Nonlinear viscoelastic effects in oscillatory shear deformation of brain tissue
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Two nonlinear constitutive models were used to describe the dynamic viscoelastic behavior of brain tissue. Small disc-shaped samples of bovine brain tissue were tested in simple shear using forced vibrations (0.5 to 200 Hz) with finite amplitudes (up to 20% Lagrangian shear strain). The samples response to simple, double, and triple harmonic inputs was determined in order to characterize the nonlinearities up to the third-order. A quasilinear viscoelastic model was proposed to describe the spatial nonlinearity. A fully nonlinear viscoelastic model with product-form multiple hereditary integrals was proposed to describe the spatial as well as the temporal nonlinearities. The fully nonlinear model demonstrated superiority at high frequencies (above 44 Hz). Under finite strains, the linear complex modulus showed nonrecoverable asymptotic strain conditioning behavior. Discrepancies observed in previously published studies and the threshold of functional failure of the neural tissue were shown to be related to this strain conditioning effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769 · cited 2×
“It is a well-known fact that in order to establish a unique constitutive relation, biological soft tissues should be preconditioned [16].”
BackgroundMethodCreep and Relaxation of Nonlinear Viscoelastic Materials
(1976) · North-Holland Series in Applied Mathematics and Mechanics · doi:10.1016/b978-0-7204-2369-3.x5001-2 · Cited by 887
Lockett, F. J. (1972) · Academic Press eBooks · Cited by 444
Gennarelli, T. A. (1993) · PubMed · Cited by 405
Rheological Response of Human Brain Tissue in Shear
Shuck, L. Z., & Advani, S. H. (1972) · Journal of Basic Engineering · doi:10.1115/1.3425588 · Cited by 308 · cited 4×
“Although the brain material behavior is nonlinear [5–7], previous studies on dynamic viscoelasticity of brain tissue have been based on the assumption of linearity of the constitutive relation [8–12].”
BackgroundMethodInfluentialDynamic mechanical properties of human brain tissue
Fallenstein, G. T., Hulce, V. D., & Melvin, J. W. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90079-7 · Cited by 288 · cited 2×
“Although the brain material behavior is nonlinear [5–7], previous studies on dynamic viscoelasticity of brain tissue have been based on the assumption of linearity of the constitutive relation [8–12].”
BackgroundBiomechanical Analysis of Experimental Diffuse Axonal Injury
MEANEY, D. F., SMITH, D. H., SHREIBER, D. I., BAIN, A. C., MILLER, R. T., ROSS, D. T., & GENNARELLI, T. A. (1995) · Journal of Neurotrauma · doi:10.1089/neu.1995.12.689 · Cited by 254
Shear Properties of Human Brain Tissue
Donnelly, B. R., & Medige, J. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2798289 · Cited by 237 · cited 2×
“Although the brain material behavior is nonlinear [5–7], previous studies on dynamic viscoelasticity of brain tissue have been based on the assumption of linearity of the constitutive relation [8–12].”
BackgroundMaterial characterization of the brainstem from oscillatory shear tests
Arbogast, K. B., & Margulies, S. S. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00068-2 · Cited by 225
Cited by
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Mao, H., Zhang, L., Jiang, B., Genthikatti, V. V., Jin, X., Zhu, F., Makwana, R., Gill, A., Jandir, G., Singh, A., et al. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025101 · Cited by 369
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
On the Development of the SIMon Finite Element Head Model
Takhounts, E. G., Eppinger, R. H., Campbell, J. Q., Tannous, R. E., Power, E. D., & Shook, L. S. (2003) · SAE Technical Paper Series · doi:10.4271/2003-22-0007 · Cited by 350
Fifty years of brain tissue mechanical testing: From in vitro to in vivo investigations
Chatelin, S., Constantinesco, A., & Willinger, R. (2010) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.3233/bir-2010-0576 · Cited by 342
Mechanical Heterogeneity of the Rat Hippocampus Measured by Atomic Force Microscope Indentation
Elkin, B. S., Azeloglu, E. U., Costa, K. D., & Morrison III, B. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0169 · Cited by 316
Kaufman, L. J., Brangwynne, C. P., Kasza, K. E., Filippidi, E., Gordon, V. D., Deisboeck, T. S., & Weitz, D. A. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061994 · Cited by 259
Mechanical characterization of brain tissue in tension at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.07.015 · Cited by 230
“Mostly dynamic oscillatory shear tests were conducted (Arbogast et al., 1997; Bilston et al., 2001; Brands et al., 2004; Darvish and Crandall, 2001; Fallenstein et al., 1969; Hrapko et al., 2006; Nicolle et al., 2004; Nicolle et al., 2005; Prange and Margulies, 2002; Shuck and Advani, 1972; Thibault and Margulies, 199…”
BackgroundMethodMeasurement of the hyperelastic properties of ex vivo brain tissue slices
Kaster, T., Sack, I., & Samani, A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.019 · Cited by 223
“48 h, which was consistent with previous works (Shuck and Advani, 1972; Donnelly and Medige, 1997; Darvish and Crandall, 2001; Nicolle et al., 2004).”
ResultThe mechanical behaviour of brain tissue: Large strain response and constitutive modelling
Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M. (2006) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2006043005004 · Cited by 208
“…behaviour of brain tissue has been mostly tested in vitro in shear (Arbogast and Margulies, 1998; Bilston et al. , 2001; Brands et al. , 2000; Darvish and Crandall, 2001; Donnely and Medige, 1997; Galford and McElhaney, 1970; Nicolle et al. , 2004; Peters et al. , 1997; Shuck and Advani,…”
InfluentialPrevost, T. P., Balakrishnan, A., Suresh, S., & Socrate, S. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.06.035 · Cited by 197
“More recently, the nonlinear features of the tissue response have been partly characterized in compression [34,35], tension [36] and shear [23,37].”
BackgroundResultMechanical characterization of brain tissue in simple shear at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.07.017 · Cited by 196
“1 to 10000 Hz (Arbogast et al., 1995; Arbogast and Margulies, 1998; Arbogast et al., 1997; Bilston et al., 1997; Brands et al., 1999; 2000a; 2000b; 2004; Darvish and Crandall, 2001; Fallenstein et al., 1969; Garo et al., 2007; Hirakawa et al., 1981; Hrapko et al., 2008; Nicolle et al., 2004; 2005; Prange and Margulies…”
MethodMorrison, B., Cater, H. L., Benham, C. D., & Sundstrom, L. E. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.06.014 · Cited by 196
Nicolle, S., Lounis, M., & Willinger, R. (2004) · SAE Technical Paper Series · doi:10.4271/2004-22-0011 · Cited by 193
Ballistic helmets – Their design, materials, and performance against traumatic brain injury
Kulkarni, S. G., Gao, X.-L., Horner, S. E., Zheng, J. Q., & David, N. V. (2013) · Composite Structures · doi:10.1016/j.compstruct.2013.02.014 · Cited by 190
The Influence of Test Conditions on Characterization of the Mechanical Properties of Brain Tissue
Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2907746 · Cited by 184
Viscoelastic characterization of in vitro canine tissue
Kiss, M. Z., Varghese, T., & Hall, T. J. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/002 · Cited by 172
A family of hyperelastic models for human brain tissue
Mihai, L. A., Budday, S., Holzapfel, G. A., Kuhl, E., & Goriely, A. (2017) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2017.05.015 · Cited by 171
“By contrast, stiffening in shear was reported in Budday et al. (2017) , Darvish and Crandall (2001) and Donnelly and Medige (1997) .”
BackgroundMethodInfluentialQuasi-Static Ultrasound Elastography
Varghese, T. (2009) · Ultrasound Clinics · doi:10.1016/j.cult.2009.10.009 · Cited by 169
Age-Dependent Regional Mechanical Properties of the Rat Hippocampus and Cortex
Elkin, B. S., Ilankovan, A., & Morrison, B. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4000164 · Cited by 166
Frequency dependent viscoelastic properties of porcine brain tissue
Li, W., Shepherd, D. E. T., & Espino, D. M. (2020) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2019.103460 · Cited by 23
Metadata
- Authors
- Darvish, K. K., & Crandall, J. R.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2001-11-01
- Volume
- 23
- Issue
- 9
- Pages
- 633-645
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1984089709
- Cited by
- 198
- References
- 13
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.