelleher, N. L., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac202651v · Cited by 40
Mass Spectrometry Data Analysis in the Proteomics Era
Forner, F., Foster, L. J., & Toppo, S. (2007) · Current Bioinformatics · doi:10.2174/157489307779314285 · Cited by 41
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Top‐down tandem mass spectrometry on RN ase A and B using a Qh/FT‐ICR hybrid mass spectrometer
Bourgoin‐Voillard, S., Leymarie, N., & Costello, C. E. (2014) · PROTEOMICS · doi:10.1002/pmic.201300433 · Cited by 39
Detection of four oxidation sites in viral prolyl‐4‐hydroxylase by top‐down mass spectrometry
Ge, Y., Lawhorn, B. G., ElNaggar, M., Sze, S. K., Begley, T. P., & McLafferty, F. W. (2003) · Protein Science · doi:10.1110/ps.03244403 · Cited by 39
Self-citationShen, Y., Tolić, N., Hixson, K. K., Purvine, S. O., Anderson, G., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac801123p · Cited by 39
Eliuk, S. M., Maltby, D. A., Panning, B., & Burlingame, A. L. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900569-mcp200 · Cited by 41
Sacksteder, C. A., Whittier, J. E., Xiong, Y., Li, J., Galeva, N. A., Jacoby, M. E., Purvine, S. O., Williams, T. D., Rechsteiner, M., Bigelow, D. J., et al. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.086033 · Cited by 39
Automated imaging and identification of proteoforms directly from ovarian cancer tissue
McGee, J. P., Su, P., Durbin, K. R., Hollas, M. A. R., Bateman, N. W., Maxwell, G. L., Conrads, T. P., Fellers, R. T., Melani, R. D., Camarillo, J. M., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-42208-3 · Cited by 39
A Universal Score for Deconvolution of Intact Protein and Native Electrospray Mass Spectra
Marty, M. T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05272 · Cited by 38
A perspective view of top‐down proteomics in snake venom research
Ghezellou, P., Garikapati, V., Kazemi, S. M., Strupat, K., Ghassempour, A., & Spengler, B. (2018) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8255 · Cited by 38
Ibrahim, Y., Prior, D. C., Baker, E. S., Smith, R. D., & Belov, M. E. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.03.009 · Cited by 38
Cannon, J. R., Kluwe, C., Ellington, A. D., & Brodbelt, J. S. (2014) · PROTEOMICS · doi:10.1002/pmic.201300364 · Cited by 38
Tabb, D. L., Shah, M. B., Strader, M. B., Connelly, H. M., Hettich, R. L., & Hurst, G. B. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.02.003 · Cited by 38
Petyuk, V. A., Qian, W.-J., Smith, R. D., & Smith, D. J. (2010) · Methods · doi:10.1016/j.ymeth.2009.07.009 · Cited by 37
Ansong, C. K., Tolić, N., Purvine, S. O., Porwollik, S., Jones, M. B., Yoon, H., Payne, S., Martin, J. L., Burnet, M., Monroe, M. E., et al. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-433 · Cited by 37
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Springer eBooks · doi:10.1007/978-3-642-36303-0_7 · Cited by 37
Palmblad, M., Wetterhall, M., Markides, K. E., Håkansson, P., & Bergquist, J. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000630)14:12<1029::aid-rcm984>3.0.co;2-# · Cited by 37
Comprehensive analysis of tropomyosin isoforms in skeletal muscles by top-down proteomics
Jin, Y., Peng, Y., Lin, Z., Chen, Y.-C., Wei, L., Hacker, T. A., Larsson, L., & Ge, Y. (2016) · Journal of Muscle Research and Cell Motility · doi:10.1007/s10974-016-9443-7 · Cited by 36
Park, K., Yoon, J. Y., Lee, S., Paek, E., Park, H., Jung, H.-J., & Lee, S.-W. (2008) · Analytical Chemistry · doi:10.1021/ac800913b · Cited by 36
Manes, N. P., Dong, L., Zhou, W., Du, X., Reghu, N., Kool, A. C., Choi, D., Bailey, C. L., Petricoin, E. F., Liotta, L. A., et al. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.000927 · Cited by 36
Kanawati, B., Bader, T., Wanczek, K. P., Li, Y., & Schmitt‐Kopplin, P. (2017) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7940 · Cited by 36
The isotope distribution: A rose with thorns
Claesen, J., Rockwood, A. L., Gorshkov, M. V., & Valkenborg, D. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21820 · Cited by 36
PIPI: PTM-Invariant Peptide Identification Using Coding Method
Yu, F., Li, N., & Yu, W. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00485 · Cited by 36
Improved model-based, platform-independent feature extraction for mass spectrometry
Noy, K., & Fasulo, D. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm385 · Cited by 36
Chen, Y., Hoover, M. E., Dang, X., Shomo, A. A., Guan, X., Marshall, A. G., Freitas, M. A., & Young, N. L. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.046441 · Cited by 35
Khatri, K., Klein, J., & Zaia, J. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9970-5 · Cited by 35
Qi, Y., Li, H., Wills, R. H., Perez‐Hurtado, P., Yu, X., Kilgour, D. P. A., Barrow, M. P., Lin, C., & O’Connor, P. B. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0600-6 · Cited by 35
An algorithm for baseline correction of MALDI mass spectra
Williams, B., Cornett, S., Dawant, B. M., Crecelius, A. C., Bodenheimer, B., & Caprioli, R. M. (2005) · ACM Southeast Regional Conference (ACMSE) · doi:10.1145/1167350.1167394 · Cited by 35
A Fast and Accurate Algorithm for the Quantification of Peptides from Mass Spectrometry Data
Schulz-Trieglaff, O. B., Hussong, R., Gröpl, C., Hildebrandt, A., & Reinert, K. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-71681-5_33 · Cited by 34
Slawski, M., Hussong, R., Tholey, A., Jakoby, T., Gregorius, B., Hildebrandt, A., & Hein, M. (2012) · BMC Bioinformatics · doi:10.1186/1471-2105-13-291 · Cited by 34
Versatile Online−Offline Engine for Automated Acquisition of High-Resolution Tandem Mass Spectra
Wenger, C. D., Boyne, M. T., Ferguson, J. T., Robinson, D. E., & Kelleher, N. L. (2008) · Analytical Chemistry · doi:10.1021/ac8010704 · Cited by 33
Identification of Phosphorylation Sites on the Yeast Ribonucleotide Reductase Inhibitor Sml1
Uchiki, T., Dice, L. T., Hettich, R. L., & Dealwis, C. G. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m309751200 · Cited by 33
Shliaha, P. V., Gibb, S., Gorshkov, V., Jespersen, M. S., Andersen, G. R., Bailey, D. J., Schwartz, J. H., Eliuk, S. M., Schwämmle, V., & Jensen, O. N. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02344 · Cited by 33
Dissimilarity in the Reductive Unfolding Pathways of Two Ribonuclease Homologues
Narayan, M., Xu, G., Ripoll, D. R., Zhai, H., Breuker, K., Wanjalla, C., Leung, H. J., Navon, A., Welker, E., McLafferty, F. W., et al. (2004) · Journal of Molecular Biology · doi:10.1016/j.jmb.2004.03.014 · Cited by 33
Self-citationMcLoughlin, S. M., & Kelleher, N. L. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0470867 · Cited by 33
Bioinformatics in mass spectrometry data analysis for proteomics studies
Cristoni, S., & Bernardi, L. R. (2004) · Expert Review of Proteomics · doi:10.1586/14789450.1.4.469 · Cited by 33
Titulaer, M. K., Siccama, I., Dekker, L. J. M., van Rijswijk, A. L., Heeren, R. M. A., Smitt, P. A. E. S., & Luider, T. M. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-403 · Cited by 33
Oh, H. B., & McLafferty, F. W. (2006) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2006.27.3.389 · Cited by 32
Self-citationOccurrence and Detection of Phosphopeptide Isomers in Large-Scale Phosphoproteomics Experiments
Courcelles, M., Bridon, G., Lemieux, S., & Thibault, P. (2012) · Journal of Proteome Research · doi:10.1021/pr300229m · Cited by 32
Noise analysis for 2D tandem Fourier transform ion cyclotron resonance mass spectrometry
van der Rest, G., & Marshall, A. G. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00396-7 · Cited by 32
Mapping protein structural changes by quantitative cross-linking
Kukačka, Z., Rosůlek, M., Strohalm, M., Kavan, D., & Novák, P. (2015) · Methods · doi:10.1016/j.ymeth.2015.05.027 · Cited by 32
Shotgun Protein Identification and Quantification by Mass Spectrometry
Lu, B., Xu, T., Park, S. K., & Yates, J. R. (2009) · Methods in molecular biology · doi:10.1007/978-1-60761-157-8_15 · Cited by 32
Next-Generation Serology by Mass Spectrometry: Readout of the SARS-CoV-2 Antibody Repertoire
Melani, R. D., Soye, B. J. D., Kafader, J. O., Forte, E., Hollas, M. A. R., Blagojevic, V., Negrão, F., McGee, J. P., Drown, B., Lloyd-Jones, C., et al. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00882 · Cited by 32
Patel, M. K., Vijayakrishnan, B., Koeppe, J. R., Chalker, J. M., Doores, K. J., & Davis, B. G. (2010) · Chemical Communications · doi:10.1039/c0cc03420g · Cited by 32
Effective Top-Down LC/MS+ Method for Assessing Actin Isoforms as a Potential Cardiac Disease Marker
Chen, Y.-C., Ayaz-Guner, S., Peng, Y., Lane, N. M., Locher, M. R., Kohmoto, T., Larsson, L., Moss, R. L., & Ge, Y. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01745 · Cited by 31
Zhang, L., & Freitas, M. A. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.02.012 · Cited by 31
Analytical strategies for the global quantification of intact proteins
Collier, T. S., & Muddiman, D. C. (2012) · Amino Acids · doi:10.1007/s00726-012-1285-z · Cited by 31
Chen, J., Shiyanov, P. A., Zhang, L., Schlager, J. J., & Green‐Church, K. B. (2010) · Analytical Chemistry · doi:10.1021/ac1006766 · Cited by 31
MultiAlign: a multiple LC-MS analysis tool for targeted omics analysis
Lamarche, B. L., Crowell, K. L., Jaitly, N., Petyuk, V., Shah, A. R., Polpitiya, A. D., Sandoval, J. D., Kiebel, G. R., Monroe, M. E., Callister, S., et al. (2013) · BMC Bioinformatics · doi:10.1186/1471-2105-14-49 · Cited by 31
Zaia, J., Khatri, K., Klein, J., Chun, S., Sheng, Y., & Viner, R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03081 · Cited by 31
Uncovering hidden protein modifications with native top-down mass spectrometry
Bennett, J. L., El‐Baba, T. J., Zouboulis, K., Kirschbaum, C., Song, H., Butroid, F. I., Benesch, J. L. P., Lutomski, C. A., & Robinson, C. V. (2025) · Nature Methods · doi:10.1038/s41592-025-02846-5 · Cited by 30
Du, Y., Meng, F., Patrie, S. M., Miller, L. M., & Kelleher, N. L. (2004) · Journal of Proteome Research · doi:10.1021/pr0499489 · Cited by 30
Autopiquer - a Robust and Reliable Peak Detection Algorithm for Mass Spectrometry
Kilgour, D. P. A., Hughes, S., Kilgour, S. L., Mackay, C. L., Palmblad, M., Tran, B. Q., Goo, Y. A., Ernst, R. K., Clarke, D. J., & Goodlett, D. R. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1549-z · Cited by 30
Ion annotation-assisted analysis of LC-MS based metabolomic experiment
Varghese, R. S., Zhou, B., Ranjbar, M., Zhao, Y., & Ressom, H. W. (2012) · Proteome Science · doi:10.1186/1477-5956-10-s1-s8 · Cited by 30
Ribosomal Proteins of Deinococcus radiodurans: Their Solvent Accessibility and Reactivity
Running, W. E., & Reilly, J. P. (2009) · Journal of Proteome Research · doi:10.1021/pr800544y · Cited by 29
Feature extraction in the analysis of proteomic mass spectra
Wang, X., Zhu, W., Pradhan, K., Ji, C., Ma, Y., Semmes, O. J., Glimm, J. G., & Mitchell, J. S. B. (2006) · PROTEOMICS · doi:10.1002/pmic.200500459 · Cited by 29
Hogan, J., Klein, J., Wu, J., Chopra, P., Boons, G., Carvalho, L. E., Lin, C., & Zaia, J. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra118.000590 · Cited by 28
Shen, Y., Tolić, N., Purvine, S. O., & Smith, R. D. (2011) · Journal of Proteome Research · doi:10.1021/pr200597j · Cited by 28
Validation of an LC‐MS based approach for profiling histones in chronic lymphocytic leukemia
Su, X., Lucas, D. M., Zhang, L., Xu, H., Zabrouskov, V., Davis, M. E., Knapp, A. R., Young, D. C., Payne, P., Parthun, M. R., et al. (2009) · PROTEOMICS · doi:10.1002/pmic.200800333 · Cited by 28
Horn, D. M., Peters, E. C., Klock, H. E., Meyers, A., & Brock, A. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.03.016 · Cited by 28
Self-citationCalculation of the isotope cluster for polypeptides by probability grouping
Olson, M. T., & Yergey, A. L. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.10.007 · Cited by 28
McIlwain, S. J., Wu, Z., Wetzel, M., Belongia, D., Jin, Y., Wenger, K., Ong, I. M., & Ge, Y. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00035 · Cited by 27
Tolmachev, A. V., Monroe, M. E., Purvine, S. O., Moore, R., Jaitly, N., Adkins, J., Anderson, G., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac801376g · Cited by 27
Ye, X., Luke, B. T., Johann, D. J., Ono, A., Prieto, D. A., Chan, K. C., Issaq, H. J., Veenstra, T. D., & Blonder, J. (2010) · Analytical Chemistry · doi:10.1021/ac101284c · Cited by 27
Characterization of Proteoforms with Unknown Post-translational Modifications Using the MIScore
Kou, Q., Zhu, B., Wu, S., Ansong, C., Tolić, N., Paša-Tolić, L., & Liu, X. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b01098 · Cited by 26
Carvalho, V. V., Kit, M. C. S., & Webb, I. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00138 · Cited by 26
Identification of Peptide Features in Precursor Spectra Using Hardklör and Krönik
Hoopmann, M. R., MacCoss, M. J., & Moritz, R. L. (2012) · Current Protocols in Bioinformatics · doi:10.1002/0471250953.bi1318s37 · Cited by 26
Using dynamic programming to create isotopic distribution maps from mass spectra
McIlwain, S. J., Page, D., Huttlin, E. L., & Sussman, M. R. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm198 · Cited by 25
DESIGN AND ANALYSIS OF QUANTITATIVE DIFFERENTIAL PROTEOMICS INVESTIGATIONS USING LC-MS TECHNOLOGY
Bukhman, Y. V., Dharsee, M., Ewing, R. M., CHU, P., Topaloglou, T., Bihan, T. L., Goh, T., Duewel, H. S., Stewart, I. I., Wiśniewski, J. R., et al. (2008) · Journal of Bioinformatics and Computational Biology · doi:10.1142/s0219720008003321 · Cited by 25
Xiao, H., Cao, X., Wang, L., Run, X., Su, Y., Cheng, T., Sheng-gang, S., & Liang, Z. (2011) · PubMed · Cited by 25
Valence Parity Renders z•-Type Ions Chemically Distinct
Hubler, S. L., Jue, A. L., Keith, J. M., McAlister, G. C., Crăciun, G., & Coon, J. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja7099985 · Cited by 25
Introduction to Glycosylation and Mass Spectrometry
Patrie, S. M., Roth, M. J., & Kohler, J. J. (2012) · Methods in molecular biology · doi:10.1007/978-1-62703-146-2_1 · Cited by 24
Millán‐Martín, S., Carillo, S., Füssl, F., Sutton, J. N., Gazis, P., Cook, K., Scheffler, K., & Bones, J. (2020) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2020.11.006 · Cited by 24
Understanding reaction pathways in top-down ETD by dissecting isotope distributions: A mammoth task
Lermyte, F., Łącki, M. K., Valkenborg, D., Baggerman, G., Gambin, A., & Sobott, F. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2015.08.008 · Cited by 23
Chemical Cross-Linking and Mass Spectrometry as Structure Determination Tools
Novák, P., & Giannakopulos, A. E. (2007) · European Journal of Mass Spectrometry · doi:10.1255/ejms.868 · Cited by 23
Automatic assignment of metal-containing peptides in proteomic LC-MS and MS/MS data sets
Wootton, C. A., Lam, Y. P. Y., Willetts, M., van Agthoven, M. A., Barrow, M. P., Sadler, P. J., & O’Connor, P. B. (2017) · The Analyst · doi:10.1039/c7an00075h · Cited by 23
Jung, H.-J., Purvine, S. O., Kim, H., Petyuk, V., Hyung, S.-W., Monroe, M. E., Mun, D., Kim, K.-C., Park, J., Kim, S., et al. (2010) · Analytical Chemistry · doi:10.1021/ac101388b · Cited by 23
Glycoproteomics of cerebrospinal fluid in neurodegenerative disease
Sihlbom, C., Davidsson, P., Emmett, M. R., Marshall, A. G., & Nilsson, C. L. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.02.016 · Cited by 23
Proteoform profiling of endogenous single cells from rat hippocampus at scale
Su, P., Hollas, M. A. R., Plá, I., Rubakhin, S. S., Butun, F. A., Greer, J. B., Early, B. P., Fellers, R. T., Caldwell, M. A., Sweedler, J. V., et al. (2025) · Nature Biotechnology · doi:10.1038/s41587-025-02669-x · Cited by 22
Top-down protein identification using isotopic envelope fingerprinting
Xiao, K., Yu, F., & Tian, Z. (2016) · Journal of Proteomics · doi:10.1016/j.jprot.2016.10.010 · Cited by 22
Peris‐Díaz, M. D., Guráň, R., Zítka, O., Adam, V., & Krężel, A. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00651 · Cited by 22
Accurate and Efficient Resolution of Overlapping Isotopic Envelopes in Protein Tandem Mass Spectra
Xiao, K., Yu, F., Fang, H., Xue, B., Liu, Y., & Tian, Z. (2015) · Scientific Reports · doi:10.1038/srep14755 · Cited by 22
Deconvolution in mass spectrometry based proteomics
Guang, X., Stupak, J., Li, Y., Hu, L., Guo, B., & Li, J. (2018) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8103 · Cited by 22
Millea, K. M., Kass, I. J., Cohen, S. A., Krull, I. S., Gebler, J. C., & Berger, S. J. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.04.048 · Cited by 22
Parallel processing of large datasets from NanoLC-FTICR-MS measurements
van der Burgt, Y. E. M., Barbu, I., Konijnenburg, M., Biskup, M., Duursma, M. C., Heeren, R. M. A., Römpp, A., van Nieuwpoort, R. V., & Bal, H. E. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.09.005 · Cited by 21
Strategies for automating top-down protein analysis with Q-FTICR MS
Patrie, S. M., Robinson, D. E., Meng, F., Du, Y., & Kelleher, N. L. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.02.020 · Cited by 21
Multipurpose Dissociation Cell for Enhanced ETD of Intact Protein Species
Rose, C. M., Russell, J. D., Ledvina, A. R., McAlister, G. C., Westphall, M. S., Griep‐Raming, J., Schwartz, J. C., Coon, J. J., & Syka, J. E. P. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0622-0 · Cited by 21
McGee, J. P., Senko, M. W., Jooß, K., Soye, B. J. D., Compton, P. D., Kelleher, N. L., & Kafader, J. O. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03495 · Cited by 21
Targeted analysis of glycomics liquid chromatography/mass spectrometry data
Dreyfuss, J. M., Jacobs, C. L., Gindin, Y., Benson, G., Staples, G. O., & Zaia, J. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4235-1 · Cited by 21
Polacco, B. J., Purvine, S. O., Zink, E., LaVoie, S. P., Lipton, M. S. W., Summers, A. O., & Miller, S. M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.004853 · Cited by 21
Wong, J. W. H., Schwahn, A. B., & Downard, K. M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-266 · Cited by 21
High Performance Quantification of Complex High Resolution Polymer Mass Spectra
Bruycker, K. D., Krappitz, T., & Barner‐Kowollik, C. (2018) · ACS Macro Letters · doi:10.1021/acsmacrolett.8b00804 · Cited by 21
Basharat, A. R., Ning, X., & Liu, X. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00903 · Cited by 20
Young, N. L., Plazas-Mayorca, M. D., DiMaggio, P. A., Flaniken, I. Z., Beltran, A., Mishra, N., LeRoy, G., Floudas, C. A., & Garcia, B. A. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.01.020 · Cited by 20
Pu, F., Knizner, K. T., Robey, M. T., Radosevich, A. J., Ugrin, S. A., Elsen, N. L., Durbin, K. R., & Williams, J. D. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.2c00273 · Cited by 20
Themis: Batch Preprocessing for Ultrahigh-Resolution Mass Spectra of Complex Mixtures
Gavard, R., Rossell, D., Spencer, S. E. F., & Barrow, M. P. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02345 · Cited by 20
Simultaneous Kinetic Characterization of Multiple Protein Forms by Top Down Mass Spectrometry
Zhai, H., Dorrestein, P. C., Chatterjee, A., Begley, T. P., & McLafferty, F. W. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.02.016 · Cited by 20
Self-citationLiu, T., Qian, W., Camp, D., & Smith, R. D. (2007) · Methods in molecular biology · doi:10.1007/978-1-59745-255-7_7 · Cited by 20
Ultra-sensitive, high throughput and quantitative proteomics measurements
Jacobs, J., Monroe, M. E., Qian, W., Shen, Y., Anderson, G., & Smith, R. D. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.09.024 · Cited by 19
Metadata
- Authors
- Horn, D. M., Zubarev, R. A., & McLafferty, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Zubarev, Roman A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-04-01
- Volume
- 11
- Issue
- 4
- Pages
- 320-332
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1519955500
- Semantic Scholar
- b5b6aba35d2a0dde138b69c85b31a4ddf6c723c1
- Cited by
- 507
- References
- 46
- Citations by year
- 2026: 11 · 2025: 9 · 2024: 17 · 2023: 13 · 2022: 9 · 2021: 9 · 2020: 21 · 2019: 19 · 2018: 16 · 2017: 20 · 2016: 21 · 2015: 20 · 2014: 22 · 2013: 17 · 2012: 21
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National High Magnetic Field Laboratory
- National Institute of General Medical Sciences (GM 16609)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- least squares fitting, peptide mass mapping, high-resolution mass spectrometry
- MeSH terms
- Algorithms, Data Interpretation, Statistical, Gas Chromatography-Mass Spectrometry, Peptides, Proteins, Software, Mass Spectrometry, Chi-Square Distribution, Least-Squares Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.