Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 280

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Cardiac Resynchronization Therapy in Advanced Heart Failure the Multicenter InSync Clinical Study

Open access
Gras, Daniel, Leclercq, Christophe, Tang, Anthony S.L., Bucknall, Cliff, Luttikhuis, Henk Oude, Kirstein-Pedersen, Anders·2002·European Journal of Heart Failure

Abstract

Background: recent short-term observations have shown an improvement in cardiac function and heart failure symptoms from atrio-biventricular pacing. This study was designed to assess the safety and feasibility of an atrio-biventricular transvenous pacing system, and examine the long-term effects of cardiac resynchronization in patients with advanced heart failure and ventricular conduction abnormalities. Methods and results: between August, 1997 and November, 1998, 103 patients received a cardiac resynchronization system (CRS) consisting of a pulse generator interfaced with an atrio-biventricular lead system, including a lead designed for left ventricular (LV) pacing via cardiac veins. Baseline evaluation included 12-lead electrocardiogram, estimation of New York Heart Association (NYHA) functional class, assessment of quality of life (QOL), and distance covered during a 6-min walk (6-MW). Detailed echocardiographic data were also collected in a subset of 46 patients. Measurements were repeated in all surviving patients at 1, 3, 6 and 12 months after implantation of the CRS. A single, self-limiting procedure-related complication occurred. Over a follow-up of 12 months, 21 patients died. The 12-month actuarial survival was 78% (CI 70–87%). Nine surviving patients were withdrawn from the study during long-term follow-up for miscellaneous reasons. At each point of follow-up, a significant shortening of QRS duration was measured. In addition, significant improvements were observed in mean NYHA functional class, 6-MW and QOL score. In the 46 patients with complete echocardiographic data, LV ejection fraction increased from 21.7±6.4% at baseline to 26.1±9.0% at last follow-up (P-0.006), LV end diastolic dimension decreased from 72.7±9.2 to 71.6±9.1 mm (P-0.233), interventricular mechanical delay decreased from 27.5±32.1 to 20.3±25.5 ms (P-0.243), mitral regurgitation apical four-chamber area decreased from 7.66±5.5 to 6.69±5.9 cm2 (P-0.197), and left ventricular filling time increased from 363±127 to 408±111 ms (P-0.002). Conclusions: long-term cardiac resynchronization can be safely and reliably achieved by transvenous atrial synchronized right and left ventricular pacing. These changes were accompanied by clinically relevant improvements in functional status and QOL, as well as a measurable increase in LV performance. The outcome of randomised controlled trials is awaited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1388-9842(02)00018-1

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 280

Metadata

Authors
Gras, D., Leclercq, C., Tang, A. S. L., Bucknall, C., Luttikhuis, H. O., & Kirstein-Pedersen, A.
Venue
European Journal of Heart Failure
Published
2002-06-01
Volume
4
Issue
3
Pages
311-320
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W2023989974
Cited by
280
References
29
FWCI
19.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Resynchronization Therapy in Advanced Heart Failure the Multicenter InSync Clinical Study. https://app.cochat.ai/papers/10.1016/s1388-9842(02)00018-1
The paper
Gras, D., Leclercq, C., Tang, A. S. L., Bucknall, C., Luttikhuis, H. O., & Kirstein-Pedersen, A. (2002). Cardiac Resynchronization Therapy in Advanced Heart Failure the Multicenter InSync Clinical Study. European Journal of Heart Failure. https://doi.org/10.1016/s1388-9842(02)00018-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.