Artificial intelligence-supported screen reading versus standard double reading in the Mammography Screening with Artificial Intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background Retrospective studies have shown promising results using artificial intelligence (AI) to improve mammography screening accuracy and reduce screen-reading workload; however, to our knowledge, a randomised trial has not yet been conducted. We aimed to assess the clinical safety of an AI-supported screen-reading protocol compared with standard screen reading by radiologists following mammography.Methods In this randomised, controlled, population-based trial, women aged 40-80 years eligible for mammography screening (including general screening with 1·5-2-year intervals and annual screening for those with moderate hereditary risk of breast cancer or a history of breast cancer) at four screening sites in Sweden were informed about the study as part of the screening invitation. Those who did not opt out were randomly allocated (1:1) to AI-supported screening (intervention group) or standard double reading without AI (control group). Screening examinations were automatically randomised by the Picture Archive and Communications System with a pseudo-random number generator after image acquisition. The participants and the radiographers acquiring the screening examinations, but not the radiologists reading the screening examinations, were masked to study group allocation. The AI system (Transpara version 1.7.0) provided an examination-based malignancy risk score on a 10-level scale that was used to triage screening examinations to single reading (score 1-9) or double reading (score 10), with AI risk scores (for all examinations) and computer-aided detection marks (for examinations with risk score 8-10) available to the radiologists doing the screen reading. Here we report the prespecified clinical safety analysis, to be done after 80 000 women were enrolled, to assess the secondary outcome measures of early screening performance (cancer detection rate, recall rate, false positive rate, positive predictive value [PPV] of recall, and type of cancer detected [invasive or in situ]) and screen-reading workload. Analyses were done in the modified intention-to-treat population (ie, all women randomly assigned to a group with one complete screening examination, excluding women recalled due to enlarged lymph nodes diagnosed with lymphoma). The lowest acceptable limit for safety in the intervention group was a cancer detection rate of more than 3 per 1000 participants screened. The trial is registered with ClinicalTrials.gov, NCT04838756, and is closed to accrual; follow-up is ongoing to assess the primary endpoint of the trial, interval cancer rate.Findings Between April 12, 2021, and July 28, 2022, 80 033 women were randomly assigned to AI-supported screening (n=40 003) or double reading without AI (n=40 030). 13 women were excluded from the analysis. The median age was 54·0 years (IQR 46·7-63·9). Race and ethnicity data were not collected. AI-supported screening among 39 996 participants resulted in 244 screen-detected cancers, 861 recalls, and a total of 46 345 screen readings. Standard screening among 40 024 participants resulted in 203 screen-detected cancers, 817 recalls, and a total of 83 231 screen readings. Cancer detection rates were 6·1 (95% CI 5·4-6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4-5·8) per 1000 in the control group-a ratio of 1·2 (95% CI 1·0-1·5; p=0·052). Recall rates were 2·2% (95% CI 2·0-2·3) in the intervention group and 2·0% (1·9-2·2) in the control group. The false positive rate was 1·5% (95% CI 1·4-1·7) in both groups. The PPV of recall was 28·3% (95% CI 25·3-31·5) in the intervention group and 24·8% (21·9-28·0) in the control group. In the intervention group, 184 (75%) of 244 cancers detected were invasive and 60 (25%) were in situ; in the control group, 165 (81%) of 203 cancers were invasive and 38 (19%) were in situ. The screen-reading workload was reduced by 44·3% using AI.Interpretation AI-supported mammography screening resulted in a similar cancer detection rate compared with standard double reading, with a substantially lower screen-reading workload, indicating that the use of AI in mammography screening is safe. The trial was thus not halted and the primary endpoint of interval cancer rate will be assessed in 100 000 enrolled participants after 2-years of follow up.Funding Swedish Cancer Society, Confederation of Regional Cancer Centres, and the Swedish governmental funding for clinical research (ALF).
Overview
CoChat Summary
TL;DR
In the MASAI trial, AI-supported screen reading resulted in a similar cancer detection rate to standard double reading (6·1 vs 5·1 per 1000 screened; ratio 1·2, 95% CI 1·0–1·5) and reduced screen-reading workload by 44·3%. The prespecified safety analysis supported continuing the trial to assess the primary endpoint of interval cancer rate.
Key findings
- Cancer detection rate was 6·1 per 1000 screened participants (95% CI 5·4–6·9) in the AI-supported group versus 5·1 per 1000 (4·4–5·8) in the control group, a ratio of 1·2 (95% CI 1·0–1·5; p=0·052), above the prespecified lowest acceptable safety limit of more than 3 per 1000.
- Recall rate was 2·2% (95% CI 2·0–2·3) with AI versus 2·0% (1·9–2·2) in controls; false positive rate was 1·5% (95% CI 1·4–1·7) in both groups; PPV of recall was 28·3% (25·3–31·5) versus 24·8% (21·9–28·0).
- AI-supported screening detected 244 cancers (184 [75%] invasive, 60 [25%] in situ) among 39,996 participants; standard screening detected 203 cancers (165 [81%] invasive, 38 [19%] in situ) among 40,024 participants.
- Screen-reading workload was reduced by 44·3% with AI: 46,345 readings versus 83,231 readings.
Methods
- Randomised, controlled, population-based, non-inferiority, single-blinded screening accuracy study at four Swedish screening sites; women aged 40–80 years eligible for mammography screening were randomly allocated 1:1 to AI-supported screening (n=40,003) or standard double reading without AI (n=40,030); 13 women were excluded, leaving a modified intention-to-treat population.
- The AI system (Transpara version 1.7.0) provided an examination-based malignancy risk score on a 10-level scale, triaging examinations with score 1–9 to single reading and score 10 to double reading; AI risk scores and computer-aided detection marks (for scores 8–10) were available to radiologists.
- This prespecified clinical safety analysis, performed after 80,000 women were enrolled, assessed early screening performance (cancer detection rate, recall rate, false positive rate, PPV of recall, and type of cancer detected) and screen-reading workload.
Limitations
- Stated in the paper: race and ethnicity data were not collected; follow-up is ongoing to assess the primary endpoint of interval cancer rate, so this report covers early screening performance rather than final trial outcomes.
- Evident from the text: the findings come from a single trial in Sweden using one AI system and version, so longer-term outcomes and broader generalisability remain to be established.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 0 Not checked · 31 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In the intervention group, 184 (75%) of 244 cancers detected were invasive and 60 (25%) were in situ; in the control group, 165 (81%) of 203 cancers were invasive and 38 (19%) were in situ.”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The PPV of recall was 28·3% (95% CI 25·3–31·5) in the intervention group and 24·8% (21·9–28·0) in the control group.”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“AI-supported screening among 39 996 participants resulted in 244 screen-detected cancers, 861 recalls, and a total of 46 345 screen readings.”
plainn = 39,996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Cancer detection rates were 6·1 (95% CI 5·4–6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4–5·8) per 1000 in the control group—a ratio of 1·2 (95% CI 1·0–1·5; p=0·052).”
plainn = 24- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Cancer detection rates were 6·1 (95% CI 5·4–6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4–5·8) per 1000 in the control group—a ratio of 1·2 (95% CI 1·0–1·5; p=0·052).”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
15 more claims
Create a free account to see all 31 claims and every source verdict.
- Probably not a substantial claim. 10
- It may state two separate claims as one. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As shown in Figure 2A, AI agents possess the capacity to process extensive patient data, including medical histories, diagnostic test results, and imaging, thereby aiding healthcare professionals in making more informed and precise diagnostic decisions.62,63,64,65,66,67,68,69”
From A foundational architecture for AI agents in healthcare (2025) · cites this paper as [67]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
In the citing paper
“Likewise, AI exhibits promising potential in oncology and radiology for automatically identifying and categorising neoplastic lesions observed in thoracic and abdominal imaging, including X-ray, computed tomography (CT) and the more challenging magnetic resonance (MR) imaging.5,6”
From Artificial intelligence and endo-histo-omics: new dimensions of precision endoscopy and histology in inflammatory bowel disease (2024) · cites this paper as [5]
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Self-citationDiagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Transparency in artificial intelligence
Larsson, S., & Heintz, F. (2020) · Internet Policy Review · doi:10.14763/2020.2.1469 · Cited by 458
Self-citationSechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338
Dembrower, K., Wåhlin, E., Liu, Y., Salim, M., Smith, K., Lindholm, P., Eklund, M., & Strand, F. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30185-0 · Cited by 290
Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F. (2020) · JAMA Oncology · doi:10.1001/jamaoncol.2020.3321 · Cited by 288
Breast Cancer Screening and Diagnosis: A Synopsis of the European Breast Guidelines
Schünemann, H. J., Lerda, D., Quinn, C., Follmann, M., Alonso-Coello, P., Rossi, P. G., Lebeau, A., Nyström, L., Broeders, M., Ioannidou-Mouzaka, L., et al. (2020) · Annals of Internal Medicine · doi:10.7326/m19-2125 · Cited by 286
Self-citation
Cited by
Items 201–300 of 596
Healthcare Violence and the Potential Promises and Harms of Artificial Intelligence
Kavanagh, K. T., Pontus, C., & Cormier, L. E. (2024) · Journal of Patient Safety · doi:10.1097/pts.0000000000001245 · Cited by 6
Lamb, L. R., Lehman, C. D., Do, S., Kim, K., Langarica, S., & Bahl, M. (2024) · AI in Precision Oncology · doi:10.1089/aipo.2024.0022 · Cited by 8
AI-supported approaches for mammography single and double reading: A controlled multireader study
Brancato, B., Magni, V., Saieva, C., Risso, G. G., Buti, F., Catarzi, S., Ciuffi, F., Peruzzi, F., Regini, F., Ambrogetti, D., et al. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112101 · Cited by 9
AI Should Read Mammograms Only When Confident: A Hybrid Breast Cancer Screening Reading Strategy
Verboom, S. D., Kroes, J., Pires, S., Broeders, M. J. M., & Sechopoulos, I. (2025) · Radiology · doi:10.1148/radiol.242594 · Cited by 11
Lastrucci, A., Iosca, N., Wandael, Y., Barra, A., Ricci, R., Cucchiari, J. N., Forini, N., Lepri, G., & Giansanti, D. (2025) · Diagnostics · doi:10.3390/diagnostics15172197 · Cited by 9
Çelìk, L., Güner, D. C., Özçağlayan, Ö., Çubuk, R., & Arıbal, E. (2023) · Acta Radiologica · doi:10.1177/02841851231200785 · Cited by 7
Clinical Integration of Artificial Intelligence for Breast Imaging
Wilkinson, L., Dunbar, J. K., & Lip, G. (2024) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2023.12.006 · Cited by 8
Current status and prospects of breast cancer imaging-based diagnosis using artificial intelligence
Sekine, C., & Horiguchi, J. (2024) · International Journal of Clinical Oncology · doi:10.1007/s10147-024-02594-0 · Cited by 7
“The Mammography Screening with Artificial Intelligence (MASAI) trial, a randomized controlled trial, revealed that AI-supported MG screening resulted in a similar cancer detection rate compared to standard double reading, with a lower screen-reading workload [27].”
Plimpton, S. R., Milch, H. S., Sears, C., Chalfant, J. S., Hoyt, A. C., Fischer, C. P., Hsu, W. W. Y., & Joines, M. M. (2024) · Journal of Breast Imaging · doi:10.1093/jbi/wbae058 · Cited by 6
Shahrvini, T., Wood, E. J., Joines, M. M., Nguyen, H. B., Hoyt, A. C., Chalfant, J. S., Capiro, N. M., Fischer, C. P., Sayre, J. W., Hsu, W. W. Y., et al. (2025) · American Journal of Roentgenology · doi:10.2214/ajr.25.33412 · Cited by 8
Exploring Large Language Models for Specialist-Level Oncology Care
Palepu, A. K., Dhillon, V., Niravath, P. A., Weng, W., Prasad, P., Saab, K. K., Tanno, R., Cheng, Y., Mai, H., Burns, E. A., et al. (2025) · NEJM AI · doi:10.1056/aics2500025 · Cited by 18
Large Language Models as an Inexpensive and Effective Extra Set of Eyes in Radiology Reporting
Forman, H. P. (2024) · Radiology · doi:10.1148/radiol.240844 · Cited by 6
The augmentation myth: AI, economics, and workforce substitution in radiology
Cuocolo, R., & Huisman, M. (2026) · European Radiology · doi:10.1007/s00330-026-12568-7 · Cited by 6
Artificial Intelligence for Breast Cancer Screening: Trade-offs between Sensitivity and Specificity
Bahl, M., & Do, S. (2024) · Radiology Artificial Intelligence · doi:10.1148/ryai.240184 · Cited by 5
Advancements in the Application of the Intersection of Medicine and Engineering in Cancer Research
Chen, H., Zhang, G.-M., Qian, Y., Yang, P., Li, X., Wang, J., Wang, J., Hu, Y.-X., Xiao, H., Zhong, Q., et al. (2025) · Cancer Nexus · doi:10.1002/cnx2.70003 · Cited by 6
van Winkel, S. L., Sechopoulos, I., Rodríguez‐Ruiz, A., Veldkamp, W. J. H., Gennaro, G., Chevalier, M. L., Helbich, T. H., Zhang, T., Wallis, M., & Mann, R. M. (2025) · Diagnostics · doi:10.3390/diagnostics15121566 · Cited by 6
Chan, M. D. Z., Tjio, C. K. E., Chan, T. L. Y., Tan, Y. L., Chua, A. X. Y., Loh, S. K. Y., Leow, G. Z., Gan, M. Y., Lim, X., Choo, A. K., et al. (2025) · Cancers · doi:10.3390/cancers17193198 · Cited by 8
AI supported diagnostic innovations for impact in global women’s health
Linder, N., Nyirenda, D., Mårtensson, A., Kaingu, H., Ngasala, B., & Lundin, J. (2025) · BMJ · doi:10.1136/bmj-2025-086009 · Cited by 13
“…and sepsis 11 12 ; AI image analysis methods can aid diagnosis of sexually transmitted and parasitic infections 13 14 ; an AI supported approach to breast cancer detection can either reduce radiologists’ workload in mammography workflows 15 or, in non-specialist healthcare settings, support…”
Pfob, A., Pinker, K., Vaz-Luís, I., Meglio, A. D., Cardoso, M. J., Curigliano, G., Gentilini, O., Gruber, G., Hauser, N., Heil, J., et al. (2025) · The Lancet Oncology · doi:10.1016/s1470-2045(25)00463-2 · Cited by 11
Self-citationCardoso, R., Ola, I. O., Jansen, L., Hackl, M., Ihle, P., Francart, J., Damme, N. V., Valerianova, Z., Atanasov, T., Májek, O., et al. (2025) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2025.101574 · Cited by 5
“29 However, such improvements in detection should also be assessed in relation to potential additional harms, namely overdiagnosis and overtreatment.”
Self-citationThorley, N., Parry, T., Brembilla, G., Giganti, F., Barrett, T., Eldred‐Evans, D., Mayor, N., Lamb, A., Cristinacce, P. L. H., Gong, F., et al. (2026) · European Radiology · doi:10.1007/s00330-025-12250-4 · Cited by 5
Frazer, H. M. L., Hopper, J. L., Nguyen, T. L., Elliott, M. S., Kunicki, K., Al-Qershi, O. M., Schmidt, D. F., Makalic, E., Li, S., Fox, S., et al. (2026) · The Lancet Digital Health · doi:10.1016/j.landig.2026.100987 · Cited by 9
Warner‐Smith, M., Ren, K., Mistry, C., Walton, R., Roder, D. M., Bhola, N., McGill, S., & O'Brien, T. A. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-082350 · Cited by 6
“While the study by Lång et al 12 used a robust prospective design, it is limited by insufficient follow-up to assess interval cancers.”
MethodGupta, A., Lam, B. D., Zerbey, S., Rosovsky, R. P. G., Lake, L. L., Dodge, L. E., Adamski, A., Reyes, N., Abe, K., Vlachos, I. S., et al. (2024) · Blood Vessels Thrombosis & Hemostasis · doi:10.1016/j.bvth.2024.100031 · Cited by 6
“19 Clinical trials, such as the Mammography Screening with AI trial studying AI-assisted mammography, 20 support the themes of increased efficiency and reduced clinician burden with using AI.”
The use of a ChatGPT‐4‐based chatbot in teledermatology: A retrospective exploratory study
Shapiro, J., Avitan‐Hersh, E., Greenfield, B., Khamaysi, Z., Dodiuk‐Gad, R. P., Valdman‐Grinshpoun, Y., Freud, T., & Lyakhovitsky, A. (2025) · JDDG Journal der Deutschen Dermatologischen Gesellschaft · doi:10.1111/ddg.15609 · Cited by 13
Evolution of an Artificial Intelligence-Powered Application for Mammography
Vasilev, Y. A., Андреевич, Р. Д., Vladzymyrskyy, A. V., Omelyanskaya, O. V., Дмитриевич, П. Л., Михайлович, Ш. И., Nikitin, E. D., Kapninskiy, A., & Arzamasov, K. M. (2025) · Diagnostics · doi:10.3390/diagnostics15070822 · Cited by 5
Clinical Application of AI in Mammography: Insights from a Prospective Study
Yılmaz, E., Şeker, M. E., Güldoğan, N., Turk, E. B., Erdemli, S., Köylüoğlu, Y. O., Sancak, S. N., & Arıbal, E. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.05.025 · Cited by 9
Hyperspectral Imaging for Benign and Malignant Diagnosis of Breast Tumors
He, Y., Zhao, Y., Xu, J., Zhou, D., Shi, W., Wang, Y., Wang, Y., Wang, X., Zhang, M., Kang, N., et al. (2025) · Journal of Biophotonics · doi:10.1002/jbio.202500188 · Cited by 5
“Integrating such AI-driven pathological insights into intraoperative margin assessment—via label-free hyperspectral imaging—promises to bridge the gap between real-time tissue characterization and surgical decision-making [3, 4].”
Artificial Intelligence And Women's Health: Innovations, Challenges, And Ethical Considerations
Korytnikova, E. (2023) · Advances In Clinical And Medical Research · doi:10.52793/acmr.2023.4(3)-59 · Cited by 8
Utilizing ChatGPT to Facilitate Referrals for Fetal Echocardiography
Kopylov, L. G., Goldrat, I., Maymon, R., Svirsky, R., Wiener, Y., & Klang, E. (2024) · Fetal Diagnosis and Therapy · doi:10.1159/000539658 · Cited by 5
Rejmer, C., Dihge, L., Bendahl, P., Förnvik, D., Dustler, M., & Rydén, L. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1394448 · Cited by 7
Mansour, S. M., Sweed, E. M. M., Gomaa, M. M. M., Hussein, S. A., Abdallah, E., Nada, Y. M. A. I., Kamal, R. M., Mohamed, G., Taha, S. N., & Moustafa, A. F. I. (2024) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-024-01353-5 · Cited by 7
“The study has shown that a strategy of double reading by one radiologist plus AI resulted in an increased cancer detection rate compared with double reading by two radiologists [16].”
ResultKregting, L. M., van den Oever, D., Pennings, L. J., Pijnappel, R. M., van Ravesteyn, N. T., Verschuur, E., van Oirsouw, M., Dunning, L., Mannetje, H. ‘., van Engen, R. E., et al. (2025) · European Radiology · doi:10.1007/s00330-024-11324-z · Cited by 5
AI image analysis as the basis for risk-stratified screening
Strand, F. (2025) · Japanese Journal of Radiology · doi:10.1007/s11604-025-01734-4 · Cited by 7
“…to detect potential malignancies and have demonstrated marked improvements in clinical trials such as ScreenTrustCAD, employing AI as an independent reader, and MASAI (Mammography Screening with Artificial Intelligence trial), employing AI to triage examinations to one or two radiologists [5, 6].”
Comparison of AI-integrated pathways with human-AI interaction for population mammographic screeningPreprint
Frazer, H. M. L., Peña‐Solórzano, C. A., Kwok, C. F., Elliott, M. S., Chen, Y., Wang, C., the BRAIx team, Lippey, J., Hopper, J. L., Brotchie, P., et al. (2022) · medRxiv · doi:10.1101/2022.11.23.22282646 · Cited by 5
AI in breast cancer screening: a critical overview of what we know
Raya-Povedano, J. L. (2023) · European Radiology · doi:10.1007/s00330-023-10530-5 · Cited by 11
“In the preliminary results of their randomized study (MASAI), Lang et al [9] demonstrated that detection of cancers was non-inferior and recall rate of false positives was not higher when 90% of lower suspicion studies were single read and only 10% of higher suspicion studies were double read.”
Youssef, A., Fronk, D., Grimes, J. N., Cheuy, L. Y., & Larson, D. B. (2024) · medRxiv · doi:10.1101/2024.07.12.24309602 · Cited by 7
“In this study, the other 11 studies were retrospective comparisons of their algorithmic output to earlier findings (28,29).”
ResultMarinovich, M. L., Lotter, W. E., Waddell, A., & Houssami, N. (2024) · Journal of Medical Screening · doi:10.1177/09691413241262960 · Cited by 7
“11,13,14 However, interval cancer ascertainment will require longer-term follow-up so this evidence base will continue to mature over time.”
Enhancing breast positioning quality through real-time AI feedback
Sexauer, R., Riehle, F., Borkowski, K., Ruppert, C., Potthast, S., & Schmidt, N. (2025) · European Radiology · doi:10.1007/s00330-025-11812-w · Cited by 7
Moger, T. A., Nardin, S. B., Holen, Å. S., Moshina, N., & Hofvind, S. S. H. (2025) · Journal of Medical Screening · doi:10.1177/09691413251372829 · Cited by 4
Self-citationKhalid, S. A., Khaliq, T., Rehman, Y. N., Anwar, Z., & Mirani, W. (2025) · Cureus · doi:10.7759/cureus.95943 · Cited by 4
“The MASAI trial demonstrated a 44% reduction in radiologist reading workload [13], while the Friedewald study showed that AI triage shortened time to biopsy by 30%, reducing patient anxiety and accelerating treatment initiation [16].”
Influentialİsmayılov, R., Altundağ, Ö., & Akçalı, Z. (2025) · Immunotherapy · doi:10.1080/1750743x.2025.2580272 · Cited by 6
Sossavi, E., Roy, C., & Molière, S. (2026) · European Journal of Radiology Open · doi:10.1016/j.ejro.2026.100727 · Cited by 11
“MASAI [19] pioneered a risk-allocation (T-ALLOC) scheme: no exam was skipped.”
InfluentialSingh, S., Crean, R., O’Driscoll, J., Cahir, C., Briody, H., Bambrick, M., NiMhuircheartaigh, N. M., Hambly, N. M., Duke, D., Mullooly, M., et al. (2026) · European Radiology · doi:10.1007/s00330-025-12288-4 · Cited by 5
Lehnen, T., Polenske, D., Wichtmann, B. D., & Lehnen, N. C. (2026) · European Radiology · doi:10.1007/s00330-026-12359-0 · Cited by 7
Yazarkan, Y., Sönmez, G., Sahin, T. K., Rizzo, A., & Güven, D. C. (2026) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2026.2648127 · Cited by 5
“Randomized studies such as MASAI and ScreenTrustCAD in Sweden have shown that AI can function as an independent reader in national screening programs, safely replacing one human reader in double-reading systems while reducing workload [14,131].”
Twilt, J. J., Saha, A., Bosma, J. S., Giannarini, G., Padhani, A. R., Yakar, D., Elschot, M., Veltman, J., Fütterer, J. J., Huisman, H. J., et al. (2026) · Radiology Imaging Cancer · doi:10.1148/rycan.250461 · Cited by 5
Artificial intelligence for breast cancer screening: breathtaking results and a word of caution
Segnan, N., & Ponti, A. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00336-4 · Cited by 4
Rasoolzadeh, N., Zhang, T., Gao, Y., van Dijk, J. M., Yang, Q., Tan, T., & Mann, R. M. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-77789-9_5 · Cited by 5
Hovda, T., Larsen, M., Bergan, M. B., Gjesvik, J., Akslen, L. A., & Hofvind, S. S. H. (2025) · European Radiology · doi:10.1007/s00330-025-11521-4 · Cited by 6
Self-citationHa, S. M., Lee, J. M., Jang, M., Kim, H. K., & Chang, J. M. (2025) · Radiology · doi:10.1148/radiol.242955 · Cited by 5
Adaptive Breast MRI Scanning Using AI
Eskreis‐Winkler, S., Bhowmik, A., Kelly, L. H., Gullo, R. L., D’Alessio, D., Belen, K., Hogan, M. P., Saphier, N. B., Sevilimedu, V., Sung, J. S., et al. (2025) · Radiology · doi:10.1148/radiol.242924 · Cited by 6
Artificial Intelligence in Breast US Diagnosis and Report Generation
Wang, J., Tian, H., Yang, X., Wu, H., Zhu, X., Chen, R., Chang, A., Chen, Y., Dou, H., Huang, R., et al. (2025) · Radiology Artificial Intelligence · doi:10.1148/ryai.240625 · Cited by 5
Segrado, F., Polymeropoulos, A., Bianchi, M., Veronese, C., Agresti, R., Scaperrotta, G. P., Boffi, R., Miceli, R., & Orlandi, R. (2025) · Cancer Medicine · doi:10.1002/cam4.71279 · Cited by 5
Tveitstøl, T., Tveter, M., Hatlestad‐Hall, C., Hammer, H. L., Engemann, D. A., & Haraldsen, I. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3639477 · Cited by 8
“A RTIFICIAL intelligence (AI) is becoming an increasingly powerful and impactful tool in health and medicine [1], [2].”
The promise of AI in personalized breast cancer screening: are we there yet?
Kontos, D. (2024) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-024-00877-z · Cited by 6
“These tools have shown promise in modelling studies, in which they outperformed conventional CAD systems in the early detection and cancer risk assessment of breast cancers 4,5 .”
Rubegni, E., Ayoub, O., Rizzo, S., Barbero, M., Bernegger, G., Faraci, F. D., Mangili, F., Soldini, E., Trimboli, P., & Facchini, A. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-60606-9_16 · Cited by 9
Artificial intelligence improves breast cancer detection in mammography screening
(2025) · Nature Medicine · doi:10.1038/s41591-025-03714-7 · Cited by 4
Stokel-Walker, C. (2023) · BMJ · doi:10.1136/bmj.p2362 · Cited by 7
Schöder, H. M. (2024) · Journal of Clinical Oncology · doi:10.1200/jco.24.00675 · Cited by 4
Artificial intelligence in breast oncology
Mundinger, A. (2025) · Holistic Integrative Oncology · doi:10.1007/s44178-025-00174-4 · Cited by 3
Scalable Clinical Annotation with Location Evidence (SCALE)
Bosma, J. S., Builtjes, L., Saha, A., Twilt, J. J., Tsiknakis, M., Marias, K., Regge, D., Papanikolaou, N. K., Schoots, I. G., Veltman, J., et al. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.111321 · Cited by 4
Elhadi, Y. A. M., Abdullahi, A. S., Shamsi, A. A., Althehli, A., Alzaabi, H., Ali, H., Alnaqbi, M. M., Alkindi, S., Al-Hashmi, S. A., Razouk, H., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-30880-y · Cited by 3
AI for screening in healthcare: promise and challenges
Saito, K., Walston, S. L., Takita, H., Mitsuyama, Y., Arita, Y., & Ueda, D. (2026) · Abdominal Radiology · doi:10.1007/s00261-025-05370-4 · Cited by 3
“The prospective mammography trials have been reassuring on this front, demonstrating that AI can be integrated without increasing recall rates [ 4 , 40 ].”
InfluentialLarsen, M., Lee, C. I., Bergan, M. B., Holen, Å. S., Lund-Hanssen, H., Hoff, S. R., Auensen, S., Nygård, J. F., Lång, K., Chen, Y., et al. (2026) · European Radiology · doi:10.1007/s00330-025-12240-6 · Cited by 3
Self-citationSampson, A., James, A., & Tripathi, V. (2026) · Journal of Electrical Systems and Information Technology · doi:10.1186/s43067-025-00313-x · Cited by 4
“This study found AI integration in mammography screening to be safe, potentially improving screening efficiency without compromising accuracy [56].”
Open-Source Dataset for the RSNA Screening Mammography Cancer Detection Challenge
Trivedi, H., Vazirabad, M., Kitamura, F., Chen, Y., & Frazer, H. M. L. (2026) · Radiology Artificial Intelligence · doi:10.1148/ryai.250375 · Cited by 7
Goh, S. S. N., Lim, Y. Z., Ong, C., Hartman, M., & Wang, Y. (2026) · Cancers · doi:10.3390/cancers18050836 · Cited by 5
Corines, M. J., Christianson, B., Comstock, C., Drotman, M. B., & Dodelzon, K. (2026) · British Journal of Radiology · doi:10.1093/bjr/tqag053 · Cited by 5
Zhu, Y., Zheng, S., Shao, Y., Zhou, J., Gu, X., Shen, L., Li, X., Liu, W., Xue, W., Lu, H., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-70204-w · Cited by 7
Pesapane, F., Depretto, C., Rotili, A., Penco, S., Monzani, D., Grasso, R., Nicosia, L., Mallardi, C., D’Amelio, L., Carriero, S., et al. (2026) · European Radiology · doi:10.1007/s00330-026-12405-x · Cited by 4
A critical perspective on finite sample conformal prediction theory in medical applications
Kladny, K.-R., Schölkopf, B., Koch, L. M., Baumgartner, C. F., & Muehlebach, M. (2026) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2026.103462 · Cited by 6
Wu, D., Yu, Q., Wu, Q., Wang, X., Wei, H., Li, F., Li, G., Wang, X., & Wang, X. (2026) · Frontiers in Immunology · doi:10.3389/fimmu.2026.1854718 · Cited by 8
Taib, A. G., Partridge, G. J. W., Phillips, P. W., Maxwell-Armstrong, C., Chen, X., Hofvind, S. S. H., James, J. J., & Chen, Y. (2026) · Radiology · doi:10.1148/radiol.252590 · Cited by 11
Self-citationMinimally Invasive Breast Cancer: How to Find Early Breast Cancers
Singh, H., & Bhakta, N. (2024) · Current Breast Cancer Reports · doi:10.1007/s12609-023-00518-x · Cited by 3
“Although further prospective research is needed, AI-supported mammography screening has demonstrated a comparable cancer detection rate to standard double reading, accompanied by a substantially reduced screen-reading workload [38].”
What is the role of artificial intelligence in general surgery?
Baik, S. M., & Lee, R. (2024) · Ewha Medical Journal · doi:10.12771/emj.2024.e22 · Cited by 5
Djurić, O., Deandrea, S., Mantellini, P., Sardanelli, F., Venturelli, F., Montemezzi, S., Vecchio, R., Bucchi, L., Senore, C., Giordano, L., et al. (2024) · La radiologia medica · doi:10.1007/s11547-024-01849-0 · Cited by 3
Research and application of omics and artificial intelligence in cancer
Zhang, Y., Ma, W., Huang, Z., Liu, K., Feng, Z., Zhang, L., Li, D., Mo, T., & Liu, Q. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad6951 · Cited by 8
Singh, S., & Healy, N. A. (2024) · Insights into Imaging · doi:10.1186/s13244-024-01869-4 · Cited by 5
Artificial intelligence in radiation therapy treatment planning: A discrete choice experiment
Lewandowska, M., Street, D. J., Yim, J., Jones, S., & Viney, R. C. (2024) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.843 · Cited by 4
Leveraging innovative research tools to meet public health challenges: a BioMed21 workshop report
Pistollato, F., Furtmann, F., Abitbol, S., Agostinho, M., Andreu, T., Baluta, B., Beets‐Tan, R. G. H., Beken, S., Ciotti, S., Coecke, S., et al. (2025) · NAM journal. · doi:10.1016/j.namjnl.2025.100023 · Cited by 6
Taib, A. G., Partridge, G. J. W., Yao, L., Darker, I. T., & Chen, Y. (2025) · European Radiology · doi:10.1007/s00330-025-11733-8 · Cited by 5
Gerigoorian, A., Kloub, M., Dembrower, K., Engwall, M., & Strand, F. (2025) · BMC Health Services Research · doi:10.1186/s12913-025-13176-9 · Cited by 3
“A study carried out by Lång et al. (2023) [1] demonstrated that AI-supported mammography screening yielded a comparable cancer detection rate to traditional double reading, significantly reducing the workload for radiologists.”
Koch, H. W., Bergan, M. B., Gjesvik, J., Larsen, M., Bartsch, H., Haldorsen, I. S., & Hofvind, S. S. H. (2025) · Acta Radiologica · doi:10.1177/02841851251363697 · Cited by 3
Self-citationGeneralisation and reliability of deep learning for digital pathology in a clinical setting
Pocevičiūtė, M. (2023) · Linköping studies in science and technology. Dissertations · doi:10.3384/9789180753005 · Cited by 6
“Notably, some multicentre prospective clinical studies for radiology [33, 70] and pathology [132] applications have already been published.”
BackgroundAI and imaging-based cancer screening: getting ready for prime time
Kleeff, J. H., & Ronellenfitsch, U. (2023) · Nature Medicine · doi:10.1038/s41591-023-02630-y · Cited by 6
Clinical use cases in artificial intelligence: current trends and future opportunities
Tan, C. H., Goh, W. W. B., So, J. B. Y., & Sung, J. J. �. (2024) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2023-193 · Cited by 3
Karthikeyan, E., & Srinivasan, S. (2025) · Biomedical Materials & Devices · doi:10.1007/s44174-025-00320-6 · Cited by 9
Peters, J., van Leeuwen, M. M., Moriakov, N., van Dijck, J. A. A. M., Mann, R. M., Teuwen, J., Lips, E. H., van den Belt‐Dusebout, A. W., Wesseling, J., de Vries, B. B. L. P., et al. (2025) · British Journal of Cancer · doi:10.1038/s41416-025-02995-6 · Cited by 4
How AI is helping to boost cancer screening
Eisenstein, M. S. (2025) · Nature · doi:10.1038/d41586-025-01153-5 · Cited by 3
Oladimeji, O. O., Imran, A.-A.-Z., Wang, X., & Unnikrishnan, S. (2025) · Image and Vision Computing · doi:10.1016/j.imavis.2025.105601 · Cited by 8
Chang, Y., Ryu, J. K., An, J. K., Choi, N., Park, Y. M., Ko, K. H., & Han, K. (2024) · Research Square · doi:10.21203/rs.3.rs-4147145/v1 · Cited by 3
Clinical Implementation of AI in Screening Mammography: The Essential Role of Prospective Evaluation
Lee, A. Y., & Friedewald, S. M. (2024) · Radiology · doi:10.1148/radiol.241124 · Cited by 5
Kolbinger, F. R., Kirchner, M., Pfeiffer, K., Bodenstedt, S., Jenke, A. C., Barthel, J., Carstens, M., Dehlke, K., Dietz, S., Emmanouilidis, S., et al. (2025) · medRxiv · doi:10.1101/2025.09.05.25335174 · Cited by 4
Heydarlou, H., Hodson, L. J., Dorraki, M., Hickey, T. E., Tilley, W. D., Smith, E., Ingman, W. V., & Farajpour, A. (2025) · Cancers · doi:10.3390/cancers17030449 · Cited by 2
“…approaches can reduce radiologist screening time by triaging the digital mammogram images most likely to require recall and further assessment [31] and identify Of signi fi cance, deep learning approaches can reduce radiologist screening time by tri-aging the digital mammogram images most…”
Questionnaire Survey on the Current Use of Brain Docks and Their Compliance with Guidelines in Japan
KONDO, H., Ikawa, F., Hara, T., Kuwabara, M., Ishii, D., Tomimoto, H., & Horie, N. (2025) · Neurologia medico-chirurgica · doi:10.2176/jns-nmc.2024-0235 · Cited by 2
“29) If AI is effectively used also in brain regions, it can reduce the burden on physicians, shorten their working time, improve diagnostic accuracy, and lower costs, leading to further expansion of the use of brain docks.”
Keeping AI on Track: Regular monitoring of algorithmic updates in mammography
Taib, A. G., James, J. J., Partridge, G. J. W., & Chen, Y. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112100 · Cited by 3
Intelligent Diagnosis of Cervical Lymph Node Metastasis Using a CNN Model
Xu, X., Xi, L., Zhu, J., Feng, C., Zhou, P., Liu, K., Shang, Z., & Shao, Z. (2025) · Journal of Dental Research · doi:10.1177/00220345251322508 · Cited by 5
He, G., Xi, M., Zhang, T., Wang, S., & Liu, G. (2025) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2025.101378 · Cited by 2
“Although advances in medical technology have improved early diagnosis and treatment outcomes, the disease’s complex pathology and high recurrence rates still impose substantial physical and psychological burdens on patients [3,4].”
Radiologische Zukunft gestalten: KI aus Sicht junger Expert*innen
Beste, N. C., Busch, F., Frisch, A., Gassert, F. T., Hoffmann, E., Molwitz, I., Müller, L., Rischen, R., Salhöfer, L., Sieren, M. M., et al. (2025) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-2532-5417 · Cited by 2
Metadata
- Authors
- Lång, K., Josefsson, V., Larsson, A.-M., Larsson, S., Högberg, C., Sartor, H., Hofvind, S., Andersson, I., & Rosso, A.
- Affiliations
- Lund University (SE)
- Cancer Registry of Norway (NO)
- Corresponding author
- Lång, Kristina
- ORCID
- Venue
- The Lancet Oncology
- Publisher
- Elsevier BV
- Published
- 2023-08
- Volume
- 24
- Issue
- 8
- Pages
- 936-944
- ISSN
- 1470-2045 (ISSN-L)
- OpenAlex
- W4385448527
- Semantic Scholar
- abba9a98a0a449e2e14bd6fc8813c996304ddace
- Cited by
- 598
- References
- 30
- Citations by year
- 2026: 197 · 2025: 205 · 2024: 164 · 2023: 31
- FWCI
- 56.30
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- The Lancet Oncology (publishedVersion)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Funders
- Swedish Cancer Society (22 0611FE)
- Skånes universitetssjukhus
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- artificial intelligence, mammography screening, computer-aided detection, double reading, clinical safety, breast cancer detection, recall rate, false positive rate, positive predictive value, non-inferiority, breast cancer screening, breast cancer in situ
- MeSH terms
- Artificial Intelligence, Breast Neoplasms, Female, Humans, Mammography, Mass Screening, Middle Aged, Predictive Value of Tests, Retrospective Studies, Early Detection of Cancer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.