Nonlinear viscoelastic effects in oscillatory shear deformation of brain tissue
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Two nonlinear constitutive models were used to describe the dynamic viscoelastic behavior of brain tissue. Small disc-shaped samples of bovine brain tissue were tested in simple shear using forced vibrations (0.5 to 200 Hz) with finite amplitudes (up to 20% Lagrangian shear strain). The samples response to simple, double, and triple harmonic inputs was determined in order to characterize the nonlinearities up to the third-order. A quasilinear viscoelastic model was proposed to describe the spatial nonlinearity. A fully nonlinear viscoelastic model with product-form multiple hereditary integrals was proposed to describe the spatial as well as the temporal nonlinearities. The fully nonlinear model demonstrated superiority at high frequencies (above 44 Hz). Under finite strains, the linear complex modulus showed nonrecoverable asymptotic strain conditioning behavior. Discrepancies observed in previously published studies and the threshold of functional failure of the neural tissue were shown to be related to this strain conditioning effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769 · cited 2×
“It is a well-known fact that in order to establish a unique constitutive relation, biological soft tissues should be preconditioned [16].”
BackgroundMethodCreep and Relaxation of Nonlinear Viscoelastic Materials
(1976) · North-Holland Series in Applied Mathematics and Mechanics · doi:10.1016/b978-0-7204-2369-3.x5001-2 · Cited by 887
Lockett, F. J. (1972) · Academic Press eBooks · Cited by 444
Gennarelli, T. A. (1993) · PubMed · Cited by 405
Rheological Response of Human Brain Tissue in Shear
Shuck, L. Z., & Advani, S. H. (1972) · Journal of Basic Engineering · doi:10.1115/1.3425588 · Cited by 308 · cited 4×
“Although the brain material behavior is nonlinear [5–7], previous studies on dynamic viscoelasticity of brain tissue have been based on the assumption of linearity of the constitutive relation [8–12].”
BackgroundMethodInfluentialDynamic mechanical properties of human brain tissue
Fallenstein, G. T., Hulce, V. D., & Melvin, J. W. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90079-7 · Cited by 288 · cited 2×
“Although the brain material behavior is nonlinear [5–7], previous studies on dynamic viscoelasticity of brain tissue have been based on the assumption of linearity of the constitutive relation [8–12].”
BackgroundBiomechanical Analysis of Experimental Diffuse Axonal Injury
MEANEY, D. F., SMITH, D. H., SHREIBER, D. I., BAIN, A. C., MILLER, R. T., ROSS, D. T., & GENNARELLI, T. A. (1995) · Journal of Neurotrauma · doi:10.1089/neu.1995.12.689 · Cited by 254
Shear Properties of Human Brain Tissue
Donnelly, B. R., & Medige, J. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2798289 · Cited by 237 · cited 2×
“Although the brain material behavior is nonlinear [5–7], previous studies on dynamic viscoelasticity of brain tissue have been based on the assumption of linearity of the constitutive relation [8–12].”
BackgroundMaterial characterization of the brainstem from oscillatory shear tests
Arbogast, K. B., & Margulies, S. S. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00068-2 · Cited by 225
Thibault, L. E., Gennarelli, T. A., Margulies, S. S., Marcus, J. R., & Eppinger, R. H. (1990) · Cited by 53
Wang, H. C., & Wineman, A. S. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90002-4 · Cited by 50
Mechanical Properties Of The Head
Stalnaker, R. L. (1969) · doi:10.33915/etd.9823 · Cited by 38
Cited by
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Mao, H., Zhang, L., Jiang, B., Genthikatti, V. V., Jin, X., Zhu, F., Makwana, R., Gill, A., Jandir, G., Singh, A., et al. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025101 · Cited by 369
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Metadata
- Authors
- Darvish, K. K., & Crandall, J. R.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2001-11-01
- Volume
- 23
- Issue
- 9
- Pages
- 633-645
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1984089709
- Cited by
- 198
- References
- 13
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.