The DOI matches its Crossref record; 45 of the 47 references it cites were found in a registry or an index.
Technological advances in high-throughput screening
Abstract
A variety of assay technologies continue to be developed for high-throughput screening. These include cell-based assays, surrogate systems using microbial cells such as yeast and bacterial two-hybrid and three-hybrid systems, and systems to measure nucleic acid-protein and receptor-ligand interactions. Modifications have been developed for cell-free, homogeneous assay systems, such as time-resolved fluorescence, fluorescence polarization and the scintillation proximity assay. Innovations in engineering and chemistry have led to delivery systems for nanoliter volumes and sensitive biosensors for ultra-high-throughout screening conducted in nanoliter and picoliter volumes. Spectroscopic methods have been extended to read single molecule fluorescence. Technologies are being developed to identify new targets from genomic information in order to design the next generation of screens.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J. L., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,250
On/off blinking and switching behaviour of single molecules of green fluorescent protein
Dickson, R. M., Cubitt, A. B., Tsien, R. Y., & Moerner, W. E. (1997) · Nature · doi:10.1038/41048 · Cited by 1,366
Fei, H., Okano, H. J., Li, C., Lee, G.-H., Zhao, C., Darnell, R., & Friedman, J. M. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.13.7001 · Cited by 766
Zlokarnik, G., Negulescu, P. A., Knapp, T. E., Mere, L., Burres, N. S., Feng, L., Whitney, M. A., Roemer, K., & Tsien, R. Y. (1998) · Science · doi:10.1126/science.279.5347.84 · Cited by 691
Optical Amplification of Ligand-Receptor Binding Using Liquid Crystals
Gupta, V. K., Skaife, J. J., Dubrovsky, T. B., & Abbott, N. L. (1998) · Science · doi:10.1126/science.279.5359.2077 · Cited by 476
Romoser, V. A., Hinkle, P. M., & Persechini, A. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.20.13270 · Cited by 398
Applications of the green fluorescent protein in cell biology and biotechnology
Misteli, T., & Spector, D. L. (1997) · Nature Biotechnology · doi:10.1038/nbt1097-961 · Cited by 357
Monitoring conformational dynamics of a single molecule by selective fluorescence spectroscopy
Eggeling, C., Fries, J. R., Brand, L., Guenther, R., & Seidel, C. A. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1556 · Cited by 341
Molecular Photoionic AND Logic Gates with Bright Fluorescence and “Off−On” Digital Action
de Silva, A. P., Gunaratne, H. Q. N., & McCoy, C. P. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9712229 · Cited by 328
Fluorescence correlation spectroscopy: Diagnostics for sparse molecules
Maiti, S., Haupts, U. M., & Webb, W. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.22.11753 · Cited by 321
Real-time enzyme kinetics monitored by dual-color fluorescence cross-correlation spectroscopy
Kettling, U., Koltermann, A., Schwille, P., & Eigen, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1416 · Cited by 308
Activation of prokaryotic transcription through arbitrary protein–protein contacts
Dove, S. L., Joung, J. K., & Hochschild, A. (1997) · Nature · doi:10.1038/386627a0 · Cited by 282
Mesoporous Silica from Lyotropic Liquid Crystal Polymer Templates
Göltner, C. G., Henke, S., Weissenberger, M. C., & Antonietti, M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5 · Cited by 264
Liberles, S. D., Diver, S. T., Austin, D. J., & Schreiber, S. L. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.15.7825 · Cited by 199
Koltermann, A., Kettling, U., Bieschke, J., Winkler, T., & Eigen, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1421 · Cited by 155
Lanthanides as probes for time-resolved fluorometric immunoassays
Hemmilä, I. A. (1988) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365518809085747 · Cited by 143
Yang, T.-T., Sinai, P., Green, G., Kitts, P., Chen, Y., Lybarger, L. P., Chervenak, R. P., Patterson, G. H., Piston, D. W., & Kain, S. R. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.14.8212 · Cited by 140
Protein–Protein Contacts that Activate and Repress Prokaryotic Transcription
Hochschild, A., & Dove, S. L. (1998) · Cell · doi:10.1016/s0092-8674(00)81126-5 · Cited by 135
Huang, J., & Schreiber, S. L. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13396 · Cited by 129
Pausch, M. H. (1997) · Trends in biotechnology · doi:10.1016/s0167-7799(97)01119-0 · Cited by 124
Nourani, A., Wésolowski‐Louvel, M., Delaveau, T., Jacq, C., & Delahodde, A. (1997) · Molecular and Cellular Biology · doi:10.1128/mcb.17.9.5453 · Cited by 117
Tirode, F., Malaguti, C., Romero, F., Attar, R. M., Camonis, J., & Egly, J. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.37.22995 · Cited by 117
A Fluorescence Polarization Competition Immunoassay for Tyrosine Kinases
Seethala, R., & Menzel, R. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2455 · Cited by 86
A Homogeneous, Fluorescence Polarization Assay for Src-Family Tyrosine Kinases
Seethala, R., & Menzel, R. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2365 · Cited by 73
Persidis, A. (1998) · Nature Biotechnology · doi:10.1038/nbt0598-488 · Cited by 70
Fields, S. (1997) · Nature Genetics · doi:10.1038/ng0497-325 · Cited by 66
Persidis, A. (1998) · Nature Biotechnology · doi:10.1038/nbt0498-393 · Cited by 65
Lanthanides as probes for time-resolved fluorometric immunoassays
Hemmilä, I. A. (1988) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518809085747 · Cited by 63
Mutation of a Protease-sensitive Region in Firefly Luciferase Alters Light Emission Properties
Thompson, J. F., Geoghegan, K. F., Lloyd, D. B., Lanzetti, A. J., Magyar, R. A., Anderson, S. M., & Branchini, B. R. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.30.18766 · Cited by 59
Use of a Novel Homogeneous Fluorescent Technology in High Throughput Screening
Kolb, J. M., Yamanaka, G. A., & Manly, S. P. (1996) · SLAS DISCOVERY · doi:10.1177/108705719600100407 · Cited by 57
Kajkowski, E. M., Price, L. A., Pausch, M. H., Young, K. H., & Ozenberger, B. A. (1997) · Journal of Receptors and Signal Transduction · doi:10.3109/10799899709036610 · Cited by 54
Light on high-throughput screening: fluorescence-based assay technologies
Rogers, M. V. (1997) · Drug Discovery Today · doi:10.1016/s1359-6446(97)01016-7 · Cited by 42
A translational repression assay procedure (TRAP) for RNA–protein interactions in vivo
Paraskeva, E., Atzberger, A., & Hentze, M. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.951 · Cited by 39
Chan, T. Y., Chen, R., Sofia, M. J., Smith, B. C., & Glennon, D. (1997) · Tetrahedron Letters · doi:10.1016/s0040-4039(97)00496-6 · Cited by 33
Analysis of a peptide hormone–receptor interaction in the yeast two-hybrid system
Zhu, J.-W., & Kahn, C. R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.24.13063 · Cited by 27
Useful Vectors for the Two-Hybrid System in Mammalian Cells
Büchert, M., Schneider, S., Adams, M. T., Hefti, H. P., Moelling, K., & Hovens, C. M. (1997) · BioTechniques · doi:10.2144/97233bm10 · Cited by 21
A Scintillating Microplate Assay for the Assessment of Protein Kinase Activity
Nakayama, G. R., Nova, M. P., & Parandoosh, Z. (1998) · SLAS DISCOVERY · doi:10.1177/108705719800300106 · Cited by 17
Core system model: understanding the impact of reliability on high-throughput screening systems
Brandt, D. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(97)01136-7 · Cited by 13
Taylor, S. T., & Menzel, R. (1995) · Gene · doi:10.1016/0378-1119(95)00608-7 · Cited by 10
Ultra-High Throughput Screening
Shumate, C., Beckey, S., Coassin, P. J., & Stylli, H. (1997) · Laboratory Automation News · doi:10.1177/221106829700200406 · Cited by 6
Wallace, R. W. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01171-4 · Cited by 5
Persidis, A. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-100 · Cited by 4
FREEMANTLE, M. (1998) · Chemical & Engineering News · doi:10.1021/cen-v076n009.p035 · Cited by 2
Liquid crystals detect proteins with a glow
BRENNAN, M. B. (1998) · Chemical & Engineering News · doi:10.1021/cen-v076n013.p007 · Cited by 1
Chemosensor exploits anion competition
FREEMANTLE, M. (1998) · Chemical & Engineering News · doi:10.1021/cen-v076n010.p005a · Cited by 1
Research works printed but not linked: 11
- Razvi, 1998, The current status of high throughput screening and outlook for the future, part 1 (of outstanding interest), Drug Market Dev, 9, 89
- Sannes, 1997, Advances in high throughput screening (of outstanding interest), Spectrum: Drug Discovery and Design. Decision Resources, 8, 1
- Alderan, 1998, A novel approach to ultra-high-throughput screening, Gen Eng News, 18, 14
- Haberman, 1997, Genomics-based drug discovery: from gene sequencing to biology, Decision Resources, 7, 1
- Ashton, 1998, Proteomics — the new watchword for biotech (of outstanding interest), Scrip, 65, 32
- Kajkowski, 1997, Investigation of growth hormone releasing hormone releasing hormone receptor structure and activity using yeast expression technologies, J Recept Signal Transduct Res, 17, 293, 10.3109/10799899709036610 · DOI
- Fox, 1996, Packard applies HTRF tool to high-throughput screens, Gen Eng News, 16, 1
- Brandt, 1998, Microfluidics & high density microplates, Gen Eng News, 18, 30
- Krul, 1997, The commercialization of high-throughput screening technology (of outstanding interest), Spectrum, 143/1
- Zipkin, 1998, Orchid: microchemical processors, BioCentury, 6, 9
- Felder, 1997, High throughput screening and other applications of laboratory automation from LabAutomation ′97, Am Lab, 29, 26
Cited by
Sorted by citations
Combining docking and molecular dynamic simulations in drug design
Alonso, H., Bliznyuk, A. A., & Gready, J. E. (2006) · Medicinal Research Reviews · doi:10.1002/med.20067 · Cited by 784
Mechanism-Based Profiling of Enzyme Families
Evans, M. J., & Cravatt, B. F. (2006) · Chemical Reviews · doi:10.1021/cr050288g · Cited by 574
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2004) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 506
Modulators of Protein–Protein Interactions
Milroy, L.-G., Grossmann, T. N., Hennig, S., Brunsveld, L., & Ottmann, C. (2014) · Chemical Reviews · doi:10.1021/cr400698c · Cited by 497
Metadata
- Authors
- Fernandes, P. B.
- Corresponding author
- Fernandes, Prabhavathi B
- Venue
- Current Opinion in Chemical Biology
- Publisher
- Elsevier BV
- Published
- 1998-01
- Volume
- 2
- Issue
- 5
- Pages
- 597-603
- ISSN
- 1367-5931 (ISSN-L)
- OpenAlex
- W1975477535
- Cited by
- 170
- References
- 47
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2022: 2 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 3 · 2016: 2 · 2015: 5 · 2014: 6 · 2012: 6
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Opinion in Chemical Biology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Computational Drug Discovery Methods
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Keywords
- high-throughput screening, cell-based assays, yeast two-hybrid, protein-nucleic acid interactions, ligand-receptor interactions, time-resolved fluorescence, fluorescence polarization, scintillation proximity assay, biosensors, picoliter volumes, single-molecule fluorescence
- MeSH terms
- Calmodulin, DNA, Drug Evaluation, Preclinical, Enzyme-Linked Immunosorbent Assay, Escherichia coli, Fluoresceins, Fluorescence Polarization, Fluorescent Dyes, Indicators and Reagents, Luminescent Proteins, Miniaturization, RNA, Robotics, Saccharomyces cerevisiae, Sensitivity and Specificity, Spectrometry, Fluorescence, Green Fluorescent Proteins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review