Revolutionizing biodegradable metals
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Development of biodegradable metal implants is a complex problem because it combines engineering and medical requirements for a material. This article discusses the development of sensing and corrosion control techniques that can help in the design of biodegradable metallic implants. Biodegradable metallic implants dissolve as new tissue is formed. One of the most important factors in the design of biodegradable implants is to study the active interface, which should be monitored and controlled to address the medical concern of biocompatibility. Thus miniaturized and nanotechnology-based sensors that measure the activities of the degradation process and the formation of tissue are discussed for use with in vitro and in vivo experiments. These sensors can monitor chemical components and also cell activity and can provide new knowledge about biodegradable interfaces and how to actively control the interface to provide the best bioactivity to regenerate new tissue in a short time. Development of new alloys, nano-materials, miniature sensors, corrosion control coatings, and auxiliary applications such as biodegradable drug delivery capsules is expected to open up a new era in the engineering of materials for medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Helical microtubules of graphitic carbon
Iijima, S. (1991) · Nature · doi:10.1038/354056a0 · Cited by 43,098
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Hydrogen acts as a therapeutic antioxidant by selectively reducing cytotoxic oxygen radicals
Ohsawa, I., Ishikawa, M., Takahashi, K., Watanabe, M., Nishimaki, K., Yamagata, K., Katsura, K.-I., Katayama, Y., Asoh, S., & Ohta, S. (2007) · Nature Medicine · doi:10.1038/nm1577 · Cited by 2,560
Understanding Magnesium Corrosion—A Framework for Improved Alloy Performance
Song, G., & Atrens, A. (2003) · Advanced Engineering Materials · doi:10.1002/adem.200310405 · Cited by 2,056
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,627
(2011) · Wiley eBooks · doi:10.1002/9780470872864 · Cited by 1,514
Control of biodegradation of biocompatable magnesium alloys
Song, G. (2007) · Corrosion Science · doi:10.1016/j.corsci.2007.01.001 · Cited by 1,514
MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
Makar, G. L., & Kruger, J. (1993) · International Materials Reviews · doi:10.1179/095066093790326320 · Cited by 803
Solution-Gated Epitaxial Graphene as pH Sensor
Ang, P. K., Chen, W., Wee, A. T. S., & Loh, K. P. (2008) · Journal of the American Chemical Society · doi:10.1021/ja805090z · Cited by 723
Journal of Nanoscience and Nanotechnology
Nalwa, H. S., & Oliveira, O. N. (2011) · Cited by 712
Review of Electrochemical Hydrogen Sensors
Korotcenkov, G., Han, S. D., & Stetter, J. R. (2009) · Chemical Reviews · doi:10.1021/cr800339k · Cited by 546
Xu, L., Pan, F., Yu, G., Yang, L., Zhang, E., & Yang, K. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.001 · Cited by 505
A Possible Biodegradable Magnesium Implant Material
Song, G., & Song, S. (2007) · Advanced Engineering Materials · doi:10.1002/adem.200600252 · Cited by 487
Proceedings of the SPIE - The International Society for Optical Engineering
Kirby, A. K., Hands, P. J. W., & Love, G. D. (2005) · Edinburgh Research Explorer (University of Edinburgh) · Cited by 463
Nondestructive Evaluation: Theory, Techniques, and Applications
Shull, P. J. (2002) · Medical Entomology and Zoology · Cited by 439
Conducting Polymer‐Based Solid‐State Ion‐Selective Electrodes
Bobacka, J. (2006) · Electroanalysis · doi:10.1002/elan.200503384 · Cited by 418
Micro-Computed Tomography—Current Status and Developments
Ritman, E. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140130 · Cited by 360
Loh, K. J., Kim, J., Lynch, J. P., Kam, N. W. S., & Kotov, N. A. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/2/022 · Cited by 285
Potentiometric Ion Sensors Based on Conducting Polymers
Bobacka, J., Ivaska, A., & Lewenstam, A. (2003) · Electroanalysis · doi:10.1002/elan.200390042 · Cited by 277
Recent development and applications of optical and fiber-optic pH sensors
Lin, J. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00034-0 · Cited by 271
Walsh, F. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85560-c · Cited by 172
Carbon nanotube devices for nanoelectronics
Tsukagoshi, K., Yoneya, N., Uryu, S., Aoyagi, Y., Kanda, A., Ootuka, Y., & Alphenaar, B. (2002) · Physica B Condensed Matter · doi:10.1016/s0921-4526(02)00993-6 · Cited by 159
Nanotube electrodes and biosensors
Yun, Y., Dong, Z., Shanov, V. N., Heineman, W. R., Halsall, H. B., Bhattacharya, A., Conforti, L., Narayan, R. K., Ball, W. S., & Schulz, M. J. (2007) · Nano Today · doi:10.1016/s1748-0132(07)70171-8 · Cited by 150
Self-citationThe interaction between urokinase receptor and vitronectin in cell adhesion and signalling
Madsen, C. D., & Sidénius, N. (2008) · European Journal of Cell Biology · doi:10.1016/j.ejcb.2008.02.003 · Cited by 132
Ainslie, K. M., & Desai, T. A. (2008) · Lab on a Chip · doi:10.1039/b806446f · Cited by 131
Controlling the biodegradation rate of magnesium using biomimetic apatite coating
Zhang, Y., Zhang, G., & Wei, M. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31228 · Cited by 111
(2009) · Wiley eBooks · doi:10.1002/9780470891315 · Cited by 101
Novel lactate and pH biosensor for skin and sweat analysis based on single walled carbon nanotubes
Weber, J. E., Kumar, A., Kumar, A., & Bhansali, S. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.12.025 · Cited by 95
Ming Li, C., Dong, H., Cao, X., T. Luong, J., & Zhang, X. (2007) · Current Medicinal Chemistry · doi:10.2174/092986707780362970 · Cited by 94
Left-to-Right Shunt Detection by an Intravascular Electrode with Hydrogen as an Indicator
Clark, L. C., & Bargeron, L. M. (1959) · Science · doi:10.1126/science.130.3377.709 · Cited by 76
Functionalized Metallic Carbon Nanotube Devices for pH Sensing
Maroto, A., Balasubramanian, K., Burghard, M., & Kern, K. (2007) · ChemPhysChem · doi:10.1002/cphc.200600498 · Cited by 75
Hansi, C., Arab, A., Rzany, A., Ahrens, I., Bode, C., & Hehrlein, C. (2009) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.21834 · Cited by 58
Nanomedicine Design of Particles, Sensors, Motors, Implants, Robots, and Devices
Schulz, M. J., & Shanov, V. (2009) · Cited by 56
Self-citationA New pH Sensor Using the Fluorescence Quenching of Carbon Nanotubes
Cho, E. S., Hong, S. W., & Jo, W. H. (2008) · Macromolecular Rapid Communications · doi:10.1002/marc.200800457 · Cited by 37
Single-Wall Carbon Nanotube-Based pH Sensor Fabricated by the Spray Method
Kwon, J.-H., Lee, K., Lee, Y.-H., & Ju, B. (2006) · Electrochemical and Solid-State Letters · doi:10.1149/1.2217131 · Cited by 29
Functionalization of carbon nanotubes with a pH-responsive molecule to produce a pH sensor
Zhao, L., Nakayama, T., Tomimoto, H., Shingaya, Y., & Huang, Q. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/32/325501 · Cited by 20
Mechanical and biological properties of nanoporous carbon membranes
Narayan, R. J., Aggarwal, R., Wei, W., Jin, C., Monteiro-Riviere, N. A., Crombez, R. C., & Shen, W. C. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034107 · Cited by 19
Chen, M. T., Gomez, L. M., Ishikawa, F. N., Vernier, P. T., Zhou, C., & Gundersen, M. A. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/29/295101 · Cited by 12
Magnetic nanotubes and their potential use in neuroscience applications
Chen, L., Xie, J., Srivatsan, M., & Varadan, V. K. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.668748 · Cited by 5
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Recent advances in bone tissue engineering scaffolds
Bose, S., Roy, M., & Bandyopadhyay, A. (2012) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.07.005 · Cited by 2,206
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Biodegradable magnesium-based implants in orthopedics-a general review and perspectives
Wang, J., Xu, J., Hopkins, C., Chow, D. H., & Qin, L. (2020) · Advanced Science · doi:10.1002/advs.201902443 · Cited by 574
Mouriño, V., Cattalini, J. P., & Boccaccini, A. R. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0611 · Cited by 441
Metadata
- Authors
- Yun, Y., Dong, Z., Lee, N., Liu, Y., Xue, D., Guo, X., Kuhlmann, J., Doepke, A., Halsall, H. B., Heineman, W., Sundaramurthy, S., Schulz, M. J., Yin, Z., Shanov, V., Hurd, D., Nagy, P., Li, W., & Fox, C.
- Venue
- Materials Today
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 12
- Issue
- 10
- Pages
- 22-32
- ISSN
- 1369-7021 (ISSN-L)
- OpenAlex
- W1976245301
- Cited by
- 252
- References
- 44
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.